Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 17(11): 1311-1321, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38795093

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.


Asunto(s)
Anticoagulantes , Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Contraindicaciones de los Medicamentos , Accidente Cerebrovascular Isquémico , Sistema de Registros , Humanos , Apéndice Atrial/fisiopatología , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/terapia , Femenino , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/administración & dosificación , Anciano , Factores de Riesgo , Medición de Riesgo , Anciano de 80 o más Años , Factores de Tiempo , Administración Oral , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular Isquémico/mortalidad , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/etiología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Insuficiencia del Tratamiento , Hemorragia/inducido químicamente , Recurrencia , Persona de Mediana Edad , Estudios Retrospectivos , Europa (Continente)
2.
Expert Rev Med Devices ; 21(3): 187-196, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38155555

RESUMEN

INTRODUCTION: Over the last two decades, mitral transcatheter edge-to-edge repair (M-TEER) has become a safe and effective therapy for severe mitral regurgitation in patients deemed at high surgical risk. AREAS COVERED: This review aims to encompass the most relevant and updated evidence in the field of M-TEER from its inception, focusing on clinical and anatomical features for proper patient and device selection. EXPERT OPINION: Growing operator experience and device iterations have resulted in improved clinical outcomes and an expansion of the therapy to patients with complex anatomies and clinical scenarios. Future investigations are warranted to determine the best management options and the most suitable device for every patient with MR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Selección de Paciente , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
3.
Expert Rev Cardiovasc Ther ; 21(10): 703-712, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37815845

RESUMEN

INTRODUCTION: With the expanding indications of transcatheter aortic valve replacement (TAVR) to younger and low-risk patients, the life expectancy of patients currently undergoing TAVR will likely outlive the durability of transcatheter bioprosthesis. Consequently, the number of failed transcatheter bioprosthesis requiring surgical valve explant or redo TAVR is expected to increase. AREAS COVERED: The aim of this review is to provide an updated overview of redo TAVR for treating degenerated transcatheter bioprosthesis, focusing on pre-procedural planning, potential challenges of coronary reaccess during TAVR-in-TAVR and main outcomes of TAVR explant and redo TAVR. EXPERT OPINION: Patient-tailored device selection and individualized implantation height should be carefully assessed during the index TAVR procedure (weighting between pacemaker avoidance and the potential risk of coronary occlusion in future TAVR-in-TAVR). Future prospective studies comparing safety and clinical outcomes between redo TAVR vs TAVR explant are eagerly awaited.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo
4.
J Clin Med ; 12(18)2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37762965

RESUMEN

Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for patients aged ≥75 years with severe aortic stenosis. Preoperative anemia is present in a large proportion of patients and may increase the risk of post-procedural complications. The purpose of this prognostic systematic review was to analyze the impact of baseline anemia on short- and mid-term outcomes following TAVR. A computerized search was performed on PubMed and Web of Science databases for studies published between January 2013 and December 2022. Primary outcomes were 30-day need for transfusion, acute renal failure, 30-day and mid-term mortality, and readmission during the first year post-TAVR. Data were analyzed via random effects model using inverse variance method with 95% confidence intervals. Eleven observational studies met our eligibility criteria and included a total of 12,588 patients. The prevalence of baseline anemia ranged between 39% and 72%, with no relevant sex differences. Patients with preprocedural anemia received more blood transfusions [OR: 2.95 (2.13-4.09)]), and exhibited increased rates of acute kidney injury [OR:1.74 (1.45-2.10)], short-term mortality [OR: 1.47 (1.07-2.01], and mid-term [OR: 1.89 (1.58-2.25)] mortality following TAVR compared with those without anemia. Baseline anemia determined an increased risk for blood transfusion, acute kidney injury, and short/mid-term mortality among TAVR recipients.

6.
EuroIntervention ; 19(5): e442-e449, 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37128805

RESUMEN

BACKGROUND: Data regarding the safety and long-term effectiveness of percutaneous closure of paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) are scarce. AIMS: This study aims to present a large multicentre international experience of percutaneous post-TAVI PVL closure. METHODS: All patients who underwent percutaneous post-TAVI PVL closure in 14 hospitals across Europe and North America between January 2018 and October 2022 were included. RESULTS: Overall, 45 patients (64% male) were enrolled. The median age was 80 years (75-84). Among them, 67% and 33% had self-expanding and balloon-expandable valve implantations, respectively. Baseline post-TAVI PVL was severe in 67% of cases and moderate in the rest. The time from index TAVI to PVL closure procedure was 16.1 (8.7-34.8) months. Most patients were in NYHA Class III and IV (73%) before the procedure, and 40% had referred hospitalisations for heart failure between TAVI and the PVL closure procedure. Successful PVL closure was achieved in 94%, reducing regurgitation to ≤mild in 91% and moderate in the rest. The Amplatzer Valvular Plug III was the most frequently used device (27 cases), followed by the Amplatzer Valvular Plug 4. The incidence of severe adverse events was 11%. None of the patients died during the index hospitalisation. During long-term follow-up (21.7±16.2 months), the all-cause mortality rate was 14%, and patients presented improvement in functional status and a significant reduction in the rate of hospitalisation for heart failure (from 40% to 6%). CONCLUSIONS: Percutaneous PVL closure is a feasible and safe option for treating post-TAVI leaks. Successful PVL reduction to mild or less could be associated with acute and long-lasting improvements in clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Sistema de Registros , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía
7.
Rev Esp Cardiol (Engl Ed) ; 76(10): 767-773, 2023 Oct.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36804557

RESUMEN

INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estudios Prospectivos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Trastorno del Sistema de Conducción Cardíaco , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
9.
Rev Esp Cardiol (Engl Ed) ; 76(1): 25-31, 2023 Jan.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35691867

RESUMEN

INTRODUCTION AND OBJECTIVES: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. METHODS: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. RESULTS: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). CONCLUSIONS: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Anciano , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento
10.
Rev Esp Cardiol (Engl Ed) ; 76(7): 503-510, 2023 Jul.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35934294

RESUMEN

INTRODUCTION AND OBJECTIVES: Transthyretin cardiac amyloidosis (ATTR-CA) patients often have atrial fibrillation and increased bleeding/thrombogenic risks. We aimed to evaluate outcomes of left atrial appendage closure (LAAC) compared with patients without a known diagnosis of CA. METHODS: Comparison at long-term of patients diagnosed with ATTR-CA who underwent LAAC between 2009 and 2020 and those without a known diagnosis of CA. RESULTS: We studied a total of 1159 patients. Forty patients (3.5%) were diagnosed with ATTR-CA; these patients were older and had more comorbidities, higher HAS-BLED and CHA2DS2-VASc scores, and lower left ventricular function. Successful LAAC was achieved in 1137 patients (98.1%) with no differences between groups. Regarding in-hospital and follow-up complications, there were no differences between the groups in ischemic stroke (5% vs 2.5% in those without a known diagnosis of CA; P=.283), hemorrhagic stroke (2.5% and 0.8% in the control group; P=.284), major or minor bleeding. At the 2-year follow-up, there were no significant differences in mortality (ATTR-CA: 20% vs those without known CA: 13.6%, 0.248); however, the at 5-year follow-up, ATTR-CA patients had higher mortality (40% vs 19.2%; P <.001) but this difference was unrelated to hemorrhagic complications or ischemic stroke. CONCLUSIONS: LAAC could reduce the risk of bleeding complications and ischemic cerebrovascular events without increasing the rate of early or mid-term complications. Although long-term survival was impaired in ATTR-CA patients, it was comparable to that of patients without a known diagnosis of CA at the 2-year follow-up, suggesting that LAAC for patients with ATTR-CA might not be futile.


Asunto(s)
Amiloidosis , Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Hemorragia/complicaciones , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Amiloidosis/complicaciones , Amiloidosis/diagnóstico , Resultado del Tratamiento
12.
JACC Case Rep ; 4(11): 666-670, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35677788

RESUMEN

Sinus contrast material retention after transcatheter aortic valve replacement (TAVR) is a rare phenomenon that may reflect an increased risk for thrombotic complications. We present 3 cases of persistent contrast agent retention in the sinus of Valsalva during the TAVR procedure that portend the occurrence of embolic stroke or bioprosthetic valve thrombosis. (Level of Difficulty: Advanced.).

13.
JACC Case Rep ; 4(12): 727-731, 2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35734523

RESUMEN

An 80-year-old woman with mitral valve repair failure was admitted with hemolytic anemia secondary to the impact of a regurgitant jet on the annuloplasty ring. Transcatheter repair to treat both mitral regurgitation and hemolysis was favored because of surgical risk. Transcatheter edge-to-edge repair represents an alternative for treating hemolysis associated with mitral regurgitation. (Level of Difficulty: Advanced.).

15.
EuroIntervention ; 17(11): e944-e952, 2021 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-34219668

RESUMEN

BACKGROUND: Cardiac computed tomography angiography (CCTA) appears to be an appropriate imaging technique for device surveillance after left atrial appendage occlusion (LAAO). However, the available experience is limited. AIMS: The aim of this study was to determine the prevalence, mechanisms and clinical impact of left atrial appendage (LAA) patency and device-related thrombosis (DRT) following LAAO utilising a novel CCTA-based classification. METHODS: Consecutively enrolled patients who underwent LAAO with an AMPLATZER device were followed up with CCTA. Mechanisms and frequency of residual patency were evaluated and correlated with clinical events. Atrial-side device thrombus, device positioning and presence of signs of device stability were also analysed. RESULTS: A total of 137 patients were included. LAA patency was observed in 56.9% (n=78). Mechanisms and frequency of patency were: malapposition of proximal segment of the device lobe (55.1%), peri-device leak (PDL, 34.6%) and fabric permeability (5.8%). Lobe-LAA axis misalignment was the only independent predictor of device patency after LAAO (HR 38.3, 95% CI: 13.6-107.0; p<0.001). After a median follow-up of 638 days, patency was not associated with an increased risk of death (all-cause or cardiovascular death) or cerebral/peripheral embolism regardless of its mechanism. Any degree of hypo-attenuated thickening (HAT) was found in 16.8% (n=23) of patients, of whom 16 (11.7%) had low-grade HAT and 7 (5.1%) had high-grade HAT or definite DRT. Complete sealing was associated with increased rates of low-grade HAT. CONCLUSIONS: LAA patency on CCTA follow-up is a frequent phenomenon due to malapposition of the proximal segment of the device lobe, PDL or fabric permeability. Patency was not associated with adverse outcomes. Low-grade HAT may be related to a benign, uneventful, endothelialisation process favoured by complete LAAO.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Ecocardiografía Transesofágica , Humanos , Prevalencia , Dispositivo Oclusor Septal/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Trombosis/etiología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
J Clin Med ; 10(4)2021 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-33673247

RESUMEN

BACKGROUND AND AIM: Recent randomized data comparing percutaneous mitral valve repair (PMVR) versus optimal medical treatment in patients with functional MR (FMR) seemed to highlight the importance of the learning curve not only for procedural outcomes but also for patient selection. The aim of the study was to compare a contemporary series of patients undergoing PMVR using a second-generation Mitraclip device (Mitraclip NT) with previous cohorts treated with a first-generation system. METHODS: This multicenter study collected individual data from 18 centers between 2012 and 2017. The cohort was divided into three groups according to the use of the first-generation Mitraclip during the first (control-1) or second half (control-2) or the Mitraclip NT system. RESULTS: A total of 545 consecutive patients were included in the study. Among all, 182 (33.3%), 183 (33.3%), and 180 (33.3%) patients underwent mitral repair in the control-1, control-2, and NT cohorts, respectively. Procedural success was achieved in 93.3% of patients without differences between groups. Major adverse events did not statistically differ among groups, but there was a higher rate of pericardial effusion in the control-1 group (4.3%, 0.6%, and 2.6%, respectively; p = 0.025). The composite endpoint of death, surgery, and admission for congestive heart failure (CHF) at 12 months was lower in the NT group (23.5% in control-1, 22.5% in control-2, and 8.3% in the NT group; p = 0.032). CONCLUSIONS: The present paper shows that contemporary clinical outcomes of patients undergoing PMVR with the Mitraclip system have improved over time.

18.
Int J Cardiol ; 319: 78-84, 2020 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-32634500

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) is an accepted strategy for cardioembolic events prevention in patients with non-valvular atrial fibrillation (AF) unsuitable for anticoagulation. However, uncertainties persist regarding the benefit of LAAO in highly-comorbid patients. The aim of this study was to assess the impact of the CHA2DS2-VASc score beyond thromboembolic risk in predicting clinical outcomes in patients undergoing LAAO. METHODS: 160 patients who underwent LAAO were included and categorized into two groups according to their stroke risk (89 with CHA2DS2-VASc >4 vs. 71 with lower risk). The coprimary endpoints were death and stroke at follow-up. Thromboembolic and bleeding events were compared to those predicted from CHA2DS2-VASc and HAS-BLED scores. RESULTS: Over a median follow-up of 679 days, CHA2DS2-VASc >4 was associated with increased all-cause mortality compared with patients with lower thromboembolic risk (HR: 3.23; 95% CI: 1.28-8.19; p < 0.001). However, the rates of stroke after LAAO were not significantly different between risk groups. The observed annual rates of stroke and major bleeding were lower than predicted. CONCLUSIONS: Despite increased long-term mortality in patients with CHA2DS2-VASc >4, LAAO remains beneficial in reducing stroke and bleeding events in high-risk AF patients unsuitable for anticoagulation.


Asunto(s)
Apéndice Atrial , Anticoagulantes , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Humanos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/prevención & control , Tromboembolia/epidemiología , Tromboembolia/etiología , Tromboembolia/prevención & control
19.
Front Physiol ; 11: 264, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32362831

RESUMEN

BACKGROUND: Atrial coronary branch occlusion is a hardly recognizable clinical entity that can promote atrial fibrillation. The low diagnostic accuracy of the ECG could deal with the characteristics of the ischemia-induced changes in local atrial electrograms, but these have not been described. OBJECTIVES: We analyzed the effects of selective acute atrial branch occlusion on local myocardial structure, atrial electrograms, and surface ECG in an experimental model close to human cardiac anatomy and electrophysiology. METHODS: Six anesthetized open-chest anesthetized pigs underwent surgical occlusion of an atrial coronary branch arising from the right coronary artery during 4 h. Atrial electrograms and ECG were simultaneously recorded. One additional pig acted as sham control. In all cases, the hearts were processed for anatomopathological analysis. RESULTS: Atrial branch occlusion induced patchy atrial necrosis with sharp border zone. During the first 30 min of occlusion, atrial electrograms showed progressive R wave enlargement (1.8 ± 0.6 mV vs. 2.5 ± 1.1 mV, p < 0.01), delayed local activation times (28.5 ± 8.9 ms vs. 36.1 ± 16.4 ms, p < 0.01), ST segment elevation (-0.3 ± 0.3 mV vs. 1.0 ± 1.0 mV, p < 0.01), and presence of monophasic potentials. Atrial ST segment elevation decreased after 2 h of occlusion. The electrical border zone was ∼1 mm and expanded over time. After 2 h of occlusion, the ECG showed a decrease in P wave amplitude (from 0.09 ± 0.04 mV to 0.05 ± 0.04 mV after 165 min occlusion, p < 0.05) and duration (64.4 ± 8.0 ms vs. 80.9 ± 12.6 ms, p < 0.01). CONCLUSION: Selective atrial branch occlusion induces patchy atrial infarction and characteristic changes in atrial activation, R/S wave, and ST segment that are not discernible at the ECG. Only indirect changes in P wave amplitude and duration were appreciated in advanced stages of acute coronary occlusion.

20.
Rev Esp Cardiol (Engl Ed) ; 73(1): 28-34, 2020 Jan.
Artículo en Inglés, Español | MEDLINE | ID: mdl-31036510

RESUMEN

INTRODUCTION AND OBJECTIVES: Despite the efficacy of oral anticoagulant (OAC) therapy, some patients continue to have a high residual risk and develop a stroke on OAC therapy (resistant stroke [RS]), and there is a lack of evidence on the management of these patients. The aim of this study was to analyze the safety and efficacy of left atrial appendage occlusion (LAAO) as secondary prevention in patients with nonvalvular atrial fibrillation who have experienced a stroke/transient ischemic attack despite OAC treatment. METHODS: We analyzed data from the Amplatzer Cardiac Plug multicenter registry on 1047 consecutive patients with nonvalvular atrial fibrillation undergoing LAAO. Patientes with previous stroke on OAC therapy as indication for LAAO were identified and compared with patients with other indications. RESULTS: A total of 115 patients (11%) with RS were identified. The CHA2DS2-VASc and the HAS-BLED score were significantly higher in the RS group (respectively 5.5±1.5 vs 4.3±1.6; P <.001; 3.9±1.3 vs 3.1±1.2; P <.001). No significant differences were observed in periprocedural major safety events (7.8 vs 4.5%; P=.1). With a mean clinical follow-up of 16.2±12.2 months, the observed annual stroke/transient ischemic attack rate for the RS group was 2.6% (65% risk reduction) and the observed annual major bleeding rate was 0% (100% risk reduction). CONCLUSIONS: Patients with RS undergoing LAAO showed similar safety outcomes to patients without RS, with a significant reduction in stroke/transient ischemic attack and major bleeding events during follow-up. Adequately powered controlled trials are needed to further investigate the use of LAAO in RS patients.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/terapia , Sistema de Registros , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Administración Oral , Anciano , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco/métodos , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA