Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Acta Radiol ; : 2841851241275289, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39279297

RESUMEN

BACKGROUND: Radiation dose should be as low as reasonably achievable. With the invention of photon-counting detector computed tomography (PCD-CT), the radiation dose may be considerably reduced. PURPOSE: To evaluate the potential of PCD-CT for dose reduction in pulmonary nodule visualization for human readers as well as for computer-aided detection (CAD) studies. MATERIAL AND METHODS: A chest phantom containing pulmonary nodules of different sizes/densities (range 3-12 mm and -800-100 HU) was scanned on a PCD-CT with standard low-dose protocol as well as with half, quarter, and 1/40 dose (CTDIvol 0.4-0.03 mGy). Dose-matched scans were performed on a third-generation energy-integrating detector CT (EID-CT). Evaluation of nodule visualization and detectability was performed by two blinded radiologists. Subjective image quality was rated on a 5-point Likert scale. Artificial intelligence (AI)-based nodule detection was performed using commercially available software. RESULTS: Highest image noise was found at the lowest dose setting of 1/40 radiation dose (eff. dose = 0.01mSv) with 166.1 ± 18.5 HU for PCD-CT and 351.8 ± 53.0 HU for EID-CT. Overall sensitivity was 100% versus 93% at standard low-dose protocol (eff. dose = 0.2 mSv) for PCD-CT and EID-CT, respectively. At the half radiation dose, sensitivity remained 100% for human reader and CAD studies in PCD-CT. At the quarter radiation dose, PCD-CT achieved the same results as EID-CT at the standard radiation dose setting (93%, P = 1.00) in human reading studies. The AI-CAD system delivered a sensitivity of 93% at the lowest radiation dose level in PCD-CT. CONCLUSION: At half dose, PCD CT showed pulmonary nodules similar to full-dose PCD, and at quarter dose, PCD CT performed comparably to standard low-dose EID CT. The CAD algorithm is effective even at ultra-low doses.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39240440

RESUMEN

Non-invasive imaging with characterization and quantification of the myocardium with computed tomography (CT) became feasible owing to recent technical developments in CT technology. Cardiac CT can serve as an alternative modality when cardiac magnetic resonance imaging and/or echocardiography are contraindicated, not feasible, inconclusive, or non-diagnostic. This review summarizes the current and potential future role of cardiac CT for myocardial characterization including a summary of late enhancement techniques, extracellular volume quantification, and strain analysis. In addition, this review highlights potential fields for research about myocardial characterization with CT to possibly include it in clinical routine in the future.

3.
Br J Radiol ; 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39189964

RESUMEN

PURPOSE: This study assessed the potential of ultra-high-resolution (UHR) and a 1024-matrix in photon-counting-detector CT (PCD-CT) for evaluating interstitial lung disease (ILD) in systemic sclerosis (SSc) patients. MATERIALS AND METHODS: Sixty-six SSc patients who underwent ILD-CT screening on a first-generation PCD-CT were retrospectively included. Scans were performed in UHR mode at 100 kVp with two different matrix sizes (512x512 and 1024x1024) and reconstructed at slice thicknesses of 1.5 mm and 0.2 mm. Image noise, subjective image quality, and ILD changes (1) were evaluated on a 5-point Likert-scale by two independent readers. RESULTS: Interreader agreement for subjective image quality ranged from fair to almost perfect (Krippendorff-Alpha: 0.258-0.862). Overall image quality was highest for 1.5 mm/1024matrix images ((reader 1: 4 (4.4), reader 2: 5 (4.5)). Image sharpness was rated significantly better in 0.2 mm images (p < 0.001). Regarding ILD changes, 0.2 mm slice thickness outperformed 1.5 mm slice thickness significantly (p < 0.001), while there was no significant difference between the two matrix sizes. 1024 matrix size demonstrated superiority in evaluating coarse reticulations compared to 512matrix size. CONCLUSION: UHR mode with a 0.2 mm slice thickness showed enhanced image sharpness and improved visibility of ILD changes compared to standard reconstructions. This has the potential to enable the early detection of subtle disease manifestations. ADVANCES IN KNOWLEDGE: With the invention of PCD-CT different reconstruction algorithms need to be evaluated for specific pathologies. In our study ILD UHR mode with 0.2 mm slice thickness showed to be beneficial in the detection of parenchymal changes in patients with scleroderma.

4.
AJR Am J Roentgenol ; 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39166723

RESUMEN

Background: Pericoronary adipose tissue (PCAT) attenuation and fat attenuation index (FAI) may serve as markers of inflammation and risk of adverse cardiac events. However, standardization of relevant CT acquisition and reconstruction parameters is lacking. Objective: To investigate the influence of vessel attenuation, virtual monoenergetic image (VMI) level, and reconstruction kernel on PCAT attenuation and FAI using energy-integrating detector (EID) and photon-counting detector (PCD) CT systems in an ex-vivo porcine heart model. Methods: A porcine heart's right coronary artery (RCA) was injected with saline or varying contrast media dilutions to achieve vessel attenuations ranging from 0 to 1000 HU. After each injection, the heart was scanned with EID CT at 120 kVp and PCD CT at 140 kVp, at constant CTDIvol (10 mGy). For EID CT, polychromatic images were reconstructed with Qr40 kernel. For PCD CT, VMI (40-80 keV at 10-keV increments) were reconstructed with Qr40, Bv40, and Bv56 kernels. ROIs were placed to measure RCA and PCAT attenuation. FAI was determined using software; histogram analysis was performed of voxel attenuations in the volumes of interest for FAI calculation. Results: Correlations were observed between attenuation in the RCA and adjacent PCAT (r=0.3-1.0), and between vessel attenuation and FAI (r=-0.9-1.0). For PCAT attenuation and FAI, these associations became progressively weaker for progressively sharper kernels. For increasing vessel attenuation for EID CT and for increasing VMI level for PCD CT, FAI histograms showed right shifts of the peak attenuation; the percentage of histogram voxels meeting the threshold range for inclusion in FAI calculation for EID CT was 8-29% and for PCD CT at VMI levels of 70-80 keV was 5-42%. For PCD CT, sharper kernels were associated with left shifts in peak attenuations and greater percentages of voxels within the threshold range for inclusion in FAI calculations. Conclusion: PCAT attenuation and FAI are influenced by vessel lumen attenuation, VMI level, and reconstruction kernel. A minority of pericoronary voxels contribute to FAI measurements for polychromatic EID CT and for PCD CT at high VMI levels. Clinical Impact: These findings may help standardize acquisition and reconstruction parameters for PCAT attenuation and FAI measurements.

5.
Eur J Radiol Open ; 12: 100574, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38882632

RESUMEN

Purpose: To determine the value of an algorithm for reducing stair-step artifacts for advanced coronary analyses in sequential mode coronary CT angiography (CCTA). Methods: Forty patients undergoing sequential mode photon-counting detector CCTA with at least one stair-step artifact were included. Twenty patients (14 males; mean age 57±17years) with 45 segments showing stair-step artifacts and without atherosclerosis were included for CTFFR analysis. Twenty patients (20 males; mean age 74±13years) with 22 segments showing stair-step artifacts crossing an atherosclerotic plaque were included for quantitative plaque analysis. Artifacts were graded, and CTFFR and quantitative coronary plaque analyses were performed in standard reconstructions and in those reconstructed with a software (entitled ZeeFree) for artifact reduction. Results: Stair-step artifacts were significantly reduced in ZeeFree compared to standard reconstructions (p<0.05). In standard reconstructions, CTFFR was not feasible in 3/45 (7 %) segments but was feasible in all ZeeFree reconstructions. In 9/45 (20 %) segments without atherosclerosis, the ZeeFree algorithm led to a change of CTFFR values from pathologic in standard to physiologic values in ZeeFree reconstructions. In one segment (1/22, 5 %), quantitative plaque analysis was not feasible in standard but only in ZeeFree reconstruction. The mean overall plaque volume (111±60 mm3), the calcific (77±47 mm3), fibrotic (31±28 mm3), and lipidic (4±3 mm3) plaque components were higher in standard than in ZeeFree reconstructions (overall 75±50 mm3, p<0.001; calcific 51±42 mm3, p<0.001; fibrotic 22±19 mm3, p<0.05; lipidic 3±3 mm3, p=0.055). Conclusion: Despite the lack of reference standard modalities for CTFFR and coronary plaque analysis, initial evidence indicates that an algorithm for reducing stair-step artifacts in sequential mode CCTA increases the rate and quality of datasets amenable to advanced coronary artery analysis, hereby potentially improving patient management.

6.
Eur Radiol ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38935123

RESUMEN

OBJECTIVES: To assess the accuracy of a synthetic hematocrit derived from virtual non-contrast (VNC) and virtual non-iodine images (VNI) for myocardial extracellular volume (ECV) computation with photon-counting detector computed tomography (PCD-CT). MATERIALS AND METHODS: Consecutive patients undergoing PCD-CT including a coronary CT angiography (CCTA) and a late enhancement (LE) scan and having a blood hematocrit were retrospectively included. In the first 75 patients (derivation cohort), CCTA and LE scans were reconstructed as VNI at 60, 70, and 80 keV and as VNC with quantum iterative reconstruction (QIR) strengths 2, 3, and 4. Blood pool attenuation (BPmean) was correlated to blood hematocrit. In the next 50 patients (validation cohort), synthetic hematocrit was calculated using BPmean. Myocardial ECV was computed using the synthetic hematocrit and compared with the ECV using the blood hematocrit as a reference. RESULTS: In the derivation cohort (49 men, mean age 79 ± 8 years), a correlation between BPmean and blood hematocrit ranged from poor for VNI of CCTA at 80 keV, QIR2 (R2 = 0.12) to moderate for VNI of LE at 60 keV, QIR4; 70 keV, QIR3 and 4; and VNC of LE, QIR3 and 4 (all, R2 = 0.58). In the validation cohort (29 men, age 75 ± 14 years), synthetic hematocrit was calculated from VNC of the LE scan, QIR3. Median ECV was 26.9% (interquartile range (IQR), 25.5%, 28.8%) using the blood hematocrit and 26.8% (IQR, 25.4%, 29.7%) using synthetic hematocrit (VNC, QIR3; mean difference, -0.2%; limits of agreement, -2.4%, 2.0%; p = 0.33). CONCLUSION: Synthetic hematocrit calculated from VNC images enables an accurate computation of myocardial ECV with PCD-CT. CLINICAL RELEVANCE STATEMENT: Virtual non-contrast images from cardiac late enhancement scans with photon-counting detector CT allow the calculation of a synthetic hematocrit, which enables accurate computation of myocardial extracellular volume. KEY POINTS: Blood hematocrit is mandatory for conventional myocardial extracellular volume computation. Synthetic hematocrit can be calculated from virtual non-iodine and non-contrast photon-counting detector CT images. Synthetic hematocrit from virtual non-contrast images enables computation of the myocardial extracellular volume.

8.
Front Cardiovasc Med ; 11: 1367463, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38455720

RESUMEN

Purpose: To evaluate the feasibility and accuracy of quantification of calcified coronary stenoses using virtual non-calcium (VNCa) images in coronary CT angiography (CCTA) with photon-counting detector (PCD) CT compared with quantitative coronary angiography (QCA). Materials and methods: This retrospective, institutional-review board approved study included consecutive patients with calcified coronary artery plaques undergoing CCTA with PCD-CT and invasive coronary angiography between July and December 2022. Virtual monoenergetic images (VMI) and VNCa images were reconstructed. Diameter stenoses were quantified on VMI and VNCa images by two readers. 3D-QCA served as the standard of reference. Measurements were compared using Bland-Altman analyses, Wilcoxon tests, and intraclass correlation coefficients (ICC). Results: Thirty patients [mean age, 64 years ± 8 (standard deviation); 26 men] with 81 coronary stenoses from calcified plaques were included. Ten of the 81 stenoses (12%) had to be excluded because of erroneous plaque subtraction on VNCa images. Median diameter stenosis determined on 3D-QCA was 22% (interquartile range, 11%-35%; total range, 4%-88%). As compared with 3D-QCA, VMI overestimated diameter stenoses (mean differences -10%, p < .001, ICC: .87 and -7%, p < .001, ICC: .84 for reader 1 and 2, respectively), whereas VNCa images showed similar diameter stenoses (mean differences 0%, p = .68, ICC: .94 and 1%, p = .07, ICC: .93 for reader 1 and 2, respectively). Conclusion: First experience in mainly minimal to moderate stenoses suggests that virtual calcium removal in CCTA with PCD-CT, when feasible, has the potential to improve the quantification of calcified stenoses.

9.
Radiol Cardiothorac Imaging ; 6(2): e230217, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38451189

RESUMEN

Purpose To compare image quality, diagnostic performance, and conspicuity between single-energy and multi-energy images for endoleak detection at CT angiography (CTA) after endovascular aortic repair (EVAR). Materials and Methods In this single-center prospective randomized controlled trial, individuals undergoing CTA after EVAR between August 2020 and May 2022 were allocated to imaging using either low-kilovolt single-energy images (SEI; 80 kV, group A) or low-kiloelectron volt virtual monoenergetic images (VMI) at 40 and 50 keV from multi-energy CT (80/Sn150 kV, group B). Scan protocols were dose matched (volume CT dose index: mean, 4.5 mGy ± 1.8 [SD] vs 4.7 mGy ± 1.3, P = .41). Contrast-to-noise ratio (CNR) was measured. Two expert radiologists established the reference standard for the presence of endoleaks. Detection and conspicuity of endoleaks and subjective image quality were assessed by two different blinded radiologists. Interreader agreement was calculated. Nonparametric statistical tests were used. Results A total of 125 participants (mean age, 76 years ± 8; 103 men) were allocated to groups A (n = 64) and B (n = 61). CNR was significantly lower for 40-keV VMI (mean, 19.1; P = .048) and 50-keV VMI (mean, 16.8; P < .001) as compared with SEI (mean, 22.2). In total, 45 endoleaks were present (A: 23 vs B: 22). Sensitivity for endoleak detection was higher for SEI (82.6%, 19 of 23; P = .88) and 50-keV VMI (81.8%, 18 of 22; P = .90) as compared with 40-keV VMI (77.3%, 17 of 22). Specificity was comparable among groups (SEI: 92.7%, 38 of 41; both VMI energies: 92.3%, 35 of 38; P = .99), with an interreader agreement of 1. Conspicuity of endoleaks was comparable between SEI (median, 2.99) and VMI (both energies: median, 2.87; P = .04). Overall subjective image quality was rated significantly higher for SEI (median, 4 [IQR, 4-4) as compared with 40 and 50 keV (both energies: median, 4 [IQR, 3-4]; P < .001). Conclusion SEI demonstrated higher image quality and comparable diagnostic accuracy as compared with 50-keV VMI for endoleak detection at CTA after EVAR. Keywords: Aneurysms, CT, CT Angiography, Vascular, Aorta, Technology Assessment, Multidetector CT, Abdominal Aortic Aneurysms, Endoleaks, Perigraft Leak Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Angiografía por Tomografía Computarizada , Endofuga , Anciano , Humanos , Masculino , Aorta , Endofuga/diagnóstico por imagen , Fenómenos Físicos , Estudios Prospectivos , Femenino
10.
Artículo en Inglés | MEDLINE | ID: mdl-38389028

RESUMEN

To intra-individually investigate the variation of coronary artery calcium (CAC), aortic valve calcium (AVC), and mitral annular calcium (MAC) scores and the presence of blur artifacts as a function of temporal resolution in patients undergoing non-contrast cardiac CT on a dual-source photon counting detector (PCD) CT. This retrospective, IRB-approved study included 70 patients (30 women, 40 men, mean age 78 ± 9 years) who underwent ECG-gated cardiac non-contrast CT with PCD-CT (gantry rotation time 0.25 s) prior to transcatheter aortic valve replacement. Each scan was reconstructed at a temporal resolution of 66 ms using the dual-source information and at 125 ms using the single-source information. Average heart rate and heart rate variability were calculated from the recorded ECG. CAC, AVC, and MAC were quantified according to the Agatston method on images with both temporal resolutions. Two readers assessed blur artifacts using a 4-point visual grading scale. The influence of average heart rate and heart rate variability on calcium quantification and blur artifacts of the respective structures were analyzed by linear regression analysis. Mean heart rate and heart rate variability during data acquisition were 76 ± 17 beats per minute (bpm) and 4 ± 6 bpm, respectively. CAC scores were smaller on 66 ms (median, 511; interquartile range, 220-978) than on 125 ms reconstructions (538; 203-1050, p < 0.001). Median AVC scores [2809 (2009-3952) versus 3177 (2158-4273)] and median MAC scores [226 (0-1284) versus 251 (0-1574)] were also significantly smaller on 66ms than on 125ms reconstructions (p < 0.001). Reclassification of CAC and AVC risk categories occurred in 4% and 11% of cases, respectively, whereby the risk category was always overestimated on 125ms reconstructions. Image blur artifacts were significantly less on 66ms as opposed to 125 ms reconstructions (p < 0.001). Intra-individual analyses indicate that temporal resolution significantly impacts on calcium scoring with cardiac CT, with CAC, MAC, and AVC being overestimated at lower temporal resolution because of increased motion artifacts eventually leading to an overestimation of patient risk.

11.
Invest Radiol ; 59(9): 622-628, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38284879

RESUMEN

PURPOSE: Prospective electrocardiography-triggering is one of the most commonly used cardiac computed tomography (CT) scan modes but can be susceptible to stair-step artifacts in the transition areas of an acquisition over multiple cardiac cycles. We evaluated a novel reconstruction algorithm to reduce the occurrence and severity of such artifacts in sequential coronary CT angiography. MATERIALS AND METHODS: In this institutional review board-approved, retrospective study, 50 consecutive patients (16 females; mean age, 58.9 ± 15.2) were included who underwent coronary CT angiography on a dual-source photon-counting detector CT in the sequential ultra-high-resolution mode with a detector collimation of 120 × 0.2 mm. Each scan was reconstructed without (hereafter called standard reconstruction) and with the novel ZeeFree reconstruction algorithm, which aims to minimize stair-step artifacts. The presence and extent of stair-step artifacts were rated by 2 independent, blinded readers on a 4-point discrete visual scale. The relationship between the occurrences of artifacts was correlated with the average and variability of heart rate and with patient characteristics. RESULTS: A total of 504 coronary segments were included into the analyses. In standard reconstructions, reader 1 reported stair-step artifacts in 40/504 (7.9%) segments, from which 12/504 led to nondiagnostic image quality (2.4% of all segments). Reader 2 reported 56/504 (11.1%) stair-step artifacts, from which 11/504 lead to nondiagnostic image quality (2.2% of all segments). With the ZeeFree algorithm, 9/12 (75%) and 8/11 (73%) of the nondiagnostic segments improved to a diagnostic quality for readers 1 and 2, respectively. The ZeeFree reconstruction algorithm significantly reduced the frequency and extent of stair-step artifacts compared with standard reconstructions for both readers ( P < 0.001, each). Heart rate variability and body mass index were significantly related to the occurrence of stair-step artifacts ( P < 0.05). CONCLUSIONS: Our study demonstrates the feasibility and effectiveness of a novel reconstruction algorithm leading to a significant reduction of stair-step artifacts and, hence, a reduction of coronary segments with a nondiagnostic image quality in sequential ultra-high-resolution coronary photon-counting detector CT angiography.


Asunto(s)
Algoritmos , Artefactos , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Humanos , Femenino , Masculino , Angiografía Coronaria/métodos , Persona de Mediana Edad , Angiografía por Tomografía Computarizada/métodos , Estudios Retrospectivos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Anciano , Electrocardiografía/métodos
12.
Invest Radiol ; 59(8): 554-560, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38193782

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the optimal energy level of virtual monoenergetic images (VMIs) from photon-counting detector computed tomography (CT) for the detection of liver lesions as a function of phantom size and radiation dose. MATERIALS AND METHODS: An anthropomorphic abdominal phantom with liver parenchyma and lesions was imaged on a dual-source photon-counting detector CT at 120 kVp. Five hypoattenuating lesions with a lesion-to-background contrast difference of -30 HU and -45 HU and 3 hyperattenuating lesions with +30 HU and +90 HU were used. The lesion diameter was 5-10 mm. Rings of fat-equivalent material were added to emulate medium- or large-sized patients. The medium size was imaged at a volume CT dose index of 5, 2.5, and 1.25 mGy and the large size at 5 and 2.5 mGy, respectively. Each setup was imaged 10 times. For each setup, VMIs from 40 to 80 keV at 5 keV increments were reconstructed with quantum iterative reconstruction at a strength level of 4 (QIR-4). Lesion detectability was measured as area under the receiver operating curve (AUC) using a channelized Hotelling model observer with 10 dense differences of Gaussian channels. RESULTS: Overall, highest detectability was found at 65 and 70 keV for both hypoattenuating and hyperattenuating lesions in the medium and large phantom independent of radiation dose (AUC range, 0.91-1.0 for the medium and 0.94-0.99 for the large phantom, respectively). The lowest detectability was found at 40 keV irrespective of the radiation dose and phantom size (AUC range, 0.78-0.99). A more pronounced reduction in detectability was apparent at 40-50 keV as compared with 65-75 keV when radiation dose was decreased. At equal radiation dose, detection as a function of VMI energy differed stronger for the large size as compared with the medium-sized phantom (12% vs 6%). CONCLUSIONS: Detectability of hypoattenuating and hyperattenuating liver lesions differed between VMI energies for different phantom sizes and radiation doses. Virtual monoenergetic images at 65 and 70 keV yielded highest detectability independent of phantom size and radiation dose.


Asunto(s)
Neoplasias Hepáticas , Fantasmas de Imagen , Fotones , Dosis de Radiación , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/instrumentación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Tamaño Corporal , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Hígado/diagnóstico por imagen
13.
Acad Radiol ; 31(1): 212-220, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37532596

RESUMEN

RATIONALE AND OBJECTIVES: To determine the optimal virtual monoenergetic image (VMI) energy level and the potential of contrast-media (CM) reduction for coronary computed tomography angiography (CCTA) with photon-counting detector CT (PCD-CT). MATERIALS AND METHODS: In this institutional review board-approved study, patients who underwent CCTA with dual-source PCD-CT with an identical scan protocol and radiation dose were included. In group 1, CCTA was performed with our standard CM protocol (volume: 72-85.2 mL, 370 mg iodine/mL). VMIs were reconstructed from 40 to 60 keV at 5 keV increments. Objective image quality (IQ) (vascular attenuation, image noise, and contrast-to-noise ratio [CNR]) was measured. Two blinded, independent readers rated subjective IQ (overall IQ, subjective image contrast, and subjective noise using a five-point discrete visual scale). Results of group 1 served to determine the best VMI level for CCTA. In group 2, CM volume was reduced by 20%, and in group 3 by another 20%. RESULTS: A total of 100 patients were enrolled (45 females, mean age 54 ± 13 years). Inter-reader agreement was good-to-excellent for all comparisons (κ > 0.6). In group 1, the best VMI level regarding objective and subjective IQ was 45 keV, which was selected as the reference for groups 2 and 3. For group 2, mean vascular attenuation was 890 Hounsfield units (HU) and mean CNR was 26, with no differences compared to group 1, 45 keV for both objective and subjective IQ. For group 3, mean vascular attenuation was 676 HU and mean CNR was 21, and all patients were rated as diagnostic except one (severe motion artifacts). CONCLUSION: Increased IQ of PCD-CT can be used for considerable CM volume reduction while still maintaining a diagnostic IQ of CCTA.


Asunto(s)
Angiografía por Tomografía Computarizada , Imagen Radiográfica por Emisión de Doble Fotón , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste , Relación Señal-Ruido , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos
16.
BMC Urol ; 23(1): 173, 2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37891557

RESUMEN

BACKGROUND: To investigate the association between erectile dysfunction (ED) as well as epistaxis (ES) in relation to the extent of iliac atherosclerosis. METHODS: In this retrospective cross-sectional study, all consecutive male patients treated at our institution from 01/2016 to 12/2020 undergoing abdominal CT scan were evaluated. Patients (n = 1272) were invited by mail to participate in the study in returning two questionnaires for the evaluation of ED (IIEF-5) and ES. Patients who returned filled-in questionnaires within a 3-month deadline were included in the study. The extent of atherosclerosis in the common iliac artery (CIA) and the internal iliac artery (IIA) was assessed by calcium scoring on unenhanced CT. Stratification of results was performed according to reported IIEF-5 scores and consequential ED groups. RESULTS: In total, 437 patients (34.4% of contacted) met the inclusion criteria. Forty-two patients did not fulfill predefined age requirements (< 75 years) and 120 patients had to be excluded as calcium scoring on nonenhanced CT was not feasible. Finally, 275 patients were included in the analysis and stratified into groups of "no-mild" (n = 146) and "moderate-severe" (n = 129) ED. The calcium score (r=-0.28, p < 0.001) and the number of atherosclerotic lesions (r=-0.32, p < 0.001) in the CIA + IIA showed a significant negative correlation to the IIEF-5 score, respectively. Patients differed significantly in CIA + IIA calcium score (difference: 167.4, p < 0.001) and number of atherosclerotic lesions (difference: 5.00, p < 0.001) when belonging to the "no-mild" vs. "moderate-severe" ED group, respectively. A multivariable regression model, after adjusting for relevant baseline characteristics, showed that the number of atherosclerotic CIA + IIA lesions was an independent predictor of ED (OR = 1.05, p = 0.036), whereas CIA + IIA calcium score was not (OR = 1.00031, p = 0.20). No relevant correlation was found between ES episodes and IIEF-5 scores (r=-0.069, p = 0.25), CIA + IIA calcium score (r=-0.10, p = 0.87) or number of atherosclerotic CIA + IIA lesions (r=-0.032, p = 0.60), respectively. CONCLUSIONS: The number of atherosclerotic lesions in the iliac arteries on nonenhanced abdominal CT scans is associated with the severity of ED. This may be used to identify subclinical cardiovascular disease and to quantify the risk for cardiovascular hazards in the future. TRIAL REGISTRATION: BASEC-Nr. 2020 - 01637.


Asunto(s)
Aterosclerosis , Disfunción Eréctil , Humanos , Masculino , Anciano , Disfunción Eréctil/diagnóstico por imagen , Disfunción Eréctil/complicaciones , Arteria Ilíaca/diagnóstico por imagen , Estudios Retrospectivos , Calcio , Estudios Transversales , Epistaxis/complicaciones , Aterosclerosis/complicaciones , Aterosclerosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X
17.
Invest Radiol ; 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37812482

RESUMEN

OBJECTIVES: With the introduction of clinical photon-counting detector computed tomography (PCD-CT) and its novel reconstruction techniques, a quantitative investigation of different acquisition and reconstruction settings is necessary to optimize clinical acquisition protocols for metal artifact reduction. MATERIALS AND METHODS: A multienergy phantom was scanned on a clinical dual-source PCD-CT (NAEOTOM Alpha; Siemens Healthcare GmbH) with 4 different central inserts: water-equivalent plastic, aluminum, steel, and titanium. Acquisitions were performed at 120 kVp and 140 kVp (CTDIvol 10 mGy) and reconstructed as virtual monoenergetic images (VMIs; 110-150 keV), as T3D, and with the standard reconstruction "none" (70 keV VMI) using different reconstruction kernels (Br36, Br56) and with as well as without iterative metal artifact reduction (iMAR). Metal artifacts were quantified, calculating relative percentages of metal artifacts. Mean CT numbers of an adjacent water-equivalent insert and different tissue-equivalent inserts were evaluated, and eccentricity of metal rods was measured. Repeated-measures analysis of variance was performed for statistical analysis. RESULTS: Metal artifacts were most prevalent for the steel insert (12.6% average artifacts), followed by titanium (4.2%) and aluminum (1.0%). The strongest metal artifact reduction was noted for iMAR (with iMAR: 1.4%, without iMAR: 10.5%; P < 0.001) or VMI (VMI: 110 keV 2.6% to 150 keV 3.3%, T3D: 11.0%, and none: 16.0%; P < 0.001) individually, with best results when combining iMAR and VMI at 110 keV (1.2%). Changing acquisition tube potential (120 kV: 6.6%, 140 kV: 5.2%; P = 0.33) or reconstruction kernel (Br36: 5.5%, Br56: 6.4%; P = 0.17) was less effective. Mean CT numbers and standard deviations were significantly affected by iMAR (with iMAR: -3.0 ± 21.5 HU, without iMAR: -8.5 ± 24.3 HU; P < 0.001), VMI (VMI: 110 keV -3.6 ± 21.6 HU to 150 keV -1.4 ± 21.2 HU, T3D: -11.7 ± 23.8 HU, and none: -16.9 ± 29.8 HU; P < 0.001), tube potential (120 kV: -4.7 ± 22.8 HU, 140 kV: -6.8 ± 23.0 HU; P = 0.03), and reconstruction kernel (Br36: -5.5 ± 14.2 HU, Br56: -6.8 ± 23.0 HU; P < 0.001). Both iMAR and VMI improved quantitative CT number accuracy and metal rod eccentricity for the steel rod, but iMAR was of limited effectiveness for the aluminum rod. CONCLUSIONS: For metal artifact reduction in PCD-CT, a combination of iMAR and VMI at 110 keV demonstrated the strongest artifact reduction of the evaluated options, whereas the impact of reconstruction kernel and tube potential was limited.

18.
Insights Imaging ; 14(1): 156, 2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37749293

RESUMEN

Non-invasive quantification of the extracellular volume (ECV) is a method for the evaluation of focal and diffuse myocardial fibrosis, potentially obviating the need for invasive endomyocardial biopsy. While ECV quantification with cardiac magnetic resonance imaging (ECVMRI) is already an established method, ECV quantification with CT (ECVCT) is an attractive alternative to ECVMRI, similarly using the properties of extracellular contrast media for ECV calculation. In contrast to ECVMRI, ECVCT provides a more widely available, cheaper and faster tool for ECV quantification and allows for ECV calculation also in patients with contraindications for MRI. Many studies have already shown a high correlation between ECVCT and ECVMRI and accumulating evidence suggests a prognostic value of ECVCT quantification in various cardiovascular diseases. Adding a late enhancement scan (for dual energy acquisitions) or a non-enhanced and late enhancement scan (for single-energy acquisitions) to a conventional coronary CT angiography scan improves risk stratification, requiring only minor adaptations of the contrast media and data acquisition protocols and adding only little radiation dose to the entire scan.Critical relevance statementThis article summarizes the technical principles of myocardial extracellular volume (ECV) quantification with CT, reviews the literature comparing ECVCT with ECVMRI and histopathology, and reviews the prognostic value of myocardial ECV quantification for various cardiovascular disease.Key points• Non-invasive quantification of myocardial fibrosis can be performed with CT.• Myocardial ECV quantification with CT is an alternative in patients non-eligible for MRI.• Myocardial ECV quantification with CT strongly correlates with ECV quantification using MRI.• Myocardial ECV quantification provides incremental prognostic information for various pathologies affecting the heart (e.g., cardiac amyloidosis).

19.
Radiol Cardiothorac Imaging ; 5(3): e220307, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37404795

RESUMEN

Purpose: To assess the accuracy of aortic valve calcium (AVC), mitral annular calcium (MAC), and coronary artery calcium (CAC) quantification and risk stratification using virtual noncontrast (VNC) images from late enhancement photon-counting detector CT as compared with true noncontrast images. Materials and Methods: This retrospective, institutional review board-approved study evaluated patients undergoing photon-counting detector CT between January and September 2022. VNC images were reconstructed from late enhancement cardiac scans at 60, 70, 80, and 90 keV using quantum iterative reconstruction (QIR) strengths of 2-4. AVC, MAC, and CAC were quantified on VNC images and compared with quantification of AVC, MAC, and CAC on true noncontrast images using Bland-Altman analyses, regression models, intraclass correlation coefficients (ICC), and Wilcoxon tests. Agreement between severe aortic stenosis likelihood categories and CAC risk categories determined from VNC and true noncontrast images was assessed by weighted κ analysis. Results: Ninety patients were included (mean age, 80 years ± 8 [SD]; 49 male patients). Scores were similar on true noncontrast images and VNC images at 80 keV for AVC and MAC, regardless of QIR strengths, and VNC images at 70 keV with QIR 4 for CAC (all P > .05). The best results were achieved using VNC images at 80 keV with QIR 4 for AVC (mean difference, 3; ICC = 0.992; r = 0.98) and MAC (mean difference, 6; ICC = 0.998; r = 0.99), and VNC images at 70 keV with QIR 4 for CAC (mean difference, 28; ICC = 0.996; r = 0.99). Agreement between calcification categories was excellent on VNC images at 80 keV for AVC (κ = 0.974) and on VNC images at 70 keV for CAC (κ = 0.967). Conclusion: VNC images from cardiac photon-counting detector CT enables patient risk stratification and accurate quantification of AVC, MAC, and CAC.Keywords: Coronary Arteries, Aortic Valve, Mitral Valve, Aortic Stenosis, Calcifications, Photon-counting Detector CT Supplemental material is available for this article © RSNA, 2023.

20.
Adv Sci (Weinh) ; 10(23): e2301207, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37276437

RESUMEN

Postoperative anastomotic leaks are the most feared complications after gastric surgery. For diagnostics clinicians mostly rely on clinical symptoms such as fever and tachycardia, often developing as a result of an already fully developed, i.e., symptomatic, surgical leak. A gastric fluid responsive, dual modality, electronic-free, leak sensor system integrable into surgical adhesive suture support materials is introduced. Leak sensors contain high atomic number carbonates embedded in a polyacrylamide matrix, that upon exposure to gastric fluid convert into gaseous carbon dioxide (CO2 ). CO2 bubbles remain entrapped in the hydrogel matrix, leading to a distinctly increased echogenic contrast detectable by a low-cost and portable ultrasound transducer, while the dissolution of the carbonate species and the resulting diffusion of the cation produces a markedly reduced contrast in computed tomography imaging. The sensing elements can be patterned into a variety of characteristic shapes and can be combined with nonreactive tantalum oxide reference elements, allowing the design of shape-morphing sensing elements visible to the naked eye as well as artificial intelligence-assisted automated detection. In summary, shape-morphing dual modality sensors for the early and robust detection of postoperative complications at deep tissue sites, opening new routes for postoperative patient surveillance using existing hospital infrastructure is reported.


Asunto(s)
Inteligencia Artificial , Dióxido de Carbono , Humanos , Complicaciones Posoperatorias , Fuga Anastomótica/diagnóstico , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA