Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
Tipo de estudio
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
2.
Stud Health Technol Inform ; 281: 834-838, 2021 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-34042791

RESUMEN

It is necessary for hospitals to be able to compare the usability of electronic health records (EHR) before acquisition. Adding usability as a critical element of the procurement process is therefore crucial. During the competitive usability evaluation of several EHRs, the usability walkthrough method has the potential of making end-users more active in the procurement process than demonstrations. This case study presents first results of a comparison of three EHRs performed by nine representative end-users. All users uncovered usability problems while performing their scenarios. The results show that none of the EHRs evaluated is without major usability problems. These problems have been well-known to human factors researchers for a long time.


Asunto(s)
Registros Electrónicos de Salud , Interfaz Usuario-Computador , Hospitales , Humanos , Investigadores
3.
Respir Care ; 50(8): 1050-61, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16225710

RESUMEN

BACKGROUND: Auto-regulated inspiratory support mode (ARIS) is an original closed-loop pressure-support system that regulates the slope ("A") and the initial level ("B") of the applied inspiratory pressure, in order to achieve an optimal minute ventilation under constrained respiratory frequency, tidal volume, and maximum inspiratory airway pressure. The servo-controlled design results in a more or less decreasing applied pressure. OBJECTIVE: The aim of this study was to evaluate the ARIS behavior, compared with pressure-support ventilation at a constant applied pressure. METHODS: ARIS and pressure-support ventilation were randomly applied to 2 pig models of increasing ventilatory demand induced by a rebreathing test (n = 6), and of altered lung compliance induced by bronchoalveolar lavage (n = 6). The breathing pattern, work of breathing, and blood gas values were compared. ARIS automatically increased the mean inspiratory airway pressure in both groups. This increase was obtained in the rebreathing group by increasing "B" (35 +/- 3.5 cm H2O vs 42.8 +/- 2.5 cm H2O) and in the lung-injury group by decreasing the absolute value of "A" (25 +/- 5.5 cm H2O/s vs 14.7 +/- 8.6 cm H2O/s). RESULTS: There were significant differences (p < 0.05) between ARIS and pressure-support ventilation. In the rebreathing group, tidal volume was 692 +/- 63 mL versus 606 +/- 96 mL, work of breathing was 1.17 +/- 0.45 J/L versus 1.44 +/- 0.27 J/L, and P(aCO2) was 54 +/- 9 mm Hg versus 63 +/- 7 mm Hg. In the lung-injury group, respiratory frequency was 25 +/- 4 breaths/min versus 42 +/- 10 breaths/min, tidal volume was 477 +/- 67 mL versus 300 +/- 63 mL, work of breathing was 0.54 +/- 0.3 J/L versus 0.99 +/- 0.45 J/L, and P(aCO2) was 36 +/- 8 mm Hg versus 53 +/- 15 mm Hg. CONCLUSIONS: The ARIS servo control operates correctly, maintaining efficient ventilation facing an increase in respiratory demand or a decrease in respiratory system compliance.


Asunto(s)
Homeostasis , Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria , Animales , Femenino , Francia , Inhalación/fisiología , Consumo de Oxígeno , Sus scrofa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA