Am J Cardiol ; 164: 103-110, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34819234

RESUMEN

The MacNew questionnaire is a disease-specific quality of life measure that has been used in patients with myocardial infarction and heart failure. We aimed to investigate the impact of transcatheter aortic valve implantation (TAVI) on health-related quality of life (HRQoL) using MacNew Questionnaire and identify predictors associated with a change in its score. This was a prospective multi-center study performed across 5 National Health Service hospitals in the United Kingdom performing TAVI between 2016 and 2018. HRQoL was assessed using MacNew Questionnaire, Euro Quality of Life-5D-5L, and Short Form 36 questionnaires collected at baseline, 3-, 6- and 12 months after the procedure. Out of 225 recruited patients, 19 did not have TAVI and 4 withdrew their consent, and hence 202 patients were included. HRQoL was assessed in 181, 161, and 147 patients at 3, 6, and 12 months, respectively. Using MacNew, there was a significant improvement in all domains of HRQoL as early as 3 months after TAVI which was sustained up to 12 months with improved discrimination of change in HRQoL compared with other scales. Poor mobility at baseline and history of myocardial infarction were independent predictors of reduced improvement in HRQoL at 3 months. HRQoL increased in all subgroups of patients including frail ones. In conclusion, the MacNew assessment tool performed well in a representative TAVI cohort and could be used as an alternative disease-specific method for assessing HRQoL change after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Calidad de Vida , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/fisiopatología , Comorbilidad , Femenino , Fragilidad/epidemiología , Humanos , Masculino , Limitación de la Movilidad , Infarto del Miocardio/epidemiología , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Encuestas y Cuestionarios , Resultado del Tratamiento , Reino Unido
2.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30394657

RESUMEN

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Irlanda , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido
3.
Catheter Cardiovasc Interv ; 82(4): E592-4, 2013 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-23172721

RESUMEN

We report the case of a very late erosion of an Amplatzer septal occluder (ASO) device more than 8 years after implant, presenting without signs of cardiac tamponade. To date, this case represents the longest period between ASO device implantation and clinical presentation following erosion. The overall rate of device erosion remains low, and the majority reported so far has occurred early, but clinicians should remain alert to the possibility of very late erosion in patients with ASO devices.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Dolor en el Pecho/etiología , Defectos del Tabique Interatrial/terapia , Derrame Pericárdico/etiología , Falla de Prótesis , Dispositivo Oclusor Septal , Adulto , Procedimientos Quirúrgicos Cardíacos , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/cirugía , Remoción de Dispositivos , Femenino , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/cirugía , Humanos , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/cirugía , Pericardio/trasplante , Diseño de Prótesis , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
Heart Surg Forum ; 15(1): E9-11, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22360911

RESUMEN

An 80-year-old woman with a 20-mm Medtronic Hall (tilting-disc) aortic prosthesis presented with episodes of chest pain associated with circulatory collapse and subsequent rapid spontaneous recovery. A computed tomography angiogram demonstrated no evidence of aortic dissection, pulmonary embolus, or coronary artery disease. A transthoracic echocardiogram demonstrated a well-functioning prosthetic aortic valve. After another inpatient episode, auscultation demonstrated an intermittent absence of the prosthetic second heart sound. A transesophageal echocardiography examination revealed that the aortic valve was intermittently sticking in the open position. During the emergency replacement, the existing valve was noted to have pannus and overlying thrombus, which are rare in this type of valve but can lead to dramatic circulatory collapse when present. This case demonstrates how a diagnosis of intermittent valve dysfunction can prove elusive. It is important, as part of the assessment of mechanical valves, to perform regular, careful auscultation and echocardiographic examination, with emphasis on recording in Doppler or M-mode through the valve at slow sweep speeds for a prolonged period in order to maximize the chance of diagnosing episodic valve dysfunction.


Asunto(s)
Válvula Aórtica/patología , Enfermedades de las Válvulas Cardíacas/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Choque/etiología , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Dolor en el Pecho , Ecocardiografía , Falla de Equipo , Femenino , Enfermedades de las Válvulas Cardíacas/patología , Humanos , Choque/patología , Factores de Tiempo
6.
Circ Cardiovasc Interv ; 3(2): 157-65, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20332383

RESUMEN

BACKGROUND: Neointima formation and atherosclerosis compromise long-term graft patency in aortocoronary and peripheral vein bypass grafts. We investigated the short- and long-term effects of periadventitial application of a sustained-release formulation of rapamycin on experimental pig vein grafts with similar dimensions and kinetics to human saphenous vein bypass grafts. METHODS AND RESULTS: Periadventitial application of rapamycin-eluting polyvinyl alcohol microspheres (60 microg . cm(-2)) to porcine saphenous vein-to-carotid artery interposition grafts inhibited vein graft positive and vascular smooth muscle cell proliferation in 1-week grafts. It also decreased neointima formation and wall thickening in 4-week vein grafts compared with controls. The inhibition of vein graft thickening was not sustained; however, a catch-up phenomenon was observed, and there was no therapeutic benefit evident in 12-week grafts. Increasing the dose of rapamycin to 120 microg . cm(-2) was associated with significant local toxicity manifest by high rates of graft rupture (25%), inhibition of adventitial neoangiogenesis, and a paradoxical acceleration of vein graft disease as evidenced by increased vascular smooth muscle cell proliferation. CONCLUSIONS: Local toxicity and poor long-term efficacy limits the clinical applicability of locally applied, sustained rapamycin release in vein graft disease.


Asunto(s)
Oclusión de Injerto Vascular/tratamiento farmacológico , Miocitos del Músculo Liso/efectos de los fármacos , Vena Safena/efectos de los fármacos , Sirolimus/administración & dosificación , Túnica Íntima/efectos de los fármacos , Animales , Arterias Carótidas/cirugía , Proliferación Celular/efectos de los fármacos , Puente de Arteria Coronaria , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/patología , Humanos , Microesferas , Modelos Animales , Miocitos del Músculo Liso/patología , Neovascularización Patológica , Vena Safena/patología , Vena Safena/trasplante , Sirolimus/efectos adversos , Porcinos , Trasplante Isogénico , Túnica Íntima/crecimiento & desarrollo , Túnica Íntima/patología , Túnica Íntima/trasplante