Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Transfusion ; 59(S2): 1429-1438, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30980748

RESUMEN

BACKGROUND: Despite countless advancements in trauma care a survivability gap still exists in the prehospital setting. Military studies clearly identify hemorrhage as the leading cause of potentially survivable prehospital death. Shifting resuscitation from the hospital to the point of injury has shown great promise in decreasing mortality among the severely injured. MATERIALS AND METHODS: Our regional trauma network (Southwest Texas Regional Advisory Council) developed and implemented a multiphased approach toward facilitating remote damage control resuscitation. This approach required placing low-titer O+ whole blood (LTO+ WB) at helicopter emergency medical service bases, transitioning hospital-based trauma resuscitation from component therapy to the use of whole blood, modifying select ground-based units to carry and administer whole blood at the scene of an accident, and altering the practices of our blood bank to support our new initiative. In addition, we had to provide information and training to an entire large urban emergency medical system regarding changes in policy. RESULTS: Through a thorough, structured program we were able to successfully implement point-of-injury resuscitation with LTO+ WB. Preliminary evaluation of our first 25 patients has shown a marked decrease in mortality compared to our historic rate using component therapy or crystalloid solutions. Additionally, we have had zero transfusion reactions or seroconversions. CONCLUSION: Transfusion at the scene within minutes of injury has the potential to save lives. As our utilization expands to our outlying network we expect to see a continued decrease in mortality among significantly injured trauma patients.


Asunto(s)
Bancos de Sangre , Conservación de la Sangre/normas , Transfusión Sanguínea/normas , Redes Comunitarias , Servicios Médicos de Urgencia , Hemorragia/terapia , Resucitación , Centros Traumatológicos , Sistema del Grupo Sanguíneo ABO , Bancos de Sangre/organización & administración , Bancos de Sangre/normas , Redes Comunitarias/organización & administración , Redes Comunitarias/normas , Soluciones Cristaloides/administración & dosificación , Servicios Médicos de Urgencia/organización & administración , Servicios Médicos de Urgencia/normas , Femenino , Hemorragia/mortalidad , Humanos , Masculino , Texas , Centros Traumatológicos/organización & administración , Centros Traumatológicos/normas
2.
J Trauma Acute Care Surg ; 83(6): 1187-1194, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28885469

RESUMEN

BACKGROUND: Tension pneumothorax is a cause of potentially preventable death in prehospital and battlefield settings and 14-gauge angiocatheter (14G AC) decompression remains the current treatment standard, despite its high incidence of failure. Traumatic pneumothorax is often associated with hemothorax, but 14G AC has no proven efficacy for associated hemothorax. We sought to compare the 14G AC to three alternative devices for treatment of tension hemopneumothorax (t-H/PTX) in a positive-pressure ventilation swine model. METHODS: Our tension model was modified to incorporate a persistent air leak and pleural blood. Tension physiology was achieved with escalating carbon dioxide insufflation via transdiaphragmatic trocar, and 10% estimated blood volume was instilled into each chest. Intervention was randomized between 14G AC, 10-gauge angiocatheter (10G AC), modified Veress-type needle (mVN), and 3-mm laparoscopic trocar (LT). After recovery, serial tension-induced pulseless electrical activity (PEA) events were induced and decompressed. Success of rescue, time to rescue, and physiologic data were recorded. RESULTS: One hundred ninety-five t-H/PTX and 88 PEA events were conducted in 25 swine. Laparoscopic trocar and 10G AC were more successful and had faster median time to rescue for t-H/PTX compared with 14G AC, whereas mVN performed comparably. Following PEA, 14G AC and mVN succeeded at rescue only 50% and 57% of the time, whereas 10G AC and LT had 100% success at return of spontaneous circulation. Time to successful return of circulation following PEA did not differ between devices; however, there was a noticeable difference in the rate of meaningful hemodynamic recovery following PEA favoring LT and 10G AC. There were no significant injuries noted. CONCLUSIONS: While mVN performed comparably to 14G AC, both have unacceptable failure rates. Ten-gauge AC and LT performed superiorly in both t-H/PTX and PEA. We believe there is now ample evidence supporting replacement of the 14G AC with 10G AC in current treatment recommendations.


Asunto(s)
Ablación por Catéter/instrumentación , Descompresión Quirúrgica/métodos , Hemoneumotórax/cirugía , Traumatismos Torácicos/complicaciones , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Femenino , Hemoneumotórax/etiología , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA