2.
J Am Coll Cardiol ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38759907

RESUMEN

BACKGROUND: ILUMIEN IV was the first large-scale, multicenter, randomized trial comparing optical coherence tomography (OCT)-guided versus angiography-guided stent implantation in patients with high-risk clinical characteristics and/or complex angiographic lesions. OBJECTIVE: Here, we aimed to specifically examine outcomes in the complex angiographic lesions subgroup. METHODS: From the original trial population (n=2487), high-risk patients without complex angiographic lesions were excluded (n=514). Complex angiographic lesion characteristics included 1) long or multiple lesions with intended total stent length ≥28 mm; 2) bifurcation lesion with intended two-stent strategy; 3) severely calcified lesion; 4) chronic total occlusion; or 5) in-stent restenosis. The study endpoints were 1) final minimal stent area (MSA); 2) 2-year composite of serious major adverse cardiovascular events (MACE; cardiac death, target-vessel myocardial infarction (MI), or stent thrombosis); and 3) 2-year effectiveness, defined as target-vessel failure (TVF), a composite of cardiac death, target-vessel MI, or ischemia-driven target-vessel revascularization. RESULTS: The post-PCI MSA was larger in the OCT- (n=992) versus angiography-guided (n=981) group (5.56±1.95 versus 5.26±1.81mm2; difference, 0.30; 95% confidence interval [CI], 0.14-0.47; P<0.001). Compared with angiography-guided PCI, OCT-guided PCI resulted in a lower risk of serious MACE (3.1% versus 4.9%; hazard ratio [HR], 0.63; 95% CI, 0.40-0.99; P=0.04). TVF was not significantly different between groups (7.3% versus 8.8%; HR, 0.82; 95% CI, 0.59-1.12; P=0.20). CONCLUSIONS: In complex angiographic lesions, OCT-guided PCI led to a larger MSA and reduced the serious MACE composite of cardiac death, target-vessel MI, or stent thrombosis compared with angiography-guided PCI at 2 years, but did not significantly improve TVF.

3.
JAMA Cardiol ; 9(6): 507-522, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38630494

RESUMEN

Importance: Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status. Objective: To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status. Design, Setting, and Participants: This was a sham-controlled randomized clinical trial of an atrial shunt device in heart failure with preserved ejection fraction (HFpEF)/HF with mildly reduced EF (HFmrEF). Trial participants with evaluable echocardiography scans were recruited from 89 international medical centers. Data were analyzed from April 2023 to January 2024. Interventions: Atrial shunt device or sham control. Main Outcome Measures: Changes in echocardiographic measures from baseline to 1, 6, 12, and 24 months after index procedure. Results: The modified intention-to-treat analysis of the REDUCE LAP-HF II trial included 621 randomized patients (median [IQR] age, 72.0 [66.0-77.0] years; 382 female [61.5%]; shunt arm, 309 [49.8%]; sham control arm, 312 [50.2%]). Through 24 months, 212 of 217 patients (98%) in the shunt arm with evaluable echocardiograms had patent shunts. In the overall trial population, the shunt reduced left ventricular (LV) end-diastolic volume (mean difference, -5.65 mL; P <.001), left atrial (LA) minimal volume (mean difference, -2.8 mL; P =.01), and improved LV systolic tissue Doppler velocity (mean difference, 0.69 cm/s; P <.001) and LA emptying fraction (mean difference, 1.88 percentage units; P =.02) compared with sham. Shunt treatment also increased right ventricular (RV; mean difference, 9.58 mL; P <.001) and right atrial (RA; mean difference, 9.71 mL; P <.001) volumes but had no effect on RV systolic function, pulmonary artery pressure, or RA pressure compared with sham. In the shunt arm, responders had smaller increases in RV end-diastolic volume (mean difference, 5.71 mL vs 15.18 mL; interaction P =.01), RV end-systolic volume (mean difference, 1.58 mL vs 7.89 mL; interaction P =.002), and RV/LV ratio (mean difference, 0.07 vs 0.20; interaction P <.001) and larger increases in transmitral A wave velocity (mean difference, 5.08 cm/s vs -1.97 cm/s; interaction P =.02) compared with nonresponders randomized to the shunt, suggesting greater ability to accommodate shunted blood through the pulmonary circulation enabling LA unloading. Conclusions and Relevance: In this post hoc analysis of the REDUCE LAP-HF II trial, over 2 years of follow-up, atrial shunting led to reverse remodeling of left-sided chambers and increases in volume of right-sided chambers consistent with the shunt flow but no change in RV systolic function compared with sham. Changes in cardiac structure/function were more favorable in responders compared with nonresponders treated with the shunt, supporting the previously identified responder group hypothesis and mechanism, although further evaluation with longer follow-up is needed. Trial Registration: ClinicalTrials.gov Identifier: NCT03088033.


Asunto(s)
Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Femenino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Masculino , Volumen Sistólico/fisiología , Anciano , Persona de Mediana Edad , Ecocardiografía , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Resultado del Tratamiento
4.
J Card Fail ; 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38211934

RESUMEN

OBJECTIVE: Splanchnic vasoconstriction augments transfer of blood volume from the abdomen into the thorax, which may increase filling pressures and hemodynamic congestion in patients with noncompliant hearts. Therapeutic interruption of splanchnic nerve activity holds promise to reduce hemodynamic congestion in patients with heart failure with preserved ejection fraction (HFpEF). Here we describe (1) the rationale and design of the first sham-controlled, randomized clinical trial of splanchnic nerve ablation for HFpEF and (2) the 12-month results of the lead-in (open-label) trial's participants. METHODS: REBALANCE-HF is a prospective, multicenter, randomized, double-blinded, sham-controlled clinical trial of endovascular, transcatheter, right-sided greater splanchnic nerve ablation for volume management (SAVM) in patients with HFpEF. The primary objectives are to evaluate the safety and efficacy of SAVM and identify responder characteristics to inform future studies. The trial consists of an open-label lead-in phase followed by the randomized, sham-controlled phase. The primary efficacy endpoint is the reduction in pulmonary capillary wedge pressure (PCWP) at 1-month follow-up compared to baseline during passive leg raise and 20W exercise. Secondary and exploratory endpoints include health status (Kansas City Cardiomyopathy Questionnaire), 6-minute walk test distance, New York Heart Association class, and NTproBNP levels at 3, 6 and 12 months. The primary safety endpoint is device- or procedure-related serious adverse events at the 1-month follow-up. RESULTS: The lead-in phase of the study, which enrolled 26 patients with HFpEF who underwent SAVM, demonstrated favorable safety outcomes and reduction in exercise PCWP at 1 month post-procedure and improvements in all secondary endpoints at 6 and 12 months of follow-up. The randomized phase of the trial (n = 44 SAVM; n = 46 sham) has completed enrollment, and follow-up is ongoing. CONCLUSION: REBALANCE-HF is the first sham-controlled randomized clinical trial of greater splanchnic nerve ablation in HFpEF. Initial 12-month open-label results are promising, and the results of the randomized portion of the trial will inform the design of a future pivotal clinical trial. SAVM may offer a promising therapeutic option for patients with HFpEF. TRIAL REGISTRATION: NCT04592445.

5.
Cardiovasc Revasc Med ; 58: 60-67, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37550123

RESUMEN

BACKGROUND: Patients with high bleeding risk (HBR) are often treated with abbreviated dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) to reduce bleeding risk, however this strategy is associated with an increase in ischemic events, especially if the acute PCI result is suboptimal. We compared clinical outcomes among patients with HBR treated with 1-month DAPT who underwent intravascular ultrasound (IVUS)- or optical coherence tomography (OCT)-guided PCI versus those who underwent angiography-guided PCI without intravascular imaging. METHODS: The Onyx ONE Clear study includes patients with HBR from the Onyx ONE US/Japan and Onyx ONE randomized studies who were treated with the Resolute Onyx zotarolimus-eluting stent. The primary endpoint was the composite of cardiac death (CD) or myocardial infarction (MI) between 1 month and 2 years after PCI. Propensity-score adjustments and matching were performed for differences in baseline and procedural characteristics between groups. RESULTS: Among the 1507 patients in Onyx ONE Clear, 271 (18.0 %) had IVUS or OCT used during PCI (Imaging-guided group) and 1236 (82.0 %) underwent Angiography-guided PCI (Angio-guided group). Imaging-guided patients were less likely to present with atrial fibrillation, acute coronary syndrome, and left ventricle ejection fraction ≤35 %. Conversely, Imaging-guided patients were more likely to have complex (ACC/AHA type B2/C), longer, and heavily calcified lesions. Between 1 month and 2 years, the composite rate of CD or MI was similar between Imaging-guided and Angio-guided patients (9.9 % vs. 12.4 %, P = 0.33). There was also no difference between groups after adjustment; (P = 0.56). However, CD was significantly lower among Imaging-guided patients (2.7 % vs. 6.1 %, P = 0.048). There were no between-group differences in MI or stent thrombosis. Propensity score matching results were similar. CONCLUSION: Despite higher lesion complexity, using intravascular imaging guidance for PCI between 1-month and 2-years follow-up had comparable outcomes with angiographic guidance alone in patients with HBR treated with 1-month DAPT. (ClinicalTrials.gov: Identifier: NCT03647475 and NCT03344653). NON-STANDARD ABBREVIATIONS AND ACRONYMS: BARC: Bleeding Academic Research Consortium; DAPT: dual antiplatelet therapy; DES: drug-eluting stent; HBR: high bleeding risk; IVUS: intravascular ultrasound; OCT: optical coherence tomography; SAPT: single antiplatelet therapy.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Stents Liberadores de Fármacos/efectos adversos , Infarto del Miocardio/terapia , Infarto del Miocardio/tratamiento farmacológico , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/efectos adversos , Resultado del Tratamiento , Estudios Prospectivos
6.
Artículo en Inglés | MEDLINE | ID: mdl-37962288

RESUMEN

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

7.
JACC Cardiovasc Interv ; 16(22): 2708-2718, 2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-37943200

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) is an approved alternative for stroke prevention in atrial fibrillation for patients with an "appropriate rationale" to avoid long-term oral anticoagulation (OAC). Many patients undergoing LAAO are at high risk of bleeding. OBJECTIVES: This study sought to investigate whether dual antiplatelet therapy (DAPT) is a safe alternative to OAC (direct oral anticoagulation [DOAC] or warfarin) with aspirin after LAAO. METHODS: Using National Cardiovascular Data Registry LAAO registry data, patients undergoing Watchman FLX (Boston Scientific) implantation (August 5, 2020-September 30, 2021) were included in 1:1 propensity-matched analyses comparing discharge medication regimens (DAPT, DOAC/aspirin, or warfarin/aspirin). A composite endpoint (death, stroke, major bleeding, and systemic embolism), its components, and device-related thrombus between discharge and 45 days were evaluated. RESULTS: In 49,968 patients implanted with the Watchman FLX during the study period, the mean age was 77 years, and 40% were women. Postimplant DOAC/aspirin was prescribed in 24,497 patients, warfarin/aspirin in 3,913, and DAPT in 4,155. DAPT patients had more comorbid conditions than patients receiving OAC/aspirin. After propensity score matching, the 45-day composite endpoint rates were similar among the groups (DAPT = 3.44% vs DOAC/aspirin: 4.06%; P = 0.13 and DAPT = 3.23% vs warfarin/aspirin: 3.08%; P = 0.75). Death, stroke, and device-related thrombus were also similar; major bleeding was slightly increased in DOAC/aspirin patients (DAPT = 2.48% vs DOAC/aspirin = 3.25%; P = 0.04 and DAPT = 2.25% vs warfarin/aspirin = 2.22%; P = 0.93). CONCLUSIONS: In a large registry, DAPT had a similar safety profile compared with current Food and Drug Administration-approved postimplant drug regimens of OAC with aspirin following LAAO with the Watchman FLX. Shared decision making for nonpharmacologic stroke prevention should include a discussion of postprocedure medical therapy options.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Humanos , Femenino , Anciano , Masculino , Warfarina/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Anticoagulantes/efectos adversos , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Hemorragia/inducido químicamente , Aspirina/efectos adversos , Trombosis/tratamiento farmacológico , Sistema de Registros
9.
JACC Clin Electrophysiol ; 9(12): 2587-2599, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37831030

RESUMEN

BACKGROUND: Intraprocedural imaging is critical for device delivery in transcatheter left atrial appendage occlusion (LAAO). Although pivotal trials of LAAO devices were conducted using transesophageal echocardiography (TEE), intracardiac echocardiography (ICE) is an emerging imaging modality. OBJECTIVES: This study compared outcomes after ICE- and TEE-guided Watchman FLX implantation in the SURPASS (SURveillance Post Approval AnalySiS Plan) nationwide LAAO registry. METHODS: Baseline characteristics were compared using chi-square and t-tests. Outcomes were reported in unadjusted and adjusted comparisons via propensity weighting. RESULTS: Between August 2020 and September 2021, LAAO was attempted in 39,759 patients at 698 sites, including 2,272 cases (5.7%) with ICE and 31,835 (80.0%) with TEE. ICE and TEE patients had similar baseline characteristics and mean procedural times (ICE 82 minutes vs TEE 78 minutes). ICE patients were less likely to receive general anesthesia (54% vs 98%, P < 0.01). Successful device implantation (98.3% vs 97.6%) and complete seal rates at 45 days were similar (n = 25,280; 83% vs 82%). Most adverse event rates were similar; unadjusted mortality rates at 45 days were 1.1% for ICE vs 0.8% for TEE (P = 0.14), and 1.0% vs 0.7% (P = 0.27) in adjusted analyses. Even after adjustment, pericardial effusion rates requiring intervention were significantly higher with ICE at 45 days (1.0% vs 0.5%; P = 0.02). This rate decreased as operators performed more ICE-guided procedures, although 82% of operators had performed <10 ICE-guided procedures overall. CONCLUSIONS: In the largest comparison to date, ICE use was infrequent. ICE and TEE both achieved high rates of complete LAAO. ICE was associated with significantly higher rates of pericardial effusion requiring intervention.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Derrame Pericárdico , Humanos , Ecocardiografía Transesofágica , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Derrame Pericárdico/etiología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/métodos
10.
Am J Cardiol ; 208: 118-123, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37832208

RESUMEN

Transcatheter patent foramen ovale (PFO) closure is indicated for patients with cryptogenic stroke. Although procedural safety is well established, there are limited data on the safety of same-day (SD) discharge. We aimed to review the outcomes of PFO closure with SD. Patients who underwent transcatheter PFO closure between January 2011 and May 2022 at 4 large US hospitals were retrospectively analyzed, comparing outcomes of SD versus delayed discharge (DD). The primary end point was a composite of access-site complication, stroke, device embolization, atrial arrhythmia, and bleeding. Secondary analysis comparing imaging modality and outcomes was performed. 554 patients (49.2% female) were analyzed (382 discharged SD). Average age was 54.3 ± 15. Baseline characteristics in both groups were broadly similar. Previous stroke (78.0% SD vs 76.2% DD, p = 0.32) was the commonest indication for PFO closure. In the SD group, there was less general anesthesia use (5.5% vs 16.9%, p <0.001). Intraprocedural intracardiac echocardiography was used more frequently in SD cases (95.0% vs 81.4%, p <0.001). In the DD group, median stay was 1 night, and 34.9% stayed beyond 1 night. At 30 days, there was no difference in the primary composite end point (14.9% vs 11.6%, p = 0.15). There was no inter-group difference in individual adverse events (all p >0.05). When comparing imaging modality and outcomes, there was no difference in composite end points between transesophageal and intracardiac echocardiography (6.5% vs 14.7%, p = 0.063). In conclusion, SD discharge after transcatheter PFO closure appears safe. This efficient approach may be advantageous in optimizing workflow and minimizing hospital occupancy.


Asunto(s)
Foramen Oval Permeable , Accidente Cerebrovascular , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cateterismo Cardíaco/métodos , Foramen Oval Permeable/cirugía , Foramen Oval Permeable/complicaciones , Estudios Multicéntricos como Asunto , Recurrencia Local de Neoplasia/complicaciones , Alta del Paciente , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/complicaciones , Resultado del Tratamiento
11.
JACC Cardiovasc Interv ; 16(21): 2600-2610, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37877913

RESUMEN

BACKGROUND: The fourth-generation mitral transcatheter edge-to-edge repair (M-TEER) device introduced an improved clip deployment sequence, independent leaflet grasping, and 2 wider clip sizes to tailor the treatment of patients with mitral regurgitation (MR) for a broad range of anatomies. The 30-day safety and effectiveness of the fourth-generation M-TEER device were previously demonstrated. OBJECTIVES: The aim of this study was to evaluate 1-year outcomes in a contemporary, real-world cohort of subjects treated with the MitraClip G4 system. METHODS: EXPAND G4 is an ongoing prospective, multicenter, international, single-arm study that enrolled subjects with primary and secondary MR. One-year outcomes included MR severity (echocardiographic core laboratory assessed), heart failure hospitalization, all-cause mortality, functional capacity (NYHA functional class), and quality of life (Kansas City Cardiomyopathy Questionnaire). RESULTS: A total of 1,164 subjects underwent M-TEER from 2020 to 2022. At 1 year, there was a durable reduction in MR to mild or less in 92.6% and to none or trace in 44.2% (P < 0.0001 vs baseline). Few subjects had major adverse events through 1 year (<2% for myocardial infarction, surgical reintervention, or single-leaflet device attachment). The 1-year Kaplan-Meier estimates for all-cause mortality and heart failure hospitalization were 12.3% and 16.9%. Significant improvements in functional capacity (NYHA functional class I or II in 82%; P < 0.0001 vs baseline) and quality of life (18.5-point Kansas City Cardiomyopathy Questionnaire overall summary score improvement; P < 0.0001) were observed. CONCLUSIONS: M-TEER with the fourth-generation M-TEER device was safe and effective at 1 year, with durable reductions in MR severity to ≤1+ in more than 90% of patients and concomitant improvements in functional status and quality of life.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Calidad de Vida , Estudios Prospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
13.
N Engl J Med ; 389(16): 1466-1476, 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37634188

RESUMEN

BACKGROUND: Data regarding clinical outcomes after optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI) as compared with angiography-guided PCI are limited. METHODS: In this prospective, randomized, single-blind trial, we randomly assigned patients with medication-treated diabetes or complex coronary-artery lesions to undergo OCT-guided PCI or angiography-guided PCI. A final blinded OCT procedure was performed in patients in the angiography group. The two primary efficacy end points were the minimum stent area after PCI as assessed with OCT and target-vessel failure at 2 years, defined as a composite of death from cardiac causes, target-vessel myocardial infarction, or ischemia-driven target-vessel revascularization. Safety was also assessed. RESULTS: The trial was conducted at 80 sites in 18 countries. A total of 2487 patients underwent randomization: 1233 patients were assigned to undergo OCT-guided PCI, and 1254 to undergo angiography-guided PCI. The minimum stent area after PCI was 5.72±2.04 mm2 in the OCT group and 5.36±1.87 mm2 in the angiography group (mean difference, 0.36 mm2; 95% confidence interval [CI], 0.21 to 0.51; P<0.001). Target-vessel failure within 2 years occurred in 88 patients in the OCT group and in 99 patients in the angiography group (Kaplan-Meier estimates, 7.4% and 8.2%, respectively; hazard ratio, 0.90; 95% CI, 0.67 to 1.19; P = 0.45). OCT-related adverse events occurred in 1 patient in the OCT group and in 2 patients in the angiography group. Stent thrombosis within 2 years occurred in 6 patients (0.5%) in the OCT group and in 17 patients (1.4%) in the angiography group. CONCLUSIONS: Among patients undergoing PCI, OCT guidance resulted in a larger minimum stent area than angiography guidance, but there was no apparent between-group difference in the percentage of patients with target-vessel failure at 2 years. (Funded by Abbott; ILUMIEN IV: OPTIMAL PCI ClinicalTrials.gov number, NCT03507777.).


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Tomografía de Coherencia Óptica , Humanos , Angiografía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Método Simple Ciego , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Diabetes Mellitus , Implantación de Prótesis Vascular/métodos , Stents
14.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37584233

RESUMEN

AIMS: Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanistic factors impacting differences in PDLs within the Amulet IDE trial are assessed in the current analysis. METHODS AND RESULTS: An independent core lab analysed all images for the presence or absence of severe PDL (>5 mm). The incidence, mechanistic factors, predictors using propensity score-matched controls, and evolution of severe PDLs through 18 months were assessed. Of the 1878 patients randomized in the trial, the Amulet occluder had significantly fewer severe PDLs than the Watchman device at 45 days (1.1 vs. 3.2%, P < 0.001) and 12 months (0.1 vs. 1.1%, P < 0.001). Off-axis deployment or missed lobes were leading mechanistic PDL factors in each device group. Larger left atrial appendage (LAA) dimensions including orifice diameter, landing zone diameter, and depth predicted severe PDL with the Watchman device, with no significant anatomical limitations noted with the Amulet occluder. Procedural and device implant predictors were found with the Amulet occluder attributed to the learning curve with the device. A majority of Watchman device severe PDLs did not resolve over time through 18 months. CONCLUSION: The dual-occlusive Amplatzer Amulet LAA occluder provided improved LAA closure compared with the Watchman 2.5 device. Predictors and temporal observations of severe PDLs were identified in the Amulet IDE trial. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov Unique identifier NCT02879448.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento , Dispositivo Oclusor Septal/efectos adversos , Cateterismo Cardíaco/efectos adversos , Accidente Cerebrovascular/etiología
15.
JACC Cardiovasc Interv ; 16(12): 1463-1473, 2023 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-37380228

RESUMEN

BACKGROUND: The fourth-generation MitraClip G4 System builds on the previous NTR/XTR system with additional wider clip sizes (NTW and XTW), an independent grasping feature, and an improved clip deployment sequence. OBJECTIVES: The primary objective of this study was to assess the safety and performance of the MitraClip G4 System within a contemporary real-world setting. METHODS: EXPAND G4 is a prospective, multicenter, international, single-arm, postapproval study that enrolled patients with primary (degenerative) mitral regurgitation (MR) and secondary (functional) MR at 60 centers. Follow-up of the full cohort has been conducted through 30 days. Echocardiograms were analyzed by an echocardiography core laboratory. Study outcomes included MR severity, functional capacity measured by NYHA functional class, quality of life measured using the Kansas City Cardiomyopathy Questionnaire, major adverse event rates, and all-cause mortality. RESULTS: In EXPAND G4, 1,141 subjects with primary MR and secondary MR were treated from March 2021 to February 2022. Implantation and acute procedural success rates were 98.0% and 96.2%, respectively, with a mean of 1.4 ± 0.6 clips implanted per subject. MR was significantly reduced at 30 days compared with baseline (98% achieved MR ≤ 2+, and 91% achieved MR ≤ 1+; P < 0.0001). Functional capacity and quality of life were substantially improved, with 83% of patients achieving NYHA functional class I or II. Likewise, an 18-point improvement was observed in Kansas City Cardiomyopathy Questionnaire summary scores compared with baseline. The composite major adverse event rate was 2.7%, and the all-cause death rate was 1.3% at 30 days. CONCLUSIONS: This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting.


Asunto(s)
Cardiomiopatías , Insuficiencia de la Válvula Mitral , Humanos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Ecocardiografía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
16.
JACC Cardiovasc Interv ; 16(12): 1474-1485, 2023 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-37380229

RESUMEN

BACKGROUND: Anatomical and clinical criteria to define mitral transcatheter edge-to-edge repair (TEER) "unsuitability" have been proposed on the basis of a Heart Valve Collaboratory consensus opinion from physician experience with early-generation TEER devices but lacked an evidence-based approach. OBJECTIVES: The aim of this study was to explore the spectrum of TEER suitability using echocardiographic and clinical outcomes from the EXPAND G4 real-world postapproval study. METHODS: EXPAND G4 is a global, prospective, multicenter, single-arm study that enrolled 1,164 subjects with mitral regurgitation (MR) treated with the MitraClip G4 System. Three groups were defined using the Heart Valve Collaboratory TEER unsuitability criteria: 1) risk of stenosis (RoS); 2) risk of inadequate MR reduction (RoIR); and 3) subjects with baseline moderate or less MR (MMR). A TEER-suitable (TS) group was defined by the absence of these characteristics. Endpoints included independent core laboratory-assessed echocardiographic characteristics, procedural outcomes, MR reduction, NYHA functional class, Kansas City Cardiomyopathy Questionnaire score, and major adverse events through 30 days. RESULTS: Subjects in the RoS (n = 56), RoIR (n = 54), MMR (n = 326), and TS (n = 303) groups had high 30-day MR reduction rates (≤1+: RoS 97%, MMR 93%, and TS 91%; ≤2+: RoIR 94%). Thirty-day improvements in functional capacity (NYHA functional class I or II at 30 days vs baseline: RoS 94% vs 29%, RoIR 88% vs 30%, MMR 79% vs 26%, and TS 83% vs 33%) and quality of life (change in Kansas City Cardiomyopathy Questionnaire score: RoS +27 ± 26, RoIR +16 ± 26, MMR +19 ± 26, and TS +19 ± 24) were safely achieved in all groups, with low major adverse events (<3%) and all-cause mortality (RoS 1.8%, RoIR 0%, MMR 1.5%, and TS 1.3%). CONCLUSIONS: Patients previously deemed TEER unsuitable can be safely and effectively treated with the mitral TEER fourth-generation device.


Asunto(s)
Cardiomiopatías , Insuficiencia de la Válvula Mitral , Humanos , Estudios Prospectivos , Calidad de Vida , Especies Reactivas de Oxígeno , Resultado del Tratamiento , Constricción Patológica , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
17.
N Engl J Med ; 388(20): 1833-1842, 2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-36876753

RESUMEN

BACKGROUND: Severe tricuspid regurgitation is a debilitating condition that is associated with substantial morbidity and often with poor quality of life. Decreasing tricuspid regurgitation may reduce symptoms and improve clinical outcomes in patients with this disease. METHODS: We conducted a prospective randomized trial of percutaneous tricuspid transcatheter edge-to-edge repair (TEER) for severe tricuspid regurgitation. Patients with symptomatic severe tricuspid regurgitation were enrolled at 65 centers in the United States, Canada, and Europe and were randomly assigned in a 1:1 ratio to receive either TEER or medical therapy (control). The primary end point was a hierarchical composite that included death from any cause or tricuspid-valve surgery; hospitalization for heart failure; and an improvement in quality of life as measured with the Kansas City Cardiomyopathy Questionnaire (KCCQ), with an improvement defined as an increase of at least 15 points in the KCCQ score (range, 0 to 100, with higher scores indicating better quality of life) at the 1-year follow-up. The severity of tricuspid regurgitation and safety were also assessed. RESULTS: A total of 350 patients were enrolled; 175 were assigned to each group. The mean age of the patients was 78 years, and 54.9% were women. The results for the primary end point favored the TEER group (win ratio, 1.48; 95% confidence interval, 1.06 to 2.13; P = 0.02). The incidence of death or tricuspid-valve surgery and the rate of hospitalization for heart failure did not appear to differ between the groups. The KCCQ quality-of-life score changed by a mean (±SD) of 12.3±1.8 points in the TEER group, as compared with 0.6±1.8 points in the control group (P<0.001). At 30 days, 87.0% of the patients in the TEER group and 4.8% of those in the control group had tricuspid regurgitation of no greater than moderate severity (P<0.001). TEER was found to be safe; 98.3% of the patients who underwent the procedure were free from major adverse events at 30 days. CONCLUSIONS: Tricuspid TEER was safe for patients with severe tricuspid regurgitation, reduced the severity of tricuspid regurgitation, and was associated with an improvement in quality of life. (Funded by Abbott; TRILUMINATE Pivotal ClinicalTrials.gov number, NCT03904147.).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Femenino , Humanos , Masculino , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/cirugía
18.
JACC Cardiovasc Interv ; 16(11): 1384-1400, 2023 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-36990858

RESUMEN

Exclusion of the left atrial appendage to reduce thromboembolic risk related to atrial fibrillation was first performed surgically in 1949. Over the past 2 decades, the field of transcatheter endovascular left atrial appendage closure (LAAC) has rapidly expanded, with a myriad of devices approved or in clinical development. The number of LAAC procedures performed in the United States and worldwide has increased exponentially since the Food and Drug Administration approval of the WATCHMAN (Boston Scientific) device in 2015. The Society for Cardiovascular Angiography & Interventions (SCAI) has previously published statements in 2015 and 2016 providing societal overview of the technology and institutional and operator requirements for LAAC. Since then, results from several important clinical trials and registries have been published, technical expertise and clinical practice have matured over time, and the device and imaging technologies have evolved. Therefore, SCAI prioritized the development of an updated consensus statement to provide recommendations on contemporary, evidence-based best practices for transcatheter LAAC focusing on endovascular devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Angiografía
19.
Heart Rhythm ; 20(5): e1-e16, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36990925

RESUMEN

Exclusion of the left atrial appendage to reduce thromboembolic risk related to atrial fibrillation was first performed surgically in 1949. Over the past 2 decades, the field of transcatheter endovascular left atrial appendage closure (LAAC) has rapidly expanded, with a myriad of devices approved or in clinical development. The number of LAAC procedures performed in the United States and worldwide has increased exponentially since the Food and Drug Administration approval of the WATCHMAN (Boston Scientific) device in 2015. The Society for Cardiovascular Angiography & Interventions (SCAI) has previously published statements in 2015 and 2016 providing societal overview of the technology and institutional and operator requirements for LAAC. Since then, results from several important clinical trials and registries have been published, technical expertise and clinical practice have matured over time, and the device and imaging technologies have evolved. Therefore, SCAI prioritized the development of an updated consensus statement to provide recommendations on contemporary, evidence-based best practices for transcatheter LAAC focusing on endovascular devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Angiografía , Resultado del Tratamiento
20.
JACC Cardiovasc Interv ; 16(5): 589-602, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36922046

RESUMEN

BACKGROUND: The third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system was introduced to assist in leaflet grasping with the longer clip arms of MitraClip XTR and to improve ease of use with the modified delivery catheter. OBJECTIVES: The EXPAND study evaluated contemporary real-world outcomes in subjects with mitral regurgitation (MR) treated with the third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system. METHODS: EXPAND is a prospective, multicenter, international, single-arm study that enrolled patients with primary MR and secondary MR at 57 centers. Follow-up was conducted through 12 months. Echocardiograms were analyzed by an echocardiographic core laboratories. Study outcomes included: MR severity, functional capacity measured by New York Heart Association functional class, quality of life measured by Kansas City Cardiomyopathy Questionnaire, heart failure hospitalizations, all-cause mortality. RESULTS: 1,041 patients were enrolled from April 2018 through March 2019, of which 50.5% had primary or mixed etiology. Implant success was 98.9%; 1.5 ± 0.6 clips were implanted per subject. Significant MR reduction from baseline (≥MR 3+: 56.0%) to 30 days (≤MR 1+:88.8%) was maintained through 1 year (MR ≤1+: 89.2%). A total of 84.5% and 93.0% of subjects in primary MR and secondary MR, respectively, had ≤1+ MR at 1 year. Significant improvements were observed in clinical outcomes (New York Heart Association functional class I/II in 80.3%, +21.6 improvement in Kansas City Cardiomyopathy Questionnaire score) at 1 year. All-cause mortality and heart failure hospitalizations at 1 year were 14.9% and 18.9%, respectively, which was significantly lower than previous studies. CONCLUSIONS: The study demonstrates treatment with the third-generation system resulted in substantial reduction of MR in a contemporary real-world practice, compared with the results of earlier EVEREST and COAPT trials.(The MitraClip® EXPAND Study of the Next Generation of MitraClip® Devices [EXPAND]; NCT03502811).


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Calidad de Vida , Estudios Prospectivos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Cateterismo Cardíaco , Cardiomiopatías/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA