Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Base de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Ther Drug Monit ; 44(5): 665-673, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35358115

RESUMEN

BACKGROUND: Model-informed personalized prophylaxis with factor VIII (FVIII) replacement therapy aimed at higher trough levels is becoming indispensable for patients with severe hemophilia A. This study aimed to identify the most suitable population pharmacokinetic (PK) models for personalized prophylaxis using various FVIII products and 2 clinical assays and to implement the most suitable one in open-access software. METHODS: Twelve published population PK models were systematically compared to predict the time above target (TaT) for a reference dosing occasion. External validation was performed using a 5-point PK data from 39 adult patients with hemophilia A with FVIII measured by chromogenic substrate (CSA) and 1-stage assays (OSAs) using NONMEM under 3 different conditions: a priori (with all FVIII samples blinded), a posteriori (with 1 trough sample), and general model fit (with all FVIII samples including the reference dosing occasion provided). RESULTS: On average, the baseline covariate models overpredicted TaT (a priori; bias -3.8 hours to 49.6 hours). When additionally including 1 previous trough FVIII sample before the reference dosing occasion (a posteriori), only 50% of the models improved in bias (-1.0 hours to 36.5 hours) and imprecision (22.4 hours and 60.7 hours). Using all the time points (general model fit), the models accurately predicted (individual TaT less than ±12 hours compared with the reference) 62%-90% and 33%-74% of the patients using CSA and OSA data, respectively. Across all scenarios, predictions using CSA data were more accurate than those using the OSA data. CONCLUSIONS: One model performed best across the population (bias: -3.8 hours a priori, -1.0 hours a posteriori , and 0.6 hours general model fit ) and acceptably predicted 44% (a priori) to 90% ( general model fit ) of the patients. To allow the community-based evaluation of patient-individual FVIII dosing, this model was implemented in the open-access model-informed precision dosing software "TDMx."


Asunto(s)
Factor VIII , Hemofilia A , Adulto , Humanos , Hemofilia A/tratamiento farmacológico , Factor VIII/farmacocinética , Factor VIII/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA