RESUMEN
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an almost totally cine-fluoroscopic guided procedure. The amount of radiation used during the procedure is strictly related to the fluoroscopy time (FT), that has already been demonstrated to be associated with outcomes and complexity of coronary procedures. The aim of our study is to demonstrate the relationship between FT and the short-term outcomes after TAVR defined by to the Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. METHODS: After splitting 1797 consecutive patients into tertiles of FT, the composite endpoint early safety (ES) was adjudicated according to VARC-2 and VARC-3 definitions, whereas the composite endpoints device success (DS) and technical success (TS) according to VARC-3 criteria. RESULTS: The absence of all these outcomes (VARC-2 ES amd VARC-3 TS, DS, and ES) was significantly associated with longer FT: this association was independent from both intraprocedural complications and other intraprocedural factors linked to longer FT, and still persisted after propensity score matching analysis. Notwithstanding, after receiver operating characteristic analysis, FT had adequate diagnostic accuracy in identifying the absence of only VARC-3 TS and VARC-2 ES. CONCLUSION: Longer FT is related with periprocedural and short-term outcomes after the procedure, especially in those that are more challenging. A FT duration of more than 30 min has an adequate accuracy in identifying VARC-3 technical failure (TS and DS) and absence of VARC-2 ES, selecting patients who are likely to take advantage from more careful in-hospital follow-up.
RESUMEN
BACKGROUND: Acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is a frequent complication associated with adverse outcomes and mortality. Various scores have been developed to predict this complication in the coronary setting. However, none have ever been tested in a large TAVI population. This study aimed to evaluate the power of four different scores in predicting AKI after TAVI. METHODS: Overall, 1535 consecutive TAVI patients from the observational multicentric "Magna Graecia" TAVI registry were included in the analysis. Of the study population, 235 (15.31%) developed AKI early. The Mehran, William Beaumont Hospital, CR4EATME3AD3, and ACEF scores were calculated retrospectively. RESULTS: The patients who developed TAVI-related AKI had significantly higher absolute values of all risk scores than those who did not. The receiver-operating characteristic analysis also showed a significant correlation between these four scores and AKI, but without a significant difference among all of them (p value = 0.176). Nevertheless, based on their area under the curve values (≤0.604 for all), none had adequate diagnostic accuracy in predicting TAVI-related AKI. Importantly, multivariate analysis identified myocardial revascularization close to the TAVI procedure and implantation of self-expanding prostheses, as well as atrial fibrillation, low-osmolar contrast media administration, corrected contrast medium volume, and any transfusion (p value < 0.05 for all) as independent risk factors for AKI. CONCLUSIONS: Although high values of current AKI risk scores are significantly associated with the development of this complication, these are not sufficiently accurate. Further studies are needed so that a TAVI-dedicated AKI risk score may be created.
Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodosAsunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Accidente Cerebrovascular/prevención & control , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Válvula Aórtica/cirugíaRESUMEN
BACKGROUND: Patients with coronary artery disease and concomitant heart failure (left ventricular ejection fraction < 35%) requiring myocardial revascularization are at risk of poor long-term prognosis and higher mortality. The benefits of minimally invasive extracorporeal circulation (MiECC), particularly in end-stage coronary artery disease patients undergoing myocardial revascularization, have not been completely described. MATERIALS AND METHODS: In this single-centre control study, 60 end-stage coronary artery disease patients undergoing isolated coronary artery bypass grafting (CABG) were included. Patients were divided into two groups of 30 patients each undergoing CABG using MiECC or conventional extracorporeal circulation (cECC). RESULTS: In the MiECC group, oxygen delivery index (DO2i) was 305 mL/min/m2 in relation to indexed oxygen extraction ratio (O2ERi) 21.5%, whereas in the cECC group DO2i was 288 mL/min/m2 in relation to O2ERi 25.6% (p = 0.037). Lactate levels > 3 mmol/L were reported in 7 MiECC patients vs 20 cECC patients (p = 0.038), with blood glucose peak. Mean nadir hemoglobin values during cardiopulmonary bypass (CPB) were 9.7 g/dL in the MiECC group vs 7.8 g/dL in the cECC group (p = 0.044). Cardiac index during CPB was 2.4 L/min/m2 in both groups. Red blood cell units administered were 8 vs 21 units in the MiECC vs cECC group (p = 0.022). A glycemic peak was recorded in 7 patients of the MiECC group and in 20 patients of the cECC group (p = 0.037). CONCLUSION: In end-stage coronary artery disease, the MiECC technique was associated with a higher DO2i compared to cECC. MiECC patients showed a significant reduction in red blood cell unit administration and peak intraoperative lactate levels, which correlated with better postoperative outcome.