Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 14(17)2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39272746

RESUMEN

BACKGROUND: To determine if there is an association between semimembranosus tendinosis and medial meniscal tears using MRI. METHODS: A retrospective review of knee 3T MRI scans was performed to determine the presence or absence of medial meniscal tears in patients with semimembranosus tendinosis. All studies were interpreted by two musculoskeletal radiologists. Univariate association for the presence of semimembranosus tendinosis and medial meniscal tears was performed with a Chi-square test followed by logistic regression modelling among statistically significant associations. RESULTS: A total of 150 knee MRI scans were reviewed (age 32.8 ± 7.1 years; 70 females). Semimembranosus tendinosis was present in 66 knees (44%) in the patient population. Semimembranosus tendinosis was present in 81% of patients with meniscal tears versus 36% of patients without meniscal tears (p < 0.0001). This association remained statistically significant when adjusted for age and sex with an adjusted odds ratio of 7.0 (p < 0.0003). Models adjusted for the above covariates and containing the interaction term produced an adjusted odds ratio of 13.0 (p < 0.0001) in men, while in women this association was non-significant with an adjusted odds ratio of 2.0 (p = 0.42). CONCLUSIONS: Subjects with semimembranosus tendinosis were seven times more likely to have medial meniscal tears even when adjusting for sex and age. This could help guide the appropriate postmeniscal repair rehabilitation protocol.

2.
Pol J Radiol ; 89: e324-e327, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39139259

RESUMEN

Purpose: To determine the feasibility of meniscal imaging using virtual monochromatic images obtained through dualenergy computed tomography (DECT) technique, and to determine which keV levels optimise contrast resolution. Material and methods: All DECT exams were performed on a Discovery CT750 HD system from GE Healthcare. Virtual monochromatic images were reconstructed at 40 keV, 73 keV, 106 keV, and 139 keV. Contrast resolution of the medial and lateral menisci using a 5-point Likert scale at each keV level was determined through a consensus agreement by 2 fellowship-trained musculoskeletal radiologists. Friedman's and Wilcoxon signed rank tests were used to compare visualisation scores across different keV levels. Results: Seventeen knee exams from 10 patients met criteria for inclusion in the study. All patients included in the study cohort were male. The median age of patients was 46 years (interquartile range, 35-53 years). Virtual monochromatic images at 40 keV demonstrated highest contrast resolution of the menisci, with a statistically significant difference between contrast resolution scores at 40 keV and 76 keV, Friedman test: p < 0.0001. Conclusions: Meniscal imaging is feasible using DECT virtual monochromatic images at low keV levels. Improved contrast resolution at these specified KeV values could pave the way for further research in this field to determine its role in the future as an alternative option for assessment of the menisci in patients with contraindications to MRI or in the setting of a periarticular ferromagnetic foreign body obscuring the field of view.

3.
Acad Radiol ; 31(9): 3872-3878, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39013736

RESUMEN

RATIONALE AND OBJECTIVES: To determine the potential of large language models (LLMs) to be used as tools by radiology educators to create radiology board-style multiple choice questions (MCQs), answers, and rationales. METHODS: Two LLMs (Llama 2 and GPT-4) were used to develop 104 MCQs based on the American Board of Radiology exam blueprint. Two board-certified radiologists assessed each MCQ using a 10-point Likert scale across five criteria-clarity, relevance, suitability for a board exam based on level of difficulty, quality of distractors, and adequacy of rationale. For comparison, MCQs from prior American College of Radiology (ACR) Diagnostic Radiology In-Training (DXIT) exams were also assessed using these criteria, with radiologists blinded to the question source. RESULTS: Mean scores (±standard deviation) for clarity, relevance, suitability, quality of distractors, and adequacy of rationale were 8.7 (±1.4), 9.2 (±1.3), 9.0 (±1.2), 8.4 (±1.9), and 7.2 (±2.2), respectively, for Llama 2; 9.9 (±0.4), 9.9 (±0.5), 9.9 (±0.4), 9.8 (±0.5), and 9.9 (±0.3), respectively, for GPT-4; and 9.9 (±0.3), 9.9 (±0.2), 9.9 (±0.2), 9.9 (±0.4), and 9.8 (±0.6), respectively, for ACR DXIT items (p < 0.001 for Llama 2 vs. ACR DXIT across all criteria; no statistically significant difference for GPT-4 vs. ACR DXIT). The accuracy of model-generated answers was 69% for Llama 2 and 100% for GPT-4. CONCLUSION: A state-of-the art LLM such as GPT-4 may be used to develop radiology board-style MCQs and rationales to enhance exam preparation materials and expand exam banks, and may allow radiology educators to further use MCQs as teaching and learning tools.


Asunto(s)
Evaluación Educacional , Radiología , Radiología/educación , Humanos , Lenguaje , Consejos de Especialidades , Estados Unidos
4.
Sensors (Basel) ; 24(7)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38610578

RESUMEN

The aim of this paper is to investigate technological advancements made to a robotic tele-ultrasound system for musculoskeletal imaging, the MSK-TIM (Musculoskeletal Telerobotic Imaging Machine). The hardware was enhanced with a force feedback sensor and a new controller was introduced. Software improvements were developed which allowed the operator to access ultrasound functions such as focus, depth, gain, zoom, color, and power Doppler controls. The device was equipped with Wi-Fi network capability which allowed the master and slave stations to be positioned in different locations. A trial assessing the system to scan the wrist was conducted with twelve participants, for a total of twenty-four arms. Both the participants and radiologist reported their experience. The images obtained were determined to be of satisfactory quality for diagnosis. The system improvements resulted in a better user and patient experience for the radiologist and participants. Latency with the VPN configuration was similar to the WLAN in our experiments. This research explores several technologies in medical telerobotics and provides insight into how they should be used in future. This study provides evidence to support larger-scale trials of the MSK-TIM for musculoskeletal imaging.


Asunto(s)
Sistema Musculoesquelético , Robótica , Humanos , Ultrasonografía , Sistema Musculoesquelético/diagnóstico por imagen , Articulación de la Muñeca , Programas Informáticos
5.
Sensors (Basel) ; 23(20)2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37896531

RESUMEN

The development of teleoperated devices is a growing area of study since it can improve cost effectiveness, safety, and healthcare accessibility. However, due to the large distances involved in using teleoperated devices, these systems suffer from communication degradation, such as latency or signal loss. Understanding degradation is important to develop and improve the effectiveness of future systems. The objective of this research is to identify how a teleoperated system's behavior is affected by latency and to investigate possible methods to mitigate its effects. In this research, the end-effector position error of a 4-degree-of-freedom (4-DOF) teleultrasound robot was measured and correlated with measured time delay. The tests were conducted on a Wireless Local Area Network (WLAN) and a Virtual Local Area Network (VLAN) to monitor noticeable changes in position error with different network configurations. In this study, it was verified that the communication channel between master and slave stations was a significant source of delay. In addition, position error had a strong positive correlation with delay time. The WLAN configuration achieved an average of 300 ms of delay and a maximum displacement error of 7.8 mm. The VLAN configuration showed a noticeable improvement with a 40% decrease in average delay time and a 70% decrease in maximum displacement error. The contribution of this work includes quantifying the effects of delay on end-effector position error and the relative performance between different network configurations.

6.
J Wrist Surg ; 12(3): 225-231, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37223382

RESUMEN

Background Four-corner arthrodesis (4CA) can be performed with a variety of methods. To our knowledge, fewer than 125 cases of 4CA with a locking polyether ether ketone (PEEK) plate have been reported, necessitating further study. Purpose The purpose of this study was to evaluate the radiographic union rate and clinical outcomes in a series of patients who received 4CA with a locking PEEK plate. Methods We re-examined 39 wrists in 37 patients at a mean follow-up of 50 months (median: 52 months, range: 6-128). Patients completed the Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH), Patient-Rated Wrist Evaluation (PRWE), and participated in measurements of grip strength and range of motion. Anteroposterior, lateral, and oblique radiographs of the operative wrist were examined for union, screw breakage and/or loosening, and lunate change. Results The mean QuickDASH score was 24.4 and the mean PRWE score was 26.5. Mean grip strength was 29.2 kg or 84% of the nonoperative hand. Mean flexion, extension, radial deviation, and ulnar deviation were : 37.2, 28.9, 14.1, and 17.4 degrees, respectively. Eighty-seven percent of wrists achieved union; 8% had nonunion; and5% had indeterminate union. There were seven cases of screw breakage and seven cases of screw loosening (as defined by lucency or bony resorption surrounding screws). Twenty-three percent of wrists required reoperation (four total wrist arthrodesis and five reoperations for other reasons). Conclusion 4CA with a locking PEEK plate has clinical and radiographic outcomes similar to other methods. We observed a high rate of hardware complications. It is unclear whether this implant offers a clear advantage over other methods of fixation used in 4CA. Type of Study/Level of Evidence Level IV, therapeutic study.

7.
Pediatr Radiol ; 53(5): 971-983, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36627376

RESUMEN

Morquio syndrome, also known as Morquio-Brailsford syndrome or mucopolysaccharidosis type IV (MPS IV), is a subgroup of mucopolysaccharidosis. It is an autosomal recessive lysosomal storage disorder. Two subtypes of Morquio syndrome have been identified. In MPS IVA, a deficiency in N-acetylgalactosamine-6-sulfate sulfatase interrupts the normal metabolic pathway of degrading glycosaminoglycans. Accumulated undigested glycosaminoglycans in the tissue and bones result in complications leading to severe skeletal deformity. In MPS IVB, a deficiency in beta-galactosidase results in a milder phenotype than in MPS IVA. Morquio syndrome presents a variety of clinical manifestations in a spectrum of mild to severe. It classically has been considered a skeletal dysplasia with significant skeletal involvement. However, the extraskeletal features can also provide valuable information to guide further work-up to assess the possibility of the disorder. Although the disease involves almost all parts of the body, it most commonly affects the axial skeleton, specifically the vertebrae. The characteristic radiologic findings in MPS IV, such as paddle-shaped ribs, odontoid hypoplasia, vertebral deformity, metaphyseal and epiphyseal bone dysplasia, and steep acetabula, are encompassed in the term "dysostosis multiplex," which is a common feature among other types of MPS and storage disorders. Myelopathy due to spinal cord compression and respiratory airway obstruction are the most critical complications related to mortality and morbidity. The variety of clinical features, as well as overlapping of radiological findings with other disorders, make diagnosis challenging, and delays in diagnosis and treatment may lead to critical complications. Timely imaging and radiologic expertise are important components for diagnosis. Gene therapies may provide robust treatment, particularly if genetic variations can be screened in utero.


Asunto(s)
Mucopolisacaridosis IV , Osteocondrodisplasias , Humanos , Mucopolisacaridosis IV/diagnóstico por imagen , Mucopolisacaridosis IV/tratamiento farmacológico , Glicosaminoglicanos/metabolismo , Glicosaminoglicanos/uso terapéutico , Columna Vertebral , Huesos
8.
J Ultrasound Med ; 42(1): 109-123, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35906950

RESUMEN

INTRODUCTION: Telerobotic ultrasound technology allows radiologists and sonographers to remotely provide ultrasound services in underserved areas. This study aimed to compare costs associated with using telerobotic ultrasound to provide ultrasound services in rural and remote communities to costs associated with alternate models. METHODS: A cost-minimization approach was used to compare four ultrasound service delivery models: telerobotic ultrasound (Model 1), telerobotic ultrasound and an itinerant sonographer (Model 2), itinerant sonographer without telerobotic ultrasound (Model 3), and travel to another community for all exams (Model 4). In Models 1-3, travel was assumed when exams could not be successfully performed telerobotically or by an itinerant sonographer. A publicly funded healthcare payer perspective was used for the reference case and a societal perspective was used for a secondary non-reference case. Costs were based on the literature and experience using telerobotic ultrasound in Saskatchewan, Canada. Costs were expressed in 2020 Canadian dollars. RESULTS: Average cost per ultrasound exam was $342, $323, $368, and $478 for Models 1, 2, 3, and 4, respectively, from a publicly funded healthcare payer perspective, and $461, $355, $447, and $849, respectively, from a societal perspective. In one-way sensitivity analyses, Model 2 was the lowest cost from a payer perspective for communities with population >2075 people, distance >350 km from the nearest ultrasound facility, or >47% of the population eligible for publicly funded medical transportation. CONCLUSION: Health systems may wish to consider solutions such as telerobotic ultrasound and itinerant sonographers to reduce healthcare costs and improve access to ultrasound in rural and remote communities.


Asunto(s)
Robótica , Humanos , Análisis Costo-Beneficio , Canadá , Ultrasonografía , Población Rural
9.
JSES Int ; 6(5): 809-814, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36081706

RESUMEN

Background: The biomechanical role of the proximal long head of the biceps tendon (PLHB) in glenohumeral joint stability remains controversial. This retrospective study aims to correlate between humeral head migration and PLHB pathology in patients with and without rotator cuff tendon tears using imaging. Methods: Seventy-nine patients who underwent 3T magnetic resonance imaging of the shoulder were retrospectively reviewed. Imaging findings were documented by a fellowship-trained musculoskeletal radiologist. PLHB tendon diameter change, contour irregularity, and signal intensity change were assessed. Rotator cuff status was given a binary assignment of intact vs. torn. Radiographs were used for measurement of the acromiohumeral distance and a cutoff value of 7 mm was set as a lower limit of normal. Results: In the cohort of 79 shoulders, 41.8% (33/79) of patients had intact PLHB tendon and rotator cuff, 26.6% (21/79) demonstrated isolated PLHB tendon pathology, 13.9% (11/79) demonstrated isolated rotator cuff tears, and 17.7% (14/79) demonstrated concomitant PLHB tendon pathology and rotator cuff tears. Acromiohumeral distance was preserved in 97.0% (32/33) of patients with intact PLHB tendon and rotator cuff, 28.6% (6/21) of patients with isolated PLHB tendon pathology, 81.8% (9/11) of patients with isolated rotator cuff tears, and 14.3% (2/14) of patients with concomitant PLHB tendon pathology and rotator cuff tears (P < .0001). Conclusion: Results of this study have shown that a statistical correlation was present between superior humeral head migration and PLHB tendon pathology with or without rotator cuff tears, compared to rotator cuff pathology alone. Findings suggest that intact PLHB tendon plays an important role in glenohumeral stability.

10.
J Clin Rheumatol ; 28(8): 402-408, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-35981296

RESUMEN

OBJECTIVE: The aim of this study was to explore association between hypermobility and osteoarthritis (OA) at the first carpometacarpal (CMC) joint, using magnetic resonance imaging (MRI) to identify early change in women at high risk of developing OA but without yet established diagnoses. METHODS: For this observational study, 33 women (aged 30-50 years) with self-reported history of maternal hand OA but without personal diagnoses of OA were recruited. Participants completed a 5-point hypermobility questionnaire. The 20 participants with 2 or more positive responses were categorized with "high hypermobility scores." The remaining 13 were categorized with "low hypermobility scores." Data collection included functional index, hand pain measure, parity, smoking status, and body mass index. Each participant underwent dominant hand radiographic and MRI examination. Imaging studies were interpreted by assessors blinded to hypermobility score categorization. RESULTS: No significant differences in age, body mass index, parity, functional index, or pain scores were observed between higher and lower hypermobility score groups. Similarly, there were no significant differences between groups for radiographic changes. However, significantly higher proportions of women with higher hypermobility scores were observed on MRI to have abnormalities of trapezium cartilage (75% vs. 38%), metacarpal cartilage (80% vs. 38%), and trapezium bone (70% vs. 31%); p < 0.05 for all. CONCLUSIONS: First CMC joint structural abnormalities were more frequently observed in women with higher hypermobility scores. Identification of early preradiographic changes in this group supports the concept that early-life joint laxity may contribute to future OA predisposition. Magnetic resonance imaging may be a preferred imaging test for detection of early cartilage changes in people at high risk of CMC joint OA.


Asunto(s)
Articulaciones Carpometacarpianas , Inestabilidad de la Articulación , Osteoartritis , Humanos , Femenino , Articulaciones Carpometacarpianas/patología , Osteoartritis/diagnóstico por imagen , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/etiología , Imagen por Resonancia Magnética , Dolor
11.
Skeletal Radiol ; 51(10): 2009-2016, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35437644

RESUMEN

OBJECTIVE: To validate MRI for the quantification of the femoral neck version (FNV) using posterior lesser trochanteric Line (PLTL) and to compare reliability of the PLTL to the epicondylar and retrocondylar measurements. MATERIALS AND METHODS: A retrospective review of 3 T MRI scans performed for femoroacetabular impingement (FAI). Two musculoskeletal radiologists performed the measurements. MRI measurements of the PLTL were compared to CT using Bland Altman, Lin's concordance, and Lin's correlation coefficients. Interobserver reliability was determined using Bland Altman, Lin's concordance, and Lin's correlation coefficients. Intraobserver reliability was determined using Lin's concordance and Lin's correlation coefficients. RESULTS: Forty-five patients (90 lower extremities) met the inclusion criteria. Ages ranged from 20 to 41 years, with a mean of 31.5 years. There were 22 females and 23 males. Lin's concordance correlation coefficient for MRI and CT measurements of PLTL was substantial: 0.96 (95% CI: 0.94-0.98). PLTL Lin's correlation coefficient was 0.825 (95% CI 0.732-0.918) and indicated good interobserver reliability. Epicondylar and retrocondylar methods Lin's correlation coefficients demonstrated moderate interobserver reliability at 0.601 (0.415-0.786) and 0.632 (0.456-0.807), respectively. There was moderate 95% confidence interval overlap between the PLTL and the other measurements. Bland-Altman plots for each measurement were similar and demonstrated no bias. There was excellent intraobserver reliability (> 0.900) with significant 95% confidence interval overlap. CONCLUSION: MRI measurements of the PLTL are comparable to CT. The PLTL has good reliability between readers for the quantification of FNV using MRI, which could help avoid unnecessary radiation exposure using CT and reduce MRI scan time.


Asunto(s)
Pinzamiento Femoroacetabular , Cuello Femoral , Adulto , Femenino , Pinzamiento Femoroacetabular/diagnóstico por imagen , Fémur , Cuello Femoral/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados , Adulto Joven
12.
Skeletal Radiol ; 51(9): 1837-1841, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35312029

RESUMEN

OBJECTIVE: To describe MRI changes of the coracoclavicular bursa in patients presenting with shoulder pain and examine whether there is an association with coracoclavicular distance measurements. METHODS: Retrospective analysis of 198 shoulder 3T MRI scans for patients with shoulder pain was performed. Two musculoskeletal trained radiologists read all MRI scans. Inter-reader and intra-reader agreements for the bursal changes were assessed using the Kappa coefficient. The coracoclavicular distance was stratified into three intervals: < 5 mm, 5-10 mm, and > 10 mm. Statistical analysis for the coracoclavicular bursal changes and coracoclavicular distance was conducted using Fisher's exact test. RESULTS: Coracoclavicular bursal changes were detected in 9% (n = 18/198) of patients. There was a statistically significant association between coracoclavicular distance (< 5 mm) and the presence of coracoclavicular bursal changes (p-value = 0.011). All patients (100%, n = 18/18) with coracoclavicular bursal fluid presented with shoulder pain with 44.5% of the patients (n = 8/18) describing anterior shoulder pain. A statistically significant association was detected between coracoclavicular bursal changes and anterior shoulder pain (p-value = 0.0011). Kappa coefficient for the bursal changes inter-reader agreement was moderate (0.67) and the intra-reader agreement was almost perfect (0.91). CONCLUSION: Coracoclavicular bursal changes were detected in 9% of shoulder MRI scans and were associated with reduced coracoclavicular distance (< 5 mm) suggesting an underlying mechanical disorder such as a friction or an impingement process. Documenting coracoclavicular bursal changes in the MRI report could help address patients' concerns and guide further management particularly in the context of shoulder pain and coracoclavicular distance of less than 5 mm.


Asunto(s)
Articulación del Hombro , Dolor de Hombro , Bolsa Sinovial , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos , Dolor de Hombro/diagnóstico por imagen
13.
Singapore Med J ; 63(2): 97-104, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-32798361

RESUMEN

INTRODUCTION: Shortening of the tendon and muscle is recognised as a strong predictor of surgical failure of supraspinatus tendon tears. Changes in muscle architecture following repair have not been thoroughly investigated. Hence, we aimed to compare the pre- and postoperative architecture of the supraspinatus. METHODS: We recruited eight participants with full-thickness supraspinatus tears. Images of the supraspinatus were captured preoperatively (pre-op) and postoperatively at one month (post-op1), three months (post-op2) and six months (post-op3) in relaxed and contracted states (0º and 60º glenohumeral abduction). Fibre bundle length (FBL), pennation angle (PA) and muscle thickness were quantified. Self-reported function, and maximal isometric abduction and external rotation strengths were assessed. RESULTS: The mean FBL increased from pre-op to post-op1 (p = 0.001) in the relaxed state and from pre-op to post-op2 (p = 0.002) in the contracted state. Decrease in FBL was observed from post-op2 to post-op3 in the relaxed state. The mean PA decreased from pre-op to post-op1 (p < 0.001) in the relaxed state, but increased from post-op2 to post-op3 in both relaxed (p = 0.006) and contracted (p = 0.004) states. At post-op3, external rotation (p = 0.009) and abduction (p = 0.005) strengths were greater than at post-op2. Overall function increased by 47.67% from pre-op to post-op3. CONCLUSION: Lengthening of the supraspinatus occurs with surgery, altering the length-tension relationship of the muscle, which can compromise muscle function and lead to inferior surgical outcomes. These findings may guide clinicians to optimise loads, velocities and shoulder ranges for effective postoperative rehabilitation.


Asunto(s)
Lesiones del Manguito de los Rotadores , Articulación del Hombro , Humanos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Tendones
14.
BMC Res Notes ; 14(1): 393, 2021 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-34689794

RESUMEN

OBJECTIVE: To develop a collision engine (haptic force feedback simulator) compatible with a 5-degrees-of-freedom (DOF) haptic wand. This has broad applications such as telerobotic ultrasound systems. Integrating force feedback into systems is critical to optimize remote scanning. A collision engine compatible with a 5-DOF haptic wand was developed based on the Gilbert-Johnson-Keerthi algorithm. The collision engine calculated force during collision between the wand and a virtual object based on code developed using MATLAB. A proportional force was subsequently returned to a user via the haptic wand, thereby simulating the collision force for the user. Three experiments were conducted to assess the accuracy of the collision engine on curved and flat surfaces. RESULTS: The average errors in calculation of distances between the wand and virtual object were 2.1 cm, 3.4 cm, and 4.2 cm for the model of the human hand, cylinder, and cuboid, respectively. The collision engine accurately simulated forces on a flat surface, though was less accurate on curved surfaces. Future work will incorporate haptic force feedback into a telerobotic ultrasound system. The haptic force simulator presented here may also be used in the development of ultrasound simulators for training and education.


Asunto(s)
Robótica , Algoritmos , Simulación por Computador , Retroalimentación , Mano , Humanos , Tacto , Interfaz Usuario-Computador
15.
Eur Radiol Exp ; 5(1): 29, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-34312733

RESUMEN

BACKGROUND: Telesonography systems have been developed to overcome barriers to accessing diagnostic ultrasound for patients in rural and remote communities. However, most previous telesonography systems have been designed for performing only abdominal and obstetrical exams. In this paper, we describe the development and assessment of a musculoskeletal (MSK) telesonography system. METHODS: We developed a 4-degrees-of-freedom (DOF) robot to manipulate an ultrasound probe. The robot was remotely controlled by a radiologist operating a joystick at the master site. The telesonography system was used to scan participants' forearms, and all participants were conventionally scanned for comparison. Participants and radiologists were surveyed regarding their experience. Images from both scanning methods were independently assessed by an MSK radiologist. RESULTS: All ten ultrasound exams were successfully performed using our developed MSK telesonography system, with no significant delay in movement. The duration (mean ± standard deviation) of telerobotic and conventional exams was 4.6 ± 0.9 and 1.4 ± 0.5 min, respectively (p = 0.039). An MSK radiologist rated quality of real-time ultrasound images transmitted over an internet connection as "very good" for all telesonography exams, and participants rated communication with the radiologist as "very good" or "good" for all exams. Visualisation of anatomic structures was similar between telerobotic and conventional methods, with no statistically significant differences. CONCLUSIONS: The MSK telesonography system developed in this study is feasible for performing soft tissue ultrasound exams. The advancement of this system may allow MSK ultrasound exams to be performed over long distances, increasing access to ultrasound for patients in rural and remote communities.


Asunto(s)
Abdomen , Robótica , Abdomen/diagnóstico por imagen , Humanos , Ultrasonografía
16.
Knee ; 29: 262-270, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33676321

RESUMEN

BACKGROUND: Bone-cartilage mismatch is a variation in which the surface curvature of the articular cartilage is incongruent with the curvature of the underlying subchondral bone. The purpose of this study is to investigate the prevalence of this variant in the medial tibial plateau (MTP) and examine potential association with clinical findings and intra-articular derangements using MRI. METHODS: A quantitative and qualitative retrospective analysis of 98 knee MRI studies was performed. Bone and cartilage depths of the MTP were measured to assess bone-cartilage morphology and classified into congruent (concave bone-concave cartilage) and incongruent (concave bone-convex cartilage) patterns. Associations between bone-cartilage mismatch and clinical findings and other MRI changes were assessed using Fisher's exact test. RESULTS: By quantitative assessment, four individuals (4%) had MTP incongruent morphology (bone-cartilage mismatch). The mean bone depth ± standard deviation (SD) was 2.3 ± 0.6 mm concave in the congruent group, and 1.4 ± 0.6 mm concave in the incongruent group. The mean cartilage depth ± SD was 0.7 ± 0.7 mm concave in the congruent group, and 0.9 ± 0.5 mm convex in the incongruent group. By qualitative assessment, three individuals (3%) had incongruent morphology. Although not statistically significant, a higher proportion of individuals (3 of 4; 75%) with incongruent cartilage demonstrated chondromalacia patellae compared to those with congruent cartilage (38 of 94; 40%). CONCLUSION: Bone-cartilage mismatch was present in 3-4% of the knees. Individuals with incongruent cartilage demonstrated a trend of a higher proportion of chondromalacia patellae. Larger studies are needed to evaluate this further.


Asunto(s)
Cartílago Articular/diagnóstico por imagen , Imagen por Resonancia Magnética , Tibia/diagnóstico por imagen , Adulto , Artralgia/etiología , Condromalacia de la Rótula/etiología , Femenino , Humanos , Inestabilidad de la Articulación/etiología , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Estudios Retrospectivos
17.
Skeletal Radiol ; 50(8): 1567-1573, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33410966

RESUMEN

OBJECTIVE: Femoral epiphyseal spurs are developmental projections that form at the edge of the physis. Although considered incidental, their association with acetabular labral tears has never been examined. Our aim was to assess the prevalence of femoral epiphyseal spurs in symptomatic patients with mechanical hip pain and explore if they are associated with labral tears on MRI. MATERIALS AND METHODS: Hip MRI scans performed on a Siemens 3 T MRI using femoroacetabular impingement protocol were retrospectively reviewed. All patients were referred by orthopaedic surgeons for mechanical hip pain. Two musculoskeletal radiologists blinded to initial reports evaluated MRI images for the presence of an epiphyseal spur and acetabular labral changes. A consensus was achieved on all cases by the two readers. The association between epiphyseal spurs and labral changes was assessed using Fisher's exact test. RESULTS: A total of 115 patients (178 hip MRI scans) were reviewed; the mean age was 28.8 years (SD 7.1). There were 52 females (45.2%) and 63 males (54.8%). There were 115 hips with labral tears (64.6%). Fourteen hips (7.8%) in ten patients (8.7%) demonstrated epiphyseal spurs and all of them showed labral tears (100%). There was statistically significant association between epiphyseal spurs and labral tears on MRI (p value = 0.0024). CONCLUSION: Femoral epiphyseal spurs were observed in 8.7% of our defined patient population, and all patients with epiphyseal spurs demonstrated labral tears. Epiphyseal spurs should be documented on imaging reports due to their potential association with labral tears. Future research is needed to further delineate and guide management of these entities.


Asunto(s)
Cartílago Articular , Pinzamiento Femoroacetabular , Acetábulo/diagnóstico por imagen , Adulto , Artroscopía , Femenino , Pinzamiento Femoroacetabular/diagnóstico por imagen , Articulación de la Cadera , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Retrospectivos
18.
J Knee Surg ; 34(13): 1441-1445, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32403150

RESUMEN

Predicting postoperative outcomes following total knee arthroplasty (TKA) is important for patient selection. This study focuses on patient-reported outcomes and satisfaction in relation to preoperative radiographic arthritis severity. A retrospective chart review of 420 TKAs was performed. Patient satisfaction was determined using a structured telephone survey with questions focused on degree of satisfaction whether they would have surgery again and their ability to kneel. The radiographic severity of the arthritis of the tibiofemoral joint was graded by a musculoskeletal radiologist using the Kellgren-Lawrence grading scale. The patellofemoral compartment was graded using the scale described by Jones et al. Those grouped as severe arthritis had an overall satisfaction rate of 96% (76% fully satisfied and 20% partially satisfied) compared with 82% of the time (64% fully satisfied and 18% partially satisfied) if their arthritis was mild. Postoperatively 51% of TKA patients were able to kneel. Univariate logistic regression showed an association between higher rates of satisfaction and male gender (p = 0.053), severity of preoperative radiographic arthritis (p = 0.034) those who would have surgery again (p ≤ 0.0001) and those able to kneel (p = 0.005). Patients should be informed preoperatively that if their arthritis is only mild radiographically, their outcomes are less predictable. There should also be a discussion surrounding kneeling and activities patients do, which may require kneeling, as many are unable to kneel postoperatively. The Level of Evidence for the study is III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Masculino , Osteoartritis de la Rodilla/cirugía , Satisfacción del Paciente , Estudios Retrospectivos , Resultado del Tratamiento
19.
J Ultrasound Med ; 40(7): 1287-1306, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33058242

RESUMEN

Access to sonographers and sonologists is limited in many communities around the world. Telerobotic sonography (robotic ultrasound) is a new technology to increase access to sonography, providing sonographers and sonologists the ability to manipulate an ultrasound probe from a distant location and remotely perform ultrasound examinations. This narrative review discusses the development of telerobotic ultrasound systems, clinical studies evaluating the feasibility and diagnostic accuracy of telerobotic sonography, and emerging use of telerobotic sonography in clinical settings. Telerobotic sonography provides an opportunity to provide real-time ultrasound examinations to underserviced rural and remote communities to increase equity in the delivery of diagnostic imaging.


Asunto(s)
Robótica , Humanos , Ultrasonografía
20.
Ultrasound J ; 12(1): 40, 2020 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-32880025

RESUMEN

BACKGROUND: Primary care physicians frequently encounter patients with supraspinatus pathology and face a difficult task of managing this subset of patients using limited imaging resources. The purpose of this study was to develop a guidance that could help primary care physicians choose appropriate imaging tests judiciously for patients with suspected supraspinatus pathology. METHODS: The imaging reports of one hundred patients who underwent ultrasound and MRI for suspected supraspinatus tendinopathy were retrospectively assessed. The supraspinatus tendon was recorded as intact, partial tear (articular or bursal), or full-thickness tear (focal or complete width). The agreement between imaging modalities was then evaluated using factors such as pathology type and age. RESULTS: There was agreement between modalities in 48/100 patients (Kappa statistic = 0.30). The consistency varied with type of pathology: intact tendons by ultrasound had 55.8% agreement with MRI, partial sided bursal tears 50%, partial sided articular tears 25%, and full-thickness focal tears 33.3%. Full-thickness complete-width tears had a much better agreement with MRI at 90.9%. Age was also significant, with increased disagreement between ultrasound and MRI in patients over 50 years old. CONCLUSIONS: Our data showed that ultrasound findings correlated well with MRI in patients under 50 years of age and also in patients with full-thickness supraspinatus tears. We recommend that primary care physicians may consider using ultrasound as the initial test in younger patients and in patients with suspected full supraspinatus tears, based on clinical exam, with MRI as an option for further evaluation to quantify supraspinatus muscle atrophy. These patient selection recommendations will help promote mindful utilization of scarce resources.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA