Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(1): 44-53, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36259713

RESUMEN

BACKGROUND: Renal denervation (RDN) can reduce cardiac sympathetic activity maintained by arterial hypertension (aHT). Its potential antiarrhythmic effect on rhythm outcome in patients with multi-drug resistant aHT undergoing catheter ablation for atrial fibrillation (AF) is unclear. METHODS: The RDN+AF study was a prospective, randomized, two-center trial. Patients with paroxysmal or persistent AF and uncontrolled aHT (mean systolic 24-h ambulatory BP > 135 mmHg) despite taking at least three antihypertensive drugs were enrolled. Patients were 1:2 randomized to either RDN+AF ablation or AF-only ablation. Primary endpoint was freedom from any AF episode > 2 min at 12 months assessed by implantable loop recorder (ILR) or 7d-holter electrocardiogram. Secondary endpoints included rhythm outcome at 24 months, blood pressure control, periprocedural complications, and renovascular safety. RESULTS: The study randomized 61 patients (mean age 65 ± 9 years, 53% men). At 12 months, RDN+AF patients tended to have a greater decrease in ambulatory BPs but did not reach statistical significance. No differences in rhythm outcome were observed. Freedom from AF recurrence in the RDN+AF and AF-only group measured 61% versus 53% p = .622 at 12 months and 39% versus 47% p = .927 at 24 months, respectively. Periprocedural complications occurred in 9/61 patients (15%). No patient died. CONCLUSION: Among patients with multidrug-resistant aHT and paroxysmal or persistent AF, concomitant RDN+AF ablation was not associated with better blood pressure control or rhythm outcome in comparison to AF-only ablation and medical therapy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Hipertensión , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Resultado del Tratamiento , Hipertensión/diagnóstico , Hipertensión/cirugía , Simpatectomía/efectos adversos , Ablación por Catéter/efectos adversos , Recurrencia
2.
NEJM Evid ; 1(11): EVIDoa2200141, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38319851

RESUMEN

BACKGROUND: Clinically effective ablation approaches for patients with persistent atrial fibrillation (AF) are still being debated. So far, ablation targets and strategies beyond pulmonary vein isolation (PVI) have failed to show systematic outcome improvement in randomized controlled clinical trials. METHODS: We conducted a multicenter, randomized trial to determine whether PVI plus individualized substrate ablation of atrial low-voltage myocardium improves outcome in patients with persistent AF. We randomly assigned 324 patients in a 1:1 ratio to receive PVI alone (163 patients; PVI only) or PVI plus substrate modification (161 patients; PVI+SM). The primary study end point was the first recurrence of an atrial arrhythmia longer than 30 seconds after single ablation, with 3 months blanking, using serial 7-day electrocardiogram recordings over 12 months of observation. Patients were also encouraged to receive implantable cardiac monitors. RESULTS: The primary study end point occurred in 75 PVI-only patients (50%) and in 54 PVI+SM patients (35%) (Kaplan­Meier event rate estimates: hazard ratio=0.62, 95% confidence interval [CI]=0.43 to 0.88, log rank P=0.006). Adverse events occurred in three PVI-only patients (1.8%) and in six PVI+SM patients (3.7%) (difference: −1.9 percentage points, 95% CI=−5.5 to 1.7 percentage points). Implant monitoring was used in 242 patients. Among them, 65 PVI-only patients (55%) versus 47 PVI+SM patients (39%) experienced recurrences (difference: 15 percentage points, 95% CI=3 to 28 percentage points). CONCLUSIONS: In this randomized trial, PVI plus individualized ablation of atrial low-voltage myocardium significantly improved outcomes in patients with persistent AF. (ClinicalTrials.gov number, NCT02732626.)


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Miocardio , Recurrencia , Resultado del Tratamiento
4.
Europace ; 23(9): 1400-1408, 2021 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-33693595

RESUMEN

AIMS: To characterize the association of phasic left atrial (LA) transport function and LA fibrosis guided by multimodality imaging containing cardiac magnetic resonance imaging (CMR) feature tracking and bipolar voltage mapping. METHODS AND RESULTS: Consecutive patients presenting for first-time ablation of atrial fibrillation (AF) were prospectively enrolled. Each patient underwent CMR prior to the ablation procedure. LA phasic indexed volumes (LA-Vi) and emptying fractions (LA-EF) were calculated and CMR feature tracking guided LA wall motion analysis was performed. LA bipolar voltage mapping was carried out in sinus rhythm to find areas of low voltage as a surrogate for fibrosis and arrhythmogenesis. One hundred and sixty-eight patients were enrolled. Low-voltage areas (LVAs) were present in 70 patients (42%). Contrary to LA volume, CMR based LA-EF [odds ratio (OR) 0.88, 95% confidence interval (CI) 0.80-0.96, P = 0.005] and LA booster pump strain rate (SR) (OR 0.98, 95% CI 0.97-0.99, P = 0.001) significantly predicted presence and extent of LVA in multivariate logistic regression analysis for patients scanned in SR. In receiver operating characteristic analysis, LA-EF <40% carried a sensitivity of 83% and specificity of 76% (area under the curve 0.8; 95% CI 0.71-0.89) to predict presence of LVA. For patients scanned in AF only minimal LA-Vi on CMR (OR: 1.06; 95% CI: 1.02-1.10; P = 0.002) predicted presence of LVA. CONCLUSION: For patients scanned in SR LA-EF and LA booster pump SR are closely linked to the presence and extent of LA LVA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Fibrosis , Atrios Cardíacos/cirugía , Humanos , Espectroscopía de Resonancia Magnética
5.
Europace ; 22(12): 1812-1821, 2020 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-32830233

RESUMEN

AIMS: Atrial fibrillation (AF) and heart failure (HF) often coexist. Catheter ablation has been reported to restore left ventricular (LV) function but patients benefit differently. This study investigated the correlation between left atrial (LA) fibrosis extent and LV ejection fraction (LVEF) recovery after AF ablation. METHODS AND RESULTS: In this study, 103 patients [64 years, 69% men, 79% persistent AF, LVEF 33% interquartile range (IQR) (25-38)] undergoing first time AF ablation were investigated. Identification of LA fibrosis and selection of ablation strategy were based on sinus rhythm voltage mapping. Continuous rhythm monitoring was used to assess ablation success. Improvement in post-ablation LVEF was measured as primary study endpoint. An absolute increase in post-ablation LVEF ≥10% was defined as 'Super Response'. Left atrial fibrosis was present in 38% of patients. After ablation LVEF increased by absolute 15% (IQR 6-25) (P < 0.001). Left ventricular ejection fraction improvement was higher in patients without LA fibrosis [15% (IQR 10-25) vs. 10% (IQR 0-20), P < 0.001]. An inverse correlation between LVEF improvement and the extent of LA fibrosis was found (R2 = 0.931). In multivariate analysis, the presence of LA fibrosis was the only independent predictor for failing LVEF improvement [odds ratio 7.2 (95% confidence interval 2.2-23.4), P < 0.001]. Echocardiographic 'Super Response' was observed in 55/64 (86%) patients without and 21/39 (54%) patients with LA fibrosis, respectively (P < 0.001). CONCLUSION: Presence and extent of LA fibrosis predict LVEF response in HF patients undergoing AF ablation. The assessment of LA fibrosis may impact prognostic stratification and clinical management in HF patients with AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Femenino , Fibrosis , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
6.
J Cardiovasc Electrophysiol ; 31(4): 885-894, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32037614

RESUMEN

BACKGROUND: Left atrial substrate modification targeting low voltage zones (LVZ) is an ablation strategy that-in addition to pulmonary vein (PV) isolation-tries to eliminate arrhythmogenic mechanisms harbored in such tissue. Electrophysiological findings at reablation include (a) PV reconnection, (b) reconnection over previous substrate ablation, and (c) de-novo LVZ. OBJECTIVE: To study, prevalence and contribution of these arrhythmogenic electrophysiological entities in patients with atrial fibrillation (AF) recurrences. METHODS: Consecutive patients with highly symptomatic AF undergoing index and reablation were included (n = 113). In all patients' PV reconnection, reconnection over previous substrate ablation and spontaneous de-novo LVZ were quantitatively assessed and integrated into an individual reablation strategy. Follow-up was based on continuous device monitoring. RESULTS: At re-do procedure, 45 out of 113 (39.8%) patients showed PV reconnection as the only electrophysiological abnormality. Reconduction over previous lines was the only electrophysiological abnormality in 8 out of 113 (7.1%) patients. Spontaneous de-novo LVZ was the only electrophysiological abnormality in 12 out of 113 (10.6%) patients. Combined findings of PV reconnection, line reconduction, and/or spontaneous de-novo LVZ were seen in 40 out of 113 (35.4%) patients. No detectable electrophysiological abnormality was observed in 8 out of 113 (7.1%) patients. In univariate analysis, none of the tested electrophysiological characteristics independently predicted the outcome after re-do. CONCLUSIONS: In patients undergoing reablation, we could show that reconduction over previous substrate ablation as well as the development of new low voltage areas are frequent findings besides classical PV reconnection-without a clear leading cause for recurrences. These findings impact reablation strategies as well as the strategic focus during index procedures.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
Europace ; 20(FI_3): f312-f320, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29688326

RESUMEN

Aims: To study device performance, arrhythmia recurrence characteristics, and methods of outcome assessment using a novel implantable cardiac monitor (ICM) in patients undergoing ablation for atrial fibrillation (AF). Methods and results: In 419 consecutive patients undergoing first-time catheter ablation for symptomatic paroxysmal (n = 224) or persistent (n = 195) AF an ICM was injected at the end of the procedure. Telemedicine staff ensured full episode transmission coverage and manually evaluated all automatic arrhythmia episodes. Device detection metrics were calculated for ≥2, ≥6, and ≥10 min AF detection durations. Four methods of outcome assessment were studied: continuous recurrence analysis, discontinuous recurrence analysis, AF-burden analysis, and analysis of individual rhythm profiles. A total of 43 673 automatic AF episodes were transmitted over a follow-up of 15 ± 6 months. Episode-based positive predictive values changed significantly with longer AF detection durations (70.5% for ≥2 min, 81.8% for ≥6 min, and 85.9% for ≥10 min). Patients with exclusive short episode recurrences (≥2 to <6 min) were rare and their arrhythmia detection was clinically irrelevant. Different methods of outcome assessment showed a large variation (46-79%) in ablation success. Individual rhythm characteristics and subclinical AF added to this inconsistency. Analysis of AF-burden and individual rhythm profiles were least influenced and showed successful treatment in 60-70% of the patients. Conclusion: We suggest AF detection duration >6 min and AF burden >0.1% as a standardized outcome definition for AF studies to come in the future.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Electrocardiografía Ambulatoria/métodos , Frecuencia Cardíaca , Telemedicina/métodos , Telemetría/métodos , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Equipo para Diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Diseño de Equipo , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recurrencia , Telemedicina/instrumentación , Telemetría/instrumentación , Factores de Tiempo , Resultado del Tratamiento
8.
Circ Arrhythm Electrophysiol ; 11(2): e005748, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29439000

RESUMEN

BACKGROUND: Until today, catheter interventional mapping and ablation of atrial fibrillation (AF) has been limited to the right and left atrial endocardium. We report feasibility, electrophysiological findings, and clinical outcome using a combined endo-/epicardial catheter approach for mapping and ablation of AF. METHODS AND RESULTS: Fifty-nine patients with permanence of pulmonary vein isolation and further symptomatic recurrences of paroxysmal AF, persistent AF, or atrial tachycardia underwent reablation using biatrial endo-/epicardial mapping and ablation. Identification of arrhythmia substrates and selection of ablation strategy were based on sinus rhythm voltage mapping. Using continuous monitoring and a 3-month blanking period, freedom from AF/atrial tachycardia ≥2 minutes was defined as primary end point. In all patients, endo-/epicardial mapping and ablation was feasible using standard technologies of catheter access, 3-dimensional mapping, and radiofrequency ablation. Epicardial mapping and ablation did not add procedural risks. Exclusively epicardial low voltage substrates were found in 14% of the patients. For the first time, novel epicardial conduction abnormalities located in the epicardial fiber network were described in human AF patients (19% of the cohort). Epicardial ablation was needed in 80% of the patients. Over 23±10 months of follow-up freedom from arrhythmia recurrences measured 73%. CONCLUSIONS: Catheter-based endo-/epicardial mapping and ablation of AF was feasible and safe. Epicardial mapping provided new insights into AF mechanisms. Epicardial ablation increased transmurality of ablation lesions. Clinical outcome in this cohort of complex AF patients was favorable, indicating potential further development of current AF treatment.


Asunto(s)
Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Endocardio/cirugía , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Pericardio/cirugía , Anciano , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Estudios de Factibilidad , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA