Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Tomography ; 5(1): 135-144, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30854451

RESUMEN

Standard-of-care multiparameter magnetic resonance imaging (MRI) scans of the brain were used to objectively subdivide glioblastoma multiforme (GBM) tumors into regions that correspond to variations in blood flow, interstitial edema, and cellular density. We hypothesized that the distribution of these distinct tumor ecological "habitats" at the time of presentation will impact the course of the disease. We retrospectively analyzed initial MRI scans in 2 groups of patients diagnosed with GBM, a long-term survival group comprising subjects who survived >36 month postdiagnosis, and a short-term survival group comprising subjects who survived ≤19 month postdiagnosis. The single-institution discovery cohort contained 22 subjects in each group, while the multi-institution validation cohort contained 15 subjects per group. MRI voxel intensities were calibrated, and tumor voxels clustered on contrast-enhanced T1-weighted and fluid-attenuated inversion-recovery (FLAIR) images into 6 distinct "habitats" based on low- to medium- to high-contrast enhancement and low-high signal on FLAIR scans. Habitat 6 (high signal on calibrated contrast-enhanced T1-weighted and FLAIR sequences) comprised a significantly higher volume fraction of tumors in the long-term survival group (discovery cohort, 35% ± 6.5%; validation cohort, 34% ± 4.8%) compared with tumors in the short-term survival group (discovery cohort, 17% ± 4.5%, P < .03; validation cohort, 16 ± 4.0%, P < .007). Of the 6 distinct MRI-defined habitats, the fractional tumor volume of habitat 6 at diagnosis was significantly predictive of long- or short-term survival. We discuss a possible mechanistic basis for this association and implications for habitat-driven adaptive therapy of GBM.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Glioblastoma/diagnóstico por imagen , Adulto , Anciano , Neoplasias Encefálicas/patología , Medios de Contraste , Femenino , Glioblastoma/patología , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Estimación de Kaplan-Meier , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Adulto Joven
2.
Ultrasound Med Biol ; 39(11): 2137-46, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23932272

RESUMEN

In contrast to the clinically used microbubble ultrasound contrast agents, nanoscale bubbles (or nanobubbles) may potentially extravasate into tumors that exhibit more permeable vasculature, facilitating targeted molecular imaging and drug delivery. Our group recently presented a simple strategy using the non-ionic surfactant Pluronic as a size control excipient to produce nanobubbles with a mean diameter of 200 nm that exhibited stability and echogenicity on par with microbubbles. The objective of this study was to carry out an in-depth characterization of nanobubble properties as compared with Definity microbubbles, both in vitro and in vivo. Through use of a tissue-mimicking phantom, in vitro experiments measured the echogenicity of the contrast agent solutions and the contrast agent dissolution rate over time. Nanobubbles were found to be more echogenic than Definity microbubbles at three different harmonic frequencies (8, 6.2 and 3.5 MHz). Definity microbubbles also dissolved 1.67 times faster than nanobubbles. Pharmacokinetic studies were then performed in vivo in a subcutaneous human colorectal adenocarcinoma (LS174T) in mice. The peak enhancement and decay rates of contrast agents after bolus injection in the liver, kidney and tumor were analyzed. No significant differences were observed in peak enhancement between the nanobubble and Definity groups in the three tested regions (tumor, liver and kidney). However, the decay rates of nanobubbles in tumor and kidney were significantly slower than those of Definity in the first 200-s fast initial phase. There were no significant differences in the decay rates in the liver in the initial phase or in three regions of interest in the terminal phase. Our results suggest that the stability and acoustic properties of the new nanobubble contrast agents are superior to those of the clinically used Definity microbubbles. The slower washout of nanobubbles in tumors suggests potential entrapment of the bubbles within the tumor parenchyma.


Asunto(s)
Fluorocarburos/farmacocinética , Nanopartículas , Poloxámero/farmacocinética , Ultrasonografía/métodos , Animales , Fluorocarburos/química , Ensayo de Materiales , Tasa de Depuración Metabólica , Ratones , Ratones Desnudos , Nanopartículas/química , Especificidad de Órganos , Fantasmas de Imagen , Poloxámero/química , Distribución Tisular , Ultrasonografía/instrumentación
3.
J Ultrasound Med ; 31(12): 1909-16, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23197543

RESUMEN

OBJECTIVES: The purpose of this study was to quantitatively assess the contrast kinetics of vascular endothelial growth factor receptor 2 (VEGFR2)-targeted microbubbles (BR55; Bracco Suisse, Geneva, Switzerland) compared to clinically used microbubbles (SonoVue; Bracco SpA, Milan, Italy) in both normal liver and human hepatocellular carcinoma xenograft tumors in mice. METHODS: Microbubbles were injected intravenously into healthy mice (n = 5) and mice bearing hepatocellular carcinoma xenograft tumors (n = 10). Cine loops of contrast enhancement in normal liver and the tumors were acquired for 10 minutes. Quantitative perfusion parameters were derived by fitting time-intensity curves using a dedicated mathematical model combining a bolus function and a ramp function. Immunohistochemical examinations were also performed for normal liver and tumor specimens to determine the level of VEGFR2 expression. RESULTS: The peak contrast enhancement observed in normal liver with BR55 was comparable to that with SonoVue, whereas a significant difference was observed in latephase enhancement at 10 minutes (ramp slope: P < .01). In the tumor model, SonoVue was rapidly cleared from the circulation, without any noticeable binding in the tumor, whereas BR55 showed a gradual decline, resulting in a longer wash-out period (mean transit time: P < .01). Immunohistochemical examinations showed that intratumoral vascular endothelial cells had sparse and weak VEGFR2 expression, whereas the sinusoidal capillaries in normal liver had much more diffuse and much stronger expression. CONCLUSIONS: Our results suggest that BR55 accurately reflects the VEGFR2 status in human hepatocellular carcinoma xenograft tumors. We showed that quantification applied to molecular ultrasound imaging may provide an objective method for measuring the degree of microbubble binding.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Hígado/diagnóstico por imagen , Microburbujas , Técnicas de Diagnóstico Molecular/métodos , Receptor 2 de Factores de Crecimiento Endotelial Vascular/análisis , Animales , Línea Celular Tumoral , Humanos , Ratones , Ratones Endogámicos BALB C , Trasplante de Neoplasias/diagnóstico por imagen , Ultrasonografía
4.
Artículo en Inglés | MEDLINE | ID: mdl-21041137

RESUMEN

The differentiation between benign and malignant focal liver lesions plays an important role in diagnosis of liver disease and therapeutic planning of local or general disease. This differentiation, based on characterization, relies on the observation of the dynamic vascular patterns (DVP) of lesions with respect to adjacent parenchyma, and may be assessed during contrast-enhanced ultrasound imaging after a bolus injection. For instance, hemangiomas (i.e., benign lesions) exhibit hyper-enhanced signatures over time, whereas metastases (i.e., malignant lesions) frequently present hyperenhanced foci during the arterial phase and always become hypo-enhanced afterwards. The objective of this work was to develop a new parametric imaging technique, aimed at mapping the DVP signatures into a single image called a DVP parametric image, conceived as a diagnostic aid tool for characterizing lesion types. The methodology consisted in processing a time sequence of images (DICOM video data) using four consecutive steps: (1) pre-processing combining image motion correction and linearization to derive an echo-power signal, in each pixel, proportional to local contrast agent concentration over time; (2) signal modeling, by means of a curve-fitting optimization, to compute a difference signal in each pixel, as the subtraction of adjacent parenchyma kinetic from the echopower signal; (3) classification of difference signals; and (4) parametric image rendering to represent classified pixels as a support for diagnosis. DVP parametric imaging was the object of a clinical assessment on a total of 146 lesions, imaged using different medical ultrasound systems. The resulting sensitivity and specificity were 97% and 91%, respectively, which compare favorably with scores of 81 to 95% and 80 to 95% reported in medical literature for sensitivity and specificity, respectively.


Asunto(s)
Medios de Contraste , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Hígado/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador , Algoritmos , Bases de Datos Factuales , Humanos , Hígado/irrigación sanguínea , Neoplasias Hepáticas/irrigación sanguínea , Microburbujas , Movimiento (Física) , Sensibilidad y Especificidad , Ultrasonografía , Grabación en Video
5.
Artículo en Inglés | MEDLINE | ID: mdl-16846144

RESUMEN

A new formalism is presented for the destruction-replenishment perfusion quantification approach at low mechanical index. On the basis of physical considerations, best-fit methods should be applied using perfusion functions with S-shape characteristics. These functions are first described for the case of a geometry with a single flow velocity, then extended to the case of vascular beds with blood vessels having multiple flow velocity values and directions. The principles guiding the analysis are, on one hand, a linearization of video echo signals to overcome the log-compression of the imaging instrument, and, on the other hand, the spatial distribution of the transmit-receive ultrasound beam in the elevation direction. An in vitro model also is described; it was used to confirm experimentally the validity of the approach using a commercial contrast agent. The approach was implemented in the form of a computer program, taking as input a sequence of contrast-specific images, as well as parameters related to the ultrasound imaging equipment used. The generated output is either flow-parameter values computed in regions-of-interest, or parametric flow-images (e.g., mean velocity, mean transit time, mean flow, flow variance, or skewness). This approach thus establishes a base for extracting information about the morphology of vascular beds in vivo, and could allow absolute quantification provided that appropriate instrument calibration is implemented.


Asunto(s)
Arterias/diagnóstico por imagen , Arterias/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Ecocardiografía/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Flujo Sanguíneo Regional/fisiología , Algoritmos , Animales , Simulación por Computador , Medios de Contraste , Ecocardiografía/instrumentación , Humanos , Modelos Cardiovasculares , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA