RESUMEN
Although athletic participation lowers cardiovascular risk and improves quality of life, it may represent a hazard in high-risk group athletes such as those with cardiac abnormalities receiving an implantable cardioverter defibrillator (ICD). ICD sports participants are exposed to the potential risk of inappropriate shocks due to sinus tachycardia and other supraventricular arrhythmias during exertion as well as device injury. The safety of athletic participation of ICD-patients is not completely defined and ICD efficacy in interrupting malignant arrhythmias during intense exercise is partly unknown. This explains difficulties in current recommendations made by physicians, given the associated potentially ischemic, autonomic and metabolic conditions. The scope of this review is to underline specific considerations including potential risks and recommendations for athletic participation in this patient-group.
Asunto(s)
Desfibriladores Implantables , Ejercicio Físico , Deportes , Muerte Súbita Cardíaca/prevención & control , Falla de Equipo , Humanos , Sistema de Registros , Factores de Riesgo , Programas InformáticosRESUMEN
Spontaneous behavior of ventricular extrasystoles (VE) was analysed. From a database containing 578 athletes with VE, 84 males and 11 females (29.9 ± 18.1 years) having ≥ 100 VE or repetitive VE [ventricular couplets (VC) or ventricular tachycardias (VT)] at first 24-hour Holter electrocardiographic monitoring (24-h-HM) (baseline) and at least 1-year of follow-up (3.1 ± 2.2 years) over the past 10 years were selected. The baseline was compared with the last 24-h-HM to establish DVE (VE reduction of at least 98%/24 h in the absence of VC or VT). SDVE was calculated as standard deviation of the number of VE on serial 24-h-HMs. DVE and SDVE were considered as dependent variables. Independent variables were: age, sex, type of sport, symptoms, baseline VE rate (BVE), baseline VC and VT, VE morphology, VE behavior during the baseline training session, disqualification from competitive sports, echocardiographic abnormalities. DVE occurred in 32 athletes (34%). SDVE varied from 0 to 12,658 VE/24 h (1916 ± 2649.9). Disappearance of VE during the baseline training session (DVET) correlated to DVE (P = 0.0319). BVE directly correlated to SDVE (P = 0.0008). Athletes' VE are highly variable over time, their variability depending on BVE, and they not infrequently tend to disappear. The only useful variable for predicting DVE is DVET.
Asunto(s)
Acondicionamiento Físico Humano/fisiología , Deportes/fisiología , Taquicardia Ventricular/fisiopatología , Complejos Prematuros Ventriculares/fisiopatología , Adolescente , Adulto , Niño , Ecocardiografía , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Adulto JovenRESUMEN
Many studies have shown a relationship between long-term endurance sport practice and atrial fibrillation. Inflammation, anatomic remodelling, alterations in the autonomic system and neurohormonal activation are all possible explanations for the increased prevalence of this arrhythmia in athletes. Atrial fibrillation may determine disabling symptoms like palpitations and impaired physical performance, compromising eligibility for competitive activities, but exclusion from sport is not necessary for all athletes. Limited data are available on drug therapy and recently ablation resulted to be a particularly attractive option for young athletes with paroxysmal atrial fibrillation. The purpose of this review is to discuss mechanisms, clinical features, management of atrial fibrillation in competitive athletes, including criteria for eligibility and disqualification in sport practice.
Asunto(s)
Atletas , Fibrilación Atrial/etiología , Resistencia Física/fisiología , Deportes/fisiología , Rendimiento Atlético , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Humanos , Calidad de Vida , Factores de RiesgoRESUMEN
AIMS: Little is known about the incidence of paroxysmal atrial tachycardias (PAT) in patients with heart failure (HF). The availability of cardiac resynchronization therapy (CRT) devices with extended diagnostics for AT enables continuous monitoring of PAT episodes. The aim of the study was to assess the incidence over time of PAT in HF patients treated with CRT. METHODS AND RESULTS: Consecutive patients in NYHA functional class III or IV despite optimal drug therapy, QRS duration > or = 130 ms, left ventricular ejection fraction < or = 35%, and left ventricular end-diastolic dimension > or = 55 mm were eligible for enrolment. Patients with permanent or persistent atrial fibrillation (AF) were not included in the study. The first follow-up examination was performed 2 weeks after implantation, to optimize atrial sensing and CRT. Subsequent follow-up examinations were carried out 15 and 28 weeks after implantation, to collect the telemetric data. A total of 173 patients (67 +/- 11 years, M 116) were enrolled. Complete arrhythmia monitoring data were available from 120 patients over a mean follow-up of 183 +/- 23 days. Atrial tachycardia episodes were detected through telemetry in 25 of 120 patients (21%) during at least one follow-up examination. Atrial tachycardia episodes were recorded in 29 and 17% (P = NS) of patients with and without previous history of AF, respectively. CONCLUSION: More than 20% of the overall HF patient population treated with CRT suffer PAT episodes. Paroxysmal atrial tachycardia may interfere with response to CRT. Therefore, telemetric data may be relevant to drive the appropriate therapy in each patient.
Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/prevención & control , Estimulación Cardíaca Artificial/estadística & datos numéricos , Electrocardiografía Ambulatoria/estadística & datos numéricos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Anciano , Fibrilación Atrial/diagnóstico , Comorbilidad , Europa (Continente)/epidemiología , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Incidencia , Masculino , Medición de Riesgo/métodos , Factores de Riesgo , Resultado del TratamientoRESUMEN
The aim of this article is to report the evidences about the use of drugs and ablation after implantation of a cardioverter defibrillator. Drugs can be utilized to prevent appropriate and inappropriate shocks, can influence positively or negatively defibrillation threshold, can be useful for the treatment of electrical storm. Ablation can be performed for direct cure of coexisting atrial and ventricular tachyarrhythmias or for AV node modulation. In particular, previous data demonstrate that rescue ventricular tachycardia ablation of drug-refractory electrical storm is possible by a substrate-orientated ablation approach even in patients with complex chronic infarction and various ventricular tachycardias. At the end of this article it is described how remote monitoring, a new very promising technical improvement, can be utilized for deciding, almost in real time, the use of both these therapies or for controlling their efficacy.
Asunto(s)
Antiarrítmicos/uso terapéutico , Arritmias Cardíacas/terapia , Ablación por Catéter , Desfibriladores Implantables , Arritmias Cardíacas/tratamiento farmacológico , Arritmias Cardíacas/cirugía , Fibrilación Atrial/terapia , Humanos , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Fibrilación Ventricular/terapiaRESUMEN
Implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) have been introduced during the recent years to improve survival, decrease hospital readmissions and mortality, and to improve functional status and quality of life for patients with heart failure and left ventricular systolic dysfunction (LVSD). Studies which evaluated the use of CRT or ICD alone or compared CRT with CRT-ICD in patients with heart failure and LVSD are listed in this article. The results obtained are already influencing clinical practice in the US, where it has been estimated that 90% of patients receiving a CRT device now are being implanted with an ICD component. However, it is still today debated whether patients with LVSD and heart failure should be routinely offered a CRT-ICD. In fact, there are some issues that still should be solved before to establish indication for CRT-D in all heart failure patients with an indication for CRT: 1) a non complete agreement among the different societies which wrote recommendations for guidelines (a comparative table is reported); 2) a better identification of implantable patients and an amelioration of utilized devices; 3) economic and ethical ramifications of this therapy. Anyway still now the crucial question is: ''Can resynchronization be done in isolation or must be accompanied by an ICD device?''. To answer to this question we can only express which is, in our opinion, the actual position of many physicians who work in the field of pacing and electrophysiology: ''The lesson to be learned is that we still can not predict surely which patient will die of sudden death. Until a method of identifying the high risk patients can be developed, the safest strategy should be to advise a combined ICD-CRT device for patients with indication for CRT''.
Asunto(s)
Estimulación Cardíaca Artificial , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Disfunción Ventricular Izquierda/terapia , Insuficiencia Cardíaca/mortalidad , Humanos , Calidad de Vida , Análisis de Supervivencia , Disfunción Ventricular Izquierda/mortalidadRESUMEN
In recent years natriuretic peptides (NPs) have emerged as important tools for evaluation of heart failure patients. Since its approval by the Food and Drug Administration (FDA) in November 2000, recent surveys suggest that approximately 83% of hospitals in the US use some type of NP testing. Although NP testing was originally focused on rapid diagnosis of patients presenting to the emergency department with shortness of breath, clinicians regularly look to NPs for diagnosing minimally symptomatic or asymptomatic left ventricular dysfunction, and using NPs levels in clinic to help ascertain when decompensation is present. NP testing is now included in the guidelines for the diagnosis and treatment of chronic heart failure and in the Italian Consensus Document for the clinical use of NPs. Recommendations indicate that assessment of NPs can be considered a reliable rule-out test of heart failure in primary care and in the emergency room even if they stated that the role for treatment monitoring or for prognostic evaluation needs to be determined. In recent years, cardiac resynchronization therapy (CRT) was introduced as a new treatment modality for patients with systolic heart failure and several studies suggest that plasma concentration of NPs ensues as a very useful parameter for evaluating and monitoring patients who undergo CRT. Thus this article aims not only to summarise data concerning NPs measurement in patients with heart failure, but also to indicate how these markers could be utilized in the future to objectively assess effects of CRT (identification of responders). In conclusion, if further studies will confirm above mentioned remarks, it would be possible that NPs evaluation can help to tailor the more suitable therapy for each heart failure patient and, therefore, to reduce the number of failures.
Asunto(s)
Estimulación Cardíaca Artificial , Insuficiencia Cardíaca/terapia , Péptidos Natriuréticos/sangre , Arritmias Cardíacas/terapia , Biomarcadores/sangre , Insuficiencia Cardíaca/sangre , Humanos , Resultado del Tratamiento , Disfunción Ventricular Izquierda/terapiaRESUMEN
AIM: Cardiac resynchronization therapy (CRT) reduces the severity of functional mitral regurgitation (FMR) in patients with heart failure and left bundle branch block. Our hypothesis was that the induction of a more synchronous mitral valve anulus contraction can be a mechanism of FMR reduction in CRT patients. METHODS: An echo tissue Doppler imaging (TDI) examination was performed at baseline and 6 months after biventricular pacing system implant in 30 patients (4 females and 26 males, 74.1+/-6.1 years) with dilatative or ischemic chronic heart failure, NYHA class = or >III, ejection fraction (EF) = or <35% and QRS = or >140 ms. EF, Myocardial Performance Index (MPI), left end-diastolic and systolic volumes (LVEDV, LVESV), mitral regurgitation jet area/left atrial area (JA/LAA), effective regurgitant orifice area (EROA), mitral anulus contraction (MAC) were evaluated. Using TDI, at the 6 left ventricle (LV) basal segments the time to the peak myocardial sustained systolic velocity (Ts) and the standard deviation (SD) of TS were evaluated. RESULTS: At 6 months follow-up NYHA class, EF, MPI were significantly improved, LV volumes were reduced. FMR degree, evaluated both as JA/LAA and EROA, was significantly reduced. This effect was associated with the 6 basal segments resynchronization and with a more effective annular contraction. CONCLUSIONS: Our data show that CRT by resynchronizing left ventricular basal segments produces a more effective mitral valve annulus contraction and contributes to FMR improvement. Further studies need to evaluate if this could be taken into account as new therapeutic perspective of functional mitral valve regurgitation.
Asunto(s)
Insuficiencia de la Válvula Mitral/terapia , Marcapaso Artificial , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Insuficiencia de la Válvula Mitral/complicacionesRESUMEN
BACKGROUND: Atrial fibrillation has a high incidence in patients wearing an implantable cardioverter defibrillator for ventricular tachyarrhythmias and may lead to palpitations, heart failure, angina, stroke and inappropriate defibrillator discharge. The aim of the study was to evaluate the efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias. METHODS: One hundred and twelve patients, 88 male, mean age 64+/-11 years, were enrolled. Seventy-six had ischaemic heart disease, 21 idiopathic dilated cardiomyopathy, nine other heart diseases, six no structural heart disease. The mean left ventricular ejection fraction was 40+/-11%. Sixty-two had prior atrial tachyarrhythmias. RESULTS: Follow-up lasted 11+/-9 months (range 1-42). Among 933 ventricular tachyarrhythmia episodes, 100% of ventricular fibrillation and 92% of ventricular tachycardia were successfully cardioverted. Among 414 detected sustained atrial tachyarrhythmias, 195 were classified as atrial tachycardia (47.1%), 192 as atrial fibrillation (46.4%) and 27 (6.5%) as sinus rhythm. The detection-positive predictive value was 93.5%. Therapy success rates: antitachy pacing on atrial tachycardia = 71.3% (crude estimate); 66.1% (adjusted estimate); 50 Hertz on atrial fibrillation=36.2% (crude estimate); 13.5% (adjusted estimate); atrial shock on atrial fibrillation = 62.5% (mean energy 7.8+/-14.1J). Shock efficacy was 32% when delivered energy was < or = 2 atrial defibrillation threshold at implant and 92% when >2. Duration of successfully treated atrial episodes was significantly lower than that of unsuccessfully treated (6+/-26 min vs 42+/-60). CONCLUSIONS: Atrial antitachy pacing and shock therapies demonstrated very high efficacy in treating atrial tachyarrhythmias in defibrillator patients.
Asunto(s)
Fibrilación Atrial/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Marcapaso Artificial , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Fibrilación Atrial/complicaciones , Cardioversión Eléctrica/instrumentación , Diseño de Equipo , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Taquicardia Ventricular/complicaciones , Resultado del Tratamiento , Fibrilación Ventricular/complicacionesRESUMEN
BACKGROUND: New atrial pacing techniques and overdrive pacing algorithms have been introduced to prevent atrial fibrillation. This study was designed to test the hypotheses that (1) interatrial septum pacing (IASP) at the triangle of Koch would be more effective than right atrial appendage pacing (RAAP) in preventing paroxysmal atrial fibrillation (PAF) in patients with sinus bradycardia and (2) an algorithm (CAP) designed to achieve constant atrial capture would increase the efficacy of rate-responsive atrial pacing. METHODS: We studied 46 patients with PAF and sinus bradycardia implanted with a DDD(R) (Medtronic Thera) pacemaker. Twenty-four patients (6.0 +/- 10.1 PAF episodes/month within 3 months before study) were randomized to RAAP and 22 patients (5.4 +/- 7.1, not significant) to IASP. Within each arm 2 randomized crossover periods of CAP-OFF and CAP-ON function were programed. RESULTS: The PAF episodes per month significantly decreased in the RAAP (CAP-OFF: 2.1 +/- 4.2, P <.05; CAP-ON: 1.9 +/- 3.8, P <.05) and in the IASP group (CAP-OFF: 0.2 +/- 0.5, P <.05; CAP-ON: 0.2 +/- 0.5, P <.05). Values were significantly lower in the IASP group than in the RAAP group in both CAP-OFF (0.2 +/- 0.5 vs 2.1 +/- 4.2, P <.05) and CAP-ON (0.2 +/- 0.5 vs 1.9 +/- 3.8, P <.05) conditions. PAF burden was significantly lower in the IASP than in the RAAP group in CAP-OFF (47 +/- 84 min/d vs 140 +/- 217, P <.05) and in CAP-ON (41 +/- 72 vs 193 +/- 266, P <.05) conditions. No differences were observed within each arm in PAF burden between the 2 crossover CAP programing periods. CONCLUSIONS: Rate-adaptive IASP at the triangle of Koch is more effective than RAAP in preventing PAF in patients with sinus bradycardia. In our sample of patients no additional clinical benefit is furnished by the CAP algorithm.
Asunto(s)
Fibrilación Atrial/prevención & control , Bradicardia/complicaciones , Estimulación Cardíaca Artificial/métodos , Anciano , Fibrilación Atrial/etiología , Estudios Cruzados , Femenino , Humanos , Masculino , Marcapaso Artificial , Prótesis e ImplantesRESUMEN
Physiological hypertrophy represents the adaptive changes of the heart required for supporting the increased hemodynamic load in regularly trained healthy subjects. Mechanisms responsible for the athlete's hypertrophy still remain unknown. In 15 trained competitive soccer players and in 15 healthy men not engaged in sporting activities (sedentary control subjects) of equivalent age, we investigated the relationship among cardiac growth factor formation, cardiac sympathetic activity, and left ventricular morphology and function. Cardiac formation of insulin-like growth factor (IGF)-I, endothelin (ET)-1, big ET-1, and angiotensin (Ang) II was investigated at rest by measuring artery-coronary sinus concentration gradients. Cardiac sympathetic activity was studied by [(3)H]norepinephrine (NE) kinetics. Cardiac IGF-I, but not ET-1, big ET-1, and Ang II, formation was higher in athletes than in control subjects (P<0.01). NE levels in arterial and peripheral venous blood did not differ between groups. In contrast, coronary sinus NE concentration was higher in athletes than in control subjects (P<0.01). Cardiac, but not total systemic, NE spillover was also increased in athletes (P<0.01), whereas cardiac [(3)H]NE reuptake and clearance were not different. Echocardiographic modifications indicated a volume overload-induced hypertrophy associated with increased myocardial contractility. Multivariate stepwise analysis selected left ventricular mass index as the most predictive independent variable for cardiac IGF-I formation and velocity of circumferential fiber shortening for cardiac NE spillover. In conclusion, increased cardiac IGF-I formation and enhanced sympathetic activity selectively confined to the heart appear to be responsible for the physiological hypertrophy in athletes performing predominantly isotonic exercise.
Asunto(s)
Ejercicio Físico/fisiología , Corazón/inervación , Hipertrofia Ventricular Izquierda/metabolismo , Hipertrofia Ventricular Izquierda/fisiopatología , Factor I del Crecimiento Similar a la Insulina/biosíntesis , Sistema Nervioso Simpático/fisiopatología , Adulto , Angiotensina II/biosíntesis , Ecocardiografía , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Masculino , Miocardio/metabolismo , Norepinefrina/sangre , FútbolRESUMEN
BACKGROUND: It has not so far been elucidated whether the autonomic nervous system plays a role in the pathogenesis of atrial fibrillation relapse after electrical cardioversion. METHODS: In 40 consecutive patients with atrial fibrillation (22 males, 18 females, mean age 60 +/- 2 years) submitted to successful electrical cardioversion (external in 26 and low-energy internal in 14) we evaluated the heart rate variability (24-hour Holter recording) immediately after restoration of sinus rhythm in order to assess the cardiac sympatho-vagal drive. RESULTS: Patients with atrial fibrillation relapse within the first week of electrical cardioversion were characterized by a significantly higher low/high frequency ratio. CONCLUSIONS: Despite the heterogeneity of the studied population (concerning both the therapy and etiology of atrial fibrillation), our data strongly suggest that the evaluation of the low/high frequency ratio by means of power spectral analysis immediately after electrical cardioversion is a useful tool for the identification of those patients who are prone to atrial fibrillation recurrence. Our conclusions are supported by the finding of high positive and negative predictive values for the low/high frequency ratio both in the 24-hour period and during daytime.
Asunto(s)
Fibrilación Atrial/terapia , Cardioversión Eléctrica , Frecuencia Cardíaca/fisiología , Anciano , Amiodarona/uso terapéutico , Fibrilación Atrial/epidemiología , Ritmo Circadiano/fisiología , Electrocardiografía Ambulatoria , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Propafenona/uso terapéutico , Recurrencia , Sensibilidad y Especificidad , Factores de Tiempo , Vasodilatadores/uso terapéutico , Verapamilo/uso terapéuticoRESUMEN
The aim of this study was to investigate the spatial patterns of organization of fibrillation in the right atrium using bipolar recordings from a basket catheter in a population of 17 patients with persistent AF. The number of occurrences (NO) (i.e., the number of points laying on the baseline) was used as an objective measure of organization. This parameter significantly matches Wells' criteria for the classification of bipolar recordings during AF. The anatomic correspondence of the splines with eight atrial regions (namely anterior free wall, lateral free wall, posterolateral free wall, posterior free wall, posterior atrial septum, atrial septum, tricuspid valve, and anterior tricuspid valve) was assessed by fluoroscopic projections and electrogram morphology. Each region was further divided into high, mid-high, mid-low, and low segments. It was observed that individual and well-defined patterns of organization characterize the electrical activity of the right atrium in patients with persistent AF. When observed over 10 minutes, these patterns are rather stable in time. In each patient, the NO measurements were significantly different in the various right atrium regions (P < 0.0001 for all patients, Friedman test). The NO averaged over the population was significantly different among the regions (P < 0.001, Kruskal-Wallis test), owing to a common disorganized pattern observed in the tricuspid valve and anterior tricuspid valve regions. When these regions were removed from the analysis, the differences among the remaining regions were not statistically significant (P = 0.77). In conclusion, the quantitative assessment of organization in the entire right atrium showed an individual rather than common distribution. This may have implications in the choice of regions candidate for ablation.
Asunto(s)
Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/instrumentación , Anciano , Anciano de 80 o más Años , Enfermedad Crónica , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana EdadRESUMEN
Aim of this study was to investigate the spatial patterns of organization of fibrillation in the right atrium using bipolar recordings from a basket catheter. Study population consists of 17 patients with persistent atrial fibrillation (AF), selected a priori for low energy internal cardioversion. Organization was measured by the number of occurrences--i.e. the percentage number of points laying on the baseline--which has been demonstrated to match Wells' criteria for the classification of AF. Well-defined and stable patterns of organization characterize the electrical activity of the right atrium in these patients. The organization in the entire right atrium showed an individual rather than common distribution. This may have implications in the choice of regions candidate for ablation.
Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana EdadRESUMEN
Biventricular pacing has been proposed to resynchronize ventricular contraction in patients with congestive heart failure (CHF) and interventricular conduction delay. However, the sudden death rate is still high despite the improvement in cardiac performance. Devices combining biventricular pacing with implantable cardioverter defibrillator (ICD) backup are now under clinical investigation to demonstrate whether they can decrease sudden death. From the first implant of an ICD with biventricular transvenous pacing on August 1998 to April 2000, 96 patients underwent such implants: 67 (70%) received pacemakers alone and 29 (30%), who had class I ICD indications, received combined pacemaker/ICD systems. During a mean follow-up of 283 +/- 170 days, 13 (14%) patients died: 5 of 29 (17%) in the ICD group and 8 of 67 (12%) in the pacemaker group. A total of 15 patients (52%) had ICD shocks and 6 patients (21%) had 113 episodes of ventricular tachyarrhythmias, of which 96 (85%) were converted to sinus rhythm with antitachypacing. The echocardiograms showed a narrowing of the delay between the onset of right and left ventricular outflow from 40 +/- 37 msec to 17 +/- 16 msec (p = 0.03) and a reduction of the mitral regurgitation area from 7 +/- 3.8 cm2 to 5 +/- 4 cm2 (p = 0.04) at 3 months. Functional class improved from 2.8 +/- 0.7 to 1.6 +/- 0.5 (p <0.001) 3 months after implant. Thus, ischemic patients with reduced left ventricular ejection fraction and ventricular tachyarrhythmias seem good candidates for biventricular pacing with ICD backup. The sudden death risk for those with idiopathic dilated cardiomyopathy, however, is difficult to stratify, and the choice of ICD backup has to be considered on the basis of patient safety, as well as of costs.
Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/métodos , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/complicaciones , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/etiología , Desfibriladores Implantables , Femenino , Humanos , Masculino , Marcapaso ArtificialRESUMEN
Interatrial septum pacing (IASP) reduces interatrial conduction time and consequently may interfere with atrioventricular delay (AVD) optimization. We studied 14 patients with an implanted BEST Living system device able to measure peak endocardial acceleration (PEA) signal. The aims of our study were to compare the (1) optimal AVD (OAVD) in right atrial appendage pacing (RAAP) and IASP, and (2) OAVD derived by the PEA signal versus OAVD derived by Echo/Doppler evaluation of the left ventricular filling time (LVFT) and cardiac output (CO). Measurements were performed in DDD VDD modes Eight patients (group A) had RAAP and six patients (group B) had IASP. In group A, OAVD measured by LVFT, CO, and PEA was 185 +/- 23 ms, 177 +/- 19 ms, and 192 +/- 23 ms in DDD and 147 +/- 19 ms, 135 +/- 27 ms, and 146 +/- 20 ms in VDD, respectively. OAVD measured by LVFT, CO, and PEA was significantly longer in DDD mode than in VDD (P < 0.01, P < 0.01, P < 0.001). In group B, OAVD measured by LVFT, CO, and PEA was 116 +/- 19 ms, 113 +/- 10 ms, and 130 +/- 30 ms in DDD and 106 +/- 16 ms, 96 +/- 15 ms, and 108 +/- 26 ms in VDD, respectively. No statistical differences were observed between DDD and VDD. Significant correlations between OAVDs PEA derived and OAVDs LVFT and CO derived were observed (r = 0.71, r = 0.69, respectively). When new techniques of atrial stimulation, as IASP, are used an OAVD shorter and similar in VDD and DDD has to be considered. The BEST Living system could provide a valid method to ensure, in every moment, the exact required OAVD to maximize atrial contribution to CO.
Asunto(s)
Apéndice Atrial , Estimulación Cardíaca Artificial/métodos , Desfibriladores Implantables/normas , Bloqueo Cardíaco/terapia , Tabiques Cardíacos , Gasto Cardíaco , Ecocardiografía , Endocardio/diagnóstico por imagen , Femenino , Bloqueo Cardíaco/diagnóstico por imagen , Bloqueo Cardíaco/cirugía , Pruebas de Función Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tiempo de Reacción , Resultado del Tratamiento , Función Ventricular IzquierdaRESUMEN
OBJECTIVES: The purpose of this study was to investigate if single lead interatrial septum pacing could be effective in maintaining sinus rhythm in patients in whom restoration of sinus rhythm was only possible for a period of 2-24 hours after one or more previous electrical cardioversions, and in whom a sinus bradycardia was documented before arrhythmia restarted. The two hours limit was chosen because it was considered a sufficient time to implant a dual chamber pacemaker. BACKGROUND: Alternative atrial pacing techniques have been demonstrated to be successful in preventing recurrences of atrial fibrillation (AF) in patients with sinus bradycardia. Excluding the AF occurring after only a few sinus beats, at 24 hours from electrical cardioversion an early restart of chronic AF has been reported in 12% to 17% of the patients. METHODS: After sinus rhythm was restored by internal electrical cardioversion, 17 patients, 7 ablated at the AV junction, underwent a dual chamber rate response (DDDR) pacemaker implantation with a screw-in atrial lead placed in the interatrial septum. RESULTS: After a follow-up period of 17+/-5 months (range 12 to 27 months) persistence of sinus rhythm was observed in 11 patients (65%). Six patients (35%) had recurrences of paroxysmal attacks, while five (30%) were totally free of AF. Recurrence of chronic AF was observed in six cases (35%) after 2 days-12 months from implantation. No dislodgements of the atrial lead and no complications were observed at implantation and during follow-up. CONCLUSIONS: Interatrial septum pacing is a safe and feasible technique with a satisfying success rate (65%) in long-term maintaining sinus rhythm in previously unsuccessfully cardioverted patients.
Asunto(s)
Fibrilación Atrial/prevención & control , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Ablación por Catéter/métodos , Cardioversión Eléctrica/métodos , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Enfermedad Crónica , Terapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial , Resultado del TratamientoRESUMEN
BACKGROUND: Thromboembolism occurs in 0.4% to 2% of the subjects undergoing radiofrequency ablation (RFA), but its mechanisms remain unclear. Our aim was to evaluate several parameters of the hemostatic system in relation to the electrophysiologic procedure. METHODS: Thirty consecutive patients were enrolled in the study. Fifteen underwent electrophysiologic study and 15 underwent radiofrequency ablation. Before the ablation procedure, all subjects were given an intravenous heparin bolus (2500 IU). Blood samples were drawn immediately before, at the end of, and 24 hours after the procedures. Spontaneous platelet aggregation in whole blood and in platelet-rich plasma, markers of clotting activation (prothrombin fragment 1+2 and the thrombin-antithrombin complex) and the fibrinolytic system (plasminogen activator inhibitor and D-dimer) levels were evaluated. RESULTS: At the end of the procedure, spontaneous platelet aggregation in whole blood, prothrombin fragment 1+2, thrombin-antithrombin complex, and D-dimer levels increased significantly in all patients. The hemostatic changes were more marked after RFA than after electrophysiology. Spontaneous aggregation in whole blood, prothrombin fragment 1+2, and thrombin-antithrombin complex levels at 24 hours after the procedure were similar to those observed before the procedure in both groups; D -dimer levels were still elevated with respect to preprocedure levels, with a trend toward higher levels in patients undergoing RFA rather than electrophysiology. A significantly more marked activation of coagulation (prothrombin fragment 1+2, P <.005) was found in patients in whom the mean duration of energy application was higher than 23.5 seconds. CONCLUSIONS: Our data suggest that antithrombotic prevention with a prolonged administration of heparin and/or the association of antiplatelet agents should be considered in patients undergoing RFA.
Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Electrocoagulación/efectos adversos , Fibrinolíticos/uso terapéutico , Heparina/uso terapéutico , Trombosis/etiología , Trombosis/prevención & control , Adulto , Anciano , Electrofisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Agregación Plaquetaria/efectos de los fármacos , Trombosis/sangreRESUMEN
BACKGROUND: There are a variety of approaches to the prevention of atrial fibrillation (AF) with pacing. Aim of this study was to test the safety and feasibility of interatrial septum pacing at the posterior triangle of Koch for AF prevention and to exclude potential arrhythmic effects. MATERIAL AND METHODS: Interatrial septum pacing was performed in 34 patients (21 males, 13 females, mean age 69 +/- 12 years): 9 without a history and clinical evidence of atrial fibrillation (AF) (6 with sinus bradycardia, 2 with second-degree AV block, and 1 with carotid sinus hypersensitivity) and 25 with sinus bradycardia and paroxysmal atrial fibrillation (PAF) (mean symptomatic episodes/month 6.2 +/- 10). In all patients a screw-in bipolar lead was positioned in the interatrial septum superiorly to the coronary sinus. RESULTS: At implant the mean P wave amplitude was 2.5 +/- 1.5 mV, the pacing threshold was 1 +/- 0.6 V and the impedance was 907 +/- 477 Ohm. Mean P wave duration was 118 +/- 17 ms in sinus rhythm and 82 +/- 15 during interatrial septum pacing (p < 0.001). During a mean follow-up period of 10 +/- 7 months, no patients without atrial tachyarrhythmias before implantation experienced AF. During a 9 +/- 6 months follow-up we observed only 2 symptomatic arrhythmia recurrences between AF patients (mean symptomatic episodes/month 0.006 +/- 0.0022) (p < 0.01 vs before implant period). CONCLUSIONS: Our data indicate that interatrial septal pacing is safe and feasible. A significant less incidence of arrhythmic episodes has been observed during follow-up. Further controlled randomized prospective studies are necessary to establish the exact role of this technique respect to conventional or multisite stimulation when patients with paroxysmal AF need to be permanently paced.