Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nanomaterials (Basel) ; 13(18)2023 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-37764571

RESUMEN

The design of non-buckling interconnects with thick sections has gained important applications in stretchable inorganic electronics due to their simultaneous achievement of high stretchability, low resistance, and low heat generation. However, at the same time, such a design sharply increased the tensile stiffness, which is detrimental to the conformal fit and skin comfort. Introducing the fractal design into the non-buckling interconnects is a promising approach to greatly reduce the tensile stiffness while maintaining other excellent performances. Here, a hierarchical theory is proposed for the tensile stiffness of the non-buckling fractal-inspired interconnects with an arbitrary shape at each order, which is verified by the finite element analysis. The results show that the tensile stiffness of the non-buckling fractal-inspired interconnects decreases with the increase in either the height/span ratio or the number of fractal orders but is not highly correlated with the ratio of the two adjacent dimensions. When the ratio of the two adjacent dimensions and height/span ratio are fixed, the tensile stiffness of the serpentine fractal-inspired interconnect is smaller than that of sinusoidal and zigzag fractal-inspired interconnects. These findings are of great significance for the design of non-buckling fractal-inspired interconnects of stretchable inorganic electronics.

2.
Micromachines (Basel) ; 13(7)2022 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-35888967

RESUMEN

Bionic electronic skin is a system that simulates human skin and has multiple perceptions. For pressure sensors, high measurement accuracy and wide measurement range restrict each other, and it is difficult to achieve high measurement accuracy and wide measurement range simultaneously. Therefore, the research and application of bionic tactile-pressure sensors are limited due to the mutual constraints of measurement accuracy and range. In this work, a flexible graphene piezoresistive tactile sensor based on a biomimetic structure that utilizes the piezoresistive properties of graphene was reported. The novel tactile-pressure sensor consists of a 2D graphene film tactile sensor and a 3D graphene foam pressure sensor that could achieve high accuracy and a wide-range measurement simultaneously. The testing results show that the measurement range of this sensor was in two intervals of 0-2 N and 2-40 N. For the 0-2 N measurement range, the sensitivity was 472.2 Ω/kPa, the force resolution was 0.01 N, and the response time was less than 40 ms. For the 2-40 N measurement range, the sensitivity was 5.05 kΩ/kPa, the force resolution was 1 N, and the response time was less than 20 ms. The new sensor can realize high-precision and large-scale force measurements and shows great application value in the field of medical instruments and artificial limbs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA