Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Int Heart J ; 62(5): 1012-1018, 2021 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-34544981

RESUMEN

High-degree atrioventricular block (HAVB) or complete heart block (CHB) is a common complication associated with transcatheter aortic valve replacement (TAVR). However, some patients with HAVB/CHB recover with time. The results of electrophysiological studies (EPSs) using permanent pacemaker implantation (PPI) in patients with suspicious HAVB/CHB are considered controversial.This study aimed to evaluate whether HAVB/CHB induction at the bedside using a temporary pacemaker can predict recurrence in patients who had recovered from HAVB/CHB after TAVR.We enrolled a total of 11 patients who had recovered from HAVB/CHB and evaluated their electrophysiology using right ventricular pacing and/or procainamide administration.HAVB/CHB induction was positive. Three patients tested positive for HAVB/CHB, whereas 8 tested negative. The ejection fraction and the interval between HAVB/CHB onset and EPS were found to be significant. HAVB/CHB positive patients underwent PPI. A patient with a balloon-expandable valve tested positive just before recovery of CHB, but tested negative 5 days later and was included in the negative group. The 4 patients who tested negative received a cardiovascular implantable electric device (CIED). We observed HAVB/CHB in 2 patients who had previously tested positive after 3 months. Among those who tested negative, those with CIED had no HAVB/CHB, and others showed neither HAVB/CHB on electrocardiogram nor experienced syncope or sudden death.Our EPS revealed that HAVB/CHB induction may predict HAVB/CHB recurrence after TAVR. Valve type and EPS timing may affect the results.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bloqueo Atrioventricular/inducido químicamente , Bloqueo Atrioventricular/terapia , Electrofisiología Cardíaca/estadística & datos numéricos , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Administración Intravenosa , Anciano , Anciano de 80 o más Años , Antiarrítmicos/administración & dosificación , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Electrofisiología Cardíaca/tendencias , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Pruebas en el Punto de Atención/tendencias , Valor Predictivo de las Pruebas , Procainamida/administración & dosificación , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
2.
Int J Cardiovasc Imaging ; 36(10): 1811-1819, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32524242

RESUMEN

We aimed to evaluate the additional debulking efficacy of low-speed rotational atherectomy (RA) after high-speed RA by using intravascular imaging. A total of 22 severe calcified coronary lesions in 19 patients (age, 74 ± 10 years; 74% male) were retrospectively analyzed. All of these lesions underwent RA under optical coherence tomography (OCT) or optical frequency domain imaging (OFDI) guidance. At first, we performed high-speed RA with 220,000 rpm until the reduction of rotational speed disappeared; then, low-speed RA with 120,000 rpm using the same burr size was performed. OCT or OFDI was performed after both high-speed and low-speed RAs, and the minimum lumen area were compared. The initial and final burr sizes of high-speed RA were 1.5 (1.5-1.75) and 1.75 (1.5-2.0) mm, respectively. The number of sessions, total duration time, and maximum decreased rotational speed during high-speed RA were 11 ± 5 times, 113 ± 47 s, and 4000 (3000-5000) rpm, respectively. During low-speed RA, the number of sessions, total duration time, and maximum reduction of rotational speed were 3 ± 1 times, 32 ± 11 s, and 1000 (0-2000) rpm, respectively. The minimum lumen area was similar between after high-speed and after low-speed RA [2.61 ± 1.03 mm2 (after high-speed RA) vs. 2.65 ± 1.00 mm2 (after low-speed RA); P = 0.91]. Additional low-speed RA immediately after sufficient debulking by high-speed RA was not associated with increased lumen enlargement. There was no clinical efficacy of low-speed RA after high-speed RA.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Calcificación Vascular/terapia , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Aterectomía Coronaria/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen
3.
SAGE Open Med Case Rep ; 8: 2050313X20921081, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32577280

RESUMEN

A 68-year-old man was scheduled to undergo percutaneous coronary intervention for in-stent total occlusion of the severely tortuous right coronary artery. Intravascular ultrasound revealed heavy in-stent calcification. Lesion atherectomy was required; however, severe proximal vessel tortuosity was detected. We introduced a 7-Fr guide-extension catheter beyond the severely tortuous part and performed rotational atherectomy with a 1.5 mm burr. However, the balloon could not expand; therefore, we changed to an orbital atherectomy system. Subsequently, the balloon successfully expanded, and intravascular ultrasound revealed an enlarged lumen. Severe proximal vessel tortuosity limits the use of atherectomy devices; however, a guide-extension catheter delivers the atherectomy device beyond the tortuosity. The delivery of the orbital atherectomy system inside the guide-extension catheter is easy due to its low profile; the debulking effect increases with the number of passes and rotational speed. This strategy is a useful option for treating severe calcified lesions with proximal vessel tortuosity.

4.
SAGE Open Med Case Rep ; 8: 2050313X20907825, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32110413

RESUMEN

A 63 year-old woman with claudication underwent endovascular therapy for diffuse stenosis of the right superficial femoral artery in our hospital. We performed paclitaxel-coated balloon angioplasty using the IN.PACT™ Admiral™ and achieved acceptable results. After 42 days, we performed follow-up optical frequency domain imaging for the right superficial femoral artery lesion treated with paclitaxel-coated balloon and observed several high-intensity regions with attenuation on the lumen surface. Sustained drug availability is a notable characteristic of paclitaxel-coated balloon. To the best of our knowledge, this is the first report on the visualization of sustained drug retention on the lumen surface using follow-up optical frequency domain imaging after paclitaxel-coated balloon angioplasty in a human patient with superficial femoral artery disease.

5.
J Vasc Interv Radiol ; 31(1): 141-149, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31542277

RESUMEN

PURPOSE: To determine the clinical impact and predictors of slow flow after endovascular treatment (EVT) using the Crosser catheter for debulking infrapopliteal lesions associated with critical limb ischemia. MATERIALS AND METHODS: This retrospective study included 65 patients with critical limb ischemia (70 limbs, 90 infrapopliteal lesions), who underwent EVT using the Crosser catheter between November 2011 and February 2017. The Crosser catheter was used when the balloon catheter could not be passed through the lesion or could not be dilated sufficiently. Slow flow was evaluated after atherectomy using Crosser and was defined as delayed antegrade flow to the foot (total number of cine frames >35). RESULTS: Following atherectomy, slow flow developed in 37 infrapopliteal lesions (41.1%). Despite secondary treatment, slow flow persisted in 29 of 37 lesions (78%). After atherectomy using the Crosser catheter, the balloon could be passed through the lesion in all cases. The wound healing rate at 1 year after EVT (overall, 67.8%) was significantly poorer in the presence of slow flow (rate with vs. without slow flow, 45.3% vs. 84.4%, respectively; P = .006), especially among patients with stage ≥3 baseline wound, ischemia, and foot infection. The active length of the Crosser catheter was a predictor of slow flow (odds ratio, 1.05; 95% confidence interval, 1.03-1.08; P < .001), with an optimal cutoff of 100 mm. CONCLUSIONS: Slow flow is associated with a poorer wound healing rate at 1 year, especially for patients with severe baseline ischemia. To reduce the risk of slow flow, the active length of the Crosser catheter should be kept at <100 mm.


Asunto(s)
Angioplastia de Balón , Aterectomía/instrumentación , Isquemia/terapia , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/fisiopatología , Dispositivos de Acceso Vascular , Calcificación Vascular/terapia , Anciano , Angioplastia de Balón/efectos adversos , Aterectomía/efectos adversos , Velocidad del Flujo Sanguíneo , Enfermedad Crítica , Bases de Datos Factuales , Diseño de Equipo , Femenino , Humanos , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Flujo Sanguíneo Regional , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/fisiopatología , Grado de Desobstrucción Vascular , Cicatrización de Heridas
6.
J Arrhythm ; 35(2): 300-302, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31007798

RESUMEN

A 23-year-old male with manifest Wolff-Parkinson-White syndrome presented with a first occurrence of ventricular fibrillation (VF). Initially, we anticipated the occurrence of atrial fibrillation, causing rapid antegrade conduction over the accessory pathway and, thus, resulting in hemodynamic deterioration. Electrophysiological study revealed that the atrioventricular accessory pathway was located at the mid-septum. After eliminating the pathway, a J-point elevation was revealed in the inferior and lateral leads. In addition, program ventricular stimulation induced VF, and the administration of isoproterenol suppressed VF. In our case, VF occurrence can be attributed to early repolarization syndrome and ventricular preexcitation-modified J-point elevation.

7.
Circ Rep ; 1(2): 94-101, 2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33693119

RESUMEN

Background: Little is known about the superiority of balloon angioplasty vs. stent implantation for femoropopliteal (FP) lesions according to subgroup. Methods and Results: This study involved 1,018 de novo (balloon angioplasty, n=462; stent implantation, n=556) and 114 in-stent restenosis (ISR) FP lesions (balloon angioplasty, n=69; stent implantation, n=45) treated with endovascular therapy. For de novo FP lesions, the 3-year primary patency rate was significantly better with stent implantation than with balloon angioplasty (61% vs. 69%, log-rank P=0.001), but it was similar for ISR FP lesions (40% vs. 43%, log-rank P=0.83). For de novo FP lesions, stent implantation was favorable in all subgroups except for female sex (hazard ratio [HR], 0.92; 95% CI: 0.65-1.31, P=0.66), critical limb ischemia (CLI; HR, 0.70; 95% CI: 0.46-1.06, P=0.10), calcified lesion (HR, 0.81; 95% CI: 0.46-1.39, P=0.44), and poor tibial run-off (HR, 0.86; 95% CI: 0.59-1.25, P=0.42) subgroups. No difference was found between the 2 treatment strategies for ISR FP lesions in the majority of subgroups. Stent implantation, however, was favorable in totally occluded ISR FP lesions (HR, 0.45; 95% CI: 0.21-1.01, P=0.05). Conclusions: The primary patency rate in de novo FP lesions for the 2 treatment strategies was similar in the female, calcified lesion, CLI, and poor tibial run-off subgroups. Stent implantation was superior to balloon angioplasty for totally occluded ISR FP lesions.

8.
SAGE Open Med Case Rep ; 6: 2050313X18799243, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30210799

RESUMEN

A 62-year-old man with effort angina underwent percutaneous coronary intervention in our hospital. The target lesion was severely calcified at the mid part of the right coronary artery. Pre-procedural intravascular imaging and optical frequency domain imaging showed a calcified nodule at the lesion. We performed rotational atherectomy with a 2.0 mm burr and observed an increase in the lumen area; however, a large amount of calcified nodule persisted. We decided to perform rotational atherectomy with a burr size of 2.25 mm; however, distal embolization of the calcified nodule occurred. We failed to retrieve the embolus; hence, we performed balloon dilatation with a 2.0-mm balloon, which was successfully performed. Yet, the lesion with the embolus immediately recoiled. Finally, a drug-eluting stent was implanted in both the distal lesion with the embolus and the lesion with the calcified nodule. Final coronary angiography showed good results. We confirmed good stent expansion and that calcified nodule was compressed outside the stent. Atherectomy of a calcified nodule is effective at achieving sufficient stent expansion and reducing the risk of vessel perforation. However, we experienced distal embolization of the calcified nodule at the time of rotational atherectomy and so distal embolization should be considered at the time of treatment of calcified nodule.

9.
Int J Cardiovasc Imaging ; 34(10): 1521-1528, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29785558

RESUMEN

We compared first-generation and second-generation drug-eluting stent (DES) with respect to neoatherosclerosis using optical coherence tomography or optical frequency domain imaging. In-stent restenoses in 102 first-generation and 114 second-generation DES were retrospectively assessed. Neoatherosclerosis, which was defined as the presence of lipid-laden neointima or calcification inside a stent, was observed in 33 (27.2%) and 31 (32.4%) lesions in the first-generation and second-generation DES respectively. In the first-generation DES group, the lipid length was significantly longer (5.5 ± 3.8 vs. 3.1 ± 2.1 mm, P = 0.0007), the lipid arc was significantly larger (324 ± 70° vs. 250 ± 94°, P = 0.002), the prevalence of a 360° lipid arc was significantly greater (58 vs. 31%, P = 0.03), and the fibrous cap was significantly thinner (153 ± 85 vs. 211 ± 95 µm, P = 0.02) compared with those in the second-generation DES group. These differences remained significant after adjusting for the age of the stent (lipid length: P < 0.001; lipid arc: P = 0.019; and fibrous cap thickness: P < 0.001). The proliferation course and stability of neoatherosclerosis over time might be superior in second-generation DES.


Asunto(s)
Aterosclerosis/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos/efectos adversos , Tomografía de Coherencia Óptica , Anciano , Anciano de 80 o más Años , Aterosclerosis/etiología , Reestenosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neointima/diagnóstico por imagen , Neointima/etiología , Imagen Óptica , Intervención Coronaria Percutánea , Recurrencia , Reoperación , Estudios Retrospectivos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/etiología
10.
Int Heart J ; 59(3): 630-633, 2018 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-29681575

RESUMEN

A 78-year-old woman had paroxysmal atrial fibrillation and effort angina. Two months before she was admitted for a coronary angiography, she had been feeling dizzy. A Holter 24-hour electrocardiography monitor exhibited an asymptomatic episode of 2.9 seconds of RR interval. She underwent a coronary angiography, which showed intermediate stenosis in the left descending artery. Fractional flow reserve (FFR) measurement using intracoronary papaverine administration was performed. After intracoronary papaverine (12 mg) administration, pause of 4 seconds led to polymorphic ventricular tachycardia (VT), although the VT terminated spontaneously. Premature ventricular beat occurred and led to sustained polymorphic VT. In cardiac electrophysiology study, pacing from the right atrium showed that the maximum sinus node recovery time (SRT) was 910 ms. After procainamide (10 mg/kg) administration, the maximum SRT was 16.3 seconds with some junctional escapes. After intravenous papaverine administration, there was a slight change. Intracoronary papaverine administration induced about 9-seconds pause with some junctional escapes. We conclude that intracoronary papaverine administration reveals potential sinus node dysfunction. The patient has been asymptomatic since the implantation of the pacemaker. Patients with suspicious sinus dysfunction should be careful.


Asunto(s)
Papaverina/efectos adversos , Síndrome del Seno Enfermo/diagnóstico , Taquicardia Ventricular/inducido químicamente , Vasodilatadores/efectos adversos , Anciano , Vasos Coronarios/efectos de los fármacos , Electrocardiografía , Femenino , Reserva del Flujo Fraccional Miocárdico/efectos de los fármacos , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Marcapaso Artificial , Papaverina/administración & dosificación , Síndrome del Seno Enfermo/complicaciones , Síndrome del Seno Enfermo/terapia , Taquicardia Ventricular/terapia , Vasodilatadores/administración & dosificación
11.
Int J Cardiovasc Imaging ; 34(6): 867-874, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29318407

RESUMEN

We aimed to evaluate the optical frequency-domain imaging (OFDI) findings after rotational atherectomy (RA) that predict good stent expansion for severely calcified coronary lesions. Fifty consecutive calcified lesions were subjected to RA under OFDI guidance. We performed OFDI just after RA and stenting. We measured the morphology of calcium after RA, and assessed how these factors influence stent expansion. The stent expansion index was defined as the minimum stent area divided by the average of the proximal and distal reference lumen areas. Minimum thickness of calcification in the intima after RA showed a significant negative correlation with stent expansion (r = - 0.53, P < 0.001), while calcium arc, length, and maximum thickness of calcification in the intima did not. Dissection after RA occurred in 22 lesions (44%), and the stent expansion index was significantly better in dissected lesions than in lesions without dissection (0.96 ± 0.08 vs. 0.82 ± 0.19, P = 0.002). Multiple regression analysis showed that the minimum thickness of calcification in the intima (standardized coefficient: - 0.451, P < 0.001) and dissection formation (standardized coefficient: 0.316, P = 0.011) were predictors of good stent expansion. Minimum of thickness of calcification in the intima and dissection formation were positively associated with good stent expansion after RA. In the clinical setting, achieving these two endpoints should be the aim of RA to ensure good stent expansion.


Asunto(s)
Aterectomía Coronaria , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Calcificación Vascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/terapia , Procedimientos Endovasculares , Femenino , Humanos , Masculino , Intervención Coronaria Percutánea , Estudios Prospectivos , Stents , Resultado del Tratamiento , Calcificación Vascular/terapia
12.
Int J Cardiovasc Imaging ; 34(4): 515-522, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29159531

RESUMEN

Polymeric component is associated with the increased risk of delayed vessel healing and stent endothelialization. We aimed to clarify neointimal coverage within 1 month after implantation of the new-generation abluminal biodegradable polymer (BP) drug-eluting stent (DES) compared with the second-generation durable polymer (DP) everolimus-eluting stent (EES). Between November 2015 and October 2016, 32 BP-DES and 25 DP-EES were evaluated by optical frequency domain imaging (OFDI) within 1 month after the procedure. The average interval to follow-up OFDI was not significantly different between the groups (16.3 ± 7.7 days in BP-DES vs. 15.4 ± 7.4 days in DP-EES, P = 0.75). Neointimal coverage was significantly superior in BP-DES in both apposed and malapposed strut (apposed: 53.9% in BP-DES vs. 28.0% in DP-EES, P < 0.001; malapposed: 22.9% in BP-DES vs. 7.5% in DP-EES, P = 0.001). When the follow-up period was divided into < 2 and > 2 weeks, neointimal coverage was also significantly superior in BP-DES (< 2 weeks: 47.7% in BP-DES vs. 19.2% in DP-EES, P < 0.001; > 2 weeks: 60.1% in BP-DES vs. 37.4% in DP-EES, P = 0.001). The new-generation BP-DES showed excellent early neointimal coverage compared with the second-generation DP-EES in both apposed and malapposed struts.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Neointima , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Anciano , Anciano de 80 o más Años , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Vasos Coronarios/patología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Cicatrización de Heridas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA