Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38224255

RESUMEN

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de Registros
2.
Ann Thorac Surg ; 115(1): 266-271, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35970228

RESUMEN

PURPOSE: Saphenous vein graft (SVG) failure is a complex phenomenon, with technical, biologic, and local factors contributing to early and medium- and long-term failure after coronary artery bypass graft. Both technical and conduit factors may have significant impact on early SVG failure. DESCRIPTION: We review the complex factors that play a pathogenic role in SVG failure, followed by review of the existing literature on potential utility of high-definition optical coherence tomography (OCT) in comprehensive intraoperative assessment of SVGs. EVALUATION: We describe a new technique for intraoperative acquisition of OCT images in the harvested SVGs and introduce a classification system for pathologic processes that can be detected in the harvested SVG conduits by OCT. CONCLUSIONS: The potential impact on early graft failure of the exclusion of segments of SVGs that are less than optimal (ie, containing fibroatheroma, retained thrombus, sclerotic valves, or procurement injury) will be examined in the randomized controlled OCTOCAB (Intraoperative Optical Coherence Tomography of the Saphenous Vein Conduit in Patients Undergoing Coronary Artery Bypass Surgery) trial.


Asunto(s)
Placa Aterosclerótica , Tomografía de Coherencia Óptica , Humanos , Puente de Arteria Coronaria/métodos , Stents , Vena Safena/trasplante , Angiografía Coronaria , Grado de Desobstrucción Vascular , Resultado del Tratamiento
4.
JACC Cardiovasc Interv ; 14(18): 2010-2021, 2021 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-34556275

RESUMEN

OBJECTIVES: The aim of this study was to determine clinical and echocardiographic characteristics, mechanisms of failure, and outcomes of mitral valve (MV) surgery after transcatheter edge-to-edge repair (TEER). BACKGROUND: Although >100,000 mitral TEER procedures have been performed worldwide, longitudinal data on MV surgery after TEER are lacking. METHODS: Data from the multicenter, international CUTTING-EDGE registry were retrospectively analyzed. Clinical and echocardiographic outcomes were evaluated. Median follow-up duration was 9.0 months (interquartile range [IQR]: 1.2-25.7 months) after MV surgery, and follow-up was 96.1% complete at 30 days and 81.1% complete at 1 year. RESULTS: From July 2009 to July 2020, 332 patients across 34 centers underwent MV surgery after TEER. The mean age was 73.8 ± 10.1 years, median Society of Thoracic Surgeons risk for MV repair at initial TEER was 4.0 (IQR: 2.3-7.3), and primary/mixed and secondary mitral regurgitation were present in 59.0% and 38.5%, respectively. The median interval from TEER to surgery was 3.5 months (IQR: 0.5-11.9 months), with overall median Society of Thoracic Surgeons risk of 4.8% for MV replacement (IQR: 2.8%-8.4%). The primary indication for surgery was recurrent mitral regurgitation (33.5%), and MV replacement and concomitant tricuspid surgery were performed in 92.5% and 42.2% of patients, respectively. The 30-day and 1-year mortality rates were 16.6% and 31.3%, respectively. On Kaplan-Meier analysis, the actuarial estimates of mortality were 24.1% at 1 year and 31.7% at 3 years after MV surgery. CONCLUSIONS: In this first report of the CUTTING-EDGE registry, the mortality and morbidity risks of MV surgery after TEER were not negligible, and only <10% of patients underwent MV repair. These registry data provide valuable insights for further research to improve these outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA