1.
Circulation ; 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38973458

RESUMEN

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for AV synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The AV synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of AV synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between AV synchrony and i2i success, posture/activity, implantation indication, AV event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean AV synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrium-to-ventricle i2i (94%) and ventricle-to-atrium i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. AV synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, AV paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated AV synchrony in 98% of evaluable beats at 3 months after implantation. AV synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.

2.
Circ Arrhythm Electrophysiol ; 16(10): e012232, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37767710

RESUMEN

BACKGROUND: The clinical utilization of leadless pacemakers (LPs) as an alternative to traditional transvenous pacemakers is likely to increase with the advent of dual-chamber LP systems. Since device retrieval to allow LP upgrade or replacement will become an important capability, the first such dual-chamber, helix-fixation LP system (Aveir DR; Abbott, Abbott Park, IL) was specifically designed to allow catheter-based retrieval. In this study, the preclinical performance and safety of retrieving chronically implanted dual-chamber LPs was evaluated. METHODS: Atrial and ventricular LPs were implanted in the right atrial appendage and right ventricular apex of 9 healthy ovine subjects. After ≈2 years, the LPs were retrieved using a dedicated transvenous retrieval catheter (Aveir Retrieval Catheter; Abbott) by snaring, docking, and unscrewing from the myocardium. Comprehensive necropsy/histopathology studies were conducted to evaluate device- and procedure-related outcomes. RESULTS: At a median of 1.9 years postimplant (range, 1.8-2.6), all 18 of 18 (100%) LPs were retrieved from 9 ovine subjects without complications. The median retrieval procedure duration for both LPs, from first-catheter-in to last-catheter-out, was 13.3 minutes (range, 2.5-36.4). Postretrieval, all right atrial, and right ventricular implant sites demonstrated minimal tissue disruption, with intact fibrous tissue limited to the distal device body. No significant device-related trauma, perforation, pericardial effusion, right heart or tricuspid valve injury, or chronic pulmonary thromboembolism were observed at necropsy. CONCLUSIONS: This preclinical study demonstrated the safe and effective retrieval of chronically implanted, helix-fixation, dual-chamber LP systems, paving the way for clinical studies of LP retrieval.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Ovinos , Animales , Lipopolisacáridos , Oveja Doméstica , Ventrículos Cardíacos , Diseño de Equipo
3.
N Engl J Med ; 388(25): 2360-2370, 2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37212442

RESUMEN

BACKGROUND: Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS: We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedure-related serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS: Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (±SD) atrial capture threshold was 0.82±0.70 V, and the mean P-wave amplitude was 3.58±1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS: The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.).


Asunto(s)
Arritmias Cardíacas , Estimulación Cardíaca Artificial , Marcapaso Artificial , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/etiología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estudios de Seguimiento , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Arritmias Cardíacas/terapia
4.
Heart Rhythm ; 20(8): 1146-1155, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37075958

RESUMEN

BACKGROUND: Dual-chamber leadless pacemakers (LPs) require robust communication between distinct right atrial (RA) and right ventricular (RV) LPs to achieve atrioventricular (AV) synchrony. OBJECTIVE: The purpose of this preclinical study was to evaluate a novel, continuous implant-to-implant (i2i™) communication methodology for maintaining AV-synchronous, dual-chamber DDD(R) pacing by the 2 LPs. METHODS: RA and RV LPs were implanted and paired in 7 ovine subjects (4 with induced complete heart block). AV synchrony (% AV intervals <300 ms) and i2i communication success (% successful i2i transmissions between LPs) were evaluated acutely and chronically. During acute testing, 12-lead electrocardiographic and LP diagnostic data were collected from 5-minute recordings, in 4 postures and 2 rhythms (AP-VP and AS-VP, or AP-VS and AS-VS) per subject. Chronic i2i performance was evaluated through 23 weeks postimplant (final i2i evaluation period: week 16-23). RESULTS: Acute AV synchrony and i2i communication success across multiple postures and rhythms were median [interquartile range] 100.0% [100.0%-100.0%] and 99.9% [99.9%-99.9%], respectively. AV synchrony and i2i success rates did not differ across postures (P = .59, P = .11) or rhythms (P = 1, P = .82). During the final i2i evaluation period, the overall i2i success was 98.9% [98.1%-99.0%]. CONCLUSION: Successful AV-synchronous, dual-chamber DDD(R) leadless pacing using a novel, continuous, wireless communication modality was demonstrated across variations in posture and rhythm in a preclinical model.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Animales , Ovinos , Estimulación Cardíaca Artificial/métodos , Lipopolisacáridos , Bloqueo Atrioventricular/terapia , Frecuencia Cardíaca
5.
Circ Arrhythm Electrophysiol ; 15(7): e010909, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35861976

RESUMEN

BACKGROUND: Leadless pacemakers (LPs) can mitigate conventional pacemaker complications related to the transvenous leads and subcutaneous pocket surrounding the pulse generator. Although single-chamber leadless pacing has been established, multichamber pacing requires wireless bidirectional communication across multiple LPs to maintain synchrony. This preclinical study demonstrates the chronic performance of implant-to-implant (i2i) communication that achieves synchronous, dual-chamber pacing with 2 LPs. METHODS: The i2i communication modality employs subthreshold electrical signals conducted between implanted LPs through the blood and myocardial tissue on a beat-by-beat basis. Right atrial and right ventricular LPs were implanted in 9 ovine subjects. The i2i transmission performance was evaluated 13 weeks after implant. RESULTS: Right atrial and right ventricular LPs were implanted successfully and without complication in 9 ovine subjects. A total of 8715±457 right atrial-to-right ventricular and right ventricular-to-right atrial transmissions were sent per hour, with a success rate of 99.2±0.9%. Of periods with i2i communication failure when DDD pacing was not possible, 97.3±1.8% were resolved within 6 s. CONCLUSIONS: For the first time, synchronized, dual-chamber pacing has been demonstrated in a chronic preclinical feasibility study by 2 leadless pacemakers using beat-to-beat, wireless communication, achieving a success rate of 99.2%.


Asunto(s)
Marcapaso Artificial , Animales , Estimulación Cardíaca Artificial , Comunicación , Diseño de Equipo , Atrios Cardíacos , Ventrículos Cardíacos , Humanos , Lipopolisacáridos , Ovinos
6.
JACC Clin Electrophysiol ; 8(6): 754-762, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35738852

RESUMEN

BACKGROUND: The RAID (Ranolazine Implantable Cardioverter-Defibrillator) randomized placebo-controlled trial showed that ranolazine treatment was associated with reduction in recurrent ventricular tachycardia (VT) requiring appropriate implantable cardioverter-defibrillator (ICD) therapy. OBJECTIVES: This study aimed to identify groups of patients in whom ranolazine treatment would result in the highest reduction of ventricular tachyarrhythmia (VTA) burden. METHODS: Andersen-Gill analyses were performed to identify variables associated with risk for VTA burden among 1,012 patients enrolled in RAID. The primary endpoint was VTA burden defined as VTA episodes requiring appropriate treatment. RESULTS: Multivariate analysis identified 7 factors associated with increased VTA burden: history of VTA, age ≥65 years, New York Heart Association functional class ≥III, QRS complex (≥130 ms), low ejection fraction (<30%), atrial fibrillation (AF), and concomitant antiarrhythmic drug (AAD) therapy. The effect of ranolazine on VTA burden was seen among patients without concomitant AAD therapy (HR [HR]: 0.68; 95% CI: 0.55-0.84; P < 0.001), whereas no effect was seen among those who are concomitantly treated with other AADs (HR: 1.33; 95% CI: 0.90-1.96; P = 0.16); P = 0.003 for interaction. In patients with cardiac resynchronization therapy (CRT) ICDs, ranolazine treatment was associated with a 36% risk reduction for VTA recurrence (HR: 0.64; 95% CI: 0.47-0.86; P < 0.001), whereas among patients with ICDs without CRT no significant effect was noted (HR: 0.94; 95% CI: 0.74-1.18; P = 0.57); P = 0.047 for interaction. CONCLUSIONS: In patients with high risk for VTA, ranolazine is effective in reducing VTA burden, with significantly greater effect in CRT-treated patients, those without AF, and those not treated with concomitant AADs. In patients already on AADs or those with AF, the addition of ranolazine did not affect VTA burden. (Ranolazine Implantable Cardioverter-Defibrillator Trial [RAID]; NCT01215253).


Asunto(s)
Desfibriladores Implantables , Ranolazina , Taquicardia Ventricular , Anciano , Humanos , Ranolazina/uso terapéutico , Taquicardia Ventricular/prevención & control
7.
J Interv Card Electrophysiol ; 64(2): 519-530, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35043250

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) improves outcomes in sinus rhythm, but the data in atrial fibrillation (AF) is limited. Atrio-ventricular junctional ablation (AVJA) has been proposed as a remedy. The objective was to test if AVJA results in LV end-systolic volume (ESV) reduction ≥ 15% from baseline to 6 months. METHODS: The trial was a prospective multicenter randomized trial in 26 patients with permanent AF who were randomized 1:1 to CRT-D with or without AVJA. RESULTS: LVESV improved similarly by at least 15% in 5/10 (50%) in the CRT-D-only arm and in 6/12 (50%) in the AVJA + CRT-D arm (OR = 1.00 [0.14, 7.21], p = 1.00). In the CRT-D-only arm, the median 6-month improvement in LVEF was 9.2%, not different from the AVJA + CRT-D arm, 8.2%. When both groups were combined, a significant increase in LVEF was observed (25.4% at baseline vs 36.2% at 6 months, p = 0.002). NYHA class from baseline to 6 months for all patients combined improved 1 class in 15 of 24 (62.5%), whereas 9 remained in the same class and 0 degraded to a worse class. CONCLUSION: In patients with permanent AF, reduced LVEF, and broad QRS who were eligible for CRT, there was insufficient evidence that AVJA improved echocardiographic or clinical outcomes; the results should be interpreted in light of a smaller than planned sample size. CRT, however, seemed to be effective in the combined study cohort overall, suggesting that CRT can be reasonably deployed in patients with AF. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02946853.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Humanos , Proyectos Piloto , Estudios Prospectivos , Resultado del Tratamiento
8.
Heart Rhythm ; 19(5): 776-781, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35066177

RESUMEN

BACKGROUND: Complications associated with transvenous pacemakers, specifically those involving the lead or subcutaneous pocket, may be avoided with leadless pacemakers (LPs). The safety and efficacy of single-chamber right ventricular LPs have been demonstrated, but their right atrium (RA) use poses new design constraints. OBJECTIVES: The purpose of this study was to evaluate the implant success, electrical performance, and safety of a novel RA LP design in benchtop and preclinical studies. METHODS: A new LP was designed with a dual-helix fixation mechanism specific to the RA anatomy. A 12-week preclinical ovine study was conducted to evaluate implant success, electrical performance, mechanical stability, and safety in vivo, with supporting benchtop measurements to quantify the mechanical forces needed for device retrieval and dislodgment. RESULTS: LPs were successfully implanted in all 10 ovine subjects with no complications. The pacing capture threshold improved significantly over time from implant to week 12 (1.1 ± 0.7 V vs 0.4 ± 0.2 V, P = .008). Sensing amplitudes and pacing impedances were stable from implant to week 12 (4.8 ± 1.8 mV vs 6.0 ± 1.9 mV, P = .160; and 393 ± 77 Ω vs 398 ± 65 Ω, P = .922, respectively). Gross pathology and microscopic histology revealed no adverse interactions and no evidence of device dislodgment or clinically significant myocardial perforation. Benchtop ex vivo porcine atrial tissue measurements revealed greater pull forces required to dislodge the LP vs transvenous active fixation lead (0.42 ± 0.18 lbf vs 0.29 ± 0.08 lbf, P = .020), and greater rotational forces required for deliberate extraction (0.28 ± 0.04 lbf vs 0.14 ± 0.07 lbf, P <.001). CONCLUSION: The novel atrial LP demonstrated successful implantation, with acceptable electrical performance, mechanical stability, and safety in a 12-week preclinical study.


Asunto(s)
Lipopolisacáridos , Marcapaso Artificial , Animales , Estimulación Cardíaca Artificial , Diseño de Equipo , Atrios Cardíacos , Humanos , Prótesis e Implantes , Ovinos , Porcinos , Resultado del Tratamiento
9.
J Am Coll Cardiol ; 72(6): 636-645, 2018 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-30071993

RESUMEN

BACKGROUND: Ventricular tachycardia (VT) and ventricular fibrillation (VF) remain a challenging problem in patients with implantable cardioverter-defibrillators (ICDs). OBJECTIVES: This study aimed to determine whether ranolazine administration decreases the likelihood of VT, VF, or death in patients with an ICD. METHODS: This was double-blind, placebo-controlled clinical trial in which high-risk ICD patients with ischemic or nonischemic cardiomyopathy were randomized to 1,000 mg ranolazine twice a day or placebo. The primary endpoint was VT or VF requiring appropriate ICD therapy or death, whichever occurred first. Pre-specified secondary endpoints included ICD shock for VT, VF, or death and recurrent VT or VF requiring ICD therapy. RESULTS: Among 1,012 ICD patients (510 randomized to ranolazine and 502 to placebo) the mean age was 64 ± 10 years and 18% were women. During 28 ± 16 months of follow-up there were 372 (37%) patients with primary endpoint, 270 (27%) patients with VT or VF, and 148 (15%) deaths. The blinded study drug was discontinued in 199 (39.6%) patients receiving placebo and in 253 (49.6%) patients receiving ranolazine (p = 0.001). The hazard ratio for ranolazine versus placebo was 0.84 (95% confidence interval: 0.67 to 1.05; p = 0.117) for VT, VF, or death. In a pre-specified secondary analysis, patients randomized to ranolazine had a marginally significant lower risk of ICD therapies for recurrent VT or VF (hazard ratio: 0.70; 95% confidence interval: 0.51 to 0.96; p = 0.028). There were no other significant treatment effects in other pre-specified secondary analyses, which included individual components of the primary endpoint, inappropriate shocks, cardiac hospitalizations, and quality of life. CONCLUSIONS: In high-risk ICD patients, treatment with ranolazine did not significantly reduce the incidence of the first VT or VF, or death. However, the study was underpowered to detect a difference in the primary endpoint. In prespecified secondary endpoint analyses, ranolazine administration was associated with a significant reduction in recurrent VT or VF requiring ICD therapy without evidence for increased mortality. (Ranolazine Implantable Cardioverter-Defibrillator Trial [RAID]; NCT01215253).


Asunto(s)
Fármacos Cardiovasculares/uso terapéutico , Desfibriladores Implantables/tendencias , Ranolazina/uso terapéutico , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/prevención & control , Anciano , Desfibriladores Implantables/efectos adversos , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/fisiopatología , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/fisiopatología
10.
J Interv Card Electrophysiol ; 53(2): 239-247, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30105428

RESUMEN

PURPOSE: Use of novel medical technologies, such as leadless pacemaker (LP) therapy, may be subjected to a learning curve effect. The objective of the current study was to assess the impact of operators' experience on the occurrence of serious adverse device effects (SADE) and procedural efficiency. METHODS: Patients implanted with a Nanostim LP (Abbott, USA) within two prospective studies (i.e., LEADLESS ll IDE and Leadless Observational Study) were assessed. Patients were categorized into quartiles based on operator experience. Learning curve analysis included the comparison of SADE rates at 30 days post-implant per quartile and between patients in quartile 4 (> 10 implants) and patients in quartiles 1 through 3 (1-10 implants). Procedural efficiency was assessed based on procedure duration and repositioning attempts. RESULTS: Nanostim LP implant was performed in 1439 patients by 171 implanters at 60 centers in 10 countries. A total of 91 (6.4%) patients experienced a SADE in the first 30 days. SADE rates dropped from 7.4 to 4.5% (p = 0.038) after more than 10 implants per operator. Total procedure duration decreased from 30.9 ± 19.1 min in quartile 1 to 21.6 ± 13.2 min (p < 0.001) in quartile 4. The need for multiple repositionings during the LP procedure reduced in quartile 4 (14.8%), compared to quartiles 1 (26.8%; p < 0.001), 2 (26.6%; p < 0.001), and 3 (20.4%; p = 0.03). CONCLUSIONS: Learning curves exist for Nanostim LP implantation. Procedure efficiency improved with increased operator experience, according to a decrease in the incidence of SADE, procedure duration, and repositioning attempts.


Asunto(s)
Arritmias Cardíacas/terapia , Electrofisiología Cardíaca/educación , Diseño de Equipo , Curva de Aprendizaje , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico por imagen , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Electrodos Implantados , Femenino , Humanos , Internacionalidad , Modelos Logísticos , Masculino , Monitoreo Fisiológico/métodos , Análisis Multivariante , Pronóstico , Estudios Prospectivos , Análisis y Desempeño de Tareas , Factores de Tiempo
11.
Heart Rhythm ; 15(7): 1023-1030, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29957188

RESUMEN

BACKGROUND: Leadless cardiac pacemakers (LCPs) aim to mitigate lead- and pocket-related complications seen with transvenous pacemakers (TVPs). OBJECTIVE: The purpose of this study was to compare complications between the LCP cohort from the LEADLESS Pacemaker IDE Study (Leadless II) trial and a propensity score-matched real-world TVP cohort. METHODS: The multicenter LEADLESS II trial evaluated the safety and efficacy of the Nanostim LCP (Abbott, Abbott Park, IL) using structured follow-up, with serious adverse device effects independently adjudicated. TVP data were obtained from Truven Health MarketScan claims databases for patients implanted with single-chamber TVPs between April 1, 2010 and March 31, 2014 and more than 1 year of preimplant enrollment data. Comorbidities and complications were identified via International Classification of Diseases, Ninth Revision and Current Procedural Terminology codes. Short-term (≤1 months) and mid-term (>1-18 months) complications were compared between the LCP cohort and a propensity score-matched subset of the TVP cohort. RESULTS: Among 718 patients with LCPs (mean age 75.6 ± 11.9 years; 62% men) and 1436 patients with TVPs (mean age 76.1 ± 12.3 years; 63% men), patients with LCPs experienced fewer complications (hazard ratio 0.44; 95% confidence interval 0.32-0.60; P < .001), including short-term (5.8% vs 9.4%; P = .01) and mid-term (0.56% vs 4.9%; P < .001) events. In the short-term time frame, patients with LCPs had more pericardial effusions (1.53% vs 0.35%; P = .005); similar rates of vascular events (1.11% vs 0.42%; P = .085), dislodgments (0.97% vs 1.39%; P = .54), and generator complications (0.70% vs 0.28%; P = .17); and no thoracic trauma compared to patients with TVPs (rate of thoracic trauma 3.27%). In short- and mid-term time frames, TVP events absent from the LCP group included lead-related, pocket-related, and infectious complications. CONCLUSION: Patients with LCPs experienced fewer overall short- and mid-term complications, including infectious and lead- and pocket-related events, but more pericardial effusions, which were uncommon but serious.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Cateterismo Venoso Central , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/etiología , Puntaje de Propensión , Anciano , Arritmias Cardíacas/fisiopatología , Diseño de Equipo , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Derrame Pericárdico/diagnóstico , Pronóstico , Estudios Retrospectivos , Factores de Tiempo
12.
Circulation ; 128(9): 944-53, 2013 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-23979626

RESUMEN

BACKGROUND: The most frequent complications associated with implantable cardioverter-defibrillators (ICDs) involve the transvenous leads. A subcutaneous implantable cardioverter-defibrillator (S-ICD) has been developed as an alternative system. This study evaluated the safety and effectiveness of the S-ICD System (Cameron Health/Boston Scientific) for the treatment of life-threatening ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation). METHODS AND RESULTS: This prospective, nonrandomized, multicenter trial included adult patients with a standard indication for an ICD, who neither required pacing nor had documented pace-terminable ventricular tachycardia. The primary safety end point was the 180-day S-ICD System complication-free rate compared with a prespecified performance goal of 79%. The primary effectiveness end point was the induced ventricular fibrillation conversion rate compared with a prespecified performance goal of 88%, with success defined as 2 consecutive ventricular fibrillation conversions of 4 attempts. Detection and conversion of spontaneous episodes were also evaluated. Device implantation was attempted in 321 of 330 enrolled patients, and 314 patients underwent successful implantation. The cohort was followed for a mean duration of 11 months. The study population was 74% male with a mean age of 52±16 years and mean left ventricular ejection fraction of 36±16%. A previous transvenous ICD had been implanted in 13%. Both primary end points were met: The 180-day system complication-free rate was 99%, and sensitivity analysis of the acute ventricular fibrillation conversion rate was >90% in the entire cohort. There were 38 discrete spontaneous episodes of ventricular tachycardia/ventricular fibrillation recorded in 21 patients (6.7%), all of which successfully converted. Forty-one patients (13.1%) received an inappropriate shock. CONCLUSIONS: The findings support the efficacy and safety of the S-ICD System for the treatment of life-threatening ventricular arrhythmias.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular/terapia , Adulto , Anciano , Estudios de Cohortes , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
13.
Circulation ; 123(10): 1061-72, 2011 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-21357819

RESUMEN

BACKGROUND: This study aimed to determine whether QRS morphology identifies patients who benefit from cardiac resynchronization therapy with a defibrillator (CRT-D) and whether it influences the risk of primary and secondary end points in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial. METHODS AND RESULTS: Baseline 12-lead ECGs were evaluated with regard to QRS morphology. Heart failure event or death was the primary end point of the trial. Death, heart failure event, ventricular tachycardia, and ventricular fibrillation were secondary end points. Among 1817 patients with available sinus rhythm ECGs at baseline, there were 1281 (70%) with left bundle-branch block (LBBB), 228 (13%) with right bundle-branch block, and 308 (17%) with nonspecific intraventricular conduction disturbances. The latter 2 groups were defined as non-LBBB groups. Hazard ratios for the primary end point for comparisons of CRT-D patients versus patients who only received an implantable cardioverter defibrillator (ICD) were significantly (P < 0.001) lower in LBBB patients (0.47; P < 0.001) than in non-LBBB patients (1.24; P = 0.257). The risk of ventricular tachycardia, ventricular fibrillation, or death was decreased significantly in CRT-D patients with LBBB but not in non-LBBB patients. Echocardiographic parameters showed significantly (P < 0.001) greater reduction in left ventricular volumes and increase in ejection fraction with CRT-D in LBBB than in non-LBBB patients. CONCLUSIONS: Heart failure patients with New York Heart Association class I or II and ejection fraction ≤ 30% and LBBB derive substantial clinical benefit from CRT-D: a reduction in heart failure progression and a reduction in the risk of ventricular tachyarrhythmias. No clinical benefit was observed in patients with a non-LBBB QRS pattern (right bundle-branch block or intraventricular conduction disturbances). CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Anciano , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/mortalidad , Bloqueo de Rama/terapia , Electrocardiografía , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Riesgo , Volumen Sistólico , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Ultrasonografía , Fibrilación Ventricular/diagnóstico por imagen , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/terapia