Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
Neural Netw ; 166: 634-644, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37604074

RESUMEN

Among several approaches to tackle the problem of energy consumption in modern computing systems, two solutions are currently investigated: one consists of artificial neural networks (ANNs) based on photonic technologies, the other is a different paradigm compared to ANNs and it is based on random networks of non-linear nanoscale junctions resulting from the assembling of nanoparticles or nanowires as substrates for neuromorphic computing. These networks show the presence of emergent complexity and collective phenomena in analogy with biological neural networks characterized by self-organization, redundancy, and non-linearity. Starting from this background, we propose and formalize a generalization of the perceptron model to describe a classification device based on a network of interacting units where the input weights are non-linearly dependent. We show that this model, called "receptron", provides substantial advantages compared to the perceptron as, for example, the solution of non-linearly separable Boolean functions with a single device. The receptron model is used as a starting point for the implementation of an all-optical device that exploits the non-linearity of optical speckle fields produced by a solid scatterer. By encoding these speckle fields we generated a large variety of target Boolean functions. We demonstrate that by properly setting the model parameters, different classes of functions with different multiplicity can be solved efficiently. The optical implementation of the receptron scheme opens the way for the fabrication of a completely new class of optical devices for neuromorphic data processing based on a very simple hardware.


Asunto(s)
Generalización Psicológica , Nanocables , Redes Neurales de la Computación , Fotones
2.
J Synchrotron Radiat ; 30(Pt 1): 217-226, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36601940

RESUMEN

FOCUS (Fast Monte CarlO approach to Coherence of Undulator Sources) is a new GPU-based simulation code to compute the transverse coherence of undulator radiation from ultra-relativistic electrons. The core structure of the code, which is written in the language C++ accelerated with CUDA, combines an analytical description of the emitted electric fields and massively parallel computations on GPUs. The combination is rigorously justified by a statistical description of synchrotron radiation based on a Fourier optics approach. FOCUS is validated by direct comparison with multi-electron Synchrotron Radiation Workshop (SRW) simulations, evidencing a reduction in computation times by up to five orders of magnitude on a consumer laptop. FOCUS is then applied to systematically study the transverse coherence in typical third- and fourth-generation facilities, highlighting peculiar features of undulator sources close to the diffraction limit. FOCUS is aimed at fast evaluation of the transverse coherence of undulator radiation as a function of the electron beam parameters, to support and help prepare more advanced and detailed numerical simulations with traditional codes like SRW.

3.
Mater Horiz ; 8(5): 1570-1586, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34846465

RESUMEN

We find significant differences between degradation and healing at the surface or in the bulk for each of the different APbBr3 single crystals (A = CH3NH3+, methylammonium (MA); HC(NH2)2+, formamidinium (FA); and cesium, Cs+). Using 1- and 2-photon microscopy and photobleaching we conclude that kinetics dominate the surface and thermodynamics the bulk stability. Fluorescence-lifetime imaging microscopy, as well as results from several other methods, relate the (damaged) state of the halide perovskite (HaP) after photobleaching to its modified optical and electronic properties. The A cation type strongly influences both the kinetics and the thermodynamics of recovery and degradation: FA heals best the bulk material with faster self-healing; Cs+ protects the surface best, being the least volatile of the A cations and possibly through O-passivation; MA passivates defects via methylamine from photo-dissociation, which binds to Pb2+. DFT simulations provide insight into the passivating role of MA, and also indicate the importance of the Br3- defect as well as predicts its stability. The occurrence and rate of self-healing are suggested to explain the low effective defect density in the HaPs and through this, their excellent performance. These results rationalize the use of mixed A-cation materials for optimizing both solar cell stability and overall performance of HaP-based devices, and provide a basis for designing new HaP variants.

4.
Opt Express ; 29(10): 14412-14424, 2021 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-33985165

RESUMEN

We describe an innovative data transmission scheme exploiting optical vortices to multiplex and demultiplex independent data channels in a standard asynchronous laser link. We report extensive results of the proof of concept of the method, successfully used to transmit two parallel ASCII strings, demultiplexed and decoded in the far field of the radiation beam. A phase locked two arms interferometer is proved to be effective even accessing a small portion of the beam only. Results prove the robustness and reliability of the method to perform dense-code free space transmissions over long distances even in presence of wavefront distortions. Applications and the extension to a larger number of parallel channels are discussed.

5.
Appl Opt ; 59(17): 5258-5264, 2020 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-32543547

RESUMEN

We show a method to measure the topological charge of orbital angular momentum radiation in single-shot by exploiting the intrinsic local curvature of the helicoidal wavefront. The method is based on oriented Hartmann cells in a suitable detection scheme. We show experimental results and propose a Shack-Hartmann configuration with sectored photodiodes to improve resolution and detection time. The method can be applied for telecommunication applications in the far field of the radiation beam and more in general to measure the topological charge from a small portion of the radiation wavefront.

6.
Opt Express ; 27(13): 17550-17560, 2019 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-31252712

RESUMEN

We describe a method for effectively distinguishing the radiation endowed with optical angular momentum, also known as optical vortex, from ordinary light. We show that by detecting the inversion of the transverse intrinsic curvature sign (ITICS) an optical vortex can be locally recognized. The method is effective under conditions of huge importance for the exploitation of optical vortices, such as the far field of the source and access to a small fraction of the wavefront only. The validity of the method has been verified with table-top experiments with visible light, and the results show that a measurement performed over a transverse distance smaller than 4% of the beam diameter distinguishes a vortex from a Gaussian beam with a significance of 93.4%. New perspectives are considered for the characterization of vortices, with potential impact on the detection of extra-terrestrial radiation as well as on broadcast communication techniques.

7.
Eur Rev Med Pharmacol Sci ; 23(10): 4439-4447, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31173320

RESUMEN

OBJECTIVE: Pharmacological post-conditioning (PC) by intermittent but not continuous administration of exogenous bradykinin (BK) reduces ischemia/reperfusion (I/R) injury via the Reperfusion Injury Salvage Kinase (RISK) pathway activation. We evaluated whether intermittent administration with icatibant (HOE140), a BK2R antagonist, may represent an effective PC strategy, with the advantage of limiting the potential risks of supra-physiologic BK activity. MATERIALS AND METHODS: Hearts from male Sprague-Dawley (SD) rats on a Langendorff system were exposed to I/R injury (30/120 min). BK (100 nM) and HOE140 (1 µM) were administered post-ischemically during the first 3 min of reperfusion, under continuous or intermittent infusion (10 s/each). Hearts were randomly assigned to 5 groups: 1) I/R alone (n=5); 2) continuous HOE140 (cHOE n=6); 3) intermittent HOE140 (iHOE n=6); 4) continuous BK (cBK n=6); 5) intermittent BK (iBK n=6). End-diastolic left ventricular pressure (LVEDP), developed left ventricular pressure (dLVP) and coronary flow (CF) were monitored throughout reperfusion. Left ventricular infarct mass (IM) was quantified together with the phosphorylated levels of Akt and GSK3ß (RISK pathway kinases) at the end of reperfusion. RESULTS: IM was not significantly changed in cBK or cHOE groups (vs. I/R). Conversely, both iBK and iHOE groups showed a significant limitation in IM (vs. I/R, p<0.05, p<0.01, respectively). Akt and GSK3ß phosphorylation levels were higher in iBK and iHOE groups (vs. I/R, p<0.05). When compared to I/R group, both LVEDP values (p<0.05, first 60-min reperfusion), as well as dLVP values (p<0.01) were improved only in iHOE group. CF values did not vary among all groups. CONCLUSIONS: In isolated rat hearts, intermittent modulation of the endogenous kallikrein-kinin system by a selective BK2R antagonist mediates PC cardioprotection via RISK signaling.


Asunto(s)
Antagonistas de los Receptores de Bradiquinina/farmacología , Bradiquinina/análogos & derivados , Corazón/efectos de los fármacos , Poscondicionamiento Isquémico , Cininas/metabolismo , Receptor de Bradiquinina B2/efectos de los fármacos , Animales , Presión Sanguínea/efectos de los fármacos , Bradiquinina/farmacología , Circulación Coronaria/efectos de los fármacos , Glucógeno Sintasa Quinasa 3 beta/genética , Masculino , Infarto del Miocardio/patología , Daño por Reperfusión Miocárdica/patología , Daño por Reperfusión Miocárdica/prevención & control , Proteína Oncogénica v-akt/genética , Ratas , Ratas Sprague-Dawley , Transducción de Señal/efectos de los fármacos , Función Ventricular Izquierda/efectos de los fármacos
8.
Nanoscale ; 9(8): 2778-2784, 2017 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-28155930

RESUMEN

The shape and size of nanoparticles are important parameters affecting their biodistribution, bioactivity, and toxicity. The high-throughput characterisation of the nanoparticle shape in dispersion is a fundamental prerequisite for realistic in vitro and in vivo evaluation, however, with routinely available bench-top optical characterisation techniques, it remains a challenging task. Herein, we demonstrate the efficacy of a single particle extinction and scattering (SPES) technique for the in situ detection of the shape of nanoparticles in dispersion, applied to a small library of anisotropic gold particles, with a potential development for in-line detection. The use of SPES paves the way to the routine quantitative analysis of nanoparticles dispersed in biologically relevant fluids, which is of importance for the nanosafety assessment and any in vitro and in vivo administration of nanomaterials.

9.
Opt Express ; 24(22): 25676-25683, 2016 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-27828503

RESUMEN

We report in this work the first experimental verification of the asymmetric lateral coherence which is a measurement of the spatio-temporal coherence by using a wide-band Young interference experiment with a fixed off-axis slit. We demonstrate the coherence properties through the measurement of the real part of the coherence factor of thermal light. We extend our recent results obtained for betatron and undulator radiations providing a robust experimental method for the two-dimensional mapping of the two-point correlation function of broadband radiation preserving the phase information. The proposed method can be used as a high-sensitivity alternative to traditional interferometry with quasi-monochromatic radiation.

10.
Sci Rep ; 6: 28162, 2016 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-27306584

RESUMEN

Mineral dust aerosol (dust) is widely recognized as a fundamental component of the climate system and is closely coupled with glacial-interglacial climate oscillations of the Quaternary period. However, the direct impact of dust on the energy balance of the Earth system remains poorly quantified, mainly because of uncertainties in dust radiative properties, which vary greatly over space and time. Here we provide the first direct measurements of the aerosol optical thickness of dust particles windblown to central East Antarctica (Dome C) during the last glacial maximum (LGM) and the Holocene. By applying the Single Particle Extinction and Scattering (SPES) technique and imposing preferential orientation to particles, we derive information on shape from samples of a few thousands of particles. These results highlight that clear shape variations occurring within a few years are hidden to routine measurement techniques. With this novel measurement method the optical properties of airborne dust can be directly measured from ice core samples, and can be used as input into climate model simulations. Based on simulations with an Earth System Model we suggest an effect of particle non-sphericity on dust aerosol optical depth (AOD) of about 30% compared to spheres, and differences in the order of ~10% when considering different combinations of particles shapes.

11.
Rev Sci Instrum ; 87(12): 126104, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28040961

RESUMEN

We developed a broad-spectrum light source specifically designed to reproduce the temporal behavior of the optical pulses emitted by scintillators for X-ray detection. Nanosecond-to-millisecond pulses are generated through a fast circuit driving Light Emitting Diodes (LEDs) and are endowed with the peculiar time features of the most employed scintillators by means of a dedicated pulse shaping stage. We implement the light source for the optical modeling of the single-shot X-ray coherence measurements with near-field speckles generated by the scattering from colloidal suspensions (heterodyne near field speckle method). Moreover, we derive a rigorous scaling law that quantitatively relates visible and X-ray signal-to-noise ratios.

12.
Opt Express ; 23(23): 29912-20, 2015 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-26698473

RESUMEN

By exploiting analogical optical modeling of the radiation emitted by ultrarelativistic electrons undergoing betatron oscillations, we demonstrate peculiar properties of the spatial coherence through an interferometric method reminiscent of the classical Young's double slit experiment. The expected effects due to the curved trajectory and the broadband emission are accurately reproduced. We show that by properly scaling the fundamental parameters for the wavelength, analogical optical modeling of betatron emission can be realized in many cases of broad interest. Applications to study the feasibility of future experiments and to the characterization of beam diagnostics tools are described.

13.
Sci Rep ; 5: 18228, 2015 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-26667064

RESUMEN

The behavior of nanoparticles in biological systems is determined by their dimensions, size distribution, shape, surface chemistry, density, drug loading and stability; the characterization of these parameters in realistic conditions and the possibility to follow their evolution in vitro and in vivo are, in most of the cases, far from the capabilities of the standard characterization technologies. Optical techniques such as dynamic light scattering (DLS) are, in principle, well suited for in line characterization of nanoparticle, however their fail in characterizing the evolution of nanoparticle in solution where change in particle dimension and density is present. Here we present an in-line optical technique based on single particle extinction and scattering (SPES) overcoming the limitations typical of DLS and allowing for the efficient characterization of nanoparticle polydispersity, index of refraction and degradation dynamics in solution. Using SPES, we characterized the evolution of PLGA nanoparticles with different structures and drug payloads in solution and we compared the results with DLS. Our results suggest that SPES could be used as a process analytical technology for pharmaceutical nanoparticle production.


Asunto(s)
Portadores de Fármacos/química , Sistemas de Liberación de Medicamentos , Nanopartículas/química , Polímeros/química , Dispersión de Radiación
14.
Clin Ter ; 166(3): e140-5, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26152622

RESUMEN

BACKGROUND AND HYPOTHESIS: There is currently no consensus regarding superiority of the intramedullary fixation over the sliding hip screw. Regional variation remains high and not backed up by solid evidence. Given these premises we aimed to analyze weather implant preference can influence the postoperative survival. Secondary objectives were determining the trend for implant choice and confounding factors associated with intramedullary nails compared to sliding hip screws. PATIENTS AND METHODS: Retrospective data was obtained from patient charts with the main diagnosis of extracapsular/ trochanteric fractures, corresponding to ICD S72.1 codes. Between 2008-2012, 441 patients underwent osteosynthesis with a dynamic hip screw and 155 with intramedullary nail respectively. The living status was determined by comparing the patient identification number against the national population evidence records. RESULTS: The lifetable shows similar survival for both implants over the 5 year period. The yearly mortality was 19.4% for the dynamic hip screw and 21.8% for the intramedullary implant respectively, even though the later were used predominantly in older patients. This age difference is significant according to both parametric and non-parametric tests whereas duration of hospital stay are similar. We found a clear increase in the proportion of intramedullary implants, for a total of 11.2% over the 5 year period. There is no difference for the one year mortality and overall survival between sliding screw plates and intramedullary constructs. CONCLUSIONS: A clear increase in the use of intramedullary implants for trochanteric fractures was observed. This is even more apparent for older ages, presumably due to an higher surgeon confidence with the biomechanical stability of the intramedullary constructs.


Asunto(s)
Fijación Intramedular de Fracturas/métodos , Fracturas de Cadera/cirugía , Clavos Ortopédicos , Tornillos Óseos , Fijación Intramedular de Fracturas/mortalidad , Fracturas de Cadera/mortalidad , Humanos , Tiempo de Internación , Estudios Retrospectivos
15.
Clin Ter ; 166(3): e153-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26152624

RESUMEN

BACKGROUND AND AIM: The possibility to predict surgical site infections development could be of high prognostic value. We aimed to investigate whether cultures obtained from the tip of the closed passive wound drain may provide early signs of progression towards periprosthetic joint infections. MATERIALS AND METHODS: We performed an observational study on consecutive primary total knee arthroplasties performed in our department over 4 years by two high volume surgeons (it means they do a lot of arthroplasties/year; it is orthopedics specific). A total of 284 knees in 257 patients were included. Follow up was available for an average of 18.7 months. There were no simultaneous procedures. RESULTS: Nineteen (6.69%) drain tips yielded positive cultures, for a mean duration, from surgery to sample collection, of 1.63 (0.5) days. None of the positive drain tip cultures developed clinical signs of infection and all knees were healed at discharge after a mean of 13.78 days (SD= 3.34; range= 8-18). None of the 7 (2.46%) cases who developed deep infections had positive drain tip cultures. A true positive value of 0 led to a positive predictive value of 0, a negative predictive value of 97.34%, sensitivity of 0% and specificity of 93.14. CONCLUSIONS: The diagnostic use of passive drain tip cultures to detect early infections after total knee replacement is therefore absolutely useless.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Infecciones Relacionadas con Prótesis/epidemiología , Anciano , Drenaje , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Infecciones Relacionadas con Prótesis/microbiología , Sensibilidad y Especificidad
16.
Clin Ter ; 166(3): e158-64, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26152625

RESUMEN

AIMS: Carpal tunnel syndrome (CTS) is the most common peripheral neuropathy of the upper extremity. Surgical decompression through a limited open palmar incision is still the most widely used treatment. The aim of this study was to compare two different incision surgical techniques for carpal tunnel surgery. PATIENTS AND METHODS: In this retrospective study, 41 patient hands (transverse surgery) were compared with 55 controls (longitudinal surgery) using, as validated outcome instruments, the "Boston Carpal Tunnel Questionnaire" for postoperative effectiveness to measure symptoms, disability and health-related quality of life. The patients were monitored just before the CTS surgery and then 4 weeks and 3 months after surgery. RESULTS: Complications resulted few and comparable for both techniques. Results showed similar outcomes in both procedures regarding symptoms release and function, except for one month results where function was better for the transverse incision (p<0.01) which required reduced time, anyway. CONCLUSIONS: The transverse incision technique proved a suitable optimal solution for carpal tunnel release. This technique, therefore, induces to a better tolerated scar at short term follow up, compared to a standard palmar longitudinal incision.


Asunto(s)
Síndrome del Túnel Carpiano/cirugía , Descompresión Quirúrgica/métodos , Humanos , Calidad de Vida , Estudios Retrospectivos
17.
Opt Express ; 23(26): 32888-96, 2015 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-26831956

RESUMEN

We exploit the speckle field generated by scattering from a colloidal suspension to access both spatial and temporal coherence properties of broadband radiation. By applying the Wiener-Khinchine theorem to the retrieved temporal coherence function, information about the emission spectrum of the source is obtained in good agreement with the results of a grating spectrometer. Experiments have been performed with visible light. We prove more generally that our approach can be considered as a tool for modeling a variety of cases. Here we discuss how to apply such diagnostics to broad-spectrum betatron radiation produced in the laser-driven wakefield accelerator under development at SPARC LAB facility in Frascati.

18.
Rev Sci Instrum ; 84(4): 043704, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23635200

RESUMEN

Microgravity research in space is a complex activity where the often scarce resources available for the launch, accommodation, and operation of instrumentation call for a careful experiment planning and instrument development. In this paper we describe a module of the Selectable Optical Diagnostic Instrument, that has been designed as a compact optical diagnostic instrument for colloidal physics experiments. The peculiarity of the instrument is the combination of a novel light scattering technique known as near field scattering and standard microscopy with a low-coherence laser light source. We describe its main design features, as well as measurement results on colloidal aggregation taken on the International Space Station.

19.
Rev Sci Instrum ; 83(10): 104704, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126787

RESUMEN

An original low-noise large dynamic-range readout system for optical light spectroscopy with PIN diodes is presented. The front-end circuit is equipped with a smart device for automatic cancellation of the large dc offset brought about by the photodiode current. This device sinks away the exact amount of dc current from the preamplifier input, yielding auto zeroing of the output-voltage offset, while introducing the minimum electronic noise possible. As a result the measurement dynamic-range is maximized. Moreover, an auxiliary inspection point is provided which precisely tracks the dc component of the photodiode current. This output allows for precise beam alignment and may also be used for diagnostic purposes. The excellent gain stability and linearity make the circuit perfectly suited for optical-light pulse spectroscopy. Applications include particle sizing in the 100 nm range, two-dimensional characterization of semiconductor detectors, ultra-precise characterization of laser beam stability, confocal microscopy.

20.
Neurogastroenterol Motil ; 24(1): e56-66, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21995307

RESUMEN

BACKGROUND: Thiazolidinediones (TZDs) including rosiglitazone (ROSI) are insulin sensitizing agents with beneficial gastrointestinal effects. However, no studies are available on TZDs effect in gastrointestinal motility. We evaluated the effects of ROSI on gastrointestinal inhibitory neurotransmission focusing on the modulatory roles of nitric oxide synthase/nitric oxide (NOS/NO) and heme oxygenase/carbon monoxide (HO/CO) pathways. METHODS: Spontaneously hypertensive rats (SHR) were used as model of insulin resistance. Duodenal strips were obtained from vehicle-treated SHR, ROSI-treated SHR (5 mg kg(-1) by gavage daily per 6 weeks), and Wistar Kyoto (WKY). Inhibitory responses to electrical field stimulation (EFS) were evaluated in the presence of HO inhibitor zinc protoporphyrin IX (ZnPPIX, 10 µmol L(-1)) or NOS inhibitor N(G)-nitro-L-arginine (L-NNA, 100 µmol L(-1)), alone and in combination. Protein levels of HO and NOS isoforms were evaluated by immunohistochemistry and western blot analysis. KEY RESULTS: Basal responses to EFS were significantly increased in duodenum strips from vehicle-treated SHR vs WKY. This effect was reversed in ROSI-treated SHR. The EFS-mediated relaxation was comparably reduced by ZnPPIX in WKY and SHR, but not in ROSI-treated SHR animals. The L-NNA reduced EFS response to a similar extent in WKY and ROSI -treated SHR, but its effect was significantly higher in vehicle-treated SHR. Expression of HO-1 protein was significantly lower, whereas HO-2 protein levels were unchanged in ROSI-treated SHR with respect to vehicle-treated SHR. Finally, increased levels of nNOS in vehicle-treated SHR were reduced in ROSI-treated SHR. CONCLUSIONS & INFERENCES: Chronic ROSI treatment reverses increased SHR duodenal inhibitory response acting on CO and NO components.


Asunto(s)
Duodeno/efectos de los fármacos , Duodeno/fisiología , Motilidad Gastrointestinal/efectos de los fármacos , Hipoglucemiantes/farmacología , Transmisión Sináptica/efectos de los fármacos , Tiazolidinedionas/farmacología , Animales , Monóxido de Carbono/metabolismo , Motilidad Gastrointestinal/fisiología , Hemo Oxigenasa (Desciclizante)/metabolismo , Isoenzimas/metabolismo , Masculino , Óxido Nítrico/metabolismo , Óxido Nítrico Sintasa/antagonistas & inhibidores , Óxido Nítrico Sintasa/metabolismo , Protoporfirinas/farmacología , Ratas , Ratas Endogámicas SHR , Ratas Endogámicas WKY , Rosiglitazona , Transmisión Sináptica/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA