1.
Phys Med Biol ; 69(12)2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38776943

RESUMEN

Objective.To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy.Approach.Phantoms of polyethylene, gelatin, or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion beams. Post-irradiation, 4D PET images were acquired and parent11C,10C and15O radionuclides contributions in each voxel were determined from the extracted time activity curves. Next, the experimental configurations were simulated in Geant4 Monte Carlo versions 10.0 to 11.1, with three different fragmentation models-binary ion cascade (BIC), quantum molecular dynamics (QMD) and the Liege intranuclear cascade (INCL++) - 30 model-version combinations. Total positron annihilation and parent isotope production yields predicted by each simulation were compared between simulations and experiments using normalised mean squared error and Pearson cross-correlation coefficient. Finally, we compared the depth of the maximum positron annihilation yield and the distal point at which the positron yield decreases to 50% of peak between each model and the experimental results.Main results.Performance varied considerably across versions and models, with no one version/model combination providing the best prediction of all positron-emitting fragments in all evaluated target materials and irradiation conditions. BIC in Geant4 10.2 provided the best overall agreement with experimental results in the largest number of test cases. QMD consistently provided the best estimates of both the depth of peak positron yield (10.4 and 10.6) and the distal 50%-of-peak point (10.2), while BIC also performed well and INCL generally performed the worst across most Geant4 versions.Significance.The best predictions of the spatial distribution of positron annihilations and positron-emitting fragment production along the beam path during carbon and oxygen ion therapy was obtained using Geant4 10.2.p03 with BIC or QMD. These version/model combinations are recommended for future heavy ion therapy research.


Asunto(s)
Método de Montecarlo , Electrones/uso terapéutico , Radioterapia de Iones Pesados/métodos , Tomografía de Emisión de Positrones , Fantasmas de Imagen
2.
Phys Med Biol ; 67(19)2022 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-35947996

RESUMEN

Objective. We aim to evaluate a method for estimating 1D physical dose deposition profiles in carbon ion therapy via analysis of dynamic PET images using a deep residual learning convolutional neural network (CNN). The method is validated using Monte Carlo simulations of12C ion spread-out Bragg peak (SOBP) profiles, and demonstrated with an experimental PET image.Approach. A set of dose deposition and positron annihilation profiles for monoenergetic12C ion pencil beams in PMMA are first generated using Monte Carlo simulations. From these, a set of random polyenergetic dose and positron annihilation profiles are synthesised and used to train the CNN. Performance is evaluated by generating a second set of simulated12C ion SOBP profiles (one 116 mm SOBP profile and ten 60 mm SOBP profiles), and using the trained neural network to estimate the dose profile deposited by each beam and the position of the distal edge of the SOBP. Next, the same methods are used to evaluate the network using an experimental PET image, obtained after irradiating a PMMA phantom with a12C ion beam at QST's Heavy Ion Medical Accelerator in Chiba facility in Chiba, Japan. The performance of the CNN is compared to that of a recently published iterative technique using the same simulated and experimental12C SOBP profiles.Main results. The CNN estimated the simulated dose profiles with a mean relative error (MRE) of 0.7% ± 1.0% and the distal edge position with an accuracy of 0.1 mm ± 0.2 mm, and estimate the dose delivered by the experimental12C ion beam with a MRE of 3.7%, and the distal edge with an accuracy of 1.7 mm.Significance. The CNN was able to produce estimates of the dose distribution with comparable or improved accuracy and computational efficiency compared to the iterative method and other similar PET-based direct dose quantification techniques.


Asunto(s)
Radioterapia de Iones Pesados , Polimetil Metacrilato , Carbono/uso terapéutico , Radioterapia de Iones Pesados/métodos , Método de Montecarlo , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos
3.
Sci Rep ; 12(1): 5863, 2022 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-35393505

RESUMEN

Neutron Capture Enhanced Particle Therapy (NCEPT) boosts the effectiveness of particle therapy by capturing thermal neutrons produced by beam-target nuclear interactions in and around the treatment site, using tumour-specific [Formula: see text]B or [Formula: see text]Gd-based neutron capture agents. Neutron captures release high-LET secondary particles together with gamma photons with energies of 478 keV or one of several energies up to 7.94 MeV, for [Formula: see text]B and [Formula: see text]Gd, respectively. A key requirement for NCEPT's translation is the development of in vivo dosimetry techniques which can measure both the direct ion dose and the dose due to neutron capture. In this work, we report signatures which can be used to discriminate between photons resulting from neutron capture and those originating from other processes. A Geant4 Monte Carlo simulation study into timing and energy thresholds for discrimination of prompt gamma photons resulting from thermal neutron capture during NCEPT was conducted. Three simulated [Formula: see text] mm[Formula: see text] cubic PMMA targets were irradiated by [Formula: see text]He or [Formula: see text]C ion beams with a spread out Bragg peak (SOBP) depth range of 60 mm; one target is homogeneous while the others include [Formula: see text] mm[Formula: see text] neutron capture inserts (NCIs) of pure [Formula: see text]B or [Formula: see text]Gd located at the distal edge of the SOBP. The arrival times of photons and neutrons entering a simulated [Formula: see text] mm[Formula: see text] ideal detector were recorded. A temporal mask of 50-60 ns was found to be optimal for maximising the discrimination of the photons resulting from the neutron capture by boron and gadolinium. A range of candidate detector and thermal neutron shielding materials were simulated, and detections meeting the proposed acceptance criteria (i.e. falling within the target energy window and arriving 60 ns post beam-off) were classified as true or false positives, depending on their origin. The ratio of true/false positives ([Formula: see text]) was calculated; for targets with [Formula: see text]B and [Formula: see text]Gd NCIs, the detector materials which resulted in the highest [Formula: see text] were cadmium-shielded CdTe and boron-shielded LSO, respectively. The optimal irradiation period for both carbon and helium ions was 1 µs for the [Formula: see text]B NCI and 1 ms for the [Formula: see text]Gd NCI.


Asunto(s)
Compuestos de Cadmio , Puntos Cuánticos , Boro , Método de Montecarlo , Neutrones , Telurio
4.
Phys Med Biol ; 65(23): 235051, 2020 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-33336650

RESUMEN

The purpose of this work is to develop a validated Geant4 simulation model of a whole-body prototype PET scanner constructed from the four-layer depth-of-interaction detectors developed at the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Japan. The simulation model emulates the behaviour of the unique depth of interaction sensing capability of the scanner without needing to directly simulate optical photon transport in the scintillator and photodetector modules. The model was validated by evaluating and comparing performance metrics from the NEMA NU 2-2012 protocol on both the simulated and physical scanner, including spatial resolution, sensitivity, scatter fraction, noise equivalent count rates and image quality. The results show that the average sensitivities of the scanner in the field-of-view were 5.9 cps kBq-1 and 6.0 cps kBq-1 for experiment and simulation, respectively. The average spatial resolutions measured for point sources placed at several radial offsets were 5.2± 0.7 mm and 5.0± 0.8 mm FWHM for experiment and simulation, respectively. The peak NECR was 22.9 kcps at 7.4 kBq ml-1 for the experiment, while the NECR obtained via simulation was 23.3 kcps at the same activity. The scatter fractions were 44% and 41.3% for the experiment and simulation, respectively. Contrast recovery estimates performed in different regions of a simulated image quality phantom matched the experimental results with an average error of -8.7% and +3.4% for hot and cold lesions, respectively. The results demonstrate that the developed Geant4 model reliably reproduces the key NEMA NU 2-2012 performance metrics evaluated on the prototype PET scanner. A simplified version of the model is included as an advanced example in Geant4 version 10.5.


Asunto(s)
Método de Montecarlo , Tomografía de Emisión de Positrones/instrumentación , Imagen de Cuerpo Entero/instrumentación , Diseño de Equipo , Fantasmas de Imagen , Fotones
5.
Phys Med Biol ; 65(23): 235052, 2020 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-33283764

RESUMEN

This work presents an iterative method for the estimation of the absolute dose distribution in patients undergoing carbon ion therapy, via analysis of the distribution of positron annihilations resulting from the decay of positron-emitting fragments created in the target volume. The proposed method relies on the decomposition of the total positron-annihilation distributions into profiles of the three principal positron-emitting fragment species - 11C, 10C and 15O. A library of basis functions is constructed by simulating a range of monoenergetic 12C ion irradiations of a homogeneous polymethyl methacrylate phantom and measuring the resulting one-dimensional positron-emitting fragment profiles and dose distributions. To estimate the dose delivered during an arbitrary polyenergetic irradiation, a linear combination of factors from the fragment profile library is iteratively fitted to the decomposed positron annihilation profile acquired during the irradiation, and the resulting weights combined with the corresponding monoenergetic dose profiles to estimate the total dose distribution. A total variation regularisation term is incorporated into the fitting process to suppress high-frequency noise. The method was evaluated with 14 different polyenergetic 12C dose profiles in a polymethyl methacrylate target: one which produces a flat biological dose, 10 with randomised energy weighting factors, and three with distinct dose maxima or minima within the spread-out Bragg peak region. The proposed method is able to calculate the dose profile with mean relative errors of 0.8%, 1.0% and 1.6% from the 11C, 10C, 15O fragment profiles, respectively, and estimate the position of the distal edge of the SOBP to within an average of 0.7 mm, 1.9 mm and 1.2 mm of its true location.


Asunto(s)
Radioterapia de Iones Pesados/métodos , Tomografía de Emisión de Positrones , Dosis de Radiación , Radioterapia Guiada por Imagen/métodos , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica
6.
Phys Med Biol ; 64(15): 155014, 2019 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-31167173

RESUMEN

The distribution of fragmentation products predicted by Monte Carlo simulations of heavy ion therapy depend on the hadronic physics model chosen in the simulation. This work aims to evaluate three alternative hadronic inelastic fragmentation physics options available in the Geant4 Monte Carlo radiation physics simulation framework to determine which model most accurately predicts the production of positron-emitting fragmentation products observable using in-beam PET imaging. Fragment distributions obtained with the BIC, QMD, and INCL + + physics models in Geant4 version 10.2.p03 are compared to experimental data obtained at the HIMAC heavy-ion treatment facility at NIRS in Chiba, Japan. For both simulations and experiments, monoenergetic beams are applied to three different block phantoms composed of gelatin, poly(methyl methacrylate) and polyethylene. The yields of the positron-emitting nuclei 11C, 10C and 15O obtained from simulations conducted with each model are compared to the experimental yields estimated by fitting a multi-exponential radioactive decay model to dynamic PET images using the normalised mean square error metric in the entrance, build up/Bragg peak and tail regions. Significant differences in positron-emitting fragment yield are observed among the three physics models with the best overall fit to experimental 12C and 16O beam measurements obtained with the BIC physics model.


Asunto(s)
Radioterapia de Iones Pesados/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Programas Informáticos/normas , Carbono/uso terapéutico , Método de Montecarlo , Oxígeno/uso terapéutico , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/normas
7.
Phys Med Biol ; 64(9): 095014, 2019 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-30978704

RESUMEN

Parallax error caused by the detector crystal thickness degrades spatial resolution at the peripheral regions of the field-of-view (FOV) of a scanner. To resolve this issue, depth-of-interaction (DOI) measurement is a promising solution to improve the spatial resolution and its uniformity over the entire FOV. Even though DOI detectors have been used in dedicated systems with a small ring diameter such as for the human brain, breast and small animals, the use of DOI detectors for a large bore whole-body PET system has not been demonstrated yet. We have developed a four-layered DOI detector, and its potential for a brain dedicated system has been proven in our previous development. In the present work, we investigated the use of the four-layer DOI detector for a large bore PET system by developing the world's first whole-body prototype. We evaluated its performance characteristics in accordance with the NEMA NU 2 standard. Furthermore, the impact of incorporating DOI information was evaluated with the NEMA NU 4 image quality phantom. Point source images were reconstructed with a filtered back projection (FBP), and an average spatial resolution of 5.2 ± 0.7 mm was obtained. For the FBP image, the four-layer DOI information improved the radial spatial resolution by 48% at the 20 cm offset position. The peak noise-equivalent count rate (NECR) was 22.9 kcps at 7.4 kBq ml-1 and the scatter fraction was 44%. The system sensitivity was 5.9 kcps MBq-1. For the NEMA NU 2 image quality phantom, the 10 mm sphere was clearly visualized without any artifacts. For the NEMA NU 4 image quality phantom, we measured the phantom at 0, 10 and 20 cm offset positions. As a result, we found the image with four-layer DOI could visualize the 2 mm-diameter hot cylinder although it could not be recognized on the image without DOI. The average improvements in the recovery coefficients for the five hot rods (1-5 mm) were 0.3%, 4.4% and 26.3% at the 0, 10 and 20 cm offset positions, respectively (except for the 1 mm-diameter rod at the 20 cm offset position). Although several practical issues (such as adding end-shields) remain to be addressed before the scanner is ready for clinical use, we showed that the four-layer DOI technology provided higher and more uniform spatial resolution over the FOV and improved contrast for small uptake regions located at the peripheral FOV, which could improve detectability of small and distal lesions such as nodal metastases, especially in obese patients.


Asunto(s)
Tomografía de Emisión de Positrones/instrumentación , Diseño de Equipo , Humanos , Fantasmas de Imagen , Sensibilidad y Especificidad