2.
Artículo en Inglés | MEDLINE | ID: mdl-39044661

RESUMEN

BACKGROUND: Although use of sirolimus-based analogs has shown superiority over paclitaxel in drug-eluting stents, the relative efficacy of these two agents released from drug-coated balloons (DCB) is unclear. The present meta-analysis is aimed to compare outcomes after percutaneous coronary intervention (PCI) with paclitaxel-coated balloons (PCB) versus sirolimus-coated balloons (SCB) for either in-stent restenosis or native de novo lesions. METHODS: The study outcomes were 1) target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or target lesion revascularization, and 2) follow-up angiographic parameters including late lumen loss (LLL), diameter stenosis, and minimal lumen diameter (MLD). Pooled odds ratios (OR) and weighted mean differences (WMD) with 95% confidence intervals (CI) were calculated by using random-effects models. RESULTS: A search of PubMed, EMBASE, and Cochrane Library from their inception to January 2024 identified five randomized clinical trials and three observational studies with a total of 1861 patients (889 in PCB and 972 in SCB groups). During 9-12 months of follow-up, there was no significant difference in TLF (OR 1.01, 95% CI 0.75-1.35) between the two groups. On follow-up angiography at 6-9 months, MLD (WMD 0.10, 95% CI 0.02-0.17) was larger in PCB but there was no statistically significant difference in LLL (WMD -0.11, 95% CI -0.23-0.02) and diameter stenosis (WMD -3.33, 95% CI -8.11-1.45). CONCLUSIONS: Among patients undergoing DCB-only PCI, the risk of TLF was similar during 9-12 months of follow-up after PCB and SCB treatment. However, the MLD was larger favoring PCB over SCB on follow-up angiography.

4.
AsiaIntervention ; 10(2): 98-99, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39070979
5.
Eur J Med Res ; 29(1): 280, 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38735968

RESUMEN

OBJECTIVES: Data on side-branch (SB) ostial effect after drug-coated balloon (DCB) treatment in the context of de novo coronary bifurcation lesions are limited. We aimed to investigate the angiographic outcomes of SB ostium after DCB treatment compared with drug-eluting stents (DESs) implantation in the main vessel (MV) or optimal medical therapy (OMT) for the treatment of de novo coronary bifurcation lesions. METHODS: Serial angiographic changes in the SB ostium were compared between DCB, DES, and medication alone for MV treatment. Δ value was calculated by subtracting the follow-up value from the pre-procedure value. RESULTS: A total of 132 bifurcation lesions were included for analysis (44 lesions in DCB group; 38 lesions in DES group; 50 lesions in OMT group). The minimal lumen diameter (MLD) of SB ostium showed an increase at follow-up in the DCB group, whereas a decrease was observed in both the DES and OMT groups (ΔMLD: -0.16 ± 0.45 mm for DCB group vs. 0.50 ± 0.52 mm for DES group vs. 0.08 ± 0.38 mm for OMT group, p < 0.001). The diameter stenosis (DS) of SB ostium showed a marked decrease at follow-up in the DCB group, in contrast to an increase observed in both the DES and OMT groups (ΔDS: 8.01 ± 18.96% for DCB group vs. -18.68 ± 18.60% for DES group vs. -2.05 ± 14.58% for OMT group, p < 0.001). CONCLUSIONS: In de novo coronary bifurcation lesions, DCB treatment on the MV demonstrated favorable angiographic outcomes in the SB ostium at 6-9 month follow-up compared to DES implantation or OMT.


Asunto(s)
Angioplastia Coronaria con Balón , Angiografía Coronaria , Stents Liberadores de Fármacos , Humanos , Stents Liberadores de Fármacos/efectos adversos , Masculino , Femenino , Angiografía Coronaria/métodos , Persona de Mediana Edad , Anciano , Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Resultado del Tratamiento , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/patología
6.
Artículo en Inglés | MEDLINE | ID: mdl-38664133

RESUMEN

Balloon angioplasty achieves luminal enlargement by fracturing the atherosclerotic intima at its point of least resistance, thereby creating a dissection plane and space with dehiscence of the intima from the media. This barotraumatic dissection triggers an inflammatory and proliferative reaction, resulting in a restenosis process at medium-term. In the era of plain old balloon angioplasty, quantitative angiographic studies at follow-up demonstrated that - the greater the acute luminal gain was after balloon angioplasty, the greater the late luminal loss was at follow-up. The interventional cardiologists coined the following motto "the more you gain, the more you lose". However, in the current era of drug coated balloon (DCB), it appears that this vexing conundrum could have been abrogated. A recently published DCB study in small de novo vessel has demonstrated that there was a slightly negative correlation between the volume of dissection assessed by optical coherence tomography and the angiographic late luminal loss (now gain) after Paclitaxel coated balloon treatment. In other words, the barotraumatic dissection does not necessarily herald a restenosis process in the era of DCB. This article revisits the mechanism of balloon angioplasty and explores how DCB with Paclitaxel may change the paradigm of balloon angioplasty as default treatment in CAD percutaneous treatment.

8.
Respir Res ; 24(1): 257, 2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37880651

RESUMEN

BACKGROUND: Mechanical thrombectomy has been shown to reduce thrombus burden and pulmonary artery pressure (PAP) and to improve right ventricular (RV) function in patients with high-risk or intermediate-high-risk pulmonary embolism (PE). As hemodynamic data after mechanical thrombectomy for PE are scarce, we aimed to assess the hemodynamic effects of mechanical thrombectomy in acute PE with right heart overload. METHODS: In this prospective, open-label study, patients with acute symptomatic, computed tomography-documented PE with signs of right heart overload underwent mechanical thrombectomy using the FlowTriever System. Right heart catheterization was performed immediately before and after thrombectomy and after three months. Transthoracic echocardiography was performed before thrombectomy, discharge, and at three months. This analysis was done after 20 patients completed three months of follow-up. RESULTS: Twenty-nine patients (34% female) underwent mechanical thrombectomy, of which 20 completed three months follow-up with right heart catheterization. Most patients were at high (17%) or intermediate-high (76%) risk and had bilateral PE (79%). Before thrombectomy, systolic PAP (sPAP) was severely elevated (mean 51.3 ± 11.6 mmHg). Mean sPAP dropped by -15.0 mmHg (95% confidence interval [CI]: -18.9 to -11.0; p < 0.001) immediately after the procedure and continued to decrease from post-thrombectomy to three months (-6.4 mmHg, 95% CI: -10-0 to -2.9; p = 0.002). RV/left ventricular (LV) ratio immediately reduced within two days by -0.37 (95% CI: -0.47 to -0.27; p < 0.001). The proportion of patients with a tricuspid annular plane systolic excursion (TAPSE)/sPAP ratio < 0.31 mm/mmHg decreased from 28% at baseline to 0% before discharge and at three months (p = 0.007). There were no procedure-related major adverse events. CONCLUSIONS: Mechanical thrombectomy for acute PE was safe and immediately reduced PAP and improved right heart function. The reduction in PAP was maintained at three months follow-up.


Asunto(s)
Embolia Pulmonar , Trombosis , Disfunción Ventricular Derecha , Humanos , Femenino , Masculino , Estudios Prospectivos , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/cirugía , Trombectomía/efectos adversos , Trombectomía/métodos , Hemodinámica , Resultado del Tratamiento
10.
Clin Res Cardiol ; 2023 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-37495797

RESUMEN

BACKGROUND AND OBJECTIVES: Recent data have established non-inferiority of drug-coated balloons (DCB) compared to drug-eluting stents (DES) for treatment of small-vessel coronary artery disease. Since coronary vessels in women might have anatomical and pathophysiological particularities, the safety of the DCB strategy among women compared to men needs to be assessed in more detail. METHODS: In BASKET-SMALL 2, patients with de novo lesions in coronary vessels < 3 mm and an indication for percutaneous coronary intervention were randomly allocated (1:1) to DCB vs. DES after successful lesion preparation. The primary objective of the randomized trial was to establish non-inferiority of DCB vs. DES regarding major adverse cardiac events (MACE; i.e., cardiac death, non-fatal myocardial infarction, and target vessel revascularization) after 12 months. The aim of the current sub-analysis is to evaluate whether the DCB strategy is equally safe among women and men after 12 and 36 months. RESULTS: Among 758 randomized patients, 382 were assigned to DCB (23% women) and 376 to DES (30% women). In general, women were older, had more often diabetes mellitus and renal insufficiency, and presented more often with an acute coronary syndrome, whereas men were more often smokers, had multivessel disease and a previous history of acute myocardial infarction, and received a treatment with a statin. After 3 years, the primary clinical end point was not significantly different between groups (13% women vs. 16% men, HR 0.82; 95% CI 0.52-1.30; p = 0.40). There was no interaction between sex and coronary intervention strategy regarding MACE at 36 months (10% women vs. 16% men in DCB, 16% women vs. 15% men in DES; pinteraction = 0.31). CONCLUSION: In small native coronary artery disease, there was no statistically significant effect of sex on the difference between DCB and DES regarding MACE up to 36 months. CLINICAL TRIAL REGISTRATION: URL: http://www. CLINICALTRIALS: gov . Unique identifier: NCT01574534. CAD coronary artery disease, MACE major adverse cardiovascular events, HR Hazard ratio, DCB drug-coated balloon, DES drug-eluting stent.

11.
J Cardiovasc Dev Dis ; 10(3)2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36975883

RESUMEN

BACKGROUND: We evaluated the outcome of PCI of de novo stenosis with drug-coated balloons (DCB) versus drug-eluting stents (DES) in patients with insulin-treated diabetes mellitus (ITDM) versus non-insulin-treated diabetes mellitus (NITDM). METHODS: Patients were randomized in the BASKET-SMALL 2 trial to DCB or DES and followed over 3 years for MACE (cardiac death, non-fatal myocardial infarction [MI], and target vessel revascularization [TVR]). Outcome in the diabetic subgroup (n = 252) was analyzed with respect to ITDM or NITDM. RESULTS: In NITDM patients (n = 157), rates of MACE (16.7% vs. 21.9%, hazard ratio [HR] 0.68, 95% confidence interval [CI] 0.29-1.58, p = 0.37), death, non-fatal MI, and TVR (8.4% vs. 14.5%, HR 0.30, 95% CI 0.09-1.03, p = 0.057) were similar between DCB and DES. In ITDM patients (n = 95), rates of MACE (DCB 23.4% vs. DES 22.7%, HR 1.12, 95% CI 0.46-2.74, p = 0.81), death, non-fatal MI, and TVR (10.1% vs. 15.7%, HR 0.64, 95% CI 0.18-2.27, p = 0.49) were similar between DCB and DES. TVR was significantly lower with DCB versus DES in all diabetic patients (HR 0.41, 95% CI 0.18-0.95, p = 0.038). CONCLUSIONS: DCB compared to DES for treatment of de novo coronary lesions in diabetic patients was associated with similar rates of MACE and numerically lower need for TVR both for ITDM and NITDM patients.

12.
Clin Res Cardiol ; 112(5): 677-690, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36680617

RESUMEN

AIM: Transcatheter aortic valve replacement (TAVR) can cause intraventricular conduction disturbances (ICA), particularly left bundle branch block (BBB) and high-degree atrioventricular block (HAVB). The aim of this study was to investigate clinical, anatomical, procedural, and electrophysiological parameters predicting ICA after TAVR. METHODS: Patients with severe aortic stenosis (n = 203) without pacing devices undergoing TAVR with a self-expanding (n = 103) or balloon-expanding (n = 100) valve were enrolled. Clinical and anatomical parameters, such as length of the membranous septum (MS) and implantation depth, were assessed. His-ventricular interval (HVi) before and after implantation was determined. 12-lead-electrocardiograms (ECG) before, during and after 3 and 30 days after TAVR were analyzed for detection of any ICA. RESULTS: Among 203 consecutive patients (aortic valve area 0.78 ± 0.18 cm2, age 80 ± 6 years, 54% male, left ventricular ejection fraction 52 ± 10%), TAVR led to a significant prolongation of infranodal conduction in all patients from 49 ± 10 ms to 59 ± 16 ms (p = 0.01). The HVi prolongation was independent of valve types, occurrence of HAVB or ICA. Fifteen patients (7%) developed HAVB requiring permanent pacemaker (PPM) implantation and 63 patients (31%) developed ICA within 30 days. Pre-existing BBB (OR 11.64; 95% CI 2.87-47.20; p = 0.001), new-onset left BBB (OR 15.72; 95% CI 3.05-81.03; p = 0.001), and diabetes mellitus (OR 3.88; 95% CI 1.30-15.99; p = 0.02) independently predicted HAVB requiring PPM. Neither pre-existing right BBB, a prolonged postHVi, increases in PR duration, any of the TAVR implantation procedural and anatomic nor echocardiographic characteristics were predictive for later HAVB. CONCLUSIONS: New-onset left BBB and diabetes mellitus independently predicted HAVB requiring PPM after TAVR and helped to identify patients at risk. Electrophysiologic study (EPS) of atrioventricular conduction was neither specific nor predictive of HAVB and can be skipped. TRIAL REGISTRATION NUMBER: NCT04128384 ( https://www. CLINICALTRIALS: gov ).


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/efectos adversos , Factores de Riesgo , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
13.
PLoS One ; 18(1): e0280206, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36706120

RESUMEN

BACKGROUND: Long diseased vessel segments of peripheral arteries may display irregular shapes with different diameters. The aim of this study was to investigate inhibition of neointimal proliferation in porcine peripheral vessels with different diameters covered by one single hyper-compliant drug-coated balloon (HCDCB), compared to conventional drug-coated balloons (DCB), each selected according to the respective vessel diameter. METHODS AND RESULTS: Neointimal proliferation was stimulated in proximal and distal segments of the peripheral arteries by balloon overstretch and stent implantation. Inhibition of neointimal proliferation by one single HCDCB was compared to two vessel diameter-adjusted DCB per artery and to one single uncoated hyper-compliant balloon (HCB). Sixteen HCB, 16 HCDCB, and 32 DCB were used in 16 arteries each. Quantitative angiography (QA), optical coherence tomography (OCT) and histology showed a similar anti-restenotic effect for one HCDCB compared to two vessel diameter-adjusted DCB in narrow distal and wider proximal segments (QA diameter stenosis: 18.7±12.3% vs. 22.8±15.5%, p = 0.535; OCT area stenosis: 21.4±11.6% vs. 23.6±12.3%, p = 0.850; histomorphometry diameter stenosis: 27.5±7.1% vs. 26.9±8.0%, p = 0.952) and indicated significant inhibition of neointimal proliferation by HCDCB vs. uncoated HCB (QA diameter stenosis: 18.7±12.3% vs. 30.3±16.7%, p = 0.008; OCT area stenosis: 21.4±11.6% vs. 34.7±16.0%, p = 0.004; histomorphometry diameter stenosis: 27.5±7.1% vs. 32.5±8.5%, p = 0.038). CONCLUSIONS: HCDCB were found to be similar effective as DCB in inhibiting neointimal proliferation in vessel segments with different diameters. One single long HCDCB may allow for treatment of segments with variable diameters, and thus, replace the use of several vessel diameter-adjusted DCB.


Asunto(s)
Angioplastia de Balón , Paclitaxel , Porcinos , Animales , Constricción Patológica/patología , Paclitaxel/farmacología , Vasos Coronarios/patología , Neointima/patología , Proliferación Celular , Materiales Biocompatibles Revestidos/farmacología , Stents
14.
J Soc Cardiovasc Angiogr Interv ; 2(3): 100625, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39130710

RESUMEN

Drug-coated balloons are approved outside the United States, not only for the treatment of peripheral arteries but also for coronary arteries. This review describes the technological basics, the scenarios of clinical application, and the current available data from clinical trials for the different coronary indications.

15.
Front Biosci (Landmark Ed) ; 27(10): 283, 2022 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-36336862

RESUMEN

BACKGROUND: Although controversially discussed, paclitaxel is the only clinically proven drug that inhibits restenosis when released from drug-coated balloons (DCBs). Limus drugs are currently being explored as alternatives. The aim of the preclinical studies was to investigate drug candidates beyond paclitaxel considered for balloon coating. METHODS: Drugs were tested with respect to dissolution in organic solvents, coating on balloons, and drug transfer to the vessel wall. Inhibition of neointimal proliferation was tested in the porcine model of coronary in-stent stenosis. Intravascular drug treatment was achieved by DCBs at the time of stent implantation. RESULTS: Coating had to be adjusted for each drug. Doses on the balloons ranged from 1.0 to 8.6 µg/mm2 balloon surface. Satisfactory amounts of drug ranging from 5% to 29% of initial doses were transferred into the vessel wall. Angiographic parameters such as late lumen loss (LLL) at 4 weeks did not show reduction of in-stent neointimal proliferation by treatment with arsenic trioxide (0.87 ± 0.44 mm), betamethasone dipropionate (1.00 ± 0.54 mm), bortezomib (1.74 ± 0.46 mm), green tea extract (1.24 ± 0.51 mm), fantolon, an epothilone (0.86 ± 0.61 mm), methotrexate (1.09 ± 0.72 mm), and thalidomide (1.59 ± 0.55 mm) compared to treatment with uncoated balloons (1.07 ± 0.60 mm), while coatings with paclitaxel reliably reduced in-stent stenosis (LLL = 0.36 ± 0.25 mm). CONCLUSIONS: Despite the proven antiproliferative and/or anti-inflammatory effect of the drugs, none of the coatings significantly reduced LLL compared to uncoated balloons and thus, based on the results presented here, none of the tested coatings may be considered a substitute for the paclitaxel-based coatings currently in clinical use.


Asunto(s)
Angioplastia Coronaria con Balón , Paclitaxel , Porcinos , Animales , Paclitaxel/farmacología , Angioplastia Coronaria con Balón/métodos , Constricción Patológica/tratamiento farmacológico , Stents , Materiales Biocompatibles Revestidos/farmacología , Resultado del Tratamiento
16.
Biomedicines ; 10(10)2022 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-36289897

RESUMEN

Pressure-overload-induced cardiac hypertrophy represents one cause of the development of heart failure. The aim of this study is to characterize the influence of the TIR-domain-containing adapter-inducing interferon-ß (TRIF) during afterload-induced myocardial remodeling. After trans-aortic constriction (TAC), cardiac pressure overload leads to an early increase in MyD88- (Myeloid differentiation primary response gene 88) and TRIF-dependent cytokines. The maximum cytokine expression appeared within the first week and decreased to its control level within five weeks. While cardiomyocyte hypertrophy was comparable, the myocardial accumulation of the inflammatory cells was lower in TRIF-/-mice. At d7, TRIF deficiency reduced transcription factors and TRIF-dependent cytokines. Through the modulation of the TGF-ß-signaling pathway and anti-fibrotic microRNAs, TRIF was involved in the development of interstitial fibrosis. The absence of TRIF was associated with a decreased expression of proapoptotic proteins. In echocardiography and working heart analyses, TRIF deficiency slowed left-ventricular wall thickening, myocardial hypertrophy, and reduces the ejection fraction. In summary, TRIF is an important adapter protein for the release of inflammatory cytokines and the accumulation of inflammatory cells in the early stage of maladaptive cardiac remodeling. TRIF is involved in the development of cardiac fibrosis by modulating inflammatory and fibrotic signal transduction pathways.

17.
Postepy Kardiol Interwencyjnej ; 18(2): 122-130, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36051841

RESUMEN

Introduction: In BASKET-SMALL 2, drug-coated balloons (DCB) were non-inferior to drug-eluting stents (DES) in de-novo stenosis of small coronary vessels (≤ 2.75 mm) regarding clinical endpoints up to 36 months. Aim: In the present subgroup analysis, we aimed to analyze the effect of the two treatment strategies in different vessel sizes. Material and methods: Patients were analyzed according to the size of the device used (small > 2.5 mm vs. very small ≤ 2.5 mm). The primary endpoint was major adverse cardiac events (MACE), while secondary endpoints were target vessel revascularization (TVR), non-fatal myocardial infarction, cardiac death, and all-cause mortality, all at 36 months. Interactions for the different groups were assessed with Cox regression analysis. Results: Overall, 758 patients were enrolled in this analysis, of which 437 (58%) had very small vessel disease. There were similar results in both treatment groups for the primary endpoint in both small and very small vessels (DCB vs DES, MACE at 3 years in small vessels HR = 1.31, 95% CI: 0.74-2.32, p = 0.355, and very small vessels HR = 0.82, 95% CI: 0.49-1.39, p = 0.468). Second generation paclitaxel-eluting stents showed significantly higher rates for MACE (p = 0.041), TVR (p = 0.004) and non-fatal myocardial infarction (p = 0.036) compared to DCB in very small coronary arteries at 3 years, while results were similar in small coronary arteries. Conclusions: Efficacy and safety of DCB are similar irrespective of vessel size. However, there is a beneficial effect of DCB over paclitaxel-eluting stents regarding TVR, non-fatal myocardial infarction and MACE that is most pronounced in very small coronary arteries.

18.
Circ Cardiovasc Interv ; 15(9): e012305, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36126132

RESUMEN

BACKGROUND: Paclitaxel-coated balloons (PCBs) are a preferred treatment option for coronary in-stent restenosis. To date, data from randomized trials of alternative drug coatings are lacking. The aim of the randomized Malaysian and German-Swiss randomized trials was to investigate a novel sirolimus-coated balloon (SCB) compared with a PCB in in-stent restenosis. METHODS: One hundred one patients with drug-eluting stent in-stent restenosis were enrolled in 2 identical randomized trials comparing the novel SCB (SeQuent SCB, 4 µg/mm²) with the clinically proven PCB (SeQuent Please, 3 µg/mm²). Primary end point was angiographic late lumen loss at 6 months. Secondary end points included procedural success, major adverse cardiac events, and individual clinical end points such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis. RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.25±0.57 mm in the PCB group versus 0.26±0.60 mm in the SCB group. Mean difference between SCB and PCB was 0.01 (95% CI, -0.23 to 0.24). Noninferiority at a predefined margin of 0.35 was shown. Clinical events up to 12 months did not differ between the groups. CONCLUSIONS: This first-in man comparison of a novel SCB with a crystalline coating showed similar angiographic and clinical outcomes in the treatment of coronary drug-eluting stent in-stent restenosis compared with PCB. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02996318, NCT03242096.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria , Stents Liberadores de Fármacos , Bifenilos Policlorados , Angioplastia Coronaria con Balón/efectos adversos , Constricción Patológica/inducido químicamente , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Humanos , Paclitaxel/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Sirolimus/efectos adversos , Stents , Resultado del Tratamiento
19.
Circ Cardiovasc Interv ; 15(4): e011569, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35411792

RESUMEN

BACKGROUND: Patients at high-bleeding risk (HBR) undergoing percutaneous coronary intervention represent a challenging patient population. The use of drug-coated balloon (DCB) allows shorter duration of dual antiplatelet therapy compared with drug-eluting stents (DES) and reduces thrombotic risk due to the absence of a permanent implant. The present analysis aimed to investigate if the effect of DCB versus DES differed between patients with and without HBR treated with percutaneous coronary intervention in small coronary arteries. METHODS: This prespecified subgroup analysis of a multicenter, randomized, noninferiority trial included 758 patients with de novo lesions in coronary vessels <3 mm and an indication for percutaneous coronary intervention, randomized to DCB (n=382) or second-generation DES (n=376). Patients were followed over 3 years for major adverse cardiac events. RESULTS: Of the 758 patients randomized, 155 (20%) had HBR; these patients had higher mortality at 3 years (hazard ratio [95% CI], 3.09 [1.78-5.36]; P<0.001). Rates of major bleeding events were overall low but tended to be lower after DCB versus DES (1.6% versus 3.7%; P=0.064), were similar in patients with HBR (4.5% versus 3.4%) but less frequent in DCB-versus DES-treated patients without HBR (0.9% versus 3.8%). There was no difference in major adverse cardiac events between DCB and DES regardless of bleeding risk (HBR, hazard ratio: 1.16 [0.51-2.62]; P=0.719 versus non-HBR, 0.96 [0.62-1.49]; P=0.863). CONCLUSIONS: DCBs were similarly safe and effective as current-generation DES in the treatment of coronary arteries <3 mm, regardless of bleeding risk. In patients treated with DCB, there was a trend towards a reduction of severe bleeding events at 3 years. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01574534.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Hemorragia/inducido químicamente , Humanos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
20.
JACC Cardiovasc Interv ; 15(7): 770-779, 2022 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-35305906

RESUMEN

OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB). BACKGROUND: There is increasing clinical evidence for the treatment of coronary de novo disease using drug-coated balloons. However, it is unclear whether paclitaxel remains the drug of choice or if sirolimus is an alternative, in analogy to drug-eluting stents. METHODS: Seventy patients with coronary de novo lesions were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, B. Braun Melsungen; 4 µg/mm2) with a PCB (SeQuent Please, B. Braun Melsungen; 3 µg/mm2). The primary endpoint was angiographic late lumen loss (LLL) at 6 months. Secondary endpoints included major adverse cardiovascular events and individual clinical endpoints such as cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis. RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment LLL was 0.01 ± 0.33 mm in the PCB group versus 0.10 ± 0.32 mm in the SCB group. The mean difference between SCB and PCB was 0.08 (95% CI: -0.07 to 0.24). Noninferiority at a predefined margin of 0.35 was shown. However, negative LLL was more frequent in the PCB group (60% of lesions vs 32% in the SCB group; P = 0.019). Major adverse cardiovascular events up to 12 months also did not differ between the groups. CONCLUSIONS: This first-in-human comparison of a novel SCB with a crystalline coating showed similar angiographic outcomes in the treatment of coronary de novo disease compared with a clinically proven PCB. However, late luminal enlargement was more frequently observed after PCB treatment. (Treatment of Coronary De-Novo Stenosis by a Sirolimus Coated Balloon or a Paclitaxel Coated Balloon Catheter Malaysia [SCBDNMAL]; NCT04017364).


Asunto(s)
Angioplastia Coronaria con Balón , Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Humanos , Paclitaxel/efectos adversos , Estudios Prospectivos , Sirolimus/efectos adversos , Resultado del Tratamiento