Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Fluids Barriers CNS ; 21(1): 56, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38997764

RESUMEN

BACKGROUND: The cerebrospinal fluid (CSF), primarily generated by the choroid plexus (ChP), is the major carrier of the glymphatic system. The alternations of CSF production and the ChP can be associated with the Alzheimer's disease (AD). The present work investigated the roles of the ChP in the AD based on a proposed ChP image segmentation pipeline. METHODS: A human-in-the-loop ChP image segmentation pipeline was implemented with intermediate and active learning datasets. The performance of the proposed pipeline was evaluated on manual contours by five radiologists, compared to the FreeSurfer and FastSurfer toolboxes. The ChP volume and blood flow were investigated among AD groups. The correlations between the ChP volume and AD CSF biomarkers including phosphorylated tau (p-tau), total tau (t-tau), amyloid-ß42 (Aß42), and amyloid-ß40 (Aß40) was investigated using three models (univariate, multiple variables, and stepwise regression) on two datasets with 806 and 320 subjects. RESULTS: The proposed ChP segmentation pipeline achieved superior performance with a Dice coefficient of 0.620 on the test dataset, compared to the FreeSurfer (0.342) and FastSurfer (0.371). Significantly larger volumes (p < 0.001) and higher perfusion (p = 0.032) at the ChP were found in AD compared to CN groups. Significant correlations were found between the tau and the relative ChP volume (the ChP volume and ChP/parenchyma ratio) in each patient groups and in the univariate regression analysis (p < 0.001), the multiple regression model (p < 0.05 except for the t-tau in the LMCI), and in the step-wise regression model (p < 0.021). In addition, the correlation coefficients changed from - 0.32 to - 0.21 along with the AD progression in the multiple regression model. In contrast, the Aß42 and Aß40 shows consistent and significant associations with the lateral ventricle related measures in the step-wise regression model (p < 0.027). CONCLUSIONS: The proposed pipeline provided accurate ChP segmentation which revealed the associations between the ChP and tau level in the AD. The proposed pipeline is available on GitHub ( https://github.com/princeleeee/ChP-Seg ).


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Plexo Coroideo , Proteínas tau , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/metabolismo , Enfermedad de Alzheimer/líquido cefalorraquídeo , Humanos , Proteínas tau/líquido cefalorraquídeo , Proteínas tau/metabolismo , Plexo Coroideo/diagnóstico por imagen , Plexo Coroideo/metabolismo , Péptidos beta-Amiloides/líquido cefalorraquídeo , Péptidos beta-Amiloides/metabolismo , Masculino , Femenino , Anciano , Aprendizaje Automático Supervisado , Biomarcadores/líquido cefalorraquídeo , Biomarcadores/metabolismo , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Persona de Mediana Edad , Anciano de 80 o más Años
2.
Acad Radiol ; 31(4): 1666-1675, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37977888

RESUMEN

RATIONALE AND OBJECTIVES: The current clinical standard for functional imaging of patients with lung ailments is nuclear medicine scintigraphy and Single Photon Emission Computed Tomography (SPECT) which detect the gamma decay of inhaled radioactive tracers. Hyperpolarized (HP) Xenon-129 MRI (XeMRI) of the lungs has recently been FDA approved and provides similar functional images of the lungs with higher spatial resolution than scintigraphy and SPECT. Here we compare Technetium-99m (99mTc) diethylene-triamine-pentaacetate scintigraphy and SPECT with HP XeMRI in healthy controls, asthma, and chronic obstructive pulmonary disorder (COPD) patients. MATERIALS AND METHODS: 59 subjects, healthy, with asthma, and with COPD, underwent 99mTc scintigraphy/SPECT, standard spirometry, and HP XeMRI. XeMRI and SPECT images were registered for direct voxel-wise signal comparisons. Images were also compared using ventilation defect percentage (VDP), and a standard 6-compartment method. VDP calculated from XeMRI and SPECT images was compared to spirometry. RESULTS: Median Pearson correlation coefficient for voxel-wise signal comparison was 0.698 (0.613-0.782) between scintigraphy and XeMRI and 0.398 (0.286-0.502) between SPECT and XeMRI. Correlation between VDP measures was r = 0.853, p < 0.05. VDP separated asthma and COPD from the control group and was significantly correlated with FEV1, FEV1/FVC, and FEF 25-75. CONCLUSION: HP XeMRI provides equivalent information to 99mTc SPECT and standard spirometry measures. Additionally, XeMRI is non-invasive, hence it could be used for longitudinal studies for evaluating emerging treatment for lung ailments.


Asunto(s)
Asma , Enfermedad Pulmonar Obstructiva Crónica , Isótopos de Xenón , Humanos , Pruebas de Función Respiratoria , Pulmón/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Imagen por Resonancia Magnética/métodos , Asma/diagnóstico por imagen
3.
Ultrasound Med Biol ; 49(12): 2519-2526, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37730478

RESUMEN

OBJECTIVE: A coupling bath of circulating, chilled, degassed water is essential to safe and precise acoustic transmittance during transcranial magnetic resonance-guided focused ultrasound (tMRgFUS) procedures, but the circulating water impairs the critical real-time magnetic resonance imaging (MRI). An iron-based coupling medium (IBCM) using iron oxide nanoparticles previously developed by our group increased the relaxivity of the coupling bath such that it appears to be invisible on MRI compared with degassed water. However, the nanoparticles also reduced the pressure threshold for cavitation. To address this concern for prefocal cavitation, our group recently developed an IBCM of electrosterically stabilized and aggregation-resistant poly(methacrylic acid)-coated iron oxide nanoparticles (PMAA-FeOX) with a similar capability to reduce the MR signal of degassed water. This study examines the effect of the PMAA-FeOX IBCM on the cavitation threshold. METHODS: Increasing concentrations of PMAA-FeOX nanoparticles in degassed, deionized water were placed at the focus of two different transducers to assess low and high duty-cycle pulsing parameters which are representative of two modes of focused ultrasound being investigated for tMRgFUS. Passive cavitation detection and high-speed optical imaging were used to measure cavitation threshold pressures. RESULTS: The mean cavitation threshold was determined in both cases to be indistinguishable from the degassed water control, between 6-8 MPa for high duty-cycle pulsing (CW) and between 25.5-26.5 MPa for very low duty-cycle pulsing. CONCLUSION: The findings of this study indicate that an IBCM of PMAA-FeOX nanoparticles is a possible solution to reducing MRI interference from the coupling bath without increasing the risk of prefocal cavitation.


Asunto(s)
Acústica , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Probabilidad , Agua , Espectroscopía de Resonancia Magnética
4.
MAGMA ; 36(6): 857-867, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37665502

RESUMEN

OBJECTIVE: To develop two spiral-based bSSFP pulse sequences combined with L + S reconstruction for accelerated ungated, free-breathing dynamic cardiac imaging at 1.5 T. MATERIALS AND METHODS: Tiny golden angle rotated spiral-out and spiral-in/out bSSFP sequences combined with view-sharing (VS), compressed sensing (CS), and low-rank plus sparse (L + S) reconstruction were evaluated and compared via simulation and in vivo dynamic cardiac imaging studies. The proposed methods were then validated against the standard cine, in terms of quantitative image assessment and qualitative quality rating. RESULTS: The L + S method yielded the least residual artifacts and the best image sharpness among the three methods. Both spiral cine techniques showed clinically diagnostic images (score > 3). Compared to standard cine, there were significant differences in global image quality and edge sharpness for spiral cine techniques, while there was significant difference in image contrast for the spiral-out cine but no significant difference for the spiral-in/out cine. There was good agreement in left ventricular ejection fraction for both the spiral-out cine (- 1.6 [Formula: see text] 3.1%) and spiral-in/out cine (- 1.5 [Formula: see text] 2.8%) against standard cine. DISCUSSION: Compared to the time-consuming standard cine (~ 5 min) which requires ECG-gating and breath-holds, the proposed spiral bSSFP sequences achieved ungated, free-breathing cardiac movies at a similar spatial (1.5 × 1.5 × 8 mm3) and temporal resolution (36 ms) per slice for whole heart coverage (10-15 slices) within 45 s, suggesting the clinical potential for improved patient comfort or for imaging patients with arrhythmias or who cannot hold their breath.


Asunto(s)
Corazón , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Humanos , Contencion de la Respiración , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Reproducibilidad de los Resultados , Volumen Sistólico
5.
Magn Reson Imaging ; 103: 169-178, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37543175

RESUMEN

Current FDA-approved transcranial MR-guided focused ultrasound (tcMRgFUS) transducers cause a curved dark band in 3 T brain images that runs through midbrain targets of ablative treatments for essential tremor and other applications, and signal is reduced by at least 25% elsewhere in the brain. This limits the set of scans that can be performed to guide and assess the effects of treatment. An electromagnetic simulation study was performed to elucidate the mechanisms causing the dark band. Based on the results, a pair of passive antennas in a "propeller-beanie" configuration were designed to manipulate the reflected waves to avoid signal cancellation within the brain. The antennas were optimized and validated with in-vivo experiments and hydrophone measurements. The simulation study revealed that the dark band is caused by RF waves reflected from the transducer's ground plane, which cancel with incoming waves from the scanner's body coil. The passive antennas shifted the dark band out of the brain and increased transmit efficiency in the center of brain 2.3 times while improving field homogeneity by 50%. They also increased receive sensitivity and SNR in anatomic and temperature imaging. They caused no detectable distortion in hydrophone-measured focal pressure profiles. The conductive ground planes and coupling media used in tcMRgFUS and other piezoelectric FUS transducers interact with a 3 T scanner's RF fields to reduce transmit efficiency and SNR. For tcMRgFUS scenario, "propeller beanie" passive reflecting antennas alleviated these effects. This could make a broader set of imaging sequences available to guide tcMRgFUS treatment.


Asunto(s)
Artefactos , Temblor Esencial , Humanos , Encéfalo/diagnóstico por imagen , Ultrasonografía , Fantasmas de Imagen , Imagen por Resonancia Magnética/métodos
6.
MAGMA ; 36(3): 465-475, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37306784

RESUMEN

OBJECTIVE: Diagnostic-quality neuroimaging methods are vital for widespread clinical adoption of low field MRI. Spiral imaging is an efficient acquisition method that can mitigate the reduced signal-to-noise ratio at lower field strengths. As concomitant field artifacts are worse at lower field, we propose a generalizable quadratic gradient-field nulling as an echo-to-echo compensation and apply it to spiral TSE at 0.55 T. MATERIALS AND METHODS: A spiral in-out TSE acquisition was developed with a compensation for concomitant field variation between spiral interleaves, by adding bipolar gradients around each readout to minimize phase differences at each refocusing pulse. Simulations were performed to characterize concomitant field compensation approaches. We demonstrate our proposed compensation method in phantoms and (n = 8) healthy volunteers at 0.55 T. RESULTS: Spiral read-outs with integrated spoiling demonstrated strong concomitant field artifacts but were mitigated using the echo-to-echo compensation. Simulations predicted a decrease of concomitant field phase RMSE between echoes of 42% using the proposed compensation. Spiral TSE improved SNR by 17.2 ± 2.3% compared to reference Cartesian acquisition. DISCUSSION: We demonstrated a generalizable approach to mitigate concomitant field artifacts for spiral TSE acquisitions via the addition of quadratic-nulling gradients, which can potentially improve neuroimaging at low-field through increased acquisition efficiency.


Asunto(s)
Encéfalo , Aumento de la Imagen , Humanos , Aumento de la Imagen/métodos , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Relación Señal-Ruido , Artefactos
7.
Med Sci Sports Exerc ; 55(10): 1913-1922, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37259254

RESUMEN

INTRODUCTION: Athletes use their skeletal muscles to demonstrate performance. Muscle force generating capacity is correlated with volume, meaning that variations in sizes of different muscles may be indicative of how athletes meet different demands in their sports. Medical imaging enables in vivo quantification of muscle volumes; however, muscle volume distribution has not been compared across athletes of different sports. PURPOSE: The goal of this work was to define "muscular phenotypes" in athletes of different sports and compare these using hierarchical clustering. METHODS: Muscle volumes normalized by body mass of athletes (football, baseball, basketball, or track) were compared with control participants to quantify size differences using z -scores. z -Scores of 35 muscles described the pattern of volume deviation within each athlete's lower limb, characterizing their muscular phenotype. Data-driven high-dimensional clustering analysis was used to group athletes presenting similar phenotypes. Efficacy of clustering to identify similar phenotypes was demonstrated by grouping athletes' contralateral limbs before other athletes' limbs. RESULTS: Analyses revealed that athletes did not tend to cluster with others competing in the same sport. Basketball players with similar phenotypes grouped by clustering also demonstrated similarities in performance. Clustering also identified muscles with similar volume variation patterns across athletes, and principal component analysis revealed specific muscles that accounted for most of the variance (gluteus maximus, sartorius, semitendinosus, vastus medialis, vastus lateralis, and rectus femoris). CONCLUSIONS: Athletes exhibit heterogeneous lower limb muscle volumes that can be characterized and compared as individual muscular phenotypes. Clustering revealed that athletes with the most similar phenotypes do not always play the same sport such that patterns of muscular heterogeneity across a group of athletes reflect factors beyond their specific sports.


Asunto(s)
Baloncesto , Extremidad Inferior , Humanos , Extremidad Inferior/fisiología , Músculo Cuádriceps/fisiología , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiología , Atletas , Baloncesto/fisiología
8.
Magn Reson Med ; 90(2): 552-568, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37036033

RESUMEN

PURPOSE: To develop 2D turbo spin-echo (TSE) imaging using annular spiral rings (abbreviated "SPRING-RIO TSE") with compensation of concomitant gradient fields and B0 inhomogeneity at both 0.55T and 1.5T for fast T2 -weighted imaging. METHODS: Strategies of gradient waveform modifications were implemented in SPRING-RIO TSE for compensation of self-squared concomitant gradient terms at the TE and across echo spacings, along with reconstruction-based corrections to simultaneously compensate for the residual concomitant gradient and B0 field induced phase accruals along the readout. The signal pathway disturbance caused by time-varying and spatially dependent concomitant fields was simulated, and echo-to-echo phase variations before and after sequence-based compensation were compared. Images from SPRING-RIO TSE with no compensation, with compensation, and Cartesian TSE were also compared via phantom and in vivo acquisitions. RESULTS: Simulation showed how concomitant fields affected the signal evolution with no compensation, and both simulation and phantom studies demonstrated the performance of the proposed sequence modifications, as well as the readout off-resonance corrections. Volunteer data showed that after full correction, the SPRING-RIO TSE sequence achieved high image quality with improved SNR efficiency (15%-20% increase), and reduced RF SAR (˜50% reduction), compared to the standard Cartesian TSE, presenting potential benefits, especially in regaining SNR at low-field (0.55T). CONCLUSION: Implementation of SPRING-RIO TSE with concomitant field compensation was tested at 0.55T and 1.5T. The compensation principles can be extended to correct for other trajectory types that are time-varying along the echo train and temporally asymmetric in TSE-based imaging.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Aumento de la Imagen/métodos , Fantasmas de Imagen , Fenómenos Magnéticos
9.
Z Med Phys ; 2023 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-37019739

RESUMEN

PURPOSE: To provide a robust whole-brain quantitative magnetization transfer (MT) imaging method that is not limited by long acquisition times. METHODS: Two variants of a spiral 2D interleaved multi-slice spoiled gradient echo (SPGR) sequence are used for rapid quantitative MT imaging of the brain at 3 T. A dual flip angle, steady-state prepared, double-contrast method is used for combined B1 and-T1 mapping in combination with a single-contrast MT-prepared acquisition over a range of different saturation flip angles (50 deg to 850 deg) and offset frequencies (1 kHz and 10 kHz). Five sets (containing minimum 6 to maximum 18 scans) with different MT-weightings were acquired. In addition, main magnetic field inhomogeneities (ΔB0) were measured from two Cartesian low-resolution 2D SPGR scans with different echo times. Quantitative MT model parameters were derived from all sets using a two-pool continuous-wave model analysis, yielding the pool-size ratio, F, their exchange rate, kf, and their transverse relaxation time, T2r. RESULTS: Whole-brain quantitative MT imaging was feasible for all sets with total acquisition times ranging from 7:15 min down to 3:15 min. For accurate modeling, B1-correction was essential for all investigated sets, whereas ΔB0-correction showed limited bias for the observed maximum off-resonances at 3 T. CONCLUSION: The combination of rapid B1-T1 mapping and MT-weighted imaging using a 2D multi-slice spiral SPGR research sequence offers excellent prospects for rapid whole-brain quantitative MT imaging in the clinical setting.

10.
Vasc Med ; 28(4): 282-289, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37093712

RESUMEN

BACKGROUND: The distal superficial femoral artery (SFA) is most commonly affected in peripheral artery disease (PAD). The effects of the proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitor alirocumab added to statin therapy on SFA atherosclerosis, downstream flow, and walking performance are unknown. METHODS: Thirty-five patients with PAD on maximally tolerated statin therapy were recruited. Patients were randomized to alirocumab 150 mg subcutaneously (n = 18) or matching placebo (n = 17) therapy every 2 weeks for 1 year. The primary outcome was change in SFA plaque volume by black blood magnetic resonance imaging (MRI). Secondary outcomes were changes in calf muscle perfusion by cuff/occlusion hyperemia arterial spin labeling MRI, 6-minute walk distance (6MWD), low-density lipoprotein (LDL) cholesterol, and other biomarkers. RESULTS: Age (mean ± SD) was 64 ± 8 years, 20 (57%) patients were women, 17 (49%) were Black individuals, LDL was 107 ± 36 mg/dL, and the ankle-brachial index 0.71 ± 0.20. The LDL fell more with alirocumab than placebo (mean [95% CI]) (-49.8 [-66.1 to -33.6] vs -7.7 [-19.7 to 4.3] mg/dL; p < 0.0001). Changes in SFA plaque volume and calf perfusion showed no difference between groups when adjusted for baseline (+0.25 [-0.29 to 0.79] vs -0.04 [-0.47 to 0.38] cm3; p = 0.37 and 0.22 [-8.67 to 9.11] vs 3.81 [-1.45 to 9.08] mL/min/100 g; p = 0.46, respectively), nor did 6MWD. CONCLUSION: In this exploratory study, the addition of alirocumab therapy to statins did not alter SFA plaque volume, calf perfusion or 6MWD despite significant LDL lowering. Larger studies with longer follow up that include plaque characterization may improve understanding of the effects of intensive LDL-lowering therapy in PAD (ClinicalTrials.gov Identifier: NCT02959047).


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Enfermedad Arterial Periférica , Placa Aterosclerótica , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Proproteína Convertasa 9/uso terapéutico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Anticuerpos Monoclonales/efectos adversos , LDL-Colesterol/uso terapéutico , Placa Aterosclerótica/inducido químicamente , Placa Aterosclerótica/tratamiento farmacológico , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/tratamiento farmacológico , Músculos , Resultado del Tratamiento , Método Doble Ciego
11.
Magn Reson Med ; 89(6): 2255-2263, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36669874

RESUMEN

PURPOSE: To develop and test compressed sensing-based multiframe 3D MRI of grid-tagged hyperpolarized gas in the lung. THEORY AND METHODS: Applying grid-tagging RF pulses to inhaled hyperpolarized gas results in images in which signal intensity is predictably and sparsely distributed. In the present work, this phenomenon was used to produce a sampling pattern in which k-space is undersampled by a factor of approximately seven, yet regions of high k-space energy remain densely sampled. Three healthy subjects received multiframe 3D 3 He tagging MRI using this undersampling method. Images were collected during a single exhalation at eight timepoints spanning the breathing cycle from end-of-inhalation to end-of-exhalation. Grid-tagged images were used to generate 3D displacement maps of the lung during exhalation, and time-resolved maps of principal strains and fractional volume change were generated from these displacement maps using finite-element analysis. RESULTS: Tags remained clearly resolvable for 4-6 timepoints (5-8 s) in each subject. Displacement maps revealed noteworthy temporal and spatial nonlinearities in lung motion during exhalation. Compressive normal strains occurred along all three principal directions but were primarily oriented in the head-foot direction. Fractional volume changes displayed clear bilateral symmetry, but with the lower lobes displaying slightly higher change than the upper lobes in 2 of the 3 subjects. CONCLUSION: We developed a compressed sensing-based method for multiframe 3D MRI of grid-tagged hyperpolarized gas in the lung during exhalation. This method successfully overcomes previous challenges for 3D dynamic grid-tagging, allowing time-resolved biomechanical readouts of lung function to be generated.


Asunto(s)
Compresión de Datos , Pulmón , Masculino , Humanos , Pulmón/diagnóstico por imagen , Respiración , Imagen por Resonancia Magnética/métodos
12.
Med Phys ; 49(12): 7373-7383, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36156266

RESUMEN

PURPOSE: In this study, we examine the effects of a recently developed, iron-based coupling medium (IBCM) on guidance magnetic resonance (MR) scans during transcranial, magnetic-resonance-guided, focused ultrasound surgery (tMRgFUS) procedures. More specifically, this study tests the hypotheses that the use of the IBCM will (a) not adversely affect image quality, (b) remove aliasing from small field-of-view scans, and (c) decouple image quality from the motion state of the coupling fluid. METHODS: An IBCM, whose chemical synthesis and characterization are reported elsewhere, was used as a coupling medium during tMRgFUS procedures on gel phantoms. Guidance magnetization-prepared rapid-gradient-echo (MP-RAGE), TSE, and GRE scans were acquired with fields of view of 28 and 18 cm. Experiments were repeated with the IBCM in several distinct flow states. GRE scans were used to estimate temperature time courses as a gel target was insonated. IBCM performance was measured by computing (i) the root mean square difference (RMSD) of TSE and GRE pixel values acquired using water and the IBCM, relative to the use of water; (ii) through-time temperature uncertainty for GRE scans; and (iii) Bland-Altman analysis of the temperature time courses. Finally, guidance TSE and GRE scans of a human volunteer were acquired during a separate sham tMRgFUS procedure. As a control, all experiments were repeated using a water coupling medium. RESULTS: Use of the IBCM reduced RMSD in TSE scans by a factor of 4 or more for all fields of view and nonstationary motion states, but did not reduce RMSD estimates in MP-RAGE scans. With the coupling media in a stationary state, the IBCM altered estimates of temperature uncertainty relative to the use of water by less than 0.2°C. However, with a high flow state, the IBCM reduced temperature uncertainties by the statistically significant amounts (at the 0.01 level) of 0.5°C (28 cm field of view) and 5°C (18 cm field of view). Bland-Altman analyses found a 0.1°C ± 0.5°C difference between temperature estimates acquired using water and the IBCM as coupling media. Finally, scans of a human volunteer using the IBCM indicate more conspicuous grey/white matter contrast, a reduction in aliasing, and a less than 0.2°C change in temperature uncertainty. CONCLUSIONS: The use of an IBCM during tMRgFUS procedures does not adversely affect image quality for TSE and GRE scans, can decouple image quality from the motion state of the coupling fluid, and can remove aliasing from scans where the field of view is set to be much smaller than the spatial extent of the coupling fluid.


Asunto(s)
Hierro , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Temperatura , Agua , Medios de Contraste
13.
Sci Rep ; 12(1): 13407, 2022 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-35927449

RESUMEN

Transcranial focused ultrasound with the InSightec Exablate system uses thermal ablation for the treatment of movement and mood disorders and blood brain barrier disruption for tumor therapy. The system uses computed tomography (CT) images to calculate phase corrections that account for aberrations caused by the human skull. This work investigates whether magnetic resonance (MR) images can be used as an alternative to CT images to calculate phase corrections. Phase corrections were calculated using the gold standard hydrophone method and the standard of care InSightec ray tracing method. MR binary image mask, MR-simulated-CT (MRsimCT), and CT images of three ex vivo human skulls were supplied as inputs to the InSightec ray tracing method. The degassed ex vivo human skulls were sonicated with a 670 kHz hemispherical phased array transducer (InSightec Exablate 4000). 3D raster scans of the beam profiles were acquired using a hydrophone mounted on a 3-axis positioner system. Focal spots were evaluated using six metrics: pressure at the target, peak pressure, intensity at the target, peak intensity, positioning error, and focal spot volume. Targets at the geometric focus and 5 mm lateral to the geometric focus were investigated. There was no statistical difference between any of the metrics at either target using either MRsimCT or CT for phase aberration correction. As opposed to the MRsimCT, the use of CT images for aberration correction requires registration to the treatment day MR images; CT misregistration within a range of ± 2 degrees of rotation error along three dimensions was shown to reduce focal spot intensity by up to 9.4%. MRsimCT images used for phase aberration correction for the skull produce similar results as CT-based correction, while avoiding both CT to MR registration errors and unnecessary patient exposure to ionizing radiation.


Asunto(s)
Cráneo , Tomografía Computarizada por Rayos X , Cabeza , Humanos , Imagen por Resonancia Magnética/métodos , Cráneo/diagnóstico por imagen , Cráneo/patología , Tomografía Computarizada por Rayos X/métodos
14.
Circ Cardiovasc Imaging ; 15(7): e013869, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35861977

RESUMEN

BACKGROUND: Peripheral artery disease (PAD) results in exercise-induced ischemia in leg muscles. 31Phosphorus (P) magnetic resonance spectroscopy demonstrates prolonged phosphocreatine recovery time constant after exercise in PAD but has low signal to noise, low spatial resolution, and requires multinuclear hardware. Chemical exchange saturation transfer (CEST) is a quantitative magnetic resonance imaging method for imaging substrate (CEST asymmetry [CESTasym]) concentration by muscle group. We hypothesized that kinetics measured by CEST could distinguish between patients with PAD and controls. METHODS: Patients with PAD and age-matched normal subjects were imaged at 3T with a transmit-receive coil around the calf. Four CEST mages were acquired over 24-second intervals. The subjects then performed plantar flexion exercise on a magnetic resonance imaging-compatible ergometer until calf exhaustion. Twenty-five CEST images were obtained at end exercise. Regions of interest were drawn around individual muscle groups, and (CESTasym) decay times were fitted by exponential curve to CEST values. In 10 patients and 11 controls, 31P spectra were obtained 20 minutes later after repeat exercise. Five patients and 5 controls returned at a mean of 1±1 days later for repeat CEST studies. RESULTS: Thirty-five patients with PAD (31 male, age 66±8 years) and 29 controls (11 male, age 63±8 years) were imaged with CEST. The CESTasym decay times for the whole calf (341±332 versus 153±72 seconds; P<0.03) as well as for the gastrocnemius and posterior tibialis were longer in patients with PAD. Agreement between CESTasym decay and phosphocreatine recovery time constant was good. CONCLUSIONS: CEST is a magnetic resonance imaging method that can distinguish energetics in patients with PAD from age-matched normal subjects on a per muscle group basis. CEST agrees reasonably well with the gold standard 31P magnetic resonance spectroscopy. Moreover, CEST has higher spatial resolution, creates an image, and does not require multinuclear hardware and thus may be more suitable for clinical studies in PAD.


Asunto(s)
Pierna , Enfermedad Arterial Periférica , Anciano , Humanos , Pierna/irrigación sanguínea , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Músculo Esquelético , Enfermedad Arterial Periférica/diagnóstico por imagen , Fosfocreatina
15.
Magn Reson Med ; 88(2): 601-616, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35394088

RESUMEN

PURPOSE: To develop a new approach to 2D turbo spin -echo (TSE) imaging using annular spiral rings with a retraced in/out trajectory, dubbed "SPRING-RIO TSE", for fast T2 -weighted brain imaging at 3T. METHODS: A long spiral trajectory was split into annular segmentations that were then incorporated into a 2D TSE acquisition module to fully exploit the sampling efficiency of spiral rings. A retraced in/out trajectory strategy coupled with spiral-ring TSE was introduced to increase SNR, mitigate T2 -decay induced artifacts, and self-correct moderate off-resonance while maintaining the target TE and causing no scan time penalty. Model-based k-space estimation and semiautomatic off-resonance correction algorithms were implemented to minimize effects of k-space trajectory infidelity and B0 inhomogeneity, respectively. The resulting SPRING-RIO TSE method was compared to the original spiral-ring (abbreviated "SPRING") TSE and Cartesian TSE using simulations, and phantom and in vivo acquisitions. RESULTS: Simulation and phantom studies demonstrated the performance of the proposed SPRING-RIO TSE pulses sequence, as well as that of trajectory correction and off-resonance correction. Volunteer data showed that the proposed method achieves high-quality 2D T2 -weighted brain imaging with a higher scan efficiency (0:45 min/14 slices versus 1:31 min/14 slices), improved image contrast, and reduced specific absorption rate compared to conventional 2D Cartesian TSE. CONCLUSION: 2D T2 -weighted brain imaging using spiral-ring TSE was implemented and tested, providing several potential advantages over conventional 2D Cartesian TSE imaging.


Asunto(s)
Aumento de la Imagen , Imagen por Resonancia Magnética , Artefactos , Encéfalo/diagnóstico por imagen , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos
16.
Magn Reson Imaging ; 80: 106-112, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33957210

RESUMEN

PURPOSE: To develop a real-time dynamic vocal tract imaging method using an accelerated spiral GRE sequence and low rank plus sparse reconstruction. METHODS: Spiral k-space sampling has high data acquisition efficiency and thus is suited for real-time dynamic imaging; further acceleration can be achieved by undersampling k-space and using a model-based reconstruction. Low rank plus sparse reconstruction is a promising method with fast computation and increased robustness to global signal changes and bulk motion, as the images are decomposed into low rank and sparse terms representing different dynamic components. However, the combination with spiral scanning has not been well studied. In this study an accelerated spiral GRE sequence was developed with an optimized low rank plus sparse reconstruction and compared with L1-SPIRiT and XD-GRASP methods. The off-resonance was also corrected using a Chebyshev approximation method to reduce blurring on a frame-by-frame basis. RESULTS: The low rank plus sparse reconstruction method is sensitive to the weights of the low rank and sparse terms. The optimized reconstruction showed advantages over other methods with reduced aliasing and improved SNR. With the proposed method, spatial resolution of 1.3*1.3 mm2 with 150 mm field-of-view (FOV) and temporal resolution of 30 frames-per-second (fps) was achieved with good image quality. Blurring was reduced using the Chebyshev approximation method. CONCLUSION: This work studies low rank plus sparse reconstruction using the spiral trajectory and demonstrates a new method for dynamic vocal tract imaging which can benefit studies of speech disorders.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Algoritmos , Humanos , Movimiento (Física)
17.
Magn Reson Med ; 86(4): 2095-2104, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34021628

RESUMEN

PURPOSE: To use deep learning for suppression of the artifact-generating T1 -relaxation echo in cine displacement encoding with stimulated echoes (DENSE) for the purpose of reducing the scan time. METHODS: A U-Net was trained to suppress the artifact-generating T1 -relaxation echo using complementary phase-cycled data as the ground truth. A data-augmentation method was developed that generates synthetic DENSE images with arbitrary displacement-encoding frequencies to suppress the T1 -relaxation echo modulated for a range of frequencies. The resulting U-Net (DAS-Net) was compared with k-space zero-filling as an alternative method. Non-phase-cycled DENSE images acquired in shorter breath-holds were processed by DAS-Net and compared with DENSE images acquired with phase cycling for the quantification of myocardial strain. RESULTS: The DAS-Net method effectively suppressed the T1 -relaxation echo and its artifacts, and achieved root Mean Square(RMS) error = 5.5 ± 0.8 and structural similarity index = 0.85 ± 0.02 for DENSE images acquired with a displacement encoding frequency of 0.10 cycles/mm. The DAS-Net method outperformed zero-filling (root Mean Square error = 5.8 ± 1.5 vs 13.5 ± 1.5, DAS-Net vs zero-filling, P < .01; and structural similarity index = 0.83 ± 0.04 vs 0.66 ± 0.03, DAS-Net vs zero-filling, P < .01). Strain data for non-phase-cycled DENSE images with DAS-Net showed close agreement with strain from phase-cycled DENSE. CONCLUSION: The DAS-Net method provides an effective alternative approach for suppression of the artifact-generating T1 -relaxation echo in DENSE MRI, enabling a 42% reduction in scan time compared to DENSE with phase-cycling.


Asunto(s)
Artefactos , Aprendizaje Profundo , Contencion de la Respiración , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética
18.
J Magn Reson Imaging ; 54(4): 1268-1279, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33822426

RESUMEN

BACKGROUND: Variable density spiral (VDS) pulse sequences with motion compensated compressed sensing (MCCS) reconstruction allow for whole-heart quantitative assessment of myocardial perfusion but are not clinically validated. PURPOSE: Assess performance of whole-heart VDS quantitative stress perfusion with MCCS to detect obstructive coronary artery disease (CAD). STUDY TYPE: Prospective cross sectional. POPULATION: Twenty-five patients with chest pain and known or suspected CAD and nine normal subjects. FIELD STRENGTH/SEQUENCE: Segmented steady-state free precession (SSFP) sequence, segmented phase sensitive inversion recovery sequence for late gadolinium enhancement (LGE) imaging and VDS sequence at 1.5 T for rest and stress quantitative perfusion at eight short-axis locations. ASSESSMENT: Stenosis was defined as ≥50% by quantitative coronary angiography (QCA). Visual and quantitative analysis of MRI data was compared to QCA. Quantitative analysis assessed average myocardial perfusion reserve (MPR), average stress myocardial blood flow (MBF), and lowest stress MBF of two contiguous myocardial segments. Ischemic burden was measured visually and quantitatively. STATISTICAL TESTS: Student's t-test, McNemar's test, chi-square statistic, linear mixed-effects model, and area under receiver-operating characteristic curve (ROC). RESULTS: Per-patient visual analysis demonstrated a sensitivity of 84% (95% confidence interval [CI], 60%-97%) and specificity of 83% [95% CI, 36%-100%]. There was no significant difference between per-vessel visual and quantitative analysis for sensitivity (69% [95% CI, 51%-84%] vs. 77% [95% CI, 60%-90%], P = 0.39) and specificity (88% [95% CI, 73%-96%] vs. 80% [95% CI, 64%-91%], P = 0.75). Per-vessel quantitative analysis ROC showed no significant difference (P = 0.06) between average MPR (0.68 [95% CI, 0.56-0.81]), average stress MBF (0.74 [95% CI, 0.63-0.86]), and lowest stress MBF (0.79 [95% CI, 0.69-0.90]). Visual and quantitative ischemic burden measurements were comparable (P = 0.85). DATA CONCLUSION: Whole-heart VDS stress perfusion demonstrated good diagnostic accuracy and ischemic burden evaluation. No significant difference was seen between visual and quantitative diagnostic performance and ischemic burden measurements. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Adenosina , Medios de Contraste , Estudios Transversales , Gadolinio , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Estudios Prospectivos
19.
J Cardiovasc Magn Reson ; 23(1): 20, 2021 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-33691739

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) cine displacement encoding with stimulated echoes (DENSE) measures heart motion by encoding myocardial displacement into the signal phase, facilitating high accuracy and reproducibility of global and segmental myocardial strain and providing benefits in clinical performance. While conventional methods for strain analysis of DENSE images are faster than those for myocardial tagging, they still require manual user assistance. The present study developed and evaluated deep learning methods for fully-automatic DENSE strain analysis. METHODS: Convolutional neural networks (CNNs) were developed and trained to (a) identify the left-ventricular (LV) epicardial and endocardial borders, (b) identify the anterior right-ventricular (RV)-LV insertion point, and (c) perform phase unwrapping. Subsequent conventional automatic steps were employed to compute strain. The networks were trained using 12,415 short-axis DENSE images from 45 healthy subjects and 19 heart disease patients and were tested using 10,510 images from 25 healthy subjects and 19 patients. Each individual CNN was evaluated, and the end-to-end fully-automatic deep learning pipeline was compared to conventional user-assisted DENSE analysis using linear correlation and Bland Altman analysis of circumferential strain. RESULTS: LV myocardial segmentation U-Nets achieved a DICE similarity coefficient of 0.87 ± 0.04, a Hausdorff distance of 2.7 ± 1.0 pixels, and a mean surface distance of 0.41 ± 0.29 pixels in comparison with manual LV myocardial segmentation by an expert. The anterior RV-LV insertion point was detected within 1.38 ± 0.9 pixels compared to manually annotated data. The phase-unwrapping U-Net had similar or lower mean squared error vs. ground-truth data compared to the conventional path-following method for images with typical signal-to-noise ratio (SNR) or low SNR (p < 0.05), respectively. Bland-Altman analyses showed biases of 0.00 ± 0.03 and limits of agreement of - 0.04 to 0.05 or better for deep learning-based fully-automatic global and segmental end-systolic circumferential strain vs. conventional user-assisted methods. CONCLUSIONS: Deep learning enables fully-automatic global and segmental circumferential strain analysis of DENSE CMR providing excellent agreement with conventional user-assisted methods. Deep learning-based automatic strain analysis may facilitate greater clinical use of DENSE for the quantification of global and segmental strain in patients with cardiac disease.


Asunto(s)
Aprendizaje Profundo , Cardiopatías/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Función Ventricular Derecha , Automatización , Estudios de Casos y Controles , Cardiopatías/fisiopatología , Humanos , Londres , Valor Predictivo de las Pruebas , Estados Unidos
20.
Magn Reson Med ; 86(2): 648-662, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33709415

RESUMEN

PURPOSE: To develop and evaluate a high spatial resolution (1.25 × 1.25 mm2 ) spiral first-pass myocardial perfusion imaging technique with whole-heart coverage at 3T, to better assess transmural differences in perfusion between the endocardium and epicardium, to quantify the myocardial ischemic burden, and to improve the detection of obstructive coronary artery disease. METHODS: Whole-heart high-resolution spiral perfusion pulse sequences and corresponding motion-compensated reconstruction techniques for both interleaved single-slice (SS) and simultaneous multi-slice (SMS) acquisition with or without outer-volume suppression (OVS) were developed. The proposed techniques were evaluated in 34 healthy volunteers and 8 patients (55 data sets). SS and SMS images were reconstructed using motion-compensated L1-SPIRiT and SMS-Slice-L1-SPIRiT, respectively. Images were blindly graded by 2 experienced cardiologists on a 5-point scale (5, excellent; 1, poor). RESULTS: High-quality perfusion imaging was achieved for both SS and SMS acquisitions with or without OVS. The SS technique without OVS had the highest scores (4.5 [4, 5]), which were greater than scores for SS with OVS (3.5 [3.25, 3.75], P < .05), MB = 2 without OVS (3.75 [3.25, 4], P < .05), and MB = 2 with OVS (3.75 [2.75, 4], P < .05), but significantly higher than those for MB = 3 without OVS (4 [4, 4], P = .95). SMS image quality was improved using SMS-Slice-L1-SPIRiT as compared to SMS-L1-SPIRiT (P < .05 for both reviewers). CONCLUSION: We demonstrated the successful implementation of whole-heart spiral perfusion imaging with high resolution at 3T. Good image quality was achieved, and the SS without OVS showed the best image quality. Evaluation in patients with expected ischemic heart disease is warranted.


Asunto(s)
Imagen de Perfusión Miocárdica , Humanos , Procesamiento de Imagen Asistido por Computador , Movimiento (Física) , Imagen de Perfusión , Pericardio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA