Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 180
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Heart Rhythm ; 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39288881

RESUMEN

BACKGROUND: Risk stratification in patients with Brugada syndrome (BrS) is challenging, especially in those at intermediate risk. The Predicting Arrhythmic evenT (PAT) score has recently been demonstrated to be excellent for predicting future arrhythmic events in patients without prior ventricular fibrillation (VF). However, validation studies are lacking. OBJECTIVE: This study aimed to assess the performance of a novel risk stratification model in predicting future VF events in patients with BrS in a Japanese multicenter cohort. METHODS: The PAT score was calculated for 413 patients with BrS (mean age, 50.9±13.6 years; 395 men) from 59 hospitals in Japan, including 314 patients without prior VF. The incidence of developing VF during the follow-up period was investigated. RESULTS: During the 106.8-month follow-up period, 54 patients (13.1%) experienced VF events. Of the 314 patients without prior VF at enrollment, 14 (4.5%) experienced VF events. The incidence of VF events during the follow-up period was significantly higher in patients with PAT scores ≥10 than in those with scores <10 (41/173 [23.7%] vs. 13/240 [5.4%], p<0.0001) in the total cohort. No difference was observed in the incidence of VF events between patients with PAT scores ≥10 and <10 among the 314 patients without prior VF (6/86 [7.0%] vs. 8/228 [3.5%], p=0.22). PAT scores ≥10 predicted future VF events with a sensitivity and specificity of 42.9% and 73.3%, respectively. CONCLUSION: This Japanese multicenter registry demonstrated that the novel risk stratification model could not accurately predict future VF events in patients with BrS, but without prior VF.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39188036

RESUMEN

BACKGROUND: Safety data of the latest radiofrequency (RF) technologies during atrial fibrillation (AF) ablation in real-world clinical practice are limited. OBJECTIVES: We sought to evaluate the acute procedural safety of the four latest ablation catheters commonly used for AF ablation. METHODS: A total of 3957 AF ablation procedures performed between January 2022 and December 2023 at 20 centers with either the THERMOCOOL SMARTTOUCH SF (STSF), TactiCath (TC), QDOT Micro (QDM), or TactiFlex (TF) were retrospectively analyzed. RESULTS: In total, QDM, STSF, TF, and TC were used in 343 (8.7%), 1793 (45.3%), 1121 (28.4%), and 700(17.7%) procedures. Among 2406 index procedures, electrical pulmonary vein isolations were successfully achieved in 99.5%. Despite similar total procedure times in the four groups, the total fluoroscopic time was significantly shorter for QDM/STSF with CARTO than TF/TC with EnSite (18.7 ± 14 vs. 27.6 ± 20.6 min, p < .001) and longest in the TF group. The incidence of cardiac tamponade was 0.7% (0.5% and 0.9% during index and redo procedures, 0.8% and 0.3% for paroxysmal and non-paroxysmal AF) and was significantly lower for QDM/STSF than TF/TC (0.2% vs. 1.1%, p = .008) and highest in the TF group. The incidence of cardiac tamponade was higher for TF than TC and STSF than QDM. In the multivariate analysis, TF/TC with EnSite was a significant independent predictor of cardiac tamponade during both the index (odds ratio [OR] = 4.8, 95% confidence interval [CI] = 1.3-17.5, p = .02) and all procedures (OR = 3.0, 95% CI = 1.3-7.2, p = .01). CONCLUSIONS: The incidence of cardiac tamponade and the fluoroscopic time during AF ablation significantly differed among the latest RF catheters and mapping systems in real-world clinical practice.

4.
Heart Rhythm O2 ; 5(5): 301-306, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38840770

RESUMEN

Background: Pulmonary vein isolation (PVI) with cryoballoon technology is a well-established therapy for treatment of atrial fibrillation (AF). Recently, a size-adjustable cryoballoon (POLARxTM FIT) that enables delivery in a standard 28-mm or an expanded 31-mm size was introduced. Objective: The purpose of this study was to perform a randomized clinical trial to evaluate the safety and efficacy of this novel cryoballoon compared to the conventional cryoballoon. Methods: The CONTRAST-CRYO II trial is a multicenter, prospective, open-label, randomized controlled trial in which 214 patients with paroxysmal AF will be randomized 1:1 to cryoballoon ablation with either a conventional cryoballoon (Arctic Front AdvanceTM Pro) or a size-adjustable cryoballoon (POLARx FIT). The study was approved by the Institutional Review Boards at all investigational sites and has been registered in the UMIN Clinical Trials Registry (UMIN000052500). Results: The primary endpoint of this study will be the incidence of phrenic nerve injury. Secondary endpoints include procedural success, chronic success through 12 months, procedure-related adverse events, biophysiological parameters during applications for each pulmonary vein (PV), total procedural and fluoroscopy times, level of PVI and isolation area, and probability of non-PV foci initiating AF. Conclusion: The CONTRAST-CRYO II trial is a multicenter, prospective, randomized controlled trial designed to assess the safety and efficacy of the POLARx FIT vs the Arctic Front Advance Pro. The findings from this trial will provide additional utility data on the efficacy of the size-adjustable cryoballoon for isolating PVs in patients with paroxysmal AF.

5.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38588039

RESUMEN

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Asunto(s)
Fibrilación Atrial , Criocirugía , Traumatismos de los Nervios Periféricos , Nervio Frénico , Venas Pulmonares , Sistema de Registros , Humanos , Nervio Frénico/lesiones , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Venas Pulmonares/cirugía , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Estudios Prospectivos , Incidencia , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/prevención & control , Persona de Mediana Edad , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
7.
J Cardiovasc Electrophysiol ; 35(4): 701-707, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38329163

RESUMEN

INTRODUCTION: Most patients with Brugada syndrome (BrS) are first diagnosed in their 40s, with sudden cardiac death (SCD) often occurring in their 50s. Ventricular fibrillation (VF) may occur in some patients with BrS despite having been asymptomatic for a long period. This study aimed to assess the incidence and risk factors for late life-threatening arrhythmias in patients with BrS. METHODS: Patients with BrS (n = 523; mean age, 51 ± 13 years; male, n = 497) were enrolled. The risk of late life-threatening arrhythmia was investigated in 225 patients who had experienced no cardiac events (CEs: SCD or ventricular tachyarrhythmia) for at least 10 years after study enrollment. The incidence of CEs during the follow-up period was examined. RESULTS: During the follow-up of the 523 patients, 59 (11%) experienced CEs. The annual incidences of CEs were 2.87%, 0.77%, and 0.09% from study enrollment to 3, 3-10, and after 10 years, respectively. Among 225 patients who had experienced no CEs for at least 10 years after enrollment, four patients (1.8%) subsequently experienced CEs. Kaplan-Meier analysis revealed significant differences in the incidence of late CEs between patients with and without a history of symptoms (p = .032). The positive and negative predictive values of late CEs for the programmed electrical stimulation (PES) test were 2.9% and 100%, respectively. CONCLUSION: Our results suggest that patients with BrS who are asymptomatic and have no ventricular tachycardia/VF inducibility by PES are at extremely low risk of experiencing late life-threatening arrhythmias.


Asunto(s)
Síndrome de Brugada , Humanos , Masculino , Adulto , Persona de Mediana Edad , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/complicaciones , Estudios de Seguimiento , Japón/epidemiología , Electrocardiografía/métodos , Arritmias Cardíacas/complicaciones , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología
8.
Int J Cardiol Heart Vasc ; 50: 101326, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38192687

RESUMEN

Background: The POLARx FIT system (Boston Scientific, MA, USA) is a novel cryoballoon (CB) ablation technology in which the balloon diameter can be expanded from 28 to 31 mm. The aim of this study was to compare the benefits and safety of the new POLARx FIT system to those of the existing POLARx system currently in use for pulmonary vein (PV) isolation (PVI) in patients with atrial fibrillation. Methods: The first 70 consecutive patients who underwent CB-based PVI with the POLARx FIT system were retrospectively compared with 200 consecutive patients treated with the POLARx system at Sakakibara Heart Institute from October 2021 to May 2023. Results: The POLARx FIT system yielded a higher mean ± standard deviation nadir temperature in the right inferior PV (-59.2 ± 5.29 °C vs. - 62.0 ± 5.08 °C, p = 0.006), but this required a balloon size reduction to 28 mm in 30 % of cases. No significant differences were detected in the time to isolation and thaw time of any PV between the two groups. After the CB-based PVI procedure, no residual PV carina potentials were observed with the POLARx FIT system, whereas 4/20 were with the POLARx system (p = 0.04). Conclusions: The POLARx FIT system had comparable effectiveness and safety to the basic POLARx system. This technology may improve the ablation area, including the PV carina. However, the 31-mm balloon alone was not sufficient to isolate certain PVs.

9.
Clin Cardiol ; 47(1): e24164, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37822107

RESUMEN

BACKGROUND: A left atrial posterior wall isolation (LAPWI) is one of the atrial fibrillation (AF) ablation strategies. HYPOTHESIS: We hypothesized that an additional empirical LAPWI would increase the freedom from recurrent atrial arrhythmias as compared to standard AF ablation in persistent AF patients. METHODS: The CORNERSTONE AF study is a prospective, randomized, multicenter study investigating patients with AF persisting for >7 days and <3 years undergoing first-time AF ablation. They will be randomized to pulmonary vein isolation (PVI) or PVI + LAPWI in a 1:1 manner. Although PVI can be performed with either radiofrequency catheters or cryoballoons, only radiofrequency catheters will be permitted to achieve LAPWIs. Additional focal ablation targeting non-pulmonary vein triggers will be allowed. A total of 516 patients will be enrolled in 17 centers between August 2022 and February 2024 based on the calculation with 80% power, considering the assumption that 65% and 75% of the PVI and PVI + LAPWI group patients will be free from atrial arrhythmia recurrence 18-months postprocedure (10% of dropout). The primary endpoint is freedom from documented atrial arrhythmias 18 months postsingle procedures. Clinical follow-up will include 7-day ambulatory electrocardiograms and routine outpatient consultations by electrophysiologists at 1, 3, 6, 9, 12, and 18 months postprocedure. RESULTS: As of August 2023, a total of 331 patients (68 ± 9 years, 270 men, 43 longstanding persistent AF) have been enrolled. CONCLUSIONS: The CORNERSTONE AF study is a prospective, randomized, multicenter trial designed to evaluate the efficacy and safety of an adjunctive empirical LAPWI following standard AF ablation in persistent AF patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos , Estudios Multicéntricos como Asunto , Estudios Prospectivos , Venas Pulmonares/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Resultado del Tratamiento
10.
Pacing Clin Electrophysiol ; 47(1): 131-138, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38010718

RESUMEN

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are occasionally used in combination with other cardiac implantable electronic devices (CIEDs). However, whether the incidence of inappropriate shock increases in patients with S-ICDs and concomitant CIEDs remains unclear. This study aimed to investigate the association between the concomitant use of CIEDs and the incidence of inappropriate shock in patients with current-generation S-ICDs. METHODS: A total of 127 consecutive patients received an S-ICD. Patients were assigned to two groups depending on concomitant use of CIEDs at the time of S-ICD implantation: patients without other CIEDs (non-combined group, 106 patients) and patients with other CIEDs (combined group, 21 patients). CIEDs included pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy pacemakers, and cardiac resynchronization therapy defibrillators. The primary outcome was inappropriate shock, defined as a shock other than ventricular arrhythmia. Hazard ratios and 95% confidence intervals were calculated using a time-varying Cox proportional hazards model which was adjusted for age because age differed between the groups and could be a confounder. RESULTS: During a median follow-up period of 2.2 years (interquartile range, 1.0-3.4 years), inappropriate shock events occurred in 17 (16%) and five (19%) patients of the non-combined and combined groups, respectively. While the age-adjusted hazard ratio for inappropriate shock was 24% higher in the combined than in the non-combined group (hazard ratio = 1.24, 95% confidence interval, 0.39-3.97), this difference was insignificant (p = .71). CONCLUSION: The incidence of inappropriate shock did not differ between patients with and without concomitant use of CIEDs, suggesting that S-ICDs could potentially be combined with other CIEDs without increasing the number of inappropriate shocks. Further studies are warranted to confirm the safety and feasibility of concomitant use of S-ICDs and CIEDs.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Desfibriladores Implantables/efectos adversos , Estudios de Cohortes , Incidencia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Resultado del Tratamiento
11.
J Interv Card Electrophysiol ; 67(1): 5-12, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38087145

RESUMEN

BACKGROUND: Single-shot pulmonary vein isolation (PVI) utilizing cryothermal energy is an effective and safe treatment for atrial fibrillation (AF) patients. A novel cryoballoon system, POLARx™, has been recently introduced. The aim of this study was to compare the efficacy, safety, and biophysical parameters of PVI between the novel cryoballoon system, POLARx™, and the standard cryoballoon system, Arctic Front Advance Pro™ (AFA-Pro), in patients with paroxysmal AF. METHODS: The CONTRAST-CRYO trial is a prospective, multicenter, open-label, randomized controlled study performed at seven large cardiac centers. This study was approved by the central ethics committee or the local ethics committee of each participating hospital and has been registered at UMIN Clinical Trials Registry (UMIN000049948). The trial will assign 200 patients with paroxysmal AF undergoing PVI to POLARx™ and AFA-Pro in a 1:1 randomization. The primary endpoint is the one-shot acute success rate of the right inferior pulmonary vein. Second endpoints include freedom from documented atrial fibrillation, atrial flutter, or atrial tachycardia without antiarrhythmic drugs at 12 months after the procedure, freedom from re-do procedures, the incidence of procedure-related adverse events, freezing duration, and the biophysical parameters during applications for each PV, total procedure and fluoroscopy time, and PVI durability during re-do procedures. CONCLUSION: The CONTRAST-CRYO trial is a prospective, multicenter, randomized study designed to elucidate the difference in the efficacy, safety, and biophysical parameters between POLARx™ and AFA-Pro in paroxysmal AF patients undergoing PVI. The findings from this trial may provide a valuable indication for selecting the optimal cryoballoon system. CLINICAL TRIAL REGISTRATION:  UMIN000049948.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Estudios Prospectivos , Criocirugía/métodos , Antiarrítmicos , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Recurrencia , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
12.
Front Cardiovasc Med ; 10: 1278603, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37965084

RESUMEN

Background: Symptomatic gastric hypomotility (SGH) is a rare but major complication of atrial fibrillation (AF) ablation, but data on this are scarce. Objective: We compared the clinical course of SGH occurring with different energy sources. Methods: This multicenter study retrospectively collected the characteristics and clinical outcomes of patients with SGH after AF ablation. Results: The data of 93 patients (67.0 ± 11.2 years, 68 men, 52 paroxysmal AF) with SGH after AF ablation were collected from 23 cardiovascular centers. Left atrial (LA) ablation sets included pulmonary vein isolation (PVI) alone, a PVI plus a roof-line, and an LA posterior wall isolation in 42 (45.2%), 11 (11.8%), and 40 (43.0%) patients, respectively. LA ablation was performed by radiofrequency ablation, cryoballoon ablation, or both in 38 (40.8%), 38 (40.8%), and 17 (18.3%) patients, respectively. SGH diagnoses were confirmed at 2 (1-4) days post-procedure, and 28 (30.1%) patients required re-hospitalizations. Fasting was required in 81 (92.0%) patients for 4 (2.5-5) days; the total hospitalization duration was 11 [7-19.8] days. After conservative treatment, symptoms disappeared in 22.3% of patients at 1 month, 48.9% at 2 months, 57.6% at 3 months, 84.6% at 6 months, and 89.7% at 12 months, however, one patient required surgery after radiofrequency ablation. Symptoms persisted for >1-year post-procedure in 7 patients. The outcomes were similar regardless of the energy source and LA lesion set. Conclusions: The clinical course of SGH was similar regardless of the energy source. The diagnosis was often delayed, and most recovered within 6 months, yet could persist for over 1 year in 10%.

13.
Fukushima J Med Sci ; 69(1): 11-20, 2023 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-36990790

RESUMEN

OBJECTIVES: Methotrexate (MTX) is associated with extensive side effects, including myelosuppression, interstitial pneumonia, and infection. It is, therefore, critical to establish whether its administration is required after achieving remission with tocilizumab (TCZ) and MTX combination therapy in patients with rheumatoid arthritis (RA). Therefore, the aim of this multicenter, observational, cohort study was to evaluate the feasibility of MTX discontinuation for the safety of these patients. METHODS: Patients with RA were administered TCZ, with or without MTX, for 3 years; those who received TCZ+MTX combination therapy were selected. After remission was achieved, MTX was discontinued without flare development in one group (discontinued [DISC] group, n = 33) and continued without flare development in another group (maintain [MAIN] group, n = 37). The clinical efficacy of TCZ+MTX therapy, patient background characteristics, and adverse events were compared between groups. RESULTS: The disease activity score in 28 joints-erythrocyte sedimentation rate (DAS28-ESR) at 3, 6, and 9 months was significantly lower in the DISC group (P < .05, P < .01, and P < .01, respectively). Further, the DAS28-ESR remission rate at 6 and 9 months and Boolean remission rate at 6 months were significantly higher in the DISC group (P < .01 for all). Disease duration was significantly longer in the DISC group (P < .05). Furthermore, the number of patients with stage 4 RA was significantly higher in the DISC group (P < .01). CONCLUSIONS: Once remission was achieved, MTX was discontinued in patients who responded favorably to TCZ+MTX therapy, despite the prolonged disease duration and stage progression.


Asunto(s)
Antirreumáticos , Artritis Reumatoide , Humanos , Metotrexato/efectos adversos , Antirreumáticos/efectos adversos , Estudios de Cohortes , Estudios de Factibilidad , Quimioterapia Combinada , Artritis Reumatoide/tratamiento farmacológico , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 34(2): 337-344, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36423234

RESUMEN

INTRODUCTION: Spatial characteristics of localized sources of persistent atrial fibrillation (AF) identified by unipolar-based panoramic mapping software (CARTOFINDER) remain unclear. We evaluated spatial characteristics of bi-atrial AF localized sources in relation to complex fractionated atrial electrocardiograms (CFAEs) and atrial low voltage area (LVAs) (≤0.35 mV during AF). METHODS AND RESULTS: Twenty consecutive patients with persistent AF underwent bi-atrial voltage, CFAE, and CARTOFINDER mapping before the beginning of ablation (18 [90%] patients, initial procedure; 2 [10%] patients, repeat procedure). CFAEs were recorded using the interval confidence level (ICL) mode and defined as sites with a confidence level of ≥80% of maximal ICL number. We elucidated the following: (1) differences in the rate of AF localized sources and CFAEs inside or outside the atrial LVAs; (2) distribution of AF localized sources and CFAEs; and (3) distance between the closest points of AF localized sources and CFAEs. A total of 270 AF localized sources and 486 CFAEs were identified in 20 patients. AF localized sources were confirmed more often outside atrial LVAs than CFAEs (71% vs. 46% outside LVA, p < .001). AF localized sources and CFAEs were diffusely distributed without any tendency in bi-atria. Mean distance between closest AF localized sources and CFAEs was 22 ± 8 mm. CONCLUSION: AF localized sources identified by CARTOFINDER are different therapeutic targets as compared to CFAEs and could be confirmed both inside and outside atrial LVAs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Algoritmos , Electrocardiografía/métodos
19.
J Arrhythm ; 38(3): 454-457, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35785377

RESUMEN

A 69-year-old woman with isolated cardiac sarcoidosis was hospitalized for frequent appropriate implantable converter defibrillator therapies for ventricular tachycardia (VT) despite of favorably controlled condition with oral prednisolone. The patient underwent urgent catheter ablation with CARTO 3D mapping system. Although the voltage map, activation map, and propagation map during VT could not visualize the tachycardia circuit, the coherent map clarified entrance and exit sites of the tachycardia circuit with slow or nonconducting (SNO) zones, which seemed like a figure-of-eight circuit. Considering the risk of VT termination or acceleration to rapid unstable VT, neither entrainment nor pacing studies were performed. The VT was terminated near the exit site of the isthmus where tiny pre-systolic potential was detected. Any diastolic potentials could not be detected. This meant that the critical isthmus might be located at the epicardium or deep incite of the left-ventricular myocardium where the coherent map showed as SNO zones. We should recognize coherent map as artificial that may represent VT circuit as if complete endocardial reentry even if not. The procedural time from mapping to termination of VT was only 22 minutes. The patient has been free from any cardiovascular events after the procedure. Coherent map might be feasible for revealing the critical isthmus of hemodynamically stable VTs without using electrophysiological techniques, including entrainment, pacing study, and voltage map during own beats, and would enable us to achieve successful VT ablation in a short time.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA