1.
Eur J Radiol ; 146: 110080, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34875474

RESUMEN

PURPOSE: Computed tomography (CT) might be a good diagnostic test to accurately quantify calcium in vascular beds but there are multiple factors influencing the quantification. The aim of this study was to investigate the influence of different computed tomography protocol settings in the quantification of calcium in the lower extremities using modified Agatston and volume scores. METHODS: Fresh-frozen human legs were scanned at different tube current protocols and reconstructed at different slice thickness. Two different iterative reconstruction protocols for conventional CT images were compared. Calcium was manually scored using modified Agatston and volume scores. Outcomes were statistically analyzed using Wilcoxon signed-rank tests and mean absolute and relative differences were plotted in Bland-Altman plots. RESULTS: Of the 20 legs, 16 had CT detectable calcifications. Differences between thick and thin slice reconstruction protocols were 129 Agatston units and 125% for Agatston and 78.4 mm3 and 57.8% for volume (all p ≤ 0.001). No significant differences were found between low and high tube current protocols. Differences between iDose4 and IMR reconstruction protocols for modified Agatston were 34.2 Agatston units and 17.7% and the volume score 33.5 mm3 and 21.2% (all p ≤ 0.001). CONCLUSIONS: Slice thickness reconstruction and reconstruction method protocols influenced the modified Agatston and volume scores in leg arteries, but tube current and different observers did not have an effect. This data emphasizes the need for standardized quantification of leg artery calcifications. Possible implications are in the development of a more universal quantification method, independent of the type of scan and vasculature.


Asunto(s)
Calcio , Enfermedad de la Arteria Coronaria , Algoritmos , Cadáver , Calcio/análisis , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Pierna/diagnóstico por imagen , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X
2.
Eur Radiol Exp ; 2(1): 30, 2018 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-30402740

RESUMEN

BACKGROUND: Computed tomography (CT) emphysema quantification is affected by both radiation dose (i.e. image noise) and reconstruction technique. At reduced dose, filtered back projection (FBP) results in an overestimation of the amount of emphysema due to higher noise levels, while the use of iterative reconstruction (IR) can result in an underestimation due to reduced noise. The objective of this study was to determine the influence of dose reduction and hybrid IR (HIR) or model-based IR (MIR) on CT emphysema quantification. METHODS: Twenty-two patients underwent inspiratory chest CT scan at routine radiation dose and at 45%, 60% and 75% reduced radiation dose. Acquisitions were reconstructed with FBP, HIR and MIR. Emphysema was quantified using the 15th percentile of the attenuation curve and the percentage of voxels below -950 HU. To determine whether the use of a different percentile or HU threshold is more accurate at reduced dose levels and with IR, additional measurements were performed using different percentiles and HU thresholds to determine the optimal combination. RESULTS: Dose reduction resulted in a significant overestimation of emphysema, while HIR and MIR resulted in an underestimation. Lower HU thresholds with FBP at reduced dose and higher HU thresholds with HIR and MIR resulted in emphysema percentages comparable to the reference. The 15th percentile quantification method showed similar results as the HU threshold method. CONCLUSIONS: This within-patients study showed that CT emphysema quantification is significantly affected by dose reduction and IR. This can potentially be solved by adapting commonly used thresholds.

3.
Med Phys ; 45(7): 3031-3042, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29749624

RESUMEN

PURPOSE: Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips Healthcare) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips Healthcare), by means of phantom experiments. METHODS: For both CT scanners, conventional CT images were acquired using four adult scanning protocols: (a) body helical, (b) body axial, (c) head helical, and (d) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. RESULTS: The resolution levels at 50%, 10%, and 5% MTF of the iCT and IQon showed small, but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with differences up to 0.51. Spatial resolution did not change with phantom size, but noise levels increased significantly. For head scans, IQon had a noise level that was significantly lower than the iCT, on the other hand IQon showed noise levels significantly higher than the iCT for body scans. Still, these differences were well within the specified range of performance of iCT scanners. CONCLUSIONS: At equivalent dose levels, this study showed similar quality of conventional images acquired on iCT and IQon for medium-sized phantoms and slightly degraded image quality for (very) large phantoms at lower tube voltages on the IQon. Accordingly, it may be concluded that the introduction of a dual-layer detector neither compromises image quality of conventional images nor increases radiation dose for normal-sized patients, and slightly degrades dose efficiency for large patients at 120 kVp and lower tube voltages.


Asunto(s)
Fantasmas de Imagen , Tomografía Computarizada por Rayos X/instrumentación , Procesamiento de Imagen Asistido por Computador , Control de Calidad , Dosis de Radiación , Relación Señal-Ruido
4.
Int J Cardiovasc Imaging ; 34(8): 1265-1275, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29516228

RESUMEN

We investigated the feasibility and extent to which iodine concentration can be reduced in computed tomography angiography imaging of the aorta and coronary arteries using low tube voltage and virtual monochromatic imaging of 3 major dual-energy CT (DECT) vendors. A circulation phantom was imaged with dual source CT (DSCT), gemstone spectral imaging (GSI) and dual-layer spectral detector CT (SDCT). For each scanner, a reference scan was acquired at 120 kVp using routine iodine concentration (300 mg I/ml). Subsequently, scans were acquired at lowest possible tube potential (70, 80, 80 kVp, respectively), and DECT-mode (80/150Sn, 80/140 and 120 kVp, respectively) in arterial phase after administration of iodine (300, 240, 180, 120, 60, 30 mg I/ml). Objective image quality was evaluated using attenuation, CNR and dose corrected CNR (DCCNR) measured in the aorta and left main coronary artery. Average DCCNR at reference was 227.0, 39.7 and 60.2 for DSCT, GSI and SDCT. Maximum iodine concentration reduction without loss of DCCNR was feasible down to 180 mg I/ml (40% reduced) for DSCT (DCCNR 467.1) and GSI (DCCNR 46.1) using conventional CT low kVp, and 120 mg I/ml (60% reduced) for SDCT (DCCNR 171.5) using DECT mode. Low kVp scanning and DECT allows for 40-60% iodine reduction without loss in image quality compared to reference. Optimal scan protocol and to which extent varies per vendor. Further patient studies are needed to extend and translate our findings to clinical practice.


Asunto(s)
Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/administración & dosificación , Vasos Coronarios/diagnóstico por imagen , Yohexol/análogos & derivados , Fantasmas de Imagen , Angiografía por Tomografía Computarizada/normas , Estudios de Factibilidad , Humanos , Procesamiento de Imagen Asistido por Computador , Yohexol/administración & dosificación , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
5.
Eur Radiol ; 28(1): 143-150, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28695359

RESUMEN

OBJECTIVE: To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). METHODS: Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. RESULTS: 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CONCLUSIONS: CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. KEY POINTS: • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40-60% reduced dose.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Urolitiasis/diagnóstico por imagen , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Sistema Urinario/diagnóstico por imagen
6.
PLoS One ; 12(4): e0175714, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28410386

RESUMEN

BACKGROUND: To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). METHODS: Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced dose and reconstructed with filtered back projection (FBP) and IR. Objective image quality in terms of noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as subjective image quality were evaluated. RESULTS: Noise, SNR and CNR were improved with IR at routine and 52% reduced dose, compared to FBP at routine dose. The lowest dose level resulted in decreased objective image quality with both FBP and IR. Subjective image quality was excellent at all dose levels. CONCLUSION: IR resulted in improved objective image quality at routine dose and 52% reduced dose, while objective image quality deteriorated at 81% reduced dose. Subjective image quality was not affected by dose reduction.


Asunto(s)
Stents , Tomografía Computarizada por Rayos X , Algoritmos , Niño , Humanos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Relación Señal-Ruido
7.
Eur Radiol ; 27(10): 4351-4359, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28374079

RESUMEN

OBJECTIVES: To investigate the accuracy of bone mineral density (BMD) quantification using dual-layer spectral detector CT (SDCT) at various scan protocols. METHODS: Two validated anthropomorphic phantoms containing inserts of 50-200 mg/cm3 calcium hydroxyapatite (HA) were scanned using a 64-slice SDCT scanner at various acquisition protocols (120 and 140 kVp, and 50, 100 and 200 mAs). Regions of interest (ROIs) were placed in each insert and mean attenuation profiles at monochromatic energy levels (90-200 keV) were constructed. These profiles were fitted to attenuation profiles of pure HA and water to calculate HA concentrations. For comparison, one phantom was scanned using dual energy X-ray absorptiometry (DXA). RESULTS: At both 120 and 140 kVp, excellent correlations (R = 0.97, P < 0.001) were found between true and measured HA concentrations. Mean error for all measurements at 120 kVp was -5.6 ± 5.7 mg/cm3 (-3.6 ± 3.2%) and at 140 kVp -2.4 ± 3.7 mg/cm3 (-0.8 ± 2.8%). Mean measurement errors were smaller than 6% for all acquisition protocols. Strong linear correlations (R2 ≥ 0.970, P < 0.001) with DXA were found. CONCLUSIONS: SDCT allows for accurate BMD quantification and potentially opens up the possibility for osteoporosis evaluation and opportunistic screening in patients undergoing SDCT for other clinical indications. However, patient studies are needed to extend and translate our findings. KEY POINTS: • Dual-layer spectral detector CT allows for accurate bone mineral density quantification. • BMD measurements on SDCT are strongly linearly correlated to DXA. • SDCT, acquired for several indications, may allow for evaluation of osteoporosis. • This potentially opens up the possibility for opportunistic osteoporosis screening.


Asunto(s)
Densidad Ósea , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Absorciometría de Fotón , Humanos , Osteoporosis/diagnóstico por imagen
8.
Eur Radiol ; 27(9): 3677-3686, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28124106

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the feasibility and accuracy of dual-layer spectral detector CT (SDCT) for the quantification of clinically encountered gadolinium concentrations. METHODS: The cardiac chamber of an anthropomorphic thoracic phantom was equipped with 14 tubular inserts containing different gadolinium concentrations, ranging from 0 to 26.3 mg/mL (0.0, 0.1, 0.2, 0.4, 0.5, 1.0, 2.0, 3.0, 4.0, 5.1, 10.6, 15.7, 20.7 and 26.3 mg/mL). Images were acquired using a novel 64-detector row SDCT system at 120 and 140 kVp. Acquisitions were repeated five times to assess reproducibility. Regions of interest (ROIs) were drawn on three slices per insert. A spectral plot was extracted for every ROI and mean attenuation profiles were fitted to known attenuation profiles of water and pure gadolinium using in-house-developed software to calculate gadolinium concentrations. RESULTS: At both 120 and 140 kVp, excellent correlations between scan repetitions and true and measured gadolinium concentrations were found (R > 0.99, P < 0.001; ICCs > 0.99, CI 0.99-1.00). Relative mean measurement errors stayed below 10% down to 2.0 mg/mL true gadolinium concentration at 120 kVp and below 5% down to 1.0 mg/mL true gadolinium concentration at 140 kVp. CONCLUSION: SDCT allows for accurate quantification of gadolinium at both 120 and 140 kVp. Lowest measurement errors were found for 140 kVp acquisitions. KEY POINTS: • Gadolinium quantification may be useful in patients with contraindication to iodine. • Dual-layer spectral detector CT allows for overall accurate quantification of gadolinium. • Interscan variability of gadolinium quantification using SDCT material decomposition is excellent.


Asunto(s)
Gadolinio/análisis , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Estudios de Factibilidad , Corazón , Reproducibilidad de los Resultados
9.
J Comput Assist Tomogr ; 41(1): 148-155, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27560017

RESUMEN

OBJECTIVE: This study aimed to determine the lowest radiation dose and iterative reconstruction level(s) at which computed tomography (CT)-based quantification of aortic valve calcification (AVC) and thoracic aortic calcification (TAC) is still feasible. METHODS: Twenty-eight patients underwent a cardiac CT and 20 patients a chest CT at 4 different dose levels (routine dose and approximately 40%, 60%, and 80% reduced dose). Data were reconstructed with filtered back projection, 3 iDose levels, and 3 iterative model-based reconstruction levels. Two observers scored subjective image quality. The AVC and TAC were quantified using mass and compared to the reference scan (routine dose reconstructed with filtered back projection). RESULTS: In cardiac CT at 0.35 mSv (60% reduced), all scans reconstructed with iDose (all levels) were diagnostic, calcification detection errors occurred in only 1 patient, and there were no significant differences in mass scores compared to the reference scan. Similar results were found for chest CT at 0.48 mSv (75% reduced) with iDose levels 4 and 6 and iterative model reconstruction levels 1 and 2. CONCLUSIONS: Iterative reconstruction enables AVC and TAC quantification on CT at submillisievert dose.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Exposición a la Radiación/prevención & control , Protección Radiológica/métodos , Tomografía Computarizada por Rayos X/métodos , Calcificación Vascular/diagnóstico por imagen , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Exposición a la Radiación/análisis , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Eur J Radiol ; 85(11): 2152-2159, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27776671

RESUMEN

PURPOSE: To determine the effect of model-based iterative reconstruction (IR) on coronary calcium quantification using different submillisievert CT acquisition protocols. METHODS: Twenty-eight patients received a clinically indicated non contrast-enhanced cardiac CT. After the routine dose acquisition, low-dose acquisitions were performed with 60%, 40% and 20% of the routine dose mAs. Images were reconstructed with filtered back projection (FBP), hybrid IR (HIR) and model-based IR (MIR) and Agatston scores, calcium volumes and calcium mass scores were determined. RESULTS: Effective dose was 0.9, 0.5, 0.4 and 0.2mSv, respectively. At 0.5 and 0.4mSv, differences in Agatston scores with both HIR and MIR compared to FBP at routine dose were small (-0.1 to -2.9%), while at 0.2mSv, differences in Agatston scores of -12.6 to -14.6% occurred. Reclassification of risk category at reduced dose levels was more frequent with MIR (21-25%) than with HIR (18%). CONCLUSIONS: Radiation dose for coronary calcium scoring can be safely reduced to 0.4mSv using both HIR and MIR, while FBP is not feasible at these dose levels due to excessive noise. Further dose reduction can lead to an underestimation in Agatston score and subsequent reclassification to lower risk categories. Mass scores were unaffected by dose reductions.


Asunto(s)
Calcinosis/diagnóstico por imagen , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Algoritmos , Calcinosis/patología , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Fantasmas de Imagen , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
11.
J Comput Assist Tomogr ; 40(4): 578-83, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27096400

RESUMEN

OBJECTIVE: The aim of the study was to determine the effects of dose reduction and iterative reconstruction (IR) on pulmonary nodule volumetry. METHODS: In this prospective study, 25 patients scheduled for follow-up of pulmonary nodules were included. Computed tomography acquisitions were acquired at 4 dose levels with a median of 2.1, 1.2, 0.8, and 0.6 mSv. Data were reconstructed with filtered back projection (FBP), hybrid IR, and model-based IR. Volumetry was performed using semiautomatic software. RESULTS: At the highest dose level, more than 91% (34/37) of the nodules could be segmented, and at the lowest dose level, this was more than 83%. Thirty-three nodules were included for further analysis. Filtered back projection and hybrid IR did not lead to significant differences, whereas model-based IR resulted in lower volume measurements with a maximum difference of -11% compared with FBP at routine dose. CONCLUSIONS: Pulmonary nodule volumetry can be accurately performed at a submillisievert dose with both FBP and hybrid IR.


Asunto(s)
Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Modelos Estadísticos , Dosis de Radiación , Protección Radiológica/métodos , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Tumoral
12.
Eur J Radiol ; 85(2): 346-51, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26781139

RESUMEN

OBJECTIVE: To evaluate the effect of radiation dose reduction and iterative reconstruction (IR) on the performance of computer-aided detection (CAD) for pulmonary nodules. METHODS: In this prospective study twenty-five patients were included who were scanned for pulmonary nodule follow-up. Image acquisition was performed at routine dose and three reduced dose levels in a single session by decreasing mAs-values with 45%, 60% and 75%. Tube voltage was fixed at 120 kVp for patients ≥ 80 kg and 100 kVp for patients < 80 kg. Data were reconstructed with filtered back projection (FBP), iDose(4) (levels 1,4,6) and IMR (levels 1-3). All noncalcified solid pulmonary nodules ≥ 4 mm identified by two radiologists in consensus served as the reference standard. Subsequently, nodule volume was measured with CAD software and compared to the reference consensus. The numbers of true-positives, false-positives and missed pulmonary nodules were evaluated as well as the sensitivity. RESULTS: Median effective radiation dose was 2.2 mSv at routine dose and 1.2, 0.9 and 0.6 mSv at respectively 45%, 60% and 75% reduced dose. A total of 28 pulmonary nodules were included. With FBP at routine dose, 89% (25/28) of the nodules were correctly identified by CAD. This was similar at reduced dose levels with FBP, iDose(4) and IMR. CAD resulted in a median number of false-positives findings of 11 per scan with FBP at routine dose (93% of the CAD marks) increasing to 15 per scan with iDose(4) (95% of the CAD marks) and 26 per scan (96% of the CAD marks) with IMR at the lowest dose level. CONCLUSION: CAD can identify pulmonary nodules at submillisievert dose levels with FBP, hybrid and model-based IR. However, the number of false-positive findings increased using hybrid and especially model-based IR at submillisievert dose while dose reduction did not affect the number of false-positives with FBP.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Programas Informáticos
13.
Br J Radiol ; 89(1058): 20150068, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26562096

RESUMEN

OBJECTIVE: To investigate the achievable radiation dose reduction for coronary CT angiography (CCTA) with iterative reconstruction (IR) in adults and the effects on image quality. METHODS: PubMed and EMBASE were searched, and original articles concerning IR for CCTA in adults using prospective electrocardiogram triggering were included. Primary outcome was the effective dose using filtered back projection (FBP) and IR. Secondary outcome was the effect of IR on objective and subjective image quality. RESULTS: The search yielded 1616 unique articles, of which 10 studies (1042 patients) were included. The pooled routine effective dose with FBP was 4.2 mSv [95% confidence interval (CI) 3.5-5.0]. A dose reduction of 48% to a pooled effective dose of 2.2 mSv (95% CI 1.3-3.1) using IR was reported. Noise, contrast-to-noise ratio and subjective image quality were equal or improved in all but one study, whereas signal-to-noise ratio was decreased in two studies with IR at reduced dose. CONCLUSION: IR allows for CCTA acquisition with an effective dose of 2.2 mSv with preserved objective and subjective image quality.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador , Relación Señal-Ruido
14.
J Cardiovasc Comput Tomogr ; 10(1): 69-75, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26342405

RESUMEN

OBJECTIVE: To assess the maximally achievable computed tomography (CT) dose reduction for coronary artery calcium (CAC) scoring with iterative reconstruction (IR) by using phantom-experiments and a systematical within-patient study. METHODS: Our local institutional review-board approved this study and informed consent was obtained from all participants. A phantom and patient study were conducted with 30 patients (23 men, median age 55.0 (52.0-56.0) years) who underwent 256-slice electrocardiogram-triggered CAC-scoring at four dose levels (routine, 60%, 40%, and 20%-dose) in a single session. Tube-voltage was 120 kVp, tube-current was lowered to achieve stated dose levels. Data were reconstructed with filtered back-projection (FBP) and three IR levels. Agatston, volume and mass scores were determined with validated software and compared using Wilcoxon signed ranks-tests. Subsequently, patient reclassification was analyzed. RESULTS: The phantom study showed that Agatston scores remained nearly stable with FBP between routine-dose and 40%-dose and increased substantially at lower dose. Twenty-three patients (77%) had coronary calcifications. For Agatston scoring, one 40%-dose and six 20%-dose FBP reconstructions were not interpretable due to noise. In contrast, with IR all reconstructions were interpretable. Median Agatston scores increased with FBP from 26.1 (5.2-192.2) at routine-dose to 60.5 (11.6-251.7) at 20% dose. However, IR lowered Agatston scores to 22.9 (5.9-195.5) at 20%-dose and strong IR (level 7) with Agatston reclassifications in 15%. CONCLUSION: IR allows for CAC-scoring radiation dose reductions of up to 80% resulting in effective doses between 0.15 and 0.18 mSv. At these dose-levels, reclassification-rates remain within 15% if the highest IR-level is applied.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Exposición a la Radiación/prevención & control , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Calcificación Vascular/diagnóstico por imagen , Algoritmos , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Exposición a la Radiación/análisis , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido
15.
Eur J Radiol ; 84(11): 2307-13, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26212557

RESUMEN

OBJECTIVES: Iterative reconstruction (IR) allows for dose reduction with maintained image quality in CT imaging. In this systematic review the reported effective dose reductions for chest CT and the effects on image quality are investigated. METHODS: A systematic search in PubMed and EMBASE was performed. Primary outcome was the reported local reference and reduced effective dose and secondary outcome was the image quality with IR. Both non contrast-enhanced and enhanced studies comparing reference dose with reduced dose were included. RESULTS: 24 studies were included. The median number of patients per study was 66 (range 23-200) with in total 1806 patients. The median reported local reference dose of contrast-enhanced chest CT with FBP was 2.6 (range 1.5-21.8) mSv. This decreased to 1.4 (range 0.4-7.3) mSv at reduced dose levels using IR. With non contrast-enhanced chest CT the dose decreased from 3.4 (range 0.7-7.8) mSv to 0.9 (range 0.1-4.5) mSv. Objective mage quality and diagnostic confidence and acceptability remained the same or improved with IR compared to FBP in most studies while data on diagnostic accuracy was limited. CONCLUSION: Radiation dose can be reduced to less than 2 mSv for contrast-enhanced chest CT and non contrast-enhanced chest CT is possible at a submillisievert dose using IR algorithms.


Asunto(s)
Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Algoritmos , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica
16.
AJR Am J Roentgenol ; 204(3): 645-53, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25714298

RESUMEN

OBJECTIVE. Radiation exposure from CT examinations should be reduced to a minimum in children. Iterative reconstruction (IR) is a method to reduce image noise that can be used to improve CT image quality, thereby allowing radiation dose reduction. This article reviews the use of hybrid and model-based IRs in pediatric CT and discusses the possibilities, advantages, and disadvantages of IR in pediatric CT and the importance of radiation dose reduction for CT of children. CONCLUSION. IR is a promising and potentially highly valuable technique that can be used to substantially reduce the amount of radiation in pediatric imaging. Future research should determine the maximum achievable radiation dose reduction in pediatric CT that is possible without a loss of diagnostic image quality.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Modelos Teóricos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Niño , Humanos
17.
Radiology ; 273(3): 695-702, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25153157

RESUMEN

PURPOSE: To determine the intervendor variability of Agatston scoring determined with state-of-the-art computed tomographic (CT) systems from the four major vendors in an ex vivo setup and to simulate the subsequent effects on cardiovascular risk reclassification in a large population-based cohort. MATERIALS AND METHODS: Research ethics board approval was not necessary because cadaveric hearts from individuals who donated their bodies to science were used. Agatston scores obtained with CT scanners from four different vendors were compared. Fifteen ex vivo human hearts were placed in a phantom resembling an average human adult. Hearts were scanned at equal radiation dose settings for the systems of all four vendors. Agatston scores were quantified semiautomatically with software used clinically. The ex vivo Agatston scores were used to simulate the effects of different CT scanners on reclassification of 432 individuals aged 55 years or older from a population-based study who were at intermediate cardiovascular risk based on Framingham risk scores. The Friedman test was used to evaluate overall differences, and post hoc analyses were performed by using the Wilcoxon signed-rank test with Bonferroni correction. RESULTS: Agatston scores differed substantially when CT scanners from different vendors were used, with median Agatston scores ranging from 332 (interquartile range, 114-1135) to 469 (interquartile range, 183-1381; P < .05). Simulation showed that these differences resulted in a change in cardiovascular risk classification in 0.5%-6.5% of individuals at intermediate risk when a CT scanner from a different vendor was used. CONCLUSION: Among individuals at intermediate cardiovascular risk, state-of the-art CT scanners made by different vendors produced substantially different Agatston scores, which can result in reclassification of patients to the high- or low-risk categories in up to 6.5% of cases.


Asunto(s)
Calcinosis/clasificación , Calcinosis/diagnóstico por imagen , Enfermedad Coronaria/clasificación , Enfermedad Coronaria/diagnóstico por imagen , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/instrumentación , Cadáver , Humanos , Fantasmas de Imagen , Medición de Riesgo , Factores de Riesgo
18.
J Comput Assist Tomogr ; 38(6): 815-23, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24983438

RESUMEN

OBJECTIVE: We evaluated the effects of hybrid and model-based iterative reconstruction (IR) algorithms from different vendors at multiple radiation dose levels on image quality of chest phantom scans. METHODS: A chest phantom was scanned on state-of-the-art computed tomography scanners from 4 vendors at 4 dose levels (4.1 mGy, 3.0 mGy, 1.9 mGy, and 0.8 mGy). All data were reconstructed with filtered back projection (FBP) and reduced-dose data also with IR (iDose4, Adaptive Iterative Dose Reduction 3D, Adaptive Statistical Iterative Reconstruction, Sinogram-Affirmed Iterative Reconstruction, prototype Iterative Model Reconstruction, and Veo). Computed tomography numbers and noise were measured in the spine and lungs. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated and differences were analyzed with the Friedman test. RESULTS: For all vendors, radiation dose reduction with FBP resulted in significantly increased noise levels (≤148%) as well as decreased SNR (≤57%) and CNR (≤58%) (P < 0.001). Conversely, IR resulted in decreased noise levels (≤48%) as well as increased SNR (≤94%) and CNR (≤94%). The SNRs and CNRs of the model-based algorithms at 80% reduced dose were similar to reference-dose FBP. CONCLUSIONS: Hybrid IR algorithms have the potential to reduce radiation dose with 27% to 54% and model-based IR algorithms with up to 80%.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/normas , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador/instrumentación , Dosis de Radiación , Tomografía Computarizada por Rayos X/instrumentación
19.
Eur Radiol ; 24(9): 2201-12, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24889996

RESUMEN

OBJECTIVES: To analyse the effects of radiation dose reduction and iterative reconstruction (IR) algorithms on coronary calcium scoring (CCS). METHODS: Fifteen ex vivo human hearts were examined in an anthropomorphic chest phantom using computed tomography (CT) systems from four vendors and examined at four dose levels using unenhanced prospectively ECG-triggered protocols. Tube voltage was 120 kV and tube current differed between protocols. CT data were reconstructed with filtered back projection (FBP) and reduced dose CT data with IR. CCS was quantified with Agatston scores, calcification mass and calcification volume. Differences were analysed with the Friedman test. RESULTS: Fourteen hearts showed coronary calcifications. Dose reduction with FBP did not significantly change Agatston scores, calcification volumes and calcification masses (P > 0.05). Maximum differences in Agatston scores were 76, 26, 51 and 161 units, in calcification volume 97, 27, 42 and 162 mm(3), and in calcification mass 23, 23, 20 and 48 mg, respectively. IR resulted in a trend towards lower Agatston scores and calcification volumes with significant differences for one vendor (P < 0.05). Median relative differences between reference FBP and reduced dose IR for Agatston scores remained within 2.0-4.6%, 1.0-5.3%, 1.2-7.7% and 2.6-4.5%, for calcification volumes within 2.4-3.9%, 1.0-5.6%, 1.1-6.4% and 3.7-4.7%, for calcification masses within 1.9-4.1%, 0.9-7.8%, 2.9-4.7% and 2.5-3.9%, respectively. IR resulted in increased, decreased or similar calcification masses. CONCLUSIONS: CCS derived from standard FBP acquisitions was not affected by radiation dose reductions up to 80%. IR resulted in a trend towards lower Agatston scores and calcification volumes. KEY POINTS: In this ex vivo study, radiation dose could be reduced by 80% for coronary calcium scoring. Iterative reconstruction resulted in a trend towards lower Agatston scores and calcification volumes. Caution should be taken for coronary calcium scoring with iterative reconstruction.


Asunto(s)
Algoritmos , Calcinosis/diagnóstico por imagen , Calcio/análisis , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/química , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Cadáver , Calcinosis/metabolismo , Enfermedad de la Arteria Coronaria/metabolismo , Humanos , Fantasmas de Imagen , Dosis de Radiación , Reproducibilidad de los Resultados
20.
Int J Cardiovasc Imaging ; 30(6): 1125-33, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24794292

RESUMEN

PURPOSE: To determine the influence of dose reduction on coronary calcium scoring using hybrid and model-based iterative reconstruction (IR) techniques. METHODS: Fifteen ex vivo hearts were scanned in a phantom representing an average adult person at routine dose and three levels of dose reduction; 27, 55 and 82% reduced-dose, respectively. All images were reconstructed using filtered back-projection (FBP), hybrid IR (iDose4, levels 1, 4 and 7) as well as model-based IR iterative model reconstruction (IMR, levels 1, 2 and 3). Agatston, mass and volume scores found with iDose4 and IMR were compared to FBP reconstruction (routine dose) as well as objective image quality. RESULTS: With FBP calcium scores remained unchanged at 82% reduced dose. With IR Agatston scores differed significantly at routine dose, using IMR level 3 and iDose4 level 7, and at 82% reduced dose, using IMR levels 1-3 and iDose4 level 7. The maximum median difference was 5.3%. Mass remained unchanged at reduced dose levels while volume was significantly lower at 82% reduced dose with IMR (maximum median difference 5.0%). Objective image quality improved with IR, at 82% reduced dose the CNR of iDose4 level 7 was similar to the reference dose CNR, and IMR levels 1-3 resulted in an even higher CNR. CONCLUSION: Calcium scores were not affected by radiation-dose reduction with FBP and low levels of hybrid IR. Objective image quality increased significantly using hybrid and model-based IR. Therefore low level hybrid IR has the potential to reduce radiation-dose of coronary calcium scoring with up to 82%.


Asunto(s)
Algoritmos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada Multidetector , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Calcificación Vascular/diagnóstico por imagen , Angiografía Coronaria/instrumentación , Humanos , Tomografía Computarizada Multidetector/instrumentación , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad