Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Med ; 13(9)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38731222

RESUMEN

Background: Aortic valve-sparing aortic root replacement (VSARR) David procedure has not been routinely performed via minimally invasive access due to its complexity. Methods: We compared our results for mini-VSARR to sternotomy-VSARR from another excellence center. Results: Eighty-four patients, 62 in the sternotomy-VSARR group and 22 in the mini-VSARR group, were included. A baseline, the aneurysm dimensions were higher in the mini-VSARR group. Propensity matching resulted in 17 pairs with comparable characteristics. Aortic cross-clamp and cardiopulmonary bypass times were significantly longer in the mini-VSARR group, by 60 and 20 min, respectively (p < 0.001). In-hospital outcomes were comparable between the groups. Drainage volumes were numerically lower, and hospital length of stay was, on average, 3 days shorter (p < 0.001) in the mini-VSARR group. At a median follow-up of 5.5 years, there was no difference in mortality (p = 0.230). Survival at 1, 5 and 10 years was 100%, 100%, and 95% and 95%, 87% and 84% in the mini-VSARR and sternotomy-VSARR groups, respectively. No repeat interventions on the aortic valve were documented. Echocardiographic follow-up was complete in 91% with excellent durability of repair regardless of the approach: no cases of moderate/severe aortic regurgitation were reported in the mini-VSARR group. Conclusions: The favorable outcomes, reduced drainage, and shorter hospital stays associated with the mini-sternotomy approach underscore its potential advantages expanding beyond cosmetic outcome.

2.
Cardiol J ; 25(1): 81-86, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28653315

RESUMEN

BACKGROUND: The number of patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy and defibrillator (CRT-D) is growing. This results in high workloads for centers performing standard controls (SC) of these systems. Medtronic CareLink Express® (MCLE) is a solution enabling remote controls (RC) of implantable devices. In cases of detecting arrhythmias or device malfunctioning, it automatically generates alarms transmitted to the controlling physician. The objective of the study was to evaluate the effectiveness of alarms generated by MCLE in identification of patients that require clinically significant intervention during SC. METHODS: A total of 119 patients (age 64 ± 14, 17 women) implanted with ICD/CRT-D were included in the trial. Device reprogramming or pharmacological treatment modifications during SC were as-sessed as significant if they were required for optimal clinical management of the patient (effectiveness of antiarrhythmic and resynchronization therapy, also patient safety). Analysis of generated alarms was then performed to assess the effectiveness (sensitivity and specificity) of MCLE in identifying patients that require changes in therapy. RESULTS: Data from 129 transmissions and 129 subsequent SCs were analyzed. 179 alarms were recorded during 96 (74%) transmissions. A total of 333 program changes of implanted devices took place during 107 (83%) SCs. Device reprogramming was considered clinically significant in 27 cases Additionaly, 13 pharmacological treatment modifications were performed. Sensitivity and specificity of alarms generated by MCLE with regards to identification of patients requiring clinically significant intervention was 87% and 31%, respectively. Finally, a statistically significant difference was observed in the number of clinically significant interventions among patients with and without MCLE alarms (33 [86.8%] vs. 5 [13.2%], p = 0.037). CONCLUSIONS: Medtronic CareLink Express® is an RC system enabling high-sensitivity supervision of patients with cardiac.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Terapia por Estimulación Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Telemetría/instrumentación , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA