Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 13(11): 1092-7, 2002 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-12475098

RESUMEN

INTRODUCTION: Discrimination of ventricular and supraventricular arrhythmias remains one of the major challenges for appropriate implantable defibrillator (ICD) therapy delivery. The electrogram vector timing and correlation (VTC) algorithm was developed for such rhythm discrimination. The VTC algorithm differentiates normally conducted supraventricular beats from abnormally conducted ventricular beats by comparing the timing and correlation of rate and shock channel electrograms. METHODS AND RESULTS: Rate and shock channel electrograms of sinus rhythm and induced arrhythmias were collected from 93 patients during ICD placement. The algorithm was developed using data from 50 patients and prospectively tested in a software model with the remaining 43 patients. A sinus rhythm reference was formed by averaging complexes of the shock channel signal aligned by the peak amplitude of the rate channel. Eight features measuring the amplitude and timing of shock channel signal characteristics were extracted from the reference for comparison. When a high-rate rhythm was detected, the VTC algorithm computed the correlation of the arrhythmia complex features with the reference. Rhythms with a sufficient number of uncorrelated beats were classified as ventricular tachycardia (VT). In a dual-chamber implementation, the VTC algorithm is integrated with ventricular and atrial rate comparison (V>A) and stability above an atrial fibrillation rate threshold. The test set consisted of 117 arrhythmias. Dual-chamber sensitivity was 100% (81/81 VT) and specificity was 97% (35/36 supraventricular tachycardia). Single-chamber analysis demonstrated 99% sensitivity and 97% specificity. CONCLUSION: The VTC algorithm demonstrated high sensitivity and specificity in discriminating between ventricular and supraventricular arrhythmias.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantables , Frecuencia Cardíaca , Anciano , Algoritmos , Animales , Arritmias Cardíacas/clasificación , Arritmias Cardíacas/fisiopatología , Diagnóstico Diferencial , Electrofisiología , Humanos , Ratones , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA