EuroIntervention ; 19(6): 502-511, 2023 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-37203860

RESUMEN

BACKGROUND: Prospective data about transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) patients are limited. AIMS: We aimed to evaluate the clinical impact of the Evolut PRO and R (34 mm) self-expanding prostheses in BAV patients and explore the impact of different computed tomography (CT) sizing algorithms in a prospective registry. METHODS: A total of 149 bicuspid patients were treated in 14 countries. The primary endpoint was the intended valve performance at 30 days. Secondary endpoints were 30-day and 1-year mortality, severe patient-prosthesis mismatch (PPM) and the ellipticity index at 30 days. All study endpoints were adjudicated according to Valve Academic Research Consortium 3 criteria. RESULTS: The mean Society of Thoracic Surgeons score was 2.6% (1.7-4.2). Type I L-R BAV was observed in 72.5% of the patients. Evolut valve sizes 29 and 34 mm were utilised in 49.0% and 36.9% of the cases, respectively. The 30-day cardiac death rate was 2.6%; the 1-year cardiac death rate was 11.0%. Valve performance at 30 days was observed in 142/149 (95.3%) patients. The mean aortic valve area post-TAVI was 2.1 (1.8-2.6) cm2, and the mean aortic gradient was 7.2 (5.4-9.5) mmHg. No patient had more than moderate aortic regurgitation at 30 days. PPM was observed in 13/143 (9.1%) surviving patients and was severe in 2 patients (1.6%). Valve function was maintained at 1 year. The mean ellipticity index remained 1.3 (interquartile range 1.2-1.4). Overall, 30-day and 1-year clinical and echocardiography outcomes were similar between the two sizing strategies. CONCLUSIONS: BIVOLUTX demonstrated a favourable bioprosthetic valve performance and good clinical outcomes after TAVI with the Evolut platform in patients with bicuspid aortic stenosis. No impact from the sizing methodology could be identified.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Enfermedad de la Válvula Aórtica Bicúspide/etiología , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Constricción Patológica , Resultado del Tratamiento , Diseño de Prótesis , Estudios Prospectivos , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Mitral/cirugía , Sistema de Registros , Muerte
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA