Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
4.
Crit Care ; 28(1): 286, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39215367

RESUMEN

BACKGROUND: Tracheal intubation (TI)-associated cardiac arrest (TI-CA) occurs in 1.7% of pediatric ICU TIs. Our objective was to evaluate resuscitation characteristics and outcomes between cardiac arrest patients with and without TI-CA. METHODS: Secondary analysis of cardiac arrest patients in both ICU-RESUS trial and ancillary CPR-NOVA study. The primary exposure was TI-CA, defined as cardiac arrest occurred during TI procedure or within 20 min after endotracheal tube placement. The primary outcome was survival to hospital discharge with favorable neurological outcome (Pediatric Cerebral Performance Category score 1-3 or unchanged). RESULTS: Among 315 children with cardiac arrests, 48 (15.2%) met criteria for TI-CA. Pre-existing medical conditions were similar between groups. Pre-arrest non-invasive mechanical ventilation was more common among TI-CA patients (18/48, 37.5%) compared to non-TI-CA patients (35/267, 13.1%). In 48% (23/48), the TI-CA occurred within 20 min after intubation (i.e., not during intubation). Duration of CPR was longer in TI-CA patients (median 11.0 min, interquartile range [IQR]: 2.5, 35.5) than non-TI-CA patients (median 5.0 min, IQR 2.0, 21.0), p = 0.03. Return of spontaneous circulation occurred in 32/48 (66.7%) TI-CA versus 186/267 (69.7%) non-TI-CA, p = 0.73. Survival to hospital discharge with favorable neurological outcome occurred in 29/48 (60.4%) TI-CA versus 146/267 (54.7%) non-TI-CA, p = 0.53. CONCLUSIONS: Fifteen percent of these pediatric ICU cardiac arrests were associated with TI. Half of TI-CA occurred after endotracheal tube placement. While duration of CPR was longer in TI-CA patients, there were no differences in unadjusted outcomes following TI-CA versus non-TI-CA. TRIAL REGISTRATION: The ICU-RESUS (ClinicalTrials.gov Identifier: NCT02837497).


Asunto(s)
Paro Cardíaco , Intubación Intratraqueal , Humanos , Intubación Intratraqueal/estadística & datos numéricos , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/métodos , Masculino , Femenino , Paro Cardíaco/terapia , Paro Cardíaco/mortalidad , Paro Cardíaco/epidemiología , Preescolar , Lactante , Niño , Incidencia , Reanimación Cardiopulmonar/métodos , Reanimación Cardiopulmonar/estadística & datos numéricos , Reanimación Cardiopulmonar/efectos adversos , Unidades de Cuidado Intensivo Pediátrico/estadística & datos numéricos , Unidades de Cuidado Intensivo Pediátrico/organización & administración , Adolescente
6.
OTO Open ; 8(3): e145, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38974176

RESUMEN

Objective: Pediatric tracheostomy is associated with high morbidity and mortality, yet clinician knowledge and quality of tracheostomy care may vary widely. In situ simulation is effective at detecting and mitigating related latent safety threats, but evaluation via retrospective video review has disadvantages (eg, delayed analysis, and potential data loss). We evaluated whether a novel mobile application is accurate and reliable for assessment of in situ tracheostomy emergency simulations. Methods: A novel mobile application was developed for assessment of tracheostomy emergency in situ simulation team performance. After 1.25 hours of training, 6 raters scored 10 tracheostomy emergency simulation videos for the occurrence and timing of 12 critical steps. To assess accuracy, rater scores were compared to a reference standard to determine agreement for occurrence or absence of critical steps and a timestamp within ±5 seconds. Interrater reliability was determined through Cohen's and Fleiss' kappa and intraclass correlation coefficient. Results: Raters had 86.0% agreement with the reference standard when considering step occurrence and timing, and 92.8% agreement when considering only occurrence. The average timestamp difference from the reference standard was 1.3 ± 18.5 seconds. Overall interrater reliability was almost perfect for both step occurrence (Fleiss' kappa of 0.81) and timing of step (intraclass correlation coefficient of 0.99). Discussion: Using our novel mobile application, raters with minimal training accurately and reliably assessed videos of tracheostomy emergency simulations and identified areas for future refinement. Implications for Practice: With refinements, this innovative mobile application is an effective tool for real-time data capture of time-critical steps in in situ tracheostomy emergency simulations.

7.
Pediatr Crit Care Med ; 25(11): 988-997, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39023322

RESUMEN

OBJECTIVES: To evaluate the impact of point-of-care ultrasound (POCUS) use on clinicians within a PICU and to assess infrastructural elements of our POCUS program development. DESIGN: Retrospective observational study. SETTING: Large academic, noncardiac PICU in the United States. SUBJECTS: Patients in a PICU who had diagnostic POCUS performed. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Between January 1, 2017, and December 31, 2022, 7201 diagnostic POCUS studies were ordered; 1930 (26.8%) had a quality assurance (QA) record generated in an independent POCUS QA database. The cardiac domain was most frequently imaged (81.0% of ordered studies, 81.2% of reviewed studies). POCUS images changed clinician understanding of pathophysiology in 563 of 1930 cases (29.2%); when this occurred, management was changed in 318 of 563 cases (56.5%). Cardiac POCUS studies altered clinician suspected pathophysiology in 30.1% of cases (472/1568), compared with 21.5% (91/362) in noncardiac studies ( p = 0.06). Among cases where POCUS changed clinician understanding, management changed more often following cardiac than noncardiac POCUS ( p = 0.02). Clinicians identified a need for cardiology consultation or complete echocardiograms in 294 of 1568 cardiac POCUS studies (18.8%). Orders for POCUS imaging increased by 94.9%, and revenue increased by 159.4%, from initial to final study year. QA database use by both clinicians and reviewers decreased annually as QA processes evolved in the setting of technologic growth and unit expansion. CONCLUSIONS: Diagnostic POCUS imaging in the PICU frequently yields information that alters diagnosis and changes management. As PICU POCUS use increased, QA processes evolved resulting in decreased use of our initial QA database. Modifications to QA processes are likely necessary as clinical contexts change over time.


Asunto(s)
Unidades de Cuidado Intensivo Pediátrico , Sistemas de Atención de Punto , Ultrasonografía , Humanos , Unidades de Cuidado Intensivo Pediátrico/organización & administración , Estudios Retrospectivos , Ultrasonografía/métodos , Ultrasonografía/estadística & datos numéricos , Niño , Lactante , Preescolar , Masculino , Femenino , Estados Unidos , Garantía de la Calidad de Atención de Salud/métodos , Adolescente , Recién Nacido
8.
Pediatr Emerg Care ; 40(8): 575-581, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39078284

RESUMEN

OBJECTIVES: To inform development of a preintubation checklist for pediatric emergency departments via multicenter usability testing of a prototype checklist. METHODS: This was a prospective, mixed methods study across 7 sites in the National Emergency Airway Registry for Pediatric Emergency Medicine (NEAR4PEM) collaborative. Pediatric emergency medicine attending physicians and senior fellows at each site were first oriented to a checklist prototype, including content previously identified using a modified Delphi approach. Each site used the checklist in 2 simulated cases: an "easy airway" and a "difficult airway" scenario. Facilitators recorded verbalization, completion, and timing of checklist items. After each simulation, participants completed an anonymous usability survey. Structured debriefings were used to gather additional feedback on checklist usability. Comments from the surveys and debriefing were qualitatively analyzed using a framework approach. Responses informed human factors-based optimization of the checklist. RESULTS: Fifty-five pediatric emergency medicine physicians/fellows (4-13 per site) participated. Participants found the prototype checklist to be helpful, easy to use, clear, and of appropriate length. During the simulations, 93% of checklist items were verbalized and more than 80% were completed. Median time to checklist completion was 6.2 minutes (interquartile range, 4.8-7.1) for the first scenario and 4.2 minutes (interquartile range, 2.7-5.8) for the second. Survey and debriefing data identified the following strengths: facilitating a shared mental model, cognitively offloading the team leader, and prompting contingency planning. Suggestions for checklist improvement included clarifying specific items, providing more detailed prompts, and allowing institution-specific customization. Integration of these data with human factors heuristic inspection resulted in a final checklist. CONCLUSIONS: Simulation-based, human factors usability testing of the National Emergency Airway Registry for Pediatric Emergency Medicine Preintubation Checklist allowed optimization prior to clinical implementation. Next steps involve integration into real-world settings utilizing rigorous implementation science strategies, with concurrent evaluation of the impact on patient outcomes and safety.


Asunto(s)
Lista de Verificación , Intubación Intratraqueal , Humanos , Estudios Prospectivos , Intubación Intratraqueal/métodos , Servicio de Urgencia en Hospital , Sistema de Registros , Entrenamiento Simulado/métodos , Medicina de Emergencia , Encuestas y Cuestionarios , Masculino , Femenino , Ergonomía
9.
Pediatr Emerg Care ; 40(8): 586-590, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38875463

RESUMEN

OBJECTIVES: Early shock reversal is crucial to improve patient outcomes. Capillary refill time (CRT) is clinically important to identify and monitor shock in children but has issues with inconsistency. To minimize inconsistency, we evaluated a CRT monitoring system using an automated compression device. Our objective was to determine proper compression pressure in children. METHODS: Clinician force for CRT was collected during manual CRT measurement as a reference for automated compression in a previous study (12.9 N, 95% confidence interval, 12.5-13.4; n = 454). An automated compression device with a soft inflation bladder was fitted with a force sensor. We evaluated the effectiveness of the automated pressure to eliminate pulsatile blood flow from the distal phalange. Median and variance of CRT analysis at each pressure was compared. RESULTS: A comparison of pressures at 300 to 500 mm Hg on a simulated finger yielded a force of 5 to 10 N, and these pressures were subsequently used for automated compression for CRT. Automated compression was tested in 44 subjects (median age, 33 months; interquartile range [IQR], 14-56 months). At interim analysis of 17 subjects, there was significant difference in the waveform with residual pulsatile blood flow (9/50: 18% at 300 mm Hg, 5/50:10% at 400 mm Hg, 0/51: 0% at 500 mm Hg, P = 0.008). With subsequent enrollment of 27 subjects at 400 and 500 mm Hg, none had residual pulsatile blood flow. There was no difference in the CRT: median 1.8 (IQR, 1.06-2.875) in 400 mm Hg vs median 1.87 (IQR, 1.25-2.8325) in 500 mm Hg, P = 0.81. The variance of CRT was significantly larger in 400 mm Hg: 2.99 in 400 mm Hg vs. 1.35 in 500 mm Hg, P = 0.02, Levene's test. Intraclass correlation coefficient for automated CRT was 0.56 at 400 mm Hg and 0.78 at 500 mm Hg. CONCLUSIONS: Using clinician CRT measurement data, we determined either 400 or 500 mm Hg is an appropriate pressure for automated CRT, although 500 mm Hg demonstrates superior consistency.


Asunto(s)
Capilares , Dedos , Humanos , Dedos/irrigación sanguínea , Masculino , Femenino , Preescolar , Lactante , Capilares/fisiología , Flujo Pulsátil/fisiología , Choque/fisiopatología , Choque/diagnóstico , Choque/terapia , Niño , Presión , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Automatización
10.
Pediatr Emerg Care ; 40(6): 469-473, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38713851

RESUMEN

OBJECTIVES: Information obtained from point-of-care ultrasound during cardiopulmonary arrest and resuscitation (POCUS-CA) can be used to identify underlying pathophysiology and provide life-sustaining interventions. However, integration of POCUS-CA into resuscitation care is inconsistent. We used expert consensus building methodology to help identify discrete barriers to clinical integration. We subsequently applied implementation science frameworks to generate generalizable strategies to overcome these barriers. MEASURES AND MAIN RESULTS: Two multidisciplinary expert working groups used KJ Reverse-Merlin consensus building method to identify and characterize barriers contributing to failed POCUS-CA utilization in a hypothetical future state. Identified barriers were organized into affinity groups. The Center for Implementation Research (CFIR) framework and Expert Recommendations for Implementing Change (CFIR-ERIC) tool were used to identify strategies to guide POCUS-US implementation. RESULTS: Sixteen multidisciplinary resuscitation content experts participated in the working groups and identified individual barriers, consolidated into 19 unique affinity groups that mapped 12 separate CFIR constructs, representing all 5 CFIR domains. The CFIR-ERIC tool identified the following strategies as most impactful to address barriers described in the affinity groups: identify and prepare champions, conduct local needs assessment, conduct local consensus discussions, and conduct educational meetings. CONCLUSIONS: KJ Reverse-Merlin consensus building identified multiple barriers to implementing POCUS-CA. Implementation science methodologies identified and prioritized strategies to overcome barriers and guide POCUS-CA implementation across diverse clinical settings.


Asunto(s)
Reanimación Cardiopulmonar , Paro Cardíaco , Ultrasonografía , Humanos , Reanimación Cardiopulmonar/métodos , Paro Cardíaco/terapia , Ultrasonografía/métodos , Sistemas de Atención de Punto , Consenso , Ciencia de la Implementación
12.
Pediatrics ; 153(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38469643

RESUMEN

BACKGROUND AND OBJECTIVES: Neonatal endotracheal tube (ETT) size recommendations are based on limited evidence. We sought to determine data-driven weight-based ETT sizes for infants undergoing tracheal intubation and to compare these with Neonatal Resuscitation Program (NRP) recommendations. METHODS: Retrospective multicenter cohort study from an international airway registry. We evaluated ETT size changes (downsizing to a smaller ETT during the procedure or upsizing to a larger ETT within 7 days) and risk of procedural adverse outcomes associated with first-attempt ETT size selection when stratifying the cohort into 200 g subgroups. RESULTS: Of 7293 intubations assessed, the initial ETT was downsized in 5.0% of encounters and upsized within 7 days in 1.5%. ETT downsizing was most common when NRP-recommended sizes were attempted in the following weight subgroups: 1000 to 1199 g with a 3.0 mm (12.6%) and 2000 to 2199 g with a 3.5 mm (17.1%). For infants in these 2 weight subgroups, selection of ETTs 0.5 mm smaller than NRP recommendations was independently associated with lower odds of adverse outcomes compared with NRP-recommended sizes. Among infants weighing 1000 to 1199 g: any tracheal intubation associated event, 20.8% with 2.5 mm versus 21.9% with 3.0 mm (adjusted OR [aOR] 0.62, 95% confidence interval [CI] 0.41-0.94); severe oxygen desaturation, 35.2% with 2.5 mm vs 52.9% with 3.0 mm (aOR 0.53, 95% CI 0.38-0.75). Among infants weighing 2000 to 2199 g: severe oxygen desaturation, 41% with 3.0 mm versus 56% with 3.5mm (aOR 0.55, 95% CI 0.34-0.89). CONCLUSIONS: For infants weighing 1000 to 1199 g and 2000 to 2199 g, the recommended ETT size was frequently downsized during the procedure, whereas 0.5 mm smaller ETT sizes were associated with fewer adverse events and were rarely upsized.


Asunto(s)
Intubación Intratraqueal , Resucitación , Humanos , Recién Nacido , Estudios de Cohortes , Intubación Intratraqueal/métodos , Oxígeno
13.
Artículo en Inglés | MEDLINE | ID: mdl-38404646

RESUMEN

Background: Nasal tracheal intubation (TI) represents a minority of all TI in the pediatric intensive care unit (PICU). The risks and benefits of nasal TI are not well quantified. As such, safety and descriptive data regarding this practice are warranted. Methods: We evaluated the association between TI route and safety outcomes in a prospectively collected quality improvement database (National Emergency Airway Registry for Children: NEAR4KIDS) from 2013 to 2020. The primary outcome was severe desaturation (SpO2 > 20% from baseline) and/or severe adverse TI-associated events (TIAEs), using NEAR4KIDS definitions. To balance patient, provider, and practice covariates, we utilized propensity score (PS) matching to compare the outcomes of nasal vs. oral TI. Results: A total of 22,741 TIs [nasal 870 (3.8%), oral 21,871 (96.2%)] were reported from 60 PICUs. Infants were represented in higher proportion in the nasal TI than the oral TI (75.9%, vs 46.2%), as well as children with cardiac conditions (46.9% vs. 14.4%), both p < 0.001. Severe desaturation or severe TIAE occurred in 23.7% of nasal and 22.5% of oral TI (non-adjusted p = 0.408). With PS matching, the prevalence of severe desaturation and or severe adverse TIAEs was 23.6% of nasal vs. 19.8% of oral TI (absolute difference 3.8%, 95% confidence interval (CI): - 0.07, 7.7%), p = 0.055. First attempt success rate was 72.1% of nasal TI versus 69.2% of oral TI, p = 0.072. With PS matching, the success rate was not different between two groups (nasal 72.2% vs. oral 71.5%, p = 0.759). Conclusion: In this large international prospective cohort study, the risk of severe peri-intubation complications was not significantly higher. Nasal TI is used in a minority of TI in PICUs, with substantial differences in patient, provider, and practice compared to oral TI.A prospective multicenter trial may be warranted to address the potential selection bias and to confirm the safety of nasal TI.

14.
Respir Care ; 69(7): 869-880, 2024 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-38346842

RESUMEN

Invasive mechanical ventilation is prevalent and associated with considerable morbidity. Pediatric critical care teams must identify the best timing and approach to liberating (extubating) children from this supportive care modality. Unsurprisingly, practice variation varies widely. As a first step to minimizing that variation, the first evidence-based pediatric ventilator liberation guidelines were published in 2023 and included 15 recommendations. Unfortunately, there is often a substantial delay before clinical guidelines reach widespread clinical practice. As such, it is important to consider barriers and facilitators using a systematic approach during implementation planning and design. In this narrative review, we will (1) summarize guideline recommendations, (2) discuss recent evidence and identify practice gaps relating to those recommendations, and (3) hypothesize about potential barriers and facilitators to their implementation in clinical practice.


Asunto(s)
Guías de Práctica Clínica como Asunto , Desconexión del Ventilador , Humanos , Niño , Desconexión del Ventilador/normas , Desconexión del Ventilador/métodos , Respiración Artificial/normas , Respiración Artificial/métodos , Cuidados Críticos/normas , Cuidados Críticos/métodos , Medicina Basada en la Evidencia , Pediatría/normas
15.
Arch Dis Child Fetal Neonatal Ed ; 109(6): 609-615, 2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-38418208

RESUMEN

OBJECTIVE: To determine the factors associated with second attempt success and the risk of adverse events following a failed first attempt at neonatal tracheal intubation. DESIGN: Retrospective analysis of prospectively collected data on intubations performed in the neonatal intensive care unit (NICU) and delivery room from the National Emergency Airway Registry for Neonates (NEAR4NEOS). SETTING: Eighteen academic NICUs in NEAR4NEOS. PATIENTS: Neonates requiring two or more attempts at intubation between October 2014 and December 2021. MAIN OUTCOME MEASURES: The primary outcome was successful intubation on the second attempt, with severe tracheal intubation-associated events (TIAEs) or severe desaturation (≥20% decline in oxygen saturation) being secondary outcomes. Multivariate regression examined the associations between these outcomes and patient characteristics and changes in intubation practice. RESULTS: 5805 of 13 126 (44%) encounters required two or more intubation attempts, with 3156 (54%) successful on the second attempt. Second attempt success was more likely with changes in any of the following: intubator (OR 1.80, 95% CI 1.56 to 2.07), stylet use (OR 1.65, 95% CI 1.36 to 2.01) or endotracheal tube (ETT) size (OR 2.11, 95% CI 1.74 to 2.56). Changes in stylet use were associated with a reduced chance of severe desaturation (OR 0.74, 95% CI 0.61 to 0.90), but changes in intubator, laryngoscope type or ETT size were not; no changes in intubator or equipment were associated with severe TIAEs. CONCLUSIONS: Successful neonatal intubation on a second attempt was more likely with a change in intubator, stylet use or ETT size.


Asunto(s)
Unidades de Cuidado Intensivo Neonatal , Intubación Intratraqueal , Sistema de Registros , Humanos , Intubación Intratraqueal/estadística & datos numéricos , Intubación Intratraqueal/métodos , Recién Nacido , Estudios Retrospectivos , Femenino , Masculino , Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Insuficiencia del Tratamiento
16.
Respir Care ; 69(2): 184-190, 2024 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-38164617

RESUMEN

BACKGROUND: Unplanned extubation (UE) is defined as unintentional dislodgement of an endotracheal tube (ETT) from the trachea. UEs can lead to instability, cardiac arrest, and may require emergent tracheal re-intubation. As part of our hospital-wide quality improvement (QI) work, a multidisciplinary committee reviewed all UEs to determine contributing factors and evaluation of clinical outcomes to develop QI interventions aimed to minimize UEs. The objective was to investigate occurrence, contributing factors, and clinical outcomes of UEs in the pediatric ICU (PICU), cardiac ICU (CICU), and neonatal ICU (NICU) in a large academic children's hospital. We hypothesized that these would be substantially different across 3 ICUs. METHODS: A single-center retrospective review of UEs in the PICU, CICU, and NICU was recorded in a prospective database for the last 5 y. Consensus-based standardized operational definitions were developed to capture contributing factors and adverse events associated with UEs. Data were extracted through electronic medical records by 3 respiratory therapists and local Virtual Pediatric Systems (VPS) database. Consistency of data extraction and classification were evaluated. RESULTS: From January 2016-December 2021, 408 UEs in 339 subjects were reported: PICU 52 (13%), CICU 31 (7%), and NICU 325 (80%). The median (interquartile range) of age and weight was 2.0 (0-4.0) months and 5.3 (3.0-8.0) kg. Many UE events were not witnessed (54%). Common contributing factors were routine nursing care (no. = 70, 18%), ETT retaping (no. = 62, 16%), and being held (no. = 15, 3.9%). The most common adverse events with UE were desaturation < 80% (33%) and bradycardia (22.8%). Cardiac arrest occurred in 12%. Sixty-seven percent of UEs resulted in re-intubation within 72 h. The proportion of re-intubation across 3 units was significantly different: PICU 62%, CICU 35%, NICU 71%, P < .001. CONCLUSIONS: UEs occurred commonly in a large academic children's hospital. Whereas UE was associated with adverse events, re-intubation rates within 72 h were < 70% and variable across the units.


Asunto(s)
Extubación Traqueal , Paro Cardíaco , Recién Nacido , Humanos , Niño , Extubación Traqueal/métodos , Factores de Riesgo , Unidades de Cuidado Intensivo Neonatal , Unidades de Cuidado Intensivo Pediátrico , Intubación Intratraqueal/efectos adversos , Paro Cardíaco/terapia
17.
Pediatr Crit Care Med ; 25(4): 335-343, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38059735

RESUMEN

OBJECTIVES: Children with trisomy 21 often have anatomic and physiologic features that may complicate tracheal intubation (TI). TI in critically ill children with trisomy 21 is not well described. We hypothesize that in children with trisomy 21, TI is associated with greater odds of adverse airway outcomes (AAOs), including TI-associated events (TIAEs), and peri-intubation hypoxemia (defined as > 20% decrease in pulse oximetry saturation [Sp o2 ]). DESIGN: Retrospective database study using the National Emergency Airway Registry for Children (NEAR4KIDS). SETTING: Registry data from 16 North American PICUs and cardiac ICUs (CICUs), from January 2014 to December 2020. PATIENTS: A cohort of children under 18 years old who underwent TI in the PICU or CICU from in a NEAR4KIDS center. We identified patients with trisomy 21 and selected matched cohorts within the registry. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We included 8401 TIs in the registry dataset. Children with trisomy 21 accounted for 274 (3.3%) TIs. Among those with trisomy 21, 84% had congenital heart disease and 4% had atlantoaxial instability. Cervical spine protection was used in 6%. The diagnosis of trisomy 21 (vs. without) was associated with lower median weight 7.8 (interquartile range [IQR] 4.5-14.7) kg versus 10.6 (IQR 5.2-25) kg ( p < 0.001), and more higher percentage undergoing TI for oxygenation (46% vs. 32%, p < 0.001) and ventilation failure (41% vs. 35%, p = 0.04). Trisomy 21 patients had more difficult airway features (35% vs. 25%, p = 0.001), including upper airway obstruction (14% vs. 8%, p = 0.001). In addition, a greater percentage of trisomy 21 patients received atropine (34% vs. 26%, p = 0.004); and, lower percentage were intubated with video laryngoscopy (30% vs. 37%, p = 0.023). After 1:10 (trisomy 21:controls) propensity-score matching, we failed to identify an association difference in AAO rates (absolute risk difference -0.6% [95% CI -6.1 to 4.9], p = 0.822). CONCLUSIONS: Despite differences in airway risks and TI approaches, we have not identified an association between the diagnosis of trisomy 21 and higher AAOs.


Asunto(s)
Síndrome de Down , Laringoscopios , Niño , Humanos , Adolescente , Estudios Retrospectivos , Síndrome de Down/complicaciones , Unidades de Cuidado Intensivo Pediátrico , Intubación Intratraqueal/efectos adversos , Manejo de la Vía Aérea
18.
Pediatr Crit Care Med ; 25(2): 147-158, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37909825

RESUMEN

OBJECTIVES: Extremes of patient body mass index are associated with difficult intubation and increased morbidity in adults. We aimed to determine the association between being underweight or obese with adverse airway outcomes, including adverse tracheal intubation (TI)-associated events (TIAEs) and/or severe peri-intubation hypoxemia (pulse oximetry oxygen saturation < 80%) in critically ill children. DESIGN/SETTING: Retrospective cohort using the National Emergency Airway for Children registry dataset of 2013-2020. PATIENTS: Critically ill children, 0 to 17 years old, undergoing TI in PICUs. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Registry data from 24,342 patients who underwent TI between 2013 and 2020 were analyzed. Patients were categorized using the Centers for Disease Control and Prevention weight-for-age chart: normal weight (5th-84th percentile) 57.1%, underweight (< 5th percentile) 27.5%, overweight (85th to < 95th percentile) 7.2%, and obese (≥ 95th percentile) 8.2%. Underweight was most common in infants (34%); obesity was most common in children older than 8 years old (15.1%). Underweight patients more often had oxygenation and ventilation failure (34.0%, 36.2%, respectively) as the indication for TI and a history of difficult airway (16.7%). Apneic oxygenation was used more often in overweight and obese patients (19.1%, 19.6%) than in underweight or normal weight patients (14.1%, 17.1%; p < 0.001). TIAEs and/or hypoxemia occurred more often in underweight (27.1%) and obese (24.3%) patients ( p < 0.001). TI in underweight children was associated with greater odds of adverse airway outcome compared with normal weight children after adjusting for potential confounders (underweight: adjusted odds ratio [aOR], 1.09; 95% CI, 1.01-1.18; p = 0.016). Both underweight and obesity were associated with hypoxemia after adjusting for covariates and site clustering (underweight: aOR, 1.11; 95% CI, 1.02-1.21; p = 0.01 and obesity: aOR, 1.22; 95% CI, 1.07-1.39; p = 0.002). CONCLUSIONS: In underweight and obese children compared with normal weight children, procedures around the timing of TI are associated with greater odds of adverse airway events.


Asunto(s)
Enfermedad Crítica , Obesidad Infantil , Lactante , Niño , Humanos , Recién Nacido , Preescolar , Adolescente , Estudios Retrospectivos , Sobrepeso/etiología , Obesidad Infantil/complicaciones , Obesidad Infantil/epidemiología , Delgadez/complicaciones , Delgadez/epidemiología , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/métodos , Hipoxia/epidemiología , Hipoxia/etiología , Sistema de Registros
19.
Pediatr Crit Care Med ; 25(2): 139-146, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37882620

RESUMEN

OBJECTIVES: To describe tracheal intubation (TI) practice by Advanced Practice Registered Nurses (APRNs) in North American PICUs, including rates of TI-associated events (TIAEs) from 2015 to 2019. DESIGN/SETTING: Retrospective study using the National Emergency Airway Registry for Children with all TIs performed in PICU and pediatric cardiac ICU between January 2015 and December 2019. The primary outcome was first attempt TI success rate. Secondary outcomes were TIAEs, severe TIAEs, and hypoxemia. SUBJECTS: Critically ill children requiring TI in a PICU or pediatric cardiac ICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among 11,012 TIs, APRNs performed 1,626 (14.7%). Overall, TI by APRNs, compared with other clinicians, occurred less frequently in patients with known difficult airway (11.1% vs. 14.3%; p < 0.001), but more frequently in infants younger than 1 year old (55.9% vs. 44.4%; p < 0.0001), and in patients with cardiac disease (26.3% vs. 15.9%; p < 0.0001).There was lower odds of success in first attempt TI for APRNs vs. other clinicians (adjusted odds ratio, 0.70; 95% CI, 0.62-0.79). We failed to identify a difference in rates of TIAE, severe TIAE, and oxygen desaturation events for TIs by APRNs compared with other clinicians. The TI first attempt success rate improved with APRN experience (< 1 yr: 54.2%, 1-5 yr: 59.4%, 6-10 yr: 67.6%, > 10 yr: 63.1%; p = 0.021). CONCLUSIONS: TI performed by APRNs was associated with lower odds of first attempt success when compared with other ICU clinicians although there was no appreciable difference in procedural adverse events. There appears to be a positive relationship between experience and success rates. These data suggest there is an ongoing need for opportunities to build on TI competency with APRNs.


Asunto(s)
Enfermería de Práctica Avanzada , Enfermeras y Enfermeros , Lactante , Niño , Humanos , Estudios Retrospectivos , Enfermedad Crítica/terapia , Intubación Intratraqueal/efectos adversos , Sistema de Registros , Cuidados Críticos
20.
Pediatr Pulmonol ; 59(2): 433-441, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38038168

RESUMEN

BACKGROUND: Ultrasound-based diaphragmatic assessments are becoming more common in pediatric acute care, but baseline pediatric diaphragm thickness and contractility values remain unknown. METHODS: We conducted a prospective, observational study of healthy children aged <18 years undergoing elective surgery. Diaphragm thickness at end-expiration (Tdi-exp), thickening fraction (DTF) and excursion were measured by ultrasound during spontaneous breathing and during mechanical ventilation. Diaphragm strain and peak strain rate were ascertained post hoc. Measurements were compared across a priori specified age groups (<1 year, 1 to <3, 3 to <6, 6 to <12, and 12 to <18 years) and with versus without mechanical ventilation. RESULTS: Fifty subjects were evaluated (n = 10 per age group). Baseline mean Tdi-exp was 0.19 ± 0.04 cm, DTF 0.19 ± 0.09, excursion 1.69 ± 0.97 cm, strain -10.3 ± 4.9, peak strain rate -0.48 ± 0.21 s-1 . No significant difference in Tdi-exp or DTF was observed across age groups (p > .05). Diaphragm excursion increased with age (p < .0001). Diaphragm strain was significantly greater in the 12-17-year age group (-14.3 ± 6.4), p = .048, but there were no age-related differences in peak strain rate (p = .08). During mechanical ventilation, there were significant decreases in DTF 0.12 ± 0.04 (p < .0001), excursion 1.08 ± 0.31 cm (p < .0001), strain -4.60 ± 1.93 (p < .0001), and peak strain rate -0.20 ± 0.10 s-1 (p < .0001) while there was no change in Tdi-exp 0.18 ± 0.03 cm (p = .25) when compared to baseline values. CONCLUSION: Pediatric Tdi-exp, DTF, and diaphragm peak strain rate were similar across age groups. Diaphragm excursion and strain varied across age groups. All measures of diaphragm contractility were diminished during mechanical ventilation.


Asunto(s)
Diafragma , Respiración Artificial , Humanos , Niño , Adolescente , Diafragma/diagnóstico por imagen , Estudios Prospectivos , Tórax , Respiración , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA