Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Heliyon ; 10(18): e37631, 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-39309872

RESUMEN

The progress in tribocorrosion performance of the engineering parts is in dire need of improving their surface properties. In the present contribution, Ni-Cr-ZrO2 layers were electrodeposited on St37 steel. The stress was put on optimizing the process factors, including the parameters involved in pulsed current electrodeposition and level of the ZrO2 reinforcing nanoparticles (0-20 g/L) in the bath. The surface characteristics of the electrodeposits were evaluated using FESEM, EDS, AFM, and XRD. The tribomechanical characteristics of the films were determined using a Vickers microhardness tester and pin-on-disk apparatus. The electrochemical behavior of the samples was studied using OCP, EIS, PDP, and immersion techniques. The results demonstrated that the included ZrO2 nanoparticles led to more homogenous, rougher, and defect-free surfaces, while they did not change the phase composition of the alloy electrodeposits. The polarization resistance of the Ni-Cr alloy coating increases by 6.7 times when 10 g/L of the reinforcing nanoparticles is added to the electrolyte. A decrease of ≈42 % in the mean COF value was obtained by the incorporation of 10 g/L ZrO2 nanoparticles into the plating bath. The coating system developed holds the promise to address both technical requirements and health concerns.

2.
Sci Rep ; 13(1): 16045, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37749260

RESUMEN

NiTi is a class of metallic biomaterials, benefit from superelastic behavior, high biocompatibility, and favorable mechanical properties close to that of bone. However, the Ni ion leaching, poor bioactivity, and antibacterial activity limit its clinical applications. In this study, HAp-Nb2O5 composite layers were PC electrodeposited from aqueous electrolytes containing different concentrations of the Nb2O5 particles, i.e., 0-1 g/L, to evaluate the influence of the applied surface engineering strategy on in vitro immersion behavior, Ni2+ ion leaching level, and antibacterial activity of the bare NiTi. Surface characteristics of the electrodeposited layers were analyzed using SEM, TEM, XPS, and AFM. The immersion behavior of the samples was comprehensively investigated through SBF and long-term PBS soaking. Gram-negative Escherichia coli (E. coli) and Gram-positive Staphylococcus aureus (S. aureus) infective reference bacteria were employed to address the antibacterial activity of the samples. The results illustrated that the included particles led to more compact and smoother layers. Unlike bare NiTi, composite layers stimulated apatite formation upon immersion in both SBF and PBS media. The concentration of the released Ni2+ ion from the composite layer, containing 0.50 g/L Nb2O5 was ≈ 60% less than that of bare NiTi within 30 days of immersion in the corrosive PBS solution. The Nb2O5-reinforced layers exhibited high anti-adhesive activity against both types of pathogenic bacteria. The hybrid metallic-ceramic system comprising HAp-Nb2O5-coated NiTi offers the prospect of a potential solution for clinical challenges facing the orthopedic application of NiTi.


Asunto(s)
Materiales Biocompatibles , Escherichia coli , Materiales Biocompatibles/farmacología , Staphylococcus aureus , Inmersión , Niobio , Antibacterianos/farmacología , Propiedades de Superficie , Titanio/farmacología , Ensayo de Materiales
3.
Biomater Adv ; 150: 213435, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37098321

RESUMEN

The surface properties of NiTi, as an interface between the synthetic implant and living tissue, play a vital role in guaranteeing implantation success, especially during the initial stage. This contribution endeavors to enhance the surface features of NiTi orthopedic implants through the application of HAp-based coatings, placing emphasis on assessing the influence of Nb2O5 particles concentration in the electrolyte on resultant properties of HAp-Nb2O5 composite electrodeposits. The coatings were electrodeposited via pulse current mode under galvanostatic current control from an electrolyte containing 0-1 g/L of Nb2O5 particles. Surface morphology, topography, and phase composition were evaluated using FESEM, AFM, and XRD, respectively. EDS was employed to study surface chemistry. In vitro biomineralization and osteogenic activity of the samples were studied by immersing the samples in SBF and incubating them with osteoblastic SAOS-2 cells, respectively. The added Nb2O5 particles, at the optimum concentration, stimulated biomineralization, suppressed the Ni ion leaching, and improved SAOS-2 cell adhesion and proliferation. NiTi implant coated by HAp-0.50 g/L Nb2O5 layer showed tremendous osteogenic properties. Overall, the HAp-Nb2O5 composite layers bring forth fascinating coating in vitro biological performance, reducing Ni leaching, and promoting osteogenic activity, which are fundamental for the successful use of NiTi in vivo.


Asunto(s)
Materiales Biocompatibles Revestidos , Niobio , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/química , Prótesis e Implantes , Níquel/química
4.
ACS Omega ; 7(11): 9088-9107, 2022 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-35356687

RESUMEN

Typically, pure niobium oxide coatings are deposited on metallic substrates, such as commercially pure Ti, Ti6Al4 V alloys, stainless steels, niobium, TiNb alloy, and Mg alloys using techniques such as sputter deposition, sol-gel deposition, anodizing, and wet plasma electrolytic oxidation. The relative advantages and limitations of these coating techniques are considered, with particular emphasis on biomedical applications. The properties of a wide range of pure and modified niobium oxide coatings are illustrated, including their thickness, morphology, microstructure, elemental composition, phase composition, surface roughness and hardness. The corrosion resistance, tribological characteristics and cell viability/proliferation of the coatings are illustrated using data from electrochemical, wear resistance and biological cell culture measurements. Critical R&D needs for the development of improved future niobium oxide coatings, in the laboratory and in practice, are highlighted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA