RESUMEN
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis, but data are limited on younger, low-risk patients. This analysis compares outcomes in low-surgical-risk patients aged <75 years receiving TAVR versus surgery. METHODS: The Evolut Low Risk Trial randomized 1414 low-risk patients to treatment with a supra-annular, self-expanding TAVR or surgery. We compared rates of all-cause mortality or disabling stroke, associated clinical outcomes, and bioprosthetic valve performance at 3 years between TAVR and surgery patients aged <75 years. RESULTS: In patients <75 years, 352 were randomized to TAVR and 351 to surgery. Mean age was 69.1±4.0 years (minimum 51 and maximum 74); Society of Thoracic Surgeons Predicted Risk of Mortality was 1.7±0.6%. At 3 years, all-cause mortality or disabling stroke for TAVR was 5.7% and 8.0% for surgery (P=0.241). Although there was no difference between TAVR and surgery in all-cause mortality, the incidence of disabling stroke was lower with TAVR (0.6%) than surgery (2.9%; P=0.019), while surgery was associated with a lower incidence of pacemaker implantation (7.1%) compared with TAVR (21.0%; P<0.001). Valve reintervention rates (TAVR 1.5%, surgery 1.5%, P=0.962) were low in both groups. Valve performance was significantly better with TAVR than surgery with lower mean aortic gradients (P<0.001) and lower rates of severe prosthesis-patient mismatch (P<0.001). Rates of valve thrombosis and endocarditis were similar between groups. There were no significant differences in rates of residual ≥moderate paravalvular regurgitation. CONCLUSIONS: Low-risk patients <75 years treated with supra-annular, self-expanding TAVR had comparable 3-year all-cause mortality and lower disabling stroke compared with patients treated with surgery. There was significantly better valve performance in patients treated with TAVR. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT02701283.
RESUMEN
BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Factores de Riesgo , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Medición de Riesgo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Estados Unidos/epidemiología , Índice de Severidad de la Enfermedad , Complicaciones Posoperatorias/mortalidad , Recuperación de la Función , Anciano de 80 o más Años , Persona de Mediana Edad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidadRESUMEN
BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arteria Femoral , Estado de Salud , Prótesis Valvulares Cardíacas , Calidad de Vida , Recuperación de la Función , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Periférico/efectos adversos , Punciones , Diseño de PrótesisRESUMEN
Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.
RESUMEN
BACKGROUND: This study investigated the safety and effectiveness of surgical aortic valve replacement with RESILIA tissue (Edwards Lifesciences) through 5 years in patients with native bicuspid aortic valves. Outcomes were compared with those for patients with tricuspid aortic valves. METHODS: Of 689 patients from the COMMENCE (ProspeCtive, nOn-randoMized, MulticENter) trial who received the study valve, 645 had documented native valve morphology and core laboratory-evaluable echocardiograms from any postoperative visit, which were used to model hemodynamic outcomes over 5 years. Linear mixed-effects models were used to estimate longitudinal changes in mean gradient and effective orifice area. RESULTS: Patients with native bicuspid aortic valves (n = 214) were more than a decade younger than those with tricuspid aortic valves (n = 458; 59.8 ± 12.4 years vs 70.2 ± 9.5 years; P < .001). The bicuspid aortic valve cohort exhibited no structural valve deterioration over 5 years, and rates of paravalvular leak and transvalvular regurgitation were low (0.7% and 2.9%, respectively [all mild] at 5 years). These outcomes mirrored those in patients with native tricuspid aortic valves. The model-estimated postoperative mean gradient and effective orifice area, as well as the rate of change of these outcomes, adjusted for age, body surface area, and bioprosthesis size, did not differ between the 2 cohorts. CONCLUSIONS: Among patients with bicuspid aortic valves, RESILIA tissue valves demonstrated excellent outcomes to 5 years, including no structural valve deterioration and very low rates of paravalvular and transvalvular regurgitation. These results are encouraging for RESILIA tissue durability in young patients.
Asunto(s)
Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Bioprótesis , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Humanos , Masculino , Femenino , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Anciano , Estudios Prospectivos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Tiempo , Estudios de SeguimientoRESUMEN
BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis , Factores de RiesgoRESUMEN
Objective: Novel tissue leaflets (RESILIA tissue) may improve durability of bioprosthetic heart valves. The COMMENCE trial is an ongoing prospective study to evaluate valve replacement using RESILIA tissue. This report describes mid-term outcomes in the mitral cohort of COMMENCE. Methods: Adult patients requiring mitral valve replacement were enrolled in a prospective, single-arm trial at 17 sites in the United States and Canada. An independent clinical events committee adjudicated safety events using definitions from established guidelines, and hemodynamic performance was evaluated by an independent echocardiographic core laboratory. Results: Eighty-two patients (median age 70 years) successfully underwent mitral valve replacement with the study valve. Five-year event-free probabilities for all-cause mortality, structural valve deterioration, and reoperation were 79.9%, 98.7%, and 97.1%, respectively. Hemodynamic valve function measurements were stable through the 5-year follow-up period; valvular leaks were infrequently observed and primarily clinically insignificant/mild. Conclusions: Mitral valve replacement patients implanted with a RESILIA tissue bioprosthesis had a good safety profile and clinically stable hemodynamic performance.
RESUMEN
BACKGROUND: High surgical risk may preclude mitral valve replacement in many patients. Transcatheter mitral valve replacement (TMVR) using transfemoral transseptal access is a novel technology for the treatment of mitral regurgitation (MR) in high-risk surgical patients. OBJECTIVES: This analysis evaluates 30-day and 1-year outcomes of the Intrepid TMVR Early Feasibility Study in patients with ≥moderate-severe MR. METHODS: The Intrepid TMVR Early Feasibility Study is a multicenter, prospective, single-arm study. Clinical events were adjudicated by a clinical events committee; endpoints were defined according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 33 patients, enrolled at 9 U.S. sites between February 2020 and August 2022, were included. The median age was 80 years, 63.6% of patients were men, and mean Society of Thoracic Surgeons Predicted Risk of Mortality for mitral valve replacement was 5.3%. Thirty-one (93.9%) patients were successfully implanted. Median postprocedural hospitalization length of stay was 5 days, and 87.9% of patients were discharged to home. At 30 days, there were no deaths or strokes, 8 (24.2%) patients had major vascular complications and none required surgical intervention, there were 4 cases of venous thromboembolism all successfully treated without sequelae, and 1 patient had mitral valve reintervention for severe left ventricular outflow tract obstruction. At 1 year, the Kaplan-Meier all-cause mortality rate was 6.7%, echocardiography showed ≤mild valvular MR, there was no/trace paravalvular leak in all patients, median mitral valve mean gradient was 4.6 mm Hg (Q1-Q3: 3.9-5.3 mm Hg), and 91.7% of survivors were in NYHA functional class I/II with a median 11.4-point improvement in Kansas City Cardiomyopathy Questionnaire overall summary scores. CONCLUSIONS: The early benefits of the Intrepid transfemoral transseptal TMVR system were maintained up to 1 year with low mortality, low reintervention, and near complete elimination of MR, demonstrating a favorable safety profile and durable valve function.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios de Factibilidad , Estudios Prospectivos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiologíaRESUMEN
Objective: A kaolin-based nonresorbable hemostatic gauze, QuikClot Control+, has demonstrated effective hemostasis and safety when used for severe/life-threatening (grade 3/4) internal organ space bleeding. We evaluated the efficacy and safety of this gauze for mild to moderate (grade 1-2) bleeding in cardiac surgery compared with control gauze. Methods: This was a randomized, controlled, single-blinded study of patients who underwent cardiac surgery between June 2020 and September 2021 across 7 sites with 231 subjects randomized 2:1 to QuikClot Control+ or control. The primary efficacy end point was hemostasis rate (ie, subjects achieving grade 0 bleed) through up to 10 minutes of bleeding site application, assessed using a semiquantitative validated bleeding severity scale tool. The secondary efficacy end point was the proportion of subjects achieving hemostasis at 5 and 10 minutes. Adverse events, assessed up to 30 days postsurgery, were compared between arms. Results: The predominant procedure was coronary artery bypass grafting, and 69.7% and 29.4% were sternal edge and surgical site (suture line)/other bleeds, respectively. Of the QuikClot Control+ subjects, 121 of 153 (79.1%) achieved hemostasis within 5 minutes, compared with 45 of 78 (58.4%) controls (P < .001). At 10 minutes, 137 of 153 patients (89.8%) achieved hemostasis compared with 52 of 78 controls (68.4%) (P < .001). At 5 and 10 minutes, hemostasis was achieved in 20.7% and 21.4% more QuikClot Control+ subjects, respectively, compared with controls (P < .001). There were no significant differences in safety or adverse events between treatment arms. Conclusions: QuikClot Control+ demonstrated superior performance in achieving hemostasis for mild to moderate cardiac surgery bleeding compared with control gauze. The proportion of subjects achieving hemostasis was more than 20% higher in QuikClot Control+ subjects at both timepoints compared with controls, with no significant difference in safety outcomes.
RESUMEN
OBJECTIVE: To evaluate whether transcatheter or surgical aortic valve replacement (TAVR or SAVR) affects clinical and haemodynamic outcomes in symptomatic patients with moderately-severe aortic stenosis (AS). METHODS: Echocardiographic evidence of severe AS for enrolment in the Evolut Low Risk trial was based on site-reported measurements. For this post hoc analysis, core laboratory measurements identified patients with symptomatic moderately-severe AS (1.0Asunto(s)
Estenosis de la Válvula Aórtica
, Implantación de Prótesis de Válvulas Cardíacas
, Humanos
, Válvula Aórtica/diagnóstico por imagen
, Válvula Aórtica/cirugía
, Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
, Calidad de Vida
, Estenosis de la Válvula Aórtica/diagnóstico por imagen
, Estenosis de la Válvula Aórtica/cirugía
, Estenosis de la Válvula Aórtica/etiología
, Resultado del Tratamiento
RESUMEN
BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Masculino , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugíaRESUMEN
Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Aórtica/cirugía , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversosRESUMEN
BACKGROUND: The COMMENCE trial was conducted to evaluate the safety and effectiveness of aortic valve replacement using a bioprosthesis with novel RESILIA tissue (Edwards Lifesciences). RESILIA tissue is incorporated in the INSPIRIS RESILIA aortic valve (Edwards Lifesciences). METHODS: Patients underwent clinically indicated surgical aortic valve replacement with a bovine pericardial bioprosthesis (model 11000A; Edwards Lifesciences) in a prospective, multinational, multicenter (n = 27), US Food and Drug Administration Investigational Device Exemption trial. Events were adjudicated by an independent clinical events committee, and echocardiograms were analyzed by an independent core laboratory. Outcomes through an observational period of 5 years are reported. RESULTS: Between January 2013 and March 2016, 689 patients received the study valve. Mean patient age was 66.9 ± 11.6 years; Society of Thoracic Surgeons Predicted Risk of Mortality was 2.0% ± 1.8%; and 23.8%, 49.9%, and 24.4% of patients were New York Heart Association functional class I, II, and III at baseline, respectively. Through December 11, 2020 the follow-up duration was 4.3 ± 1.4 years, and the completeness of follow-up over the observational period was 95.5%. Early (<30 days) all-cause mortality was 1.2%, stroke 1.6%, and major paravalvular leak 0.1%. Five-year actuarial freedom from all-cause mortality, structural valve deterioration, and all-cause reintervention were 89.2%, 100%, and 98.7%, respectively. At 5 years the effective orifice area was 1.6 ± 0.5 cm2, mean gradient was 11.5 ± 6.0 mm Hg, 97.8% of patients were class I/II, and 97.8% and 96.3% of patients had none/trace paravalvular and transvalvular regurgitation, respectively. CONCLUSIONS: The safety and hemodynamic performance of this aortic bioprosthesis with RESILIA tissue through 5 years are encouraging, with clinically stable hemodynamics, minimal regurgitation, and no evidence of structural valve deterioration.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Animales , Bovinos , Persona de Mediana Edad , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Prospectivos , Resultado del TratamientoRESUMEN
We evaluated predictors of permanent pacemaker implantation (PPI) following self-expanding transcatheter aortic valve replacement (TAVR), examined site-to-site variability of PPI rates, and explored the relationship of implantation methods on the need for PPI. Despite the benefits of TAVR compared to surgical aortic valve replacement, increased PPI remains a limitation. A total of 699 patients without baseline PPI were included in the study. Clinical, echocardiographic, and procedural characteristics were compared in patient with and without new PPI. Clinical outcomes were assessed at 30 days and 1 year. Funnel plots were constructed to display site-to- site variability and identify outliers in PPI. Clinical outcomes were similar in patients with and without PPI. Predictors of a new PPI within 7 days included a baseline right bundle branch block (p < 0.001) and not using general anesthesia (p = 0.003). There was substantial site to site variability in the rate of PPI. Patients at sites with a lower PPI rate had shallower implantation depth at the non-coronary (p < 0.001) and the left coronary sinus (p < 0.001), and fewer patients with an implantation depth > 5 mm below the annulus (p = 0.004). In low-risk patients undergoing TAVR with Evolut valves, baseline conduction disorders and implant depth were important predictors of PPI. Implantation method may have contributed to this variability in PPI rates across clinical sites.
Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Marcapaso Artificial/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
Objective: To compare 1-year outcomes in patients at low surgical risk with bicuspid aortic valve stenosis (AS) following transcatheter aortic valve replacement (TAVR) and low-risk patients with tricuspid AS following surgical aortic valve replacement (SAVR). Background: The pivotal randomized, prospective, multicenter TAVR trials compared TAVR vs SAVR in patients with tricuspid AS. No such trials exist for bicuspid AS. Methods: The Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled 150 patients from 25 sites in the United States. A screening committee confirmed bicuspid anatomy and valve classification based on computed tomography using the Sievers classification. Annular measurements guided valve sizing. These patients were propensity-matched to the SAVR patients in the randomized Evolut Low Risk Trial using 1:1 5-to-1-digit Greedy method, resulting in 144 matched pairs. For both trials, an independent clinical events committee adjudicated all serious adverse events, and the same independent core laboratory assessed all echocardiograms. Results: The 1-year composite of death, disabling stroke, or aortic valve-related rehospitalization for bicuspid TAVR vs tricuspid SAVR was 6 (4.2%) vs 6 (4.2%) (P = .99). The effective orifice area (2.2 ± 0.7 cm2 vs 2.0 ± 0.6 cm2) was larger and the valve gradient was lower (8.7 ± 3.9 mm Hg vs 11.2 ± 4.7 mm Hg) in the TAVR group at 1 year (both P < .001). Moderate/severe aortic regurgitation was present in 1 TAVR and 2 SAVR patients (0.8% vs 1.6%; P > .99). Conclusions: In this select group of low-risk bicuspid patients, in the short-term follow-up, TAVR appears to have similar outcomes to those seen in comparable low-risk tricuspid patients undergoing SAVR.
RESUMEN
OBJECTIVE: Patients with elevated CHA2DS2-VASc scores are at high risk for atrial fibrillation (AF) and thromboembolic events (TE) after cardiac surgery. Left atrial appendage exclusion (LAAE) is a permanent, continuous approach to stroke prevention in AF, overcoming limitations of oral anticoagulation (OAC). We report ATLAS trial results focused on LAAE technical success and perioperative safety and TE rates with and without LAAE in cardiac surgery patients who developed postoperative AF (POAF). METHODS: ATLAS (NCT02701062) was a prospective, multicenter, feasibility trial. Patients age ≥18 years, undergoing structural heart procedure, with no preoperative AF, CHA2DS2-VASc ≥2, and HAS-BLED ≥2 were randomized 2:1 to LAAE or no LAAE. Patients who developed POAF and/or received LAAE were followed for 1 year. LAAE was evaluated with intraoperative transesophageal echocardiography. RESULTS: A total of 562 patients were randomized to LAAE (n = 376) or no LAAE (n = 186). Mean CHA2DS2-VASc (3.4 vs 3.4) and HAS-BLED (2.8 vs 2.9) scores were similar for LAAE and no LAAE groups. LAAE success (no flow nor residual stump >10 mm) was 99%. One LAAE-related serious adverse event (0.27%) occurred and was resolved without sequelae. There were 44.3% of patients who developed POAF. Through 1 year, 3.4% of LAAE patients and 5.6% of no LAAE patients had TE. OAC was used by 32.5% of POAF patients. Bleeding was higher with OAC than without (16.1% vs 5.4%, P = 0.008). CONCLUSIONS: ATLAS demonstrated a high rate of successful LAAE with low LAAE-related serious adverse events in cardiac surgery patients. Study results should be considered in future trial design to further evaluate prophylactic LAAE for stroke prevention in cardiac surgery patients with elevated stroke risk.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Accidente Cerebrovascular , Humanos , Adolescente , Factores de Riesgo , Medición de Riesgo/métodos , Apéndice Atrial/cirugía , Estudios Prospectivos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/complicaciones , Fibrilación Atrial/cirugíaRESUMEN
BACKGROUND: Severe symptomatic degenerative mitral regurgitation (DMR) has a poor prognosis in the absence of treatment, and new transcatheter options are emerging. OBJECTIVES: The CLASP IID (Edwards PASCAL Transcatheter Valve Repair System Pivotal Clinical Trial) randomized trial (NCT03706833) is the first to evaluate the safety and effectiveness of the PASCAL system compared with the MitraClip system in patients with significant symptomatic DMR. This report presents the primary safety and effectiveness endpoints for the trial. METHODS: Patients with 3+ or 4+ DMR at prohibitive surgical risk were assessed by a central screening committee and randomized 2:1 (PASCAL:MitraClip). Study oversight also included an echocardiography core laboratory and a clinical events committee. The primary safety endpoint was the composite major adverse event rate at 30 days. The primary effectiveness endpoint was the proportion of patients with mitral regurgitation (MR) ≤2+ at 6 months. RESULTS: A prespecified interim analysis in 180 patients demonstrated noninferiority of the PASCAL system vs the MitraClip system for the primary safety and effectiveness endpoints of major adverse event rate (3.4% vs 4.8%) and MR ≤2+ (96.5% vs 96.8%), respectively. Functional and quality-of-life outcomes significantly improved in both groups (P < 0.05). The proportion of patients with MR ≤1+ was durable in the PASCAL group from discharge to 6 months (PASCAL, 87.2% and 83.7% [P = 0.317 vs discharge]; MitraClip, 88.5% and 71.2% [P = 0.003 vs discharge]). CONCLUSIONS: The CLASP IID trial demonstrated safety and effectiveness of the PASCAL system and met noninferiority endpoints, expanding transcatheter treatment options for prohibitive surgical risk patients with significant symptomatic DMR.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del TratamientoRESUMEN
Importance: In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective: To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants: SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention: Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures: The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results: A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm2 vs 1.8 [0.6] cm2; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance: Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.