Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Curr Drug Metab ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39005122

RESUMEN

OBJECTIVE: 5-Methoxy-α-Methyltryptamine (5-MeO-AMT) is a new psychoactive substance which is abused due to its hallucinogenic and euphoric effects. This study aimed to study the metabolic characteristics of 5-MeO-AMT. METHODS: Five rats were given intraperitoneal injection at a dose of 50 mg/kg of 5-MeO-AMT, and their urine was subsequently collected at different times within 7 days. Ultra-high performance liquid chromatography-- tandem high-resolution mass spectrometry (UPLC-LTQ-Orbitrap) was used to detect the precise molecular weight and fragment ions of 5-MeO-AMT and its possible metabolites in the urine sample extracted with benzene-ethyl acetate. RESULTS: Three metabolites, including OH-5-MeO-AMT, α-Me-5-HT, and N-Acetyl-5-MeO-AMT were identified in rats' urine. The major metabolic pathways involved O-demethylation, hydroxylation of indole ring, and Acetylation on aliphatic amines. CONCLUSION: The results of this study are an important reference for the identification and screening of toxicants of 5-MeO-AMT.

2.
J Am Soc Mass Spectrom ; 35(1): 40-49, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38109269

RESUMEN

A new, rapid, and automated method for the quantitation of 21 synthetic cathinones in urine was established using magnetic dispersive solid-phase extraction (MDSPE) in combination with direct analysis in real time-high-resolution mass spectrometry (DART-HRMS). Sample preparation and quantitation were verified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Methcathinone-D3, α-PVP-D8, and proadifen (SKF525A) were used as internal standards. Magnetic HLB extractant and NaH2PO4/NaOH buffer (0.2 M, pH 7) were used in automatic MDSPE. All 21 synthetic cathinones could be detected and analyzed by DART-HRMS in under 1 min. It was proven that the linearities of 21 synthetic cathinones were suitable (R2 > 0.99) in the concentration ranges of 0.5-100 ng/mL or 1-100 ng/mL. The precision and accuracy values were all within ±15%, and the samples were stable under various conditions. The average time of each sample from preprocessing to completion of detection was approximately 2 min, allowing for rapid sample analysis. The relative error (RE) of the concentrations obtained by DART-HRMS and LC-MS/MS were within ±13.61%, and the linear coefficient (R) was 0.9964. The results of DART-HRMS and LC-MS/MS provided equivalent values at the 95% confidence level. In summary, a simple, fast, and convenient quantitation method via DART-HRMS was established. This application can be utilized to reduce backlogs and promote rapid case processing.


Asunto(s)
Cathinona Sintética , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Extracción en Fase Sólida , Estándares de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA