Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
2.
Int J Cardiol ; 417: 132526, 2024 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-39244096

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in adults, yet its underlying pathophysiology remains poorly understood. This study assessed whether circulating biomarker concentrations differ in paroxysmal AF patients during an acute episode compared to sinus rhythm. METHODS: The Time of Calamity study is a prospective biomarker study within the RACE V study. Patients underwent venous blood sampling in sinus rhythm at inclusion in RACE V, as well as during a subsequent acute episode of AF for which patients reported to the hospital. Ten biomarkers were analyzed. RESULTS: Thirty-nine patients (mean age 60 ± 9 years, 10 (25 %) women) were enrolled. During an acute AF episode, dickkopf-related protein 3 and insulin-like growth factor binding protein 7 were significantly lower, while N-terminal pro B-type natriuretic peptide (NT-proBNP), high-sensitive troponin T (hsTnT), growth differentiation factor 15, and interleukin 6 were significantly higher (all p < 0.05). CONCLUSIONS: Biomarker concentrations in paroxysmal AF patients are dynamic and differ between sinus rhythm and acute AF episodes. Notably, NT-proBNP and hsTnT, commonly used in clinical practice, were significantly elevated during an acute AF episode.


Asunto(s)
Fibrilación Atrial , Biomarcadores , Humanos , Fibrilación Atrial/sangre , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Biomarcadores/sangre , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Enfermedad Aguda , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Frecuencia Cardíaca/fisiología , Troponina T/sangre
3.
Int J Cardiol ; 417: 132522, 2024 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-39245073

RESUMEN

BACKGROUND: The role of catheter ablation in elderly patients with atrial fibrillation (AF) is unclear. Pulsed field ablation (PFA) demonstrates a favorable clinical profile, however, data on elderly patients are lacking. AIMS: We aimed to assess the safety and efficacy of PFA in the elderly, using data from the EU-PORIA registry. METHODS: Periprocedural complications and long-term safety and efficacy outcomes of AF ablation using the pentaspline PFA catheter (Farapulse™) were compared between patients older than 80 years old and their younger counterparts, across seven European centers. RESULTS: Among the 1233 patients in the registry, 88 (7.1 %) were older than 80 years. Elderly patients were more often females (51.1 % vs 37.8 %, p = 0.01) with a lower median BMI (26.0, IQR:23.5-29.2 vs 26.9, IQR:24.4-30.4 kg/m2, p = 0.02), a higher median CHA2DS2-VASc score (4, IQR:3-5 vs 2, IQR:1-3, p < 0.001) and a higher incidence of hypertension (73.9 % vs 52.7 %, p < 0.001). In both groups, most patients had paroxysmal AF (58.0 % vs 60.3 %, p = 0.65). Ablation in the elderly was more frequently performed with minimally interrupted anticoagulation (87.5 % vs 59.7 %, p < 0.001). Despite comparable rates of overall complications (5.7 % vs 3.5 %, p = 0.29), elderly patients had a higher incidence of stroke (2.3 % vs 0.3 %, p = 0.04). At 12 months, major adverse clinical events (4.5 % vs. 2.1 %, p = 0.12) and arrhythmia-free survival (70 % vs 74 %, p = 0.69) were comparable in both groups. None of the recurrence-free elderly patients were on antiarrhythmic drugs at the end of follow-up. CONCLUSION: In this real-world cohort, the efficacy of PFA for AF was similar in elderly and younger patients. Despite comparable complication rates, a higher incidence of stroke was observed in the elderly.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Resultado del Tratamiento , Europa (Continente)/epidemiología , Estudios de Seguimiento , Persona de Mediana Edad
4.
Neth Heart J ; 32(9): 326-331, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39105898

RESUMEN

INTRODUCTION: Concerns exist of women underrepresentation in atrial fibrillation (AF) studies, potentially limiting the generalisability of study findings to women with AF. We assessed the participation of women in AF clinical studies performed at a tertiary care centre in the Northern Netherlands. METHODS: Eight AF clinical studies with screening logs were available for analysis. To identify sex-specific differences, patient inclusion and exclusion and reasons for exclusion were assessed. Participation-to-prevalence ratios (PPRs) were calculated to evaluate the representation of women in the studies relative to the AF sex distribution of the general population in the Netherlands (2019 Global Burden of Disease study). RESULTS: We included 1739 screened patients with AF in the analysis, of whom 722 (41.5%) were women. Of the patients screened, 161 (9%) were enrolled. Median age of screened patients was 69 years (interquartile range (IQR): 61-77), and women were older than men (71 years; IQR: 63-79 vs 68 years; IQR: 60-75; p < 0.001). Women were not underscreened compared with men (PPR: 1.09; 95% confidence interval (CI): 1.08-1.10), disproportionally excluded (92% vs 90%; p = 0.10) or less willing to participate (17% vs 15%; p = 0.36). Women had an overall PPR of 1.05 (95% CI: 1.05-1.06) compared with the general AF population. CONCLUSION: At our tertiary hospital in the Northern Netherlands, women appeared to be well-represented in AF studies. The current study advocates for the adoption of a more comprehensive measure of equity, such as the PPR, and screening log evaluation to improve the generalisability of study findings to the entire clinical AF population.

5.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38875490

RESUMEN

AIMS: Superior vena cava (SVC) isolation during atrial fibrillation catheter ablation is limited by the risk of collateral damage to the sinus node and/or the phrenic nerve. Due to its tissue-specificity, we hypothesized the feasibility and safety of pulsed-field ablation (PFA)-based SVC isolation. METHODS AND RESULTS: One hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (±posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phrenic nerve palsy at the end of the procedure and at hospital discharge. Transient high-degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred. CONCLUSION: SVC isolation using a pentaspline PFA catheter is feasible and safe.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Estudios de Factibilidad , Vena Cava Superior , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Vena Cava Superior/cirugía , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Estudios Prospectivos , Venas Pulmonares/cirugía , Catéteres Cardíacos , Diseño de Equipo , Nervio Frénico/lesiones
6.
Artículo en Inglés | MEDLINE | ID: mdl-38864809

RESUMEN

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively. RESULTS: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P = >0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSIONS: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38869506

RESUMEN

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: To assess the outcomes of pulsed-field ablation (PFA) in HF. METHODS: MANIFEST-PF is a multicenter patient-level registry of consecutive patients undergoing PFA for paroxysmal (PAF) or persistent AF (PerAF). In this sub-study, patients were stratified as: no history of HF (no-HF), HF with preserved EF (HFPEF; LVEF≥50%) or HF with reduced/mildly-reduced EF (HFMR/REF; LVEF<50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30s and major adverse events (MAEs), respectively. RESULTS: Of the 1,381 patients, 85% (n=1,174) were no-HF, 6.2% (n=87) were HFPEF, and 8.6% (n=120) were HFMR/REF. No-HF patients had less PerAF than patients with HF (p<0.001), with no difference between HF subtypes (p=1.00). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF than with HFPEF or HFMR/REF (79.9%, 71.3%, 67.5%, p<0.001), but similar between HFMR/REF and HFPEF (p=0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFPEF vs HFMR/REF for those with PAF (82.8%/82.4%/71.7%, p=0.09) and PerAF (73.3%, 64.2%, and 64.9%, p=0.14.MAE rates were similar between the no-HF, HFPEF and HFMR/REF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSION: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

8.
J Cardiovasc Dev Dis ; 11(4)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38667734

RESUMEN

Background: In patients with an implantable cardioverter-defibrillator (ICD) for secondary prevention, sex differences may exist in clinical outcomes. We sought to investigate sex differences in appropriate ICD therapy, appropriate and inappropriate shock, and all-cause mortality in this patient population. Methods: A total of 257 patients who received an ICD for a secondary prevention indication in the University Medical Centre Groningen (UMCG) between 1 January 2012 and 31 December 2018 were retrospectively included in a consecutive manner. Appropriate ICD therapy, comprising shock and antitachycardia pacing (ATP) for ventricular fibrillation (VF) or ventricular tachycardia (VT), was the primary outcome. Results: The patient population included 257 patients, of whom 45 (18%) were women and 212 (82%) were men. The median of the age was 64 (interquartile range (IQR) 53-72) years. During follow-up (median duration 6.2 (IQR 4.8-7.8) years), first appropriate device therapy took place in 10 (22%) patients for women and 85 (40%) patients for men. Female sex was negatively associated with the rate of appropriate ICD therapy, univariably (hazard ratio (HR) 0.48 [95% confidence interval (CI) 0.25-0.93]; p = 0.030) and multivariably (HR 0.44 [95% CI 0.20-0.95]; p = 0.036). Conclusions: Women with secondary prevention ICDs were less likely than men to receive appropriate ICD therapy.

9.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38430087

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Masculino , Femenino , Anciano , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Estudios Retrospectivos , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento , Sistema de Registros
10.
Heart Rhythm ; 21(10): 1779-1786, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38493994

RESUMEN

BACKGROUND: Current cohorts of patients with idiopathic ventricular fibrillation (IVF) primarily include adult-onset patients. Underlying causes of sudden cardiac arrest vary with age; therefore, underlying causes and disease course may differ for adolescent-onset vs adult-onset patients. OBJECTIVE: The purpose of this study was to compare adolescent-onset with adult-onset patients having an initially unexplained cause of VF. METHODS: The study included 39 patients with an index event aged ≤19 years (adolescent-onset) and 417 adult-onset patients from the Dutch Idiopathic VF Registry. Data on event circumstances, clinical characteristics, change in diagnosis, and arrhythmia recurrences were collected and compared between the 2 groups. RESULTS: In total, 42 patients received an underlying diagnosis during follow-up (median 7 [2-12] years), with similar yields (15% adolescent-onset vs 9% adult-onset; P = .16). Among the remaining unexplained patients, adolescent-onset patients (n = 33) had their index event at a median age of 17 [16-18] years, and 72% were male. The youngest patient was aged 13 years. In comparison with adults (n = 381), adolescent-onset patients more often had their index event during exercise (P <.01). Adolescent-onset patients experienced more appropriate implantable cardioverter-defibrillator (ICD) therapy during follow-up compared with adults (44% vs 26%; P = .03). Inappropriate ICD therapy (26% vs 17%; P = .19), ICD complications (19% vs 14%; P = .41), and deaths (3% vs 4%; P = 1) did not significantly differ between adolescent-onset and adult-onset patients. CONCLUSION: IVF may occur during adolescence. Adolescent-onset patients more often present during exercise compared with adults. Furthermore, they are more vulnerable to ventricular arrhythmias as reflected by a higher incidence of appropriate ICD therapy.


Asunto(s)
Edad de Inicio , Sistema de Registros , Fibrilación Ventricular , Humanos , Masculino , Femenino , Adolescente , Países Bajos/epidemiología , Fibrilación Ventricular/terapia , Fibrilación Ventricular/etiología , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/diagnóstico , Adulto , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Estudios de Seguimiento , Adulto Joven , Incidencia , Persona de Mediana Edad , Paro Cardíaco/terapia , Paro Cardíaco/etiología , Paro Cardíaco/epidemiología , Electrocardiografía
11.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38340118

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Sistema de Registros , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Anciano , Europa (Continente) , Resultado del Tratamiento , Recurrencia , Reoperación/estadística & datos numéricos
12.
Open Heart ; 10(2)2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38135341

RESUMEN

BACKGROUND: Sex differences in atrial fibrillation (AF) are observed in terms of comorbidities, symptoms, therapies received, AF progression and cardiovascular complications. METHODS: We assessed the differences in prevalence and the determinants of AF progression, as well as the clinical characteristics and quality of life (QoL), between women and men with paroxysmal AF included in the RACE V (Reappraisal of Atrial Fibrillation: Interaction between hyperCoagulability, Electrical remodeling, and Vascular Destabilisation in the Progression of AF) study. At baseline, extensive phenotyping was done. To assess AF progression, implantable loop recorder (ILR) monitoring was used throughout follow-up. AF progression was defined as (1) progression to persistent or permanent AF or (2) progression of paroxysmal AF (>3% burden increase). RESULTS: 417 patients were included, 179 (43%) of whom were women. Women were older (median 67 years vs 63 years, p<0.001), less often had coronary artery disease (n=11 (6%) vs n=36 (16%), p=0.003), had more obesity (n=57 (32%) vs n=50 (21%), p=0.013), had less epicardial and pericardial fat (median 144 (interquartile range [IQR] 94-191) mL vs 199 (IQR 146-248) mL, p<0.001; and median 89 (ICQ 61-121) mL vs 105 (IQR 83-133) mL, p<0.001, respectively) and had more impaired left atrial function. The median follow-up was 2.2 (1.6-2.8) years. 51 of 417 patients (5.5% per year) showed AF progression (15/179 (8.4%) women and 36/238 (15.1%) men, p=0.032). Multivariable analysis showed tissue factor pathway inhibitor, N-terminal prohormone brain natriuretic peptide (NT-proBNP) and PR interval being associated with AF progression in women and factor XIIa:C1 esterase, NT-proBNP and proprotein convertase subtilisin/kexin type 9 in men. QoL was not different between sexes. CONCLUSION: Despite older age, the incidence of AF progression was lower in women. Parameters associated with AF progression varied in part between sexes, suggesting different underlying pathophysiological mechanisms.


Asunto(s)
Fibrilación Atrial , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Calidad de Vida
13.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37910101

RESUMEN

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Asunto(s)
Fibrilación Atrial , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adolescente , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Estudios de Cohortes , Factores Sexuales , Resultado del Tratamiento
14.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37967257

RESUMEN

AIMS: During the diagnostic work-up of patients with idiopathic ventricular fibrillation (VF), next-generation sequencing panels can be considered to identify genotypes associated with arrhythmias. However, consensus for gene panel testing is still lacking, and variants of uncertain significance (VUS) are often identified. The aim of this study was to evaluate genetic testing and its results in idiopathic VF patients. METHODS AND RESULTS: We investigated 419 patients with available medical records from the Dutch Idiopathic VF Registry. Genetic testing was performed in 379 (91%) patients [median age at event 39 years (27-51), 60% male]. Single-gene testing was performed in 87 patients (23%) and was initiated more often in patients with idiopathic VF before 2010. Panel testing was performed in 292 patients (77%). The majority of causal (likely) pathogenic variants (LP/P, n = 56, 15%) entailed the DPP6 risk haplotype (n = 39, 70%). Moreover, 10 LP/P variants were found in cardiomyopathy genes (FLNC, MYL2, MYH7, PLN (two), TTN (four), RBM20), and 7 LP/P variants were identified in genes associated with cardiac arrhythmias (KCNQ1, SCN5A (2), RYR2 (four)). For eight patients (2%), identification of an LP/P variant resulted in a change of diagnosis. In 113 patients (30%), a VUS was identified. Broad panel testing resulted in a higher incidence of VUS in comparison to single-gene testing (38% vs. 3%, P < 0.001). CONCLUSION: Almost all patients from the registry underwent, albeit not broad, genetic testing. The genetic yield of causal LP/P variants in idiopathic VF patients is 5%, increasing to 15% when including DPP6. In specific cases, the LP/P variant is the underlying diagnosis. A gene panel specifically for idiopathic VF patients is proposed.


Asunto(s)
Arritmias Cardíacas , Fibrilación Ventricular , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/genética , Fibrilación Ventricular/epidemiología , Arritmias Cardíacas/genética , Pruebas Genéticas
16.
J Clin Med ; 12(18)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37762709

RESUMEN

Aims: to study the technical performance of epicardial left ventricular (LV) leads placed via video assisted thoracic surgery (VATS), compared to transvenously placed leads for cardiac resynchronization therapy (CRT). Methods: From 2001 until 2013, a total of 644 lead placement procedures were performed for CRT. In the case of unsuccessful transvenous LV lead placement, the patient received an epicardial LV lead. Study groups consist of 578 patients with a transvenous LV lead and 66 with an epicardial LV lead. The primary endpoint was LV-lead failure necessitating a replacement or deactivation. The secondary endpoint was energy consumption. Results: The mean follow up was 5.9 years (epicardial: 5.5 ± 3.1, transvenous: 5.9 ± 3.5). Transvenous leads failed significantly more frequently than epicardial leads with a total of 66 (11%) in the transvenous leads group vs. 2 (3%) in the epicardial lead group (p = 0.037). Lead energy consumption was not significantly different between groups. Conclusions: Epicardial lead placement is feasible, safe and shows excellent long-term performance compared to transvenous leads. Epicardial lead placement should be considered when primary transvenous lead placement fails or as a primary lead placement strategy in challenging cases.

18.
J Clin Med ; 12(13)2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37445514

RESUMEN

In this study, we sought to investigate the occurrence of appropriate implantable cardioverter-defibrillator (ICD) therapies and inappropriate shocks in secondary prevention ICD recipients with ventricular arrhythmia of unclear cause and ventricular arrhythmia in the context of underlying heart disease. In this retrospective study, consecutive patients with an ICD implanted for secondary prevention in the University Medical Center Groningen (UMCG), the Netherlands between 1 January 2012 and 31 December 2018 were included. Patients were classified as having ventricular arrhythmia of unclear cause if no clear cause was found which could explain the index ventricular arrhythmia. The primary outcome was appropriate ICD therapy. The study population consisted of 257 patients. In 220 patients, an underlying heart disease could be identified as the cause of ventricular arrhythmia, while 37 patients had an unclear cause of ventricular arrhythmia. The median age was 64 years (interquartile range (IQR) 53-72 years). Forty-five (18%) patients were women. During a median duration of follow-up of 6.2 years (IQR 4.8-7.8 years), appropriate ICD therapy occurred in 95 (37%) patients. This number was 90 (41%) in the group with a clear etiology and 5 (14%) in the group with an unclear etiology. In multivariable analysis, index ventricular arrhythmia of unclear cause was associated with fewer appropriate ICD therapies (HR 0.37 [95% CI 0.14-0.99]; p = 0.048), as well as an increased risk of inappropriate ICD shocks (HR 3.71 [95% CI 1.17-11.80]; p = 0.026). Index ventricular arrhythmia of unclear cause was significantly associated with fewer appropriate ICD therapies.

20.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37379528

RESUMEN

AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Poria , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía , Venas Pulmonares/cirugía , Recurrencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA