Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 606
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
EuroIntervention ; 20(13): e793-e805, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38949240

RESUMEN

Periprocedural stroke after transcatheter aortic valve implantation (TAVI) remains a significant issue, which is associated with high morbidity, and is increasingly important as intervention shifts to younger and lower-risk populations. Over the last decade of clinical experience with TAVI, the incidence of periprocedural stroke has stayed largely unchanged, although it is prone to underreporting due to variation in ascertainment methods. The aetiology of stroke in TAVI patients is multifactorial, and changing risk profiles, differing study populations, and frequent device iterations have made it difficult to discern consistent risk factors. The objective of this review is to analyse and clarify the contemporary published literature on the epidemiology and mechanisms of neurological events in TAVI patients and evaluate potential preventive measures. This summary aims to improve patient risk assessment and refine case selection for cerebral embolic protection devices, while also providing a foundation for designing future trials focused on stroke prevention.


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Estenosis de la Válvula Aórtica/cirugía , Medición de Riesgo , Válvula Aórtica/cirugía , Incidencia , Resultado del Tratamiento , Dispositivos de Protección Embólica
2.
Am J Cardiol ; 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38871158

RESUMEN

The benefit of mechanical circulatory support with Impella (Abiomed, Inc., Danvers, Massachusetts) for high-risk percutaneous coronary intervention (HR-PCI) is uncertain. PROTECT III registry data showed improved outcomes with Impella compared with historical data (PROTECT II) but lacks a direct comparison with the HR-PCI cohort without Impella support. We retrospectively identified patients meeting the PROTECT III inclusion criteria for HR-PCI and compared this group (non-Impella cohort [NonIMP]) with the outcomes data from the PROTECT III registry (Impella cohort). Baseline differences were balanced using inverse propensity weighting. The coprimary outcome was major adverse cardiac events (MACE) in-hospital and at 90 days. A total of 283 patients at great risk did not receive Impella support; 200 patients had 90-days event ascertainment and were included in the inverse propensity weighting analysis and compared with 504 patients in the Impella cohort group. After calibration, few residual differences remained between groups. The primary outcome was not different in-hospital (3.0% vs 4.8%, p = 0.403) but less in NonIMP at 90 days (7.5% vs 13.8%, p = 0.033). Periprocedural vascular complications, bleeding, and transfusion rate did not differ between groups; however, acute kidney injury occurred more frequently in the NonIMP group (10.5% vs 5.4%, p = 0.023). In conclusion, under identical HR-PCI inclusion criteria for Impella use in PROTECT III, an institutional non-Impella-supported HR-PCI cohort showed similar MACE in-hospital but fewer MACE at 90 days, whereas there was no signal for periprocedural harm with Impella use. These results do not support routine usage of Impella for patients with HR-PCI.

4.
Circ Cardiovasc Interv ; : e014143, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38853766

RESUMEN

Bioprosthetic aortic valve thrombosis is frequently detected after transcatheter and surgical aortic valve replacement due to advances in cardiac computed tomography angiography technology and standardized surveillance protocols in low-surgical-risk transcatheter aortic valve replacement trials. However, evidence is limited concerning whether subclinical leaflet thrombosis leads to clinical adverse events or premature structural valve deterioration. Furthermore, there may be net harm in the form of bleeding from aggressive antithrombotic treatment in patients with subclinical leaflet thrombosis. This review will discuss the incidence, mechanisms, diagnosis, and optimal management of bioprosthetic aortic valve thrombosis after transcatheter aortic valve replacement and bioprosthetic surgical aortic valve replacement.

5.
J Am Heart Assoc ; 13(11): e032291, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38818933

RESUMEN

BACKGROUND: Hemoglobin (Hgb) drop without bleeding is common among patients undergoing transcatheter aortic valve replacement; however, the clinical implications of significant Hgb drop have not been fully evaluated. METHODS AND RESULTS: Consecutive patients undergoing transcatheter aortic valve replacement at our institution from 2011 to 2021 were retrospectively reviewed. Three groups were assessed: no Hgb drop and no bleed (NoD-NoB [reference group]), Hgb drop with bleed, and Hgb drop and no bleed (D-NoB). Hgb drop was defined as ≥3 g/dL decrease from pre- to post-transcatheter aortic valve replacement. Outcomes of interest were in-hospital death and 1-year all-cause mortality. A total of 1851 cases with complete Hgb data were included: NoD-NoB: n=1579 (85.3%); D-NoB: n=49 (2.6%); Hgb drop with bleed: n=223 (12.6%). Compared with NoD-NoB, the D-NoB group was older (81.1 versus 78.9 years of age) with higher preprocedure Hgb (12.9 versus 11.7 g/dL). In-hospital death rate was higher among patients with D-NoB versus NoD-NoB (4.5% versus 0.8%, P<0.001) and similar to Hgb drop with bleed (4.5% versus 4.1%, P=0.999). Predictors of in-hospital death were D-NoB (odds ratio [OR], 3.45 [95% CI, 1.32-8.69]) and transfusion (OR, 10.6 [95% CI, 4.25-28.2]). Landmark survival analysis found that D-NoB experienced 1-year mortality rate comparable to NoD-NoB, whereas Hgb drop with bleed had higher midterm mortality (hazard ratio [HR], 3.2 [95% CI, 1.83-5.73]), and transfusion continued to impact mortality (HR, 2.5 [95% CI, 1.79-3.63]). CONCLUSIONS: Hgb drop without bleeding is common among patients undergoing transcatheter aortic valve replacement and may represent a higher risk of periprocedural death. Blood transfusion increases short- and midterm mortality risk in patients with and without bleeding, supporting a restrictive transfusion strategy.


Asunto(s)
Estenosis de la Válvula Aórtica , Hemoglobinas , Mortalidad Hospitalaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Estudios Retrospectivos , Hemoglobinas/metabolismo , Hemoglobinas/análisis , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Factores de Riesgo , Resultado del Tratamiento , Medición de Riesgo/métodos
6.
Artículo en Inglés | MEDLINE | ID: mdl-38719633

RESUMEN

BACKGROUND: High-sensitivity troponin (hsTnI) is correlated with cardiac mortality; however, studies on the relationship of markedly elevated hsTnI with in-hospital mortality after cardiac surgery are sparse. Therefore, we aimed to define this relationship in order to help guide in-hospital, acute management of post-surgical patients. METHODS: We retrospectively analyzed all cardiac surgeries completed at our institution between January 2020 and June 2022 in which a peak hsTnI was noted to be >35× upper limit of normal (ULN = 34 ng/L). The primary outcome was in-hospital death. Subgroup analysis was performed to assess differences between coronary artery bypass grafting (CABG) and other cardiac surgeries. RESULTS: A total of 1382 cases met inclusion criteria. The patients' mean age was 64.8 years and 68.2 % were male. Median peak hsTnI after surgery was 4202 ng/L (interquartile ratio: 2427-7654). Univariate analysis of troponin level with mortality found that for every 1000 ng/L increase in hsTnI, odds of in-hospital death increased by 3.8 % (odds ratio [OR]: 1.038; 95 % confidence interval [CI] 1.027-1.050; p < 0.0001). In a multivariate model, troponin (OR 1.02; 95 % CI 1.01-1.04; p = 0.004) maintained a significant association with in-hospital death. CABG was associated with a lower risk of in-hospital death for any given hsTnI level up to 60,000 ng/L compared to other cardiac surgeries. CONCLUSION: Increasing hsTnI level is associated with increasing probability of in-hospital mortality and, therefore, serves as an additional, objective measure of risk to help guide in-hospital clinical management.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38769727

RESUMEN

BACKGROUND: The Evolut self-expanding valve (SEV) systems (Medtronic), were designed to accommodate varying valve sizes and reduce paravalvular leak (PVL) while maintaining a low delivery profile. These systems have evolved between product generations, alongside valve deployment techniques changing over time. AIMS: This study aimed to examine whether these changes impacted clinical outcomes. METHODS: EPROMPT is a prospective, investigator-initiated, postmarketing registry of consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) using the Evolut PRO/PRO+ SEV system. A total of 300 patients were divided into three consecutive cohorts of 100 patients according to implantation date (January to October 2018, November 2018 to July 2020, and August 2020 to November 2021). Procedural and clinical outcomes over these time periods were compared. RESULTS: Valve Academic Research Consortium (VARC)-2 device implantation success improved over time (70.0% vs. 78.0% vs. 88.8%, p = 0.01), with a similar trend for VARC-3 device success (94.7% vs. 81.7% vs. 96.8%, p < 0.001). PVL (all degrees) frequency was likewise reduced over time (31.0% vs. 17.0% vs. 19.2%, p = 0.04). Furthermore, a trend was noticed toward shorter procedure times and shorter length of stay. However, postprocedural pacemaker implantation rates did not significantly differ (15.2% vs. 21.1% vs. 14.0%, p = 0.43). CONCLUSION: During a 3-year period, we demonstrated better TAVR outcomes with newer SEV iterations, alongside changes in implantation techniques, which might result in better procedural and clinical outcomes. However, we did not see a significant change in peri-procedural pacemaker rates for SEV.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38797580

RESUMEN

BACKGROUND: Outflow graft obstruction (OGO) is an uncommon yet life-threatening complication in patients with left ventricular assist devices (LVADs). In this retrospective, single-center case series, we identify the baseline demographics and presenting features of patients who develop LVAD OGO and the procedural details and outcomes surrounding percutaneous endovascular intervention (PEI). METHODS: We conducted a retrospective review of patients with LVADs at our institution between January 2010 and February 2023 who developed OGO and were treated with PEI. Details of the PEI including procedure time, fluoroscopy time, contrast use, stent size, number of stents, change in gradient, and change in flow after intervention were collected. RESULTS: A total of 12 patients who had 14 cases of OGO were identified from January 2010 to February 2023. The average age at presentation was 64.78 years. Nine of the 14 cases occurred in male patients. Eleven of the 14 cases occurred with Heartware devices (2 recurrences), 2 in Heartmate 2 and 1 in Heartmate 3. Notable procedural details include a mean procedure time of 90.86 min and mean contrast use of 162.5 mL. The initial gradient across the OGO was reduced by an average of 72 %, to a mean post-PEI of 11.57 mmHg. The average number of stents to achieve this gradient was around 2.08, with the most common stent diameter being 10 mm. Thirty-day mortality after PEI was 7 % (1/14) in this high-risk patient population. CONCLUSION: In our single-center experience, PEI can be a safe and effective treatment for LVAD OGO.

9.
Catheter Cardiovasc Interv ; 103(6): 917-923, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38605682

RESUMEN

The advent of excimer laser coronary atherectomy (ELCA) nearly four decades ago heralded a novel way to treat complex lesions, both coronary and peripheral, which were previously untraversable and thus untreatable. These complex lesions include heavily calcified lesions, ostial lesions, bifurcation lesions, chronic total occlusions, in-stent restenosis (including stent underexpansion), and degenerative saphenous vein grafts. We discuss the technology of ELCA, its indications, applications, and complications, and suggest the "MAXCon ELCA" technique for better outcomes without increased risk. Lastly, we present a case of MAXCon ELCA effectively treating a complex lesion.


Asunto(s)
Aterectomía Coronaria , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Láseres de Excímeros , Humanos , Medios de Contraste , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Láseres de Excímeros/uso terapéutico , Solución Salina/administración & dosificación , Resultado del Tratamiento
10.
Artículo en Inglés | MEDLINE | ID: mdl-38631936

RESUMEN

BACKGROUND: Coronary microvascular dysfunction (CMD) is a prevalent condition among patients with cardiovascular risk factors, leading to a reduced quality of life and an increased risk of major adverse cardiovascular events. Novel invasive techniques have emerged to more accurately diagnose CMD. However, CMD's natural history remains poorly understood due to limited data. To address this knowledge gap, the Coronary Microvascular Disease Registry (CMDR) was established with the primary aim of standardizing comprehensive coronary functional testing and understanding of CMD. DESIGN: CMDR is a prospective, multicenter registry enrolling an unlimited number of consecutive subjects who undergo comprehensive invasive hemodynamic assessment of the entire coronary arterial vasculature. Patients undergoing acetylcholine provocation test for coronary vasospasm will also be included. Follow-up assessments will be conducted at 30 days and annually for up to 5 years. The primary endpoint is Canadian Cardiovascular Society angina grade over time. Secondary endpoints, including all-cause mortality, cardiovascular death, acute myocardial infarction, stroke, hospitalizations, medication changes, and subsequent coronary interventions, will be analyzed to establish long-term safety and clinical outcomes in patients undergoing invasive CMD assessment. SUMMARY: CMDR aims to characterize the clinical and physiologic profile of patients undergoing comprehensive invasive coronary functional testing, simultaneously providing crucial longitudinal information on the natural history and outcomes of these patients. This will shed light on CMD's course and clinical implications, which, in turn, holds the potential to significantly improve diagnostic and treatment strategies for CMD patients, ultimately leading to the enhancement of their overall prognosis and quality of life. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov, NCT05960474.

11.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
Cardiovasc Revasc Med ; 59: 9-13, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37550124

RESUMEN

BACKGROUND/PURPOSE: The cusp overlap technique has standardized implantation for self-expanding valves with the goal of achieving more consistent implantation depths and lowering permanent pacemaker (PPM) implantation rates. We retrospectively compared short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expanding valve implanted using the cusp overlap technique vs. the traditional coplanar technique in a large tertiary referral center. METHODS: We conducted a retrospective study among PPM-naïve patients who underwent TAVR using the CoreValve Evolut PRO/PRO+. We compared in-hospital PPM rates in patients who underwent TAVR using the cusp overlap technique vs. the coplanar technique. Additional outcomes included in-hospital all-cause mortality, stroke, major vascular complications, annular rupture, and >mild paravalvular leak. Furthermore, we compared outcomes over time to see whether there was evidence of a learning curve. RESULTS: Of the 528 patients included, 270 underwent TAVR using the coplanar technique and 258 underwent TAVR using the cusp overlap technique. The rate of new PPM implantation did not differ between cohorts (17.0 % vs. 16.7 %; p = 0.910). Additionally, rates of in-hospital all-cause mortality (0.0 % vs. 0.4 %; p = 0.328), stroke (3.7 % vs. 1.6 %; p = 0.124), major vascular complications (0.7 % vs. 1.2 %; p = 0.617), annular rupture (0.4 % vs. 0.0 %; p = 0.328) and >mild paravalvular leak (0.0 % vs. 0.4 %; p = 0.444) were similar. Our secondary analysis did not identify any evidence of a learning curve. CONCLUSIONS: The cusp overlap technique may not yield a reduction in PPM rates when compared with the coplanar technique. Other confounders should be explored to further minimize in-hospital PPM rates.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Diseño de Prótesis
14.
15.
Cardiovasc Revasc Med ; 58: 45-49, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37393190

RESUMEN

PURPOSE: Explore gender disparities in patients undergoing transseptal puncture (TSP) for selected transcatheter cardiac intervention procedures. METHODS: Patients who underwent TSP from January 2015 through September 2021 were reviewed. Primary outcomes were procedural and in-hospital major adverse events. Secondary endpoints were procedural success and hospitalization length of stay (LOS) >1 day. Unadjusted and multivariable-adjusted logistic regression analyses were performed to assess gender differences for in-hospital adverse events. RESULTS: The study cohort comprised 510 patients (mean [SD] age, 74 [14.0] years); 246 women (48 %) underwent TSP for left atrial appendage occlusion (LAAO) or transcatheter edge-to-edge-repair (TEER). Compared with men, women were younger, had higher CHA2DS2-VASc scores, and were more likely to have had a prior ischemic stroke, but were less likely to have paroxysmal atrial fibrillation. After multivariable adjustment, there were no differences between genders in aborted or canceled procedures (odds ratio [OR]: 0.43; 95 % confidence interval [CI]: 0.10-1.96; p = 0.277), any adverse events (OR: 1.00; 95 % CI: 0.58-1.70; p = 0.98), major adverse events (OR: 1.60; 95 % CI: 0.90-2.80; p = 0.11), or death (OR: 1.00; 95 % CI: 0.20-5.00; p = 0.31). Subgroup analysis for LAAO procedures showed that at 30 days, women had higher rates of adverse events, major adverse cardiac events, and LOS >1 day. CONCLUSIONS: Men and women showed no differences in procedural success and in-hospital adverse outcomes in unadjusted analysis and after multivariable adjustment, despite women having a higher risk profile among patients undergoing TSP. However, compared with men, women undergoing LAAO experienced a higher rate of in-hospital adverse events irrespective of TSP.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Masculino , Femenino , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Accidente Cerebrovascular Isquémico/etiología , Factores de Tiempo , Resultado del Tratamiento , Accidente Cerebrovascular/etiología
17.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37832606

RESUMEN

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Accidente Cerebrovascular/etiología , Trombosis/etiología , Resultado del Tratamiento , Diseño de Prótesis , Factores de Riesgo
19.
Am J Cardiol ; 206: 108-115, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37690148

RESUMEN

Subclinical leaflet thrombosis occurs with transcatheter heart valves (THVs) and could be associated with structural valve deterioration. The current guidelines recommend the use of antiplatelet agents after transcatheter aortic valve replacement (TAVR) but not the routine use of oral anticoagulation. Our study examines the effects of short-term warfarin therapy on THV hemodynamics at 24 months after TAVR in low-risk patients. Low-risk patients who underwent TAVR were randomly allocated 1:1 to receive low-dose aspirin (n = 50) or low-dose aspirin plus warfarin (n = 44). After 30 days of treatment, ongoing medication regimens, including anticoagulation, were at the physicians' discretion. Follow-up after a period of 24 months was available for clinical and echocardiographic outcomes. At the 24-month mark, follow-up echocardiography of the randomly allocated patients revealed just 1 additional case of new structural valve deterioration in the aspirin group (compared with the occurrence within 30 days), based on the Valve Academic Research Consortium 3 definitions. There were also no differences in mean pressure gradients (11.5 ± 0.5 mm Hg vs 11.05 ± 4.0 mm Hg, p = 0.6) or peak velocity (2.2 ± 0.5 m/s vs 2.1 ± 0.4 m/s, p = 0.7) between the groups. A composite end point (mortality, stroke, and myocardial infarction) did not show any difference between the groups at long-term follow-up (p = 0.07). In conclusion, in low-risk patients who underwent TAVR, short-term anticoagulation with warfarin did not impact clinical outcomes or THV hemodynamics by echocardiography at 24 months.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Warfarina/uso terapéutico , Aspirina/uso terapéutico , Válvula Aórtica/cirugía , Estudios de Seguimiento , Anticoagulantes/uso terapéutico , Estenosis de la Válvula Aórtica/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento
20.
JACC Cardiovasc Interv ; 16(18): 2211-2227, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37758379

RESUMEN

BACKGROUND: The MITRAL (Mitral Implantation of Transcatheter Valves) trial is the first prospective trial to evaluate the safety and feasibility of balloon-expandable aortic transcatheter heart valves in patients with failed surgical bioprostheses or annuloplasty rings and severe mitral annular calcification treated with mitral valve-in-valve (MViV), valve-in-ring (MViR), or valve-in-mitral annular calcification (ViMAC). OBJECTIVES: The aim of this study was to evaluate 5-year outcomes among these patients. METHODS: A multicenter prospective study was conducted among patients at high surgical risk at 13 U.S. sites. Patients underwent MViV (n = 30), MViR (n = 30), or ViMAC (n = 31) and were followed annually for 5 years. Kansas City Cardiomyopathy Questionnaire scores were obtained at baseline and follow-up visits. Echocardiograms were analyzed at independent core laboratories. RESULTS: A total of 91 patients underwent transcatheter mitral valve replacement (February 2015 to December 2017). The mean age was 74.3 ± 8.9 years. At 5-year follow-up, the lowest all-cause mortality was observed in the MViV group (21.4%), 94.7% of patients were in NYHA functional class I or II, and the mean mitral gradient was 6.6 ± 2.5 mm Hg. The MViR and ViMAC groups had higher all-cause mortality (65.5% and 67.9%), most survivors were in NYHA functional classes I and II (50% and 55.6%), and mean mitral gradients remained stable (5.8 ± 0.1 and 6.7 ± 2.5 mm Hg). Significant improvements in Kansas City Cardiomyopathy Questionnaire scores were observed when all 3 arms were pooled. CONCLUSIONS: MViV, MViR, and ViMAC procedures were associated with sustained improvement of heart failure symptoms and quality of life among survivors at 5 years. Transcatheter heart valve function remained stable in all 3 groups. Patients treated with MViV had excellent survival at 5 years, whereas survival was lower in the MViR and ViMAC groups, consistent with underlying disease severity. Patients with more residual mitral regurgitation had higher mortality.


Asunto(s)
Calcinosis , Cardiomiopatías , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Enfermedades Vasculares , Humanos , Anciano , Anciano de 80 o más Años , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Calcinosis/cirugía , Enfermedades Vasculares/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA