1.
J Infect Chemother ; 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38906374

RESUMEN

A 21-year-old previously healthy Japanese woman visited an outpatient clinic because of abdominal pain, watery diarrhea, vomiting, and mild fever that had started on the previous day. She traveled to rural and urban areas of Rwanda and returned to Japan 3 days before. Stool culture yielded the Plesiomonas shigelloides strain TMCH301018, against which minimum inhibitory concentrations of cefotaxime and cefotaxime-clavulanate were 128 and ≤0.12/4 µg/mL, respectively. The strain had the blaCTX-M-27 gene and an IncA/C replicon-type plasmid. Moreover, a transformant produced by introduction of an IncA/C plasmid extracted from TMCH301018 into Escherichia coli DH5α was positive for the blaCTX-M-27 gene and fulfilled the criteria of extended-spectrum ß-lactamase (ESBL) production described by the Clinical and Laboratory Standards Institute, indicating that TMCH301018 produced ESBL of CTX-M-27 and the ESBL-encoding gene was located on an IncA/C plasmid. Pathogenicity of TMCH301018 for the patient's complaints was uncertain because a molecular assay detected other enteropathogens in the stool specimen and the symptoms improved within 2 days with administration of oral ciprofloxacin, to which TMCH301018 was not susceptible. To our knowledge, this is the first report describing the isolation of ESBL-producing P. shigelloides.

2.
Sci Rep ; 13(1): 17546, 2023 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-37845364

RESUMEN

We designed and developed two new types of hydrogen fuel cell (HFC) buses (motorcoach and minibus) with a mobile laboratory system. Feasibility studies have been performed for mobile laboratory testing, particularly for the laboratory performance of COVID-19 RT-PCR (PCR). We evaluated the driving range capability, PCR sample size capacity, turnaround time (TAT), and analytical performance for the detection of SARS-CoV-2. Saliva samples were used for the current study, and the analytical performance was compared with that of the reference PCR. The estimated driving range and sample size capacity of the HFC and HFC minibus were 432 km and 2847 samples, respectively, for the HFC motorcoach and 313 km and 1949 samples for the HFC minibus. For the TAT, the median time between sample submission and completion of PCR was 86 min for the motorcoach and 76 min for the minibus, and the median time between sample submission and electronic reporting of the result to each visitor was 182 min for the motorcoach and 194 min for the minibus. A secondary analysis of 1574 HFC mobile laboratory testing samples was conducted, and all negative samples were found to be negative by reference PCR. Furthermore, all samples were confirmed to be positive by reference PCR or other molecular examinations.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Prueba de Ácido Nucleico para COVID-19 , Prueba de COVID-19 , Vehículos a Motor , Sensibilidad y Especificidad
3.
J Infect Chemother ; 29(7): 654-659, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36894015

RESUMEN

INTRODUCTION: Rapid qualitative antigen testing has been widely used for the laboratory diagnosis of COVID-19 with nasopharyngeal samples. Saliva samples have been used as alternative samples, but the analytical performance of those samples for qualitative antigen testing has not been sufficiently evaluated. METHODS: A prospective observational study evaluated the analytical performance of three In Vitro Diagnostics (IVD) approved COVID-19 rapid antigen detection kits for saliva between June 2022 and July 2022 in Japan using real-time reverse transcription polymerase chain reaction (RT-qPCR) as a reference. A nasopharyngeal sample and a saliva sample were simultaneously obtained, and RT-qPCR was performed. RESULTS: In total, saliva samples and nasopharyngeal samples were collected from 471 individuals (RT-qPCR-positive, n = 145) for the analysis. Of these, 96.6% were symptomatic. The median copy numbers were 1.7 × 106 copies/mL for saliva samples and 1.2 × 108 copies/mL for nasopharyngeal samples (p < 0.001). Compared with the reference, the sensitivity and specificity were 44.8% and 99.7% for ImunoAce SARS-CoV-2 Saliva, 57.2% and 99.1% for Espline SARS-CoV-2 N, and 60.0% and 99.1% for QuickChaser Auto SARS-CoV-2, respectively. The sensitivities of all antigen testing kit were 100% for saliva samples with a high viral load (>107 copies/mL), whereas the sensitivities were <70% for high-viral-load nasopharyngeal samples (>107 copies/mL). CONCLUSION: COVID-19 rapid antigen detection kits with saliva showed high specificity, but the sensitivity varied among kits, and were also insufficient for the detection of symptomatic COVID-19 patients.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Estudios Prospectivos , Japón , Saliva , Sensibilidad y Especificidad , Nasofaringe , Manejo de Especímenes
4.
J Gen Fam Med ; 24(2): 102-109, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36909784

RESUMEN

Background: Microscopic examination of stool samples can contribute to the early diagnosis of Campylobacter gastroenteritis. However, it is unclear whether the diagnostic performance is reliable when performed by physicians. Methods: This prospective study included fresh stool samples collected from patients with gastroenteritis between August 2018 and March 2020. The samples were used for microscopic examination through Gram staining. Two physicians, a clinical laboratory technician, and microbiologists performed the examinations. In addition, antigen tests (QuickNavi-Campylobacter; Denka Co., Ltd.) were evaluated for the samples collected between May 2019 and March 2020. Infection with Campylobacter spp. was confirmed when stool cultures or polymerase chain reaction tests provided positive results. Results: Microscopic examination was performed on 205 samples, of which 46 (22.4%) were positive for Campylobacter spp. For the microscopic examination, the sensitivity and specificity were 53.5% and 98.1% for physician A, 46.7% and 96.2% for physician B, 63.0% and 100% for the clinical laboratory technician, and 67.4% and 100% for microbiologists, respectively. The antigen testing was evaluated in 131 of the 205 samples and showed a sensitivity of 93.3% and specificity of 99.0%. Conclusions: Microscopic examination of the stool samples showed high specificity. The sensitivity when the examinations were performed by the physicians was insufficient. The rapid antigen tests can reliably detect Campylobacter spp. in stool samples.

5.
J Infect Chemother ; 29(3): 257-262, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36417995

RESUMEN

INTRODUCTION: Rapid qualitative antigen testing is essential in the clinical management of COVID-19. However, most evaluations of antigen tests have been performed before the emergence of the Omicron variant. METHODS: This prospective observational study evaluated QuickNavi-COVID19 Ag, a rapid antigen detection test between December 2021 and February 2022 in Japan, using real-time reverse transcription (RT)-PCR as a reference. Two nasopharyngeal samples were simultaneously collected for antigen testing and for RT-PCR. Variant analysis of the SARS-CoV-2 genomic sequencing was also performed. RESULTS: In total, nasopharyngeal samples were collected from 1073 participants (417 positive; 919 symptomatic; 154 asymptomatic) for analysis. Compared with those of RT-PCR, the sensitivity, specificity, positive predictive value, and negative predictive value were 94.2% (95% CI: 91.6%-96.3%), 99.5% (95% CI: 98.7%-99.9%), 99.2% (95% CI: 97.8%-99.8%), and 96.5% (95% CI: 94.8%-97.7%), respectively. The sensitivity among symptomatic individuals was 94.3% (95% CI: 91.5%-96.4%). Overall, 85.9% of sequences were classified as Omicron sublineage BA.1, 12.4% were Omicron sublineage BA.2, and 1.6% were Delta B.1.617.2. (Delta variant). Most of the samples (87.1%) had Ct values of <25, and the sensitivity was 47.4% for low viral load samples (Ct ≥ 30); a similar trend has been observed in both symptomatic and asymptomatic groups. CONCLUSIONS: The QuickNavi-COVID19 Ag test showed sufficient diagnostic performance for the detection of the SARS-CoV-2 Omicron sublineages BA.1 and BA.2 from nasopharyngeal samples. However, the current study was mainly performed in symptomatic patients and the results are not sufficiently applicable for asymptomatic patients.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Japón , Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad
6.
Mol Diagn Ther ; 26(3): 323-331, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35391608

RESUMEN

BACKGROUND AND OBJECTIVE: Point-of-care type molecular diagnostic tests have been used for detecting SARS-CoV-2, although their clinical utility with nasal samples has yet to be established. This study evaluated the clinical performance of the cobas Liat SARS-CoV-2 & Influenza A/B (Liat) assay in nasal samples. METHODS: Nasal and nasopharyngeal samples were collected and were tested using the Liat, the cobas 6800 system and the cobas SARS-CoV-2 & Influenza A/B (cobas), and a method developed by National Institute of Infectious Diseases, Japan (NIID). RESULTS: A total of 814 nasal samples were collected. The Liat assay was positive for SARS-CoV-2 in 113 (13.9%). The total, positive, and negative concordance rate between the Liat and cobas/NIID assays were 99.3%/98.4%, 99.1%/100%, and 99.3%/98.2%, respectively. Five samples were positive only using the Liat assay. Their Ct values ranged from 31.9 to 37.2. The Ct values of the Liat assay were significantly lower (p < 0.001) but were correlated (p < 0.001) with those of other molecular assays. In the participants who tested positive for SARS-CoV-2 on the Liat assay using nasopharyngeal samples, 88.2% of their nasal samples also tested positive using the Liat assay. CONCLUSION: The Liat assay showed high concordance with other molecular assays in nasal samples. Some discordance occurred in samples with Ct values > 30 on the Liat assay.


Asunto(s)
COVID-19 , Gripe Humana , COVID-19/diagnóstico , Humanos , Gripe Humana/diagnóstico , Nasofaringe , SARS-CoV-2 , Sensibilidad y Especificidad
7.
J Infect Chemother ; 28(6): 780-785, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35256268

RESUMEN

INTRODUCTION: The diagnostic accuracy of antigen testing of anterior nasal (AN) samples for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has not been evaluated in the Japanese population. This study assessed the diagnostic accuracy of the Roche SARS-CoV-2 rapid antigen test (rapid antigen test) using AN samples. METHODS: Two AN samples and one nasopharyngeal (NP) sample were collected from individuals undergoing screening for SARS-CoV-2 infection. The results of the rapid antigen test and the reverse-transcription polymerase chain reaction (RT-PCR) test using AN samples were compared to those of RT-PCR tests using NP samples. RESULTS: Samples were collected from 800 participants, 95 and 110 of whom tested positive for SARS-CoV-2 on RT-PCR tests of AN and NP samples, respectively. The overall sensitivity/specificity of the AN rapid antigen test and AN RT-PCR were 72.7%/100% and 86.4%/100%, respectively. In symptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 84.7% and 94.9%, respectively. In asymptomatic cases, the sensitivities of the AN rapid antigen test and AN RT-PCR were 58.8% and 76.5%, respectively. The sensitivity of the AN rapid antigen test was over 80% in cases with cycle threshold (Ct) values < 25; it significantly decreased with an increase in the Ct values (p < 0.001). CONCLUSION: The rapid antigen test with AN samples had a favorable sensitivity, especially in symptomatic cases or in cases with Ct values < 25. It gave no false-positive results. Compared with AN-RT PCR, the AN rapid antigen test had a modestly lower sensitivity in asymptomatic cases.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba Serológica para COVID-19 , Humanos , Nasofaringe , Estudios Prospectivos , SARS-CoV-2/genética , Sensibilidad y Especificidad
8.
J Infect Chemother ; 28(6): 840-843, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35277343

RESUMEN

INTRODUCTION: Since respiratory sample collection is an uncomfortable experience, simultaneous detection of pathogens with a single swab is preferable. We prospectively evaluated the clinical performance of a newly developed antigen test QuickNavi-Flu+COVID19 Ag (Denka Co., Ltd., Tokyo, Japan) which can detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza viruses at the same time with a single testing device. METHODS: We included those who were suspected of contracting coronavirus disease 2019 (COVID-19) and were referred to a PCR center at Ibaraki prefecture in Japan, between August 2, 2021 to September 13, 2021, when the variant carrying L452R spike mutation of SARS-CoV-2 were prevalent. Additional nasopharyngeal samples and anterior nasal samples were obtained for the antigen test and were compared with a reference real-time reverse transcription PCR (RT-PCR) using nasopharyngeal samples. RESULTS: In total, 1510 nasopharyngeal samples and 862 anterior nasal samples were evaluated. During the study period, influenza viruses were not detected by QuickNavi-Flu+COVID19 Ag and reference real-time RT-PCR. For SARS-CoV-2 detection in nasopharyngeal samples, the sensitivity and specificity of the antigen test were 80.9% and 99.8%, respectively. The sensitivity and specificity using anterior nasal samples were 67.8% and 100%, respectively. In symptomatic cases, the sensitivities increased to 88.3% with nasopharyngeal samples and 73.7% with anterior nasal samples. There were three cases of discrepant results between the antigen test and the real-time RT-PCR. All of them were positive with the antigen test but negative with the real-time RT-PCR in SARS-CoV-2 detection. CONCLUSION: A combo kit, QuickNavi-Flu+COVID19 Ag, showed an acceptable sensitivity and sufficient specificity for SARS-CoV-2 detection, especially using nasopharyngeal sample collected from symptomatic patients.


Asunto(s)
COVID-19 , Antígenos Virales/análisis , COVID-19/diagnóstico , Prueba Serológica para COVID-19 , Humanos , Nasofaringe , SARS-CoV-2/genética , Sensibilidad y Especificidad
9.
J Infect Chemother ; 28(4): 543-547, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35016829

RESUMEN

INTRODUCTION: Smart Gene is a point-of-care (POC)-type automated molecular testing platform that can be performed with 1 min of hands-on-time. Smart Gene SARS-CoV-2 is a newly developed Smart Gene molecular assay for the detection of SARS-CoV-2. The analytical and clinical performance of Smart Gene SARS-CoV-2 has not been evaluated. METHODS: Nasopharyngeal and anterior nasal samples were prospectively collected from subjects referred to the local PCR center from March 25 to July 5, 2021. Two swabs were simultaneously obtained for the Smart Gene SARS-CoV-2 assay and the reference real-time RT-PCR assay, and the results of Smart Gene SARS-CoV-2 were compared to the reference real-time RT-PCR assay. RESULTS: Among a total of 1150 samples, 68 of 791 nasopharyngeal samples and 51 of 359 anterior nasal samples were positive for SARS-CoV-2 in the reference real-time RT-PCR assay. In the testing of nasopharyngeal samples, Smart Gene SARS-CoV-2 showed the total, positive and negative concordance of 99.2% (95% confidence interval [CI]: 98.4-99.7%), 94.1% (95% CI: 85.6-98.4%) and 99.7% (95% CI: 99.0-100%), respectively. For anterior nasal samples, Smart Gene SARS-CoV-2 showed the total, positive and negative concordance of 98.9% (95% CI: 97.2-99.7%), 98.0% (95% CI: 89.6-100%) and 99.0% (95% CI: 97.2-99.8%), respectively. In total, 5 samples were positive in the reference real-time RT-PCR assay and negative in the Smart Gene SARS-CoV-2 assay, whereas 5 samples were negative in the reference real-time RT-PCR assay and positive in the Smart Gene SARS-CoV-2 assay. CONCLUSION: Smart Gene SARS-CoV-2 showed sufficient analytical performance for the detection of SARS-CoV-2 in nasopharyngeal and anterior nasal samples.


Asunto(s)
COVID-19 , Ácidos Nucleicos , COVID-19/diagnóstico , Humanos , Nasofaringe , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , SARS-CoV-2/genética , Sensibilidad y Especificidad
10.
J Infect Chemother ; 28(1): 78-81, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34736814

RESUMEN

INTRODUCTION: Digital immunoassays are generally regarded as superior tests for the detection of infectious disease pathogens, but there have been insufficient data concerning SARS-CoV-2 immunoassays. METHODS: We prospectively evaluated a novel digital immunoassay (RapidTesta SARS-CoV-2). Two nasopharyngeal samples were simultaneously collected for antigen tests and Real-time RT-PCR. RESULTS: During the study period, 1127 nasopharyngeal samples (symptomatic patients: 802, asymptomatic patients: 325) were evaluated. For digital immunoassay antigen tests, the sensitivity was 78.3% (95% CI: 67.3%-87.1%) and the specificity was 97.6% (95% CI: 96.5%-98.5%). When technicians visually analyzed the antigen test results, the sensitivity was 71.6% (95% CI: 59.9%-81.5%) and the specificity was 99.2% (95% CI: 98.5%-99.7%). Among symptomatic patients, the sensitivity was 89.4% (95% CI; 76.9%-96.5%) with digital immunoassay antigen tests, and 85.1% (95% CI; 71.7%-93.8%) with visually analyzed the antigen test, respectively. CONCLUSIONS: The sensitivity of digital immunoassay antigen tests was superior to that of visually analyzed antigen tests, but the rate of false-positive results increased with the introduction of a digital immunoassay device.


Asunto(s)
COVID-19 , SARS-CoV-2 , Antígenos Virales , Humanos , Inmunoensayo , Sensibilidad y Especificidad
11.
J Infect Chemother ; 28(2): 248-251, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34799237

RESUMEN

INTRODUCTION: Antigen tests for severe acute respiratory coronavirus 2 sometimes show positive lines earlier than their specified read time, although the implication of getting the results at earlier time is not well understood. METHODS: We prospectively collected additional nasopharyngeal samples from patients who had already tested positive for SARS-CoV-2 by reverse transcription PCR. The swab was used for an antigen test, QuickNavi™-COVID19 Ag, and the time periods to get positive results were measured. RESULTS: In 84 of 96 (87.5%) analyzed cases, the results of QuickNavi™-COVID19 Ag were positive. The time to obtain positive results was 15.0 seconds in median (inter quartile range: 12.0-33.3, range 11-736) and was extended in samples with higher cycle thresholds (p < 0.001). Positive lines appeared within a minute in 85.7% of cases and within 5 min in 96.4%. CONCLUSION: QuickNavi™-COVID19 Ag immediately showed positive results in most cases, and the time to a positive reaction may have indicated the viral load.


Asunto(s)
COVID-19 , SARS-CoV-2 , Pruebas Diagnósticas de Rutina , Humanos , Nasofaringe , Sensibilidad y Especificidad
12.
PLoS One ; 16(12): e0262159, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34972195

RESUMEN

INTRODUCTION: GENECUBE® is a rapid molecular identification system, and previous studies demonstrated that GENECUBE® HQ SARS-CoV-2 showed excellent analytical performance for the detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) with nasopharyngeal samples. However, other respiratory samples have not been evaluated. METHODS: This prospective comparison between GENECUBE® HQ SARS-CoV-2 and reference real-time reverse transcriptase polymerase chain reaction (RT-PCR) was performed for the detection of SARS-CoV-2 using anterior nasal samples and saliva samples. Additionally, we evaluated a new rapid examination protocol using GENECUBE® HQ SARS-CoV-2 for the detection of SARS-CoV-2 with saliva samples. For the rapid protocol, in the preparation of saliva samples, purification and extraction processes were adjusted, and the total process time was shortened to approximately 35 minutes. RESULTS: For 359 anterior nasal samples, the total-, positive-, and negative concordance of the two assays was 99.7% (358/359), 98.1% (51/52), and 100% (307/307), respectively. For saliva samples, the total-, positive-, and negative concordance of the two assays was 99.6% (239/240), 100% (56/56), and 99.5% (183/184), respectively. With the new protocol, total-, positive-, and negative concordance of the two assays was 98.8% (237/240), 100% (56/56), and 98.4% (181/184), respectively. In all discordance cases, SARS-CoV-2 was detected by additional molecular examinations. CONCLUSION: GENECUBE® HQ SARS-CoV-2 provided high analytical performance for the detection of SARS-CoV-2 in anterior nasal samples and saliva samples.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Pruebas Diagnósticas de Rutina/métodos , Nasofaringe/virología , Pandemias , Saliva/virología , Humanos , Estudios Prospectivos
13.
J Infect Chemother ; 27(10): 1493-1497, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34294528

RESUMEN

INTRODUCTION: Rapid antigen tests are convenient for diagnosing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); however, they have lower sensitivities than nucleic acid amplification tests. In this study, we evaluated the diagnostic performance of Quick Chaser® Auto SARS-CoV-2, a novel digital immunochromatographic assay that is expected to have higher sensitivity than conventional antigen tests. METHODS: A prospective observational study was conducted between February 8 and March 24, 2021. We simultaneously obtained two nasopharyngeal samples, one for evaluation with the QuickChaser® Auto SARS-CoV-2 antigen test and the other for assessment with reverse transcription PCR (RT-PCR), considered the gold-standard reference test. The limit of detection (LOD) of the new antigen test was compared with those of four other commercially available rapid antigen tests. RESULTS: A total of 1401 samples were analyzed. SARS-CoV-2 was detected by reference RT-PCR in 83 (5.9%) samples, of which 36 (43.4%) were collected from symptomatic patients. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.7% (95% confidence interval (CI): 64.0-83.6%), 99.8% (95% CI: 99.5-100%), 96.9% (95% CI: 89.2-99.6%), and 98.4% (95% CI: 97.6-99.0%), respectively. When limited to samples with a cycle threshold (Ct) < 30 or those from symptomatic patients, the sensitivity increased to 98.3% and 88.9%, respectively. The QuickChaser® Auto SARS-CoV-2 detected 34-120 copies/test, which indicated greater sensitivity than the other rapid antigen tests. CONCLUSIONS: QuickChaser® Auto SARS-CoV-2 showed sufficient sensitivity and specificity in clinical samples of symptomatic patients. The sensitivity was comparable to RT-PCR in samples with Ct < 30.


Asunto(s)
COVID-19 , SARS-CoV-2 , Antígenos Virales , Humanos , Inmunoensayo , Sensibilidad y Especificidad , Plata
14.
J Infect Chemother ; 27(10): 1489-1492, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34301485

RESUMEN

INTRODUCTION: Antigen testing may help screen for and detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections in asymptomatic individuals. However, limited data regarding the diagnostic performance of antigen tests for this group are available. METHODS: We used clinical samples to prospectively evaluate the analytical and clinical performance of the antigen test QuickNavi™-COVID19 Ag. This study was conducted at a PCR center between October 7, 2020 and January 9, 2021. Two nasopharyngeal samples per patient were obtained with flocked swabs; one was used for the antigen test, and the other for real-time reverse transcription PCR (RT-PCR). The diagnostic performance of the antigen test was compared between asymptomatic and symptomatic patients, and the RT-PCR results were used as a reference. RESULTS: Among the 1934 collected samples, 188 (9.7%) demonstrated detection of SARS-CoV-2 by real-time RT-PCR; 76 (40.4%) of these 188 samples were from asymptomatic individuals, and over half of the total samples were asymptomatic (1073; 55.5%). The sensitivity of the antigen test was significantly lower for the asymptomatic group than for symptomatic patients (67.1% vs. 89.3%, respectively, p < 0.001). The specificity was 100% for both groups, and no false positives were observed among all 1934 samples. The median cycle threshold value for the asymptomatic group was significantly higher than that of the symptomatic group (24 vs. 20, p < 0.001). CONCLUSIONS: The QuickNavi™-COVID19 Ag showed lower sensitivity for the asymptomatic group than for symptomatic patients. However, its specificity was consistently high, and no false positives were found in this study.


Asunto(s)
Infecciones Asintomáticas , Prueba Serológica para COVID-19 , COVID-19 , Antígenos Virales , COVID-19/diagnóstico , Humanos , Estudios Prospectivos , SARS-CoV-2 , Sensibilidad y Especificidad
15.
Mol Diagn Ther ; 25(4): 495-504, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34003471

RESUMEN

BACKGROUND: Molecular tests are the mainstay of detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, their accessibility can be limited by the long examination time and inability to evaluate multiple samples at once. OBJECTIVE: This study evaluated the analytical performance of the newly developed rapid molecular assays GENECUBE® HQ SARS-CoV-2 and GENECUBE® FLU A/B. METHOD: This prospective study was conducted between 14 December 2020 and 9 January 2021 at a polymerase chain reaction (PCR) center. Samples were collected from the nasopharynx with flocked swabs. Molecular tests were performed with the GENECUBE® system and reference reverse transcription (RT)-PCR, and the results of the two assays were compared. RESULT: Among 1065 samples, 81 (7.6%) were positive for SARS-CoV-2 on the reference RT-PCR. Three showed discordance between GENECUBE® HQ SARS-CoV-2 and the reference RT-PCR; the total, positive, and negative samples of concordance for the two assays were 99.7%, 100%, and 99.7%, respectively. All discordant cases were positive with GENECUBE® HQ SARS-CoV-2 and negative with the reference RT-PCR. SARS-CoV-2 was detected in all three samples using another molecular assay for SARS-CoV-2. For GENECUBE® FLU A/B, the total, positive, and negative samples of concordance for the two assays were 99.5%, 100%, and 99.1%. CONCLUSION: The GENECUBE® HQ SARS-CoV-2 and GENECUBE® FLU A/B demonstrated sufficient analytical performance to detect SARS-CoV-2 and influenza virus A/B.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , SARS-CoV-2/genética , Benchmarking , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Humanos , Nasofaringe/virología , Estudios Prospectivos , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad
16.
Sci Rep ; 11(1): 10519, 2021 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-34006975

RESUMEN

The clinical utility of antigen test using anterior nasal samples has not been well evaluated. We conducted a prospective study in a drive-through testing site located at a PCR center to evaluate the diagnostic performance of the antigen test QuickNavi-COVID19 Ag using anterior nasal samples and to compare the degrees of coughs or sneezes induction and the severity of pain between anterior nasal collection and nasopharyngeal collection. The study included a total of 862 participants, of which 91.6% were symptomatic. The median duration from symptom onset to sample collection was 2.0 days. Fifty-one participants tested positive for severe acute respiratory syndrome coronavirus 2 on reverse transcription PCR (RT-PCR) with nasopharyngeal samples, and all of them were symptomatic. In comparison to the findings of RT-PCR, the antigen test using anterior nasal samples showed 72.5% sensitivity (95% confidence interval [CI] 58.3-84.1%) and 100% specificity (95% CI 99.3-100%). Anterior nasal collection was associated with a significantly lower degree of coughs or sneezes induction and the severity of pain in comparison to nasopharyngeal collection (p < 0.001). The antigen test using anterior nasal samples showed moderate sensitivity in symptomatic patients who were at the early stages of the disease course but was less painful and induced fewer coughs or sneezes.


Asunto(s)
Antígenos Virales/análisis , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Adolescente , Adulto , Anciano , COVID-19/patología , COVID-19/virología , Prueba Serológica para COVID-19 , Femenino , Humanos , Inmunoensayo , Masculino , Persona de Mediana Edad , Cavidad Nasal/virología , Nasofaringe/virología , Estudios Prospectivos , ARN Viral/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/genética , SARS-CoV-2/metabolismo , Índice de Severidad de la Enfermedad , Carga Viral , Adulto Joven
17.
J Infect Chemother ; 27(6): 890-894, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33727026

RESUMEN

INTRODUCTION: Several antigen tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed worldwide, but their clinical utility has not been well established. In this study, we evaluated the analytical and clinical performance of QuickNavi™-COVID19 Ag, a newly developed antigen test in Japan. METHODS: This prospective observational study was conducted at a PCR center between October 7 and December 5, 2020. The included patients were referred from a local public health center and 89 primary care facilities. We simultaneously obtained two nasopharyngeal samples with flocked swabs; one was used for the antigen test and the other for real-time reverse transcription PCR (RT-PCR). Using the results of real-time RT-PCR as a reference, the performance of the antigen test was evaluated. RESULTS: A total of 1186 patients were included in this study, and the real-time RT-PCR detected SARS-CoV-2 in 105 (8.9%). Of these 105 patients, 33 (31.4%) were asymptomatic. The antigen test provided a 98.8% (95% confidence interval [CI]: 98.0%-99.4%) concordance rate with real-time RT-PCR, along with a sensitivity of 86.7% (95% CI: 78.6%-92.5%) and a specificity of 100% (95% CI: 99.7%-100%). False-negatives were observed in 14 patients, 8 of whom were asymptomatic and had a low viral load (cycle threshold (Ct) > 30). In symptomatic patients, the sensitivity was 91.7% (95% CI: 82.7%-96.9%). CONCLUSION: QuickNavi™-COVID19 Ag showed high specificity and sufficient sensitivity for the detection of SARS-CoV-2. This test is a promising potential diagnostic modality especially in symptomatic patients.


Asunto(s)
Antígenos Virales/aislamiento & purificación , Prueba de COVID-19/métodos , COVID-19/diagnóstico , Adolescente , Adulto , Anciano , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , SARS-CoV-2 , Sensibilidad y Especificidad , Adulto Joven
18.
Sci Rep ; 11(1): 3033, 2021 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-33542335

RESUMEN

We investigated the efficiency of the Verigene Enteric Pathogens Nucleic Acid Test (Verigene EP test), which is an automated microarray-based assay system that enables rapid and simultaneous genetic detection of gastrointestinal pathogens and toxins, including those in the Campylobacter Group, Salmonella species, Shigella species, the Vibrio Group, Yersinia enterocolitica, Shiga toxin 1 and 2, norovirus GI/GII, and rotavirus A. Three clinical laboratories evaluated the Verigene EP test, using 268 stool samples for bacterial and toxin genes and 167 samples for viral genes. Culture-based reference methods were used for the detection of bacteria and toxins, while a different molecular assay was used for viral detection. The overall concordance rate between the Verigene EP test and the reference methods for the 1940 assays was 99.0%. The overall sensitivity and specificity of the Verigene EP test were 97.0% and 99.3%, respectively. Of the 19 samples with discordant results, 13 samples were false positives and six were false negatives. The Verigene EP test simultaneously detected two targets in 11 samples; overall, the test demonstrated high efficiency in detecting crucial diarrheagenic pathogens, indicating its suitability for clinical practice.


Asunto(s)
Toxinas Bacterianas/aislamiento & purificación , Diarrea/diagnóstico , Gastroenteritis/microbiología , Microbioma Gastrointestinal , Toxinas Bacterianas/genética , Diarrea/genética , Diarrea/microbiología , Heces/microbiología , Gastroenteritis/diagnóstico , Gastroenteritis/genética , Humanos , Técnicas de Diagnóstico Molecular , Norovirus/genética , Norovirus/aislamiento & purificación , Norovirus/patogenicidad , Técnicas de Amplificación de Ácido Nucleico/métodos , Toxina Shiga I/química , Toxina Shiga I/genética , Toxina Shiga I/aislamiento & purificación , Shigella/genética , Shigella/aislamiento & purificación , Shigella/patogenicidad
19.
J Med Microbiol ; 69(12): 1346-1350, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33141009

RESUMEN

Introduction. Resistance against macrolide antibiotics in Mycoplasma pneumoniae is becoming non-negligible in terms of both appropriate therapy and diagnostic stewardship. Molecular methods have attractive features for the identification of Mycoplasma pneumoniae as well as its resistance-associated mutations of 23S ribosomal RNA (rRNA).Hypothesis/Gap Statement. The automated molecular diagnostic sytem can identify macrolide-resistant M. pneumoniae.Aim. To assess the performance of an automated molecular diagnostic system, GENECUBE Mycoplasma, in the detection of macrolide resistance-associated mutations.Methodology. To evaluate whether the system can distinguish mutant from wild-type 23S rRNA, synthetic oligonucleotides mimicking known mutations (high-level macrolide resistance, mutation in positions 2063 and 2064; low-level macrolide resistance, mutation in position 2067) were assayed. To evaluate clinical oropharyngeal samples, purified nucleic acids were obtained from M. pneumoniae-positive samples by using the GENECUBE system from nine hospitals. After confirmation by re-evaluation of M. pneumoniae positivity, Sanger-based sequencing of 23S rRNA and mutant typing using GENECUBE Mycoplasma were performed.Results. The system reproducibly identified all synthetic oligonucleotides associated with high-level macrolide resistance. Detection errors were only observed for A2067G (in 2 of the 10 measurements). The point mutation in 23S rRNA was detected in 67 (26.9 %) of 249 confirmed M. pneumoniae-positive clinical samples. The mutations at positions 2063, 2064 and 2617 were observed in 65 (97.0 %), 2 (3.0 %) and 0 (0.0 %) of the 67 samples, respectively. The mutations at positions 2063 and 2064 were A2063G and A2064G, respectively. The results from mutant typing using GENECUBE Mycoplasma were in full agreement with the results from sequence-based typing.Conclusion. GENECUBE Mycoplasma is a reliable test for the identification of clinically significant macrolide-resistant M. pneumoniae.


Asunto(s)
Antibacterianos/farmacología , Farmacorresistencia Bacteriana , Macrólidos/farmacología , Técnicas de Diagnóstico Molecular/métodos , Mycoplasma pneumoniae/aislamiento & purificación , Neumonía por Mycoplasma/diagnóstico , Automatización , ADN Bacteriano , Humanos , Mutación , Mycoplasma pneumoniae/efectos de los fármacos , Mycoplasma pneumoniae/genética , Oligonucleótidos/síntesis química , Neumonía por Mycoplasma/microbiología , Reacción en Cadena de la Polimerasa/métodos , Análisis de Secuencia de ADN
20.
PLoS One ; 15(6): e0234119, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32492051

RESUMEN

Recently, a new rapid assay for the detection of tcdB gene of Clostridioides difficile was developed using the GENECUBE. The assay can directly detect the tcdB gene from stool samples without a purification in approximately 35 minutes with a few minutes of preparation process. We performed a prospective comparative study of the performance of the assay at eight institutions in Japan. Fresh residual stool samples (Bristol stool scale ≥5) were used and comparisons were performed with the BD MAX Cdiff assay and toxigenic cultures. For the evaluation of 383 stool samples compared with the BD MAX Cdiff assay, the sensitivity, and specificity of the two assays was 99.0% (379/383), 98.1% (52/53), 99.1% (327/330), respectively. In the comparison with toxigenic culture, the total, sensitivity, and specificity were 96.6% (370/383), 85.0% (51/60), and 98.8% (319/323), respectively. The current investigation indicated the GENECUBE Clostridioides difficile assay has equivalent performance with the BD MAX Cdiff assay for the detection of tcdB gene of C. difficile.


Asunto(s)
Proteínas Bacterianas/genética , Toxinas Bacterianas/genética , Clostridioides difficile/genética , Heces/microbiología , Clostridioides difficile/aislamiento & purificación , Infecciones por Clostridium/diagnóstico , ADN Bacteriano/genética , ADN Bacteriano/metabolismo , Enterotoxinas/genética , Humanos , Reacción en Cadena de la Polimerasa/métodos , Juego de Reactivos para Diagnóstico , Proteínas Represoras/genética , Sensibilidad y Especificidad