Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Ophthalmol Sci ; 4(5): 100475, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38881602

RESUMEN

Purpose: Putative microglia were recently detected using adaptive optics ophthalmoscopy in healthy eyes. Here we evaluate the use of nonconfocal adaptive optics scanning light ophthalmoscopy (AOSLO) for quantifying the morphology and motility of presumed microglia and other immune cells in eyes with retinal inflammation from uveitis and healthy eyes. Design: Observational exploratory study. Participants: Twelve participants were imaged, including 8 healthy participants and 4 posterior uveitis patients recruited from the clinic of 1 of the authors (M.H.E.). Methods: The Pittsburgh AOSLO imaging system was used with a custom-designed 7-fiber optical fiber bundle for simultaneous confocal and nonconfocal multioffset detection. The inner retina was imaged at several locations at multiple timepoints in healthy participants and uveitis patients to generate time-lapse images. Main Outcome Measures: Microglia and macrophages were manually segmented from nonconfocal AOSLO images, and their morphological characteristics quantified (including soma size, diameter, and circularity). Cell soma motion was quantified across time for periods of up to 30 minutes and their speeds were calculated by measuring their displacement over time. Results: A spectrum of cell morphologies was detected in healthy eyes from circular amoeboid cells to elongated cells with visible processes, resembling activated and ramified microglia, respectively. Average soma diameter was 16.1 ± 0.9 µm. Cell movement was slow in healthy eyes (0.02 µm/sec on average), but macrophage-like cells moved rapidly in some uveitis patients (up to 3 µm/sec). In an eye with infectious uveitis, many macrophage-like cells were detected; during treatment their quantity and motility decreased as vision improved. Conclusions: In vivo adaptive optics ophthalmoscopy offers promise as a potentially powerful tool for detecting and monitoring inflammation and response to treatment at a cellular level in the living eye. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
Am J Ophthalmol Case Rep ; 28: 101741, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36345414

RESUMEN

Purpose: To test the hypothesis that hyperreflective foci in central serous chorioretinopathy (CSCR) are autofluorescent and may represent macrophages that have engulfed outer retinal fluorophores from the retinal pigment epithelium (RPE) and photoreceptors. Methods: Enrolled subjects underwent spectral domain and swept-source optical coherence tomography, adaptive optics flood-illumination, and adaptive optics scanning laser ophthalmoscopy (AOSLO), including near-infrared autofluorescence (AO-IRAF). For the AO-IRAF imaging, retinal fluorophores were excited using 795 nm light and collected in an emission band from 814 to 850 nm. Results: In 2 of 3 eyes, a hyperautofluorescent signal was detected with an elliptical shape and punctate, granular aspects surrounded by a hypoautofluorescent halo. The size of these structures in the active case was measured to be 17 ± 4 µm in diameter, with at least 45 individual hyperautofluorescent foci identified from the AO-IRAF montage in the active stage of patient 2. In the asymptomatic case there were fewer structures visible (∼10) and their size was smaller (11 ± 4 µm). These hyper-AF foci were colocalized with hyperreflective foci on OCT and visible in simultaneously acquired confocal AOSLO images in active stage. The hyperautofluorescent foci in the patient with active CSCR disappeared coincident with clinical resolution. Conclusion and importance: We show here the first AO-IRAF images from patients with CSCR, demonstrating hyper-autofluorescent punctate foci, colocalized with hyper-reflective foci on confocal AOSLO images and in OCT. The autofluorescence of these foci may be driven by the accumulation of photoreceptor and RPE fluorophores within macrophages during the active stage of the disease.

3.
Biomed Opt Express ; 13(1): 117-132, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-35154858

RESUMEN

Previous work has shown that multi-offset detection in adaptive optics scanning laser ophthalmoscopy (AOSLO) can be used to image transparent cells such as retinal ganglion cells (RGCs) in monkeys and humans. Though imaging in anesthetized monkeys with high light levels produced high contrast images of RGCs, images from humans failed to reach the same contrast due to several drawbacks in the previous dual-wavelength multi-offset approach. Our aim here was to design and build a multi-offset detection pattern for humans at safe light levels that could reveal transparent cells in the retinal ganglion cell layer with a contrast and acquisition time approaching results only previously obtained in monkeys. Here, we present a new single-wavelength solution that allows for increased light power and eliminates problematic chromatic aberrations. Then, we demonstrate that a radial multi-offset detection pattern with an offset distance of 8-10 Airy Disk Diameter (ADD) is optimal to detect photons multiply scattered in all directions from weakly reflective retinal cells thereby enhancing their contrast. This new setup and image processing pipeline led to improved imaging of inner retinal cells, including the first images of microglia with multi-offset imaging in AOSLO.

4.
Eye (Lond) ; 36(10): 1878-1883, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34462582

RESUMEN

PURPOSE: Fundus autofluorescence (AF) using adaptive optics scanning laser ophthalmoscopy (AOSLO) enables morphometric analysis of individual retinal pigmented epithelial (RPE) cells. However, only a few excitation wavelengths in the visible and near-infrared have been evaluated. Visible light excitation (<600 nm) presents additional safety hazards and is uncomfortable for patients. Near-infrared excitation (>700 nm) overcomes those problems but introduces others, including decreased AF signal and cone signatures that obscure RPE structure. Here we investigated the use of an intermediate wavelength, 663 nm, for excitation and compared it to 795 nm. METHODS: Subjects were imaged using AOSLO equipped with a detection channel to collect AF emission between 814 and 850 nm. Two light sources (663 and 795 nm) were used to excite the retinal fluorophores. We recorded 90 s videos and registered them with custom software to integrate AF images for analysis. RESULTS: We imaged healthy eyes and an eye with pattern dystrophy. Similar AF microstructures were detected with each excitation source, despite ~4 times lower excitation power with 663 nm. The signal-to-noise values showed no meaningful difference between 663 nm and 795 nm excitation and a similar trend was observed for image contrast between the two excitation wavelengths. CONCLUSIONS: Lower light levels can be used with shorter wavelength excitation to achieve comparable images of the microstructure of the RPE as have been obtained using higher light levels at longer wavelengths. Further experiments are needed to fully characterize AF across spectrum and determine the optimal excitation and emission bandwidths that balance efficiency, patient comfort, and efficacy.


Asunto(s)
Retina , Células Fotorreceptoras Retinianas Conos , Células Epiteliales , Angiografía con Fluoresceína/métodos , Humanos , Oftalmoscopía/métodos , Imagen Óptica , Epitelio Pigmentado de la Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos
5.
Transl Vis Sci Technol ; 10(14): 19, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34928325

RESUMEN

Purpose: Drusen are dynamic sub-RPE deposits that are risk factors for late-stage age-related macular degeneration (AMD). Here we show a new imaging method using flood-illumination adaptive optics (FIAO) that reveal drusen with high contrast and resolution. Methods: A fovea-centered 4° × 4° FIAO image and eight surrounding images with gaze displaced by ±2° vertically and horizontally were acquired. Clinical color fundus and spectral-domain optical coherence tomography were acquired for clinical grading and comparison. Custom software registered overlapping FIAO images and fused the data statistically to generate a fovea-centered 4° × 4° gaze-dependent image. Our dataset included 15 controls (aged 31-72) and 182 eyes from 104 AMD patients (aged 56-92), graded as either normal aging (n = 7), and early (n = 12), intermediate (n = 108) and late AMD (n = 42); 27 had subretinal drusenoid deposits (SDDs), and 83 were imaged longitudinally. Results: No gaze varying structures were detected in young eyes. In aging eyes with no evidence of age-related changes, putative drusen <20 µm in diameter were visible. Gaze-dependent images revealed more drusen and many smaller drusen than visible in color fundus images. Longitudinal images showed expansion and fusion of drusen. SDDs were lower contrast, and RPE atrophy did not yield a consistent signal. Conclusions: Gaze-dependent imaging in a commercially available FIAO fundus camera combined with image registration and postprocessing permits visualization of drusen and their progression with high contrast and resolution. Translational Relevance: This new technique offers promise as a robust and sensitive method to detect, map, quantify, and monitor the dynamics of drusen in aging and AMD.


Asunto(s)
Iluminación , Drusas Retinianas , Inundaciones , Angiografía con Fluoresceína , Humanos , Oftalmoscopía , Drusas Retinianas/diagnóstico por imagen
6.
J Vis ; 21(13): 11, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34940825

RESUMEN

The purpose of this study was to evaluate fixational eye movements (FEMs) with high spatial and temporal resolution following concussion, where oculomotor symptoms and impairments are common. Concussion diagnosis was determined using current consensus guidelines. A retinal eye-tracking device, the tracking scanning laser ophthalmoscope (TSLO), was used to measure FEMs in adolescents and young adults following a concussion and in an unaffected control population. FEMs were quantified in two fixational paradigms: (1) when fixating on the center, or (2) when fixating on the corner of the TSLO imaging raster. Fixational saccade amplitude in recent concussion patients (≤ 21 days) was significantly greater, on average, in the concussion group (mean = 1.03°; SD = 0.36°) compared with the controls (mean = 0.82°; SD = 0.31°), when fixating on the center of the imaging raster (t = 2.87, df = 82, p = 0.005). These fixational saccades followed the main sequence and therefore also had greater peak velocity (t = 2.86, df = 82, p = 0.006) and peak acceleration (t = 2.80, df = 82, p = 0.006). These metrics significantly differentiated concussed from controls (AUC = 0.67-0.68, minimum p = 0.005). No group differences were seen for the drift metrics in either task or for any of the FEMs metrics in the corner-of-raster fixation task. Fixational saccade amplitudes were significantly different in the concussion group, but only when fixating on the center of the raster. This task specificity suggests that task optimization may improve differentiation and warrants further study. FEMs measured in the acute-to-subacute period of concussion recovery may provide a quick (<3 minutes), objective, sensitive, and accurate ocular dysfunction assessment. Future work should assess the impact of age, mechanism of injury, and post-concussion recovery on FEM alterations following concussion.


Asunto(s)
Movimientos Oculares , Fijación Ocular , Adolescente , Ojo , Humanos , Movimientos Sacádicos , Visión Ocular , Adulto Joven
7.
Front Med (Lausanne) ; 8: 769308, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34957148

RESUMEN

Torpedo maculopathy (TM) is a rare congenital defect of the retinal pigment epithelium (RPE). The RPE is often evaluated clinically using fundus autofluorescence (AF), a technique that visualizes RPE structure at the tissue level from the intrinsic AF of RPE fluorophores. TM lesions typically emit little or no AF, but this macroscopic assessment is unable to resolve the RPE cells, leaving the organization of the RPE cell mosaic in TM unknown. We used fluorescence adaptive optics scanning laser ophthalmoscopy (AOSLO) to show here for the first time the microscopic cellular-level structural alterations to the RPE cell mosaic in TM that underlie the tissue-level changes seen in conventional clinical imaging. We evaluated two patients with TM using conventional clinical imaging techniques and adaptive optics (AO) infrared autofluorescence (IRAF) in AOSLO. Confocal AOSLO revealed relatively normal cones outside the TM lesion but altered cone appearance within it and along its margins in both patients. We quantified cone topography and RPE cell morphometry from the fovea to the margin of the lesion in case 1 and found cone density to be within the normal range across the locations imaged. However, RPE morphometric analysis revealed disrupted RPE cells outside the margin of the lesion; the mean RPE cell area was greater than two standard deviations above the normative range up to approximately 1.5 mm from the lesion margin. Similar morphometric changes were seen to individual RPE cells in case 2. Multi-modal imaging with AOSLO reveals that RPE cells are abnormal in TM well beyond the margins of the characteristic TM lesion boundary defined with conventional clinical imaging. Since the TM fovea appears to be fully formed, with normal cone packing, it is possible that the congenital RPE defect in TM occurs relatively late in retinal development. This work demonstrates how cellular level imaging of the RPE can provide new insight into RPE pathologies, particularly for rare conditions such as TM.

8.
Biomed Opt Express ; 12(4): 2353-2372, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33996234

RESUMEN

Retinal image-based eye motion measurement from scanned ophthalmic imaging systems, such as scanning laser ophthalmoscopy, has allowed for precise real-time eye tracking at sub-micron resolution. However, the constraints of real-time tracking result in a high error tolerance that is detrimental for some eye motion measurement and imaging applications. We show here that eye motion can be extracted from image sequences when these constraints are lifted, and all data is available at the time of registration. Our approach identifies and discards distorted frames, detects coarse motion to generate a synthetic reference frame and then uses it for fine scale motion tracking with improved sensitivity over a larger area. We demonstrate its application here to tracking scanning laser ophthalmoscopy (TSLO) and adaptive optics scanning light ophthalmoscopy (AOSLO), and show that it can successfully capture most of the eye motion across each image sequence, leaving only between 0.1-3.4% of non-blink frames untracked, while simultaneously minimizing image distortions induced from eye motion. These improvements will facilitate precise measurement of fixational eye movements (FEMs) in TSLO and longitudinal tracking of individual cells in AOSLO.

9.
Sci Rep ; 10(1): 9561, 2020 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-32533046

RESUMEN

Retinal pigmented epithelial (RPE) cells are essential for maintaining normal visual function, especially in their role in the visual cycle, and are thought to be one of the first cell classes affected by age-related macular degeneration (AMD). Clinical imaging systems routinely evaluate the structure of the RPE at the tissue level, but cellular level information may provide valuable RPE biomarkers of health, aging and disease. In this exploratory study, participants were imaged with 795 nm excitation in adaptive optics scanning laser ophthalmoscopy (AOSLO) to observe the microstructure of the near-infrared autofluorescence (AO-IRAF) from the RPE layer in healthy retinas and patients with AMD. The expected hexagonal mosaic of RPE cells was only sometimes seen in normal eyes, while AMD patients exhibited highly variable patterns of altered AO-IRAF. In some participants, AO-IRAF structure corresponding to cones was observed, as we have demonstrated previously. In some AMD patients, marked alterations in the pattern of AO-IRAF could be seen even in areas where the RPE appeared relatively normal in clinical imaging modalities, such as spectral domain optical coherence tomography (SD-OCT). AO-IRAF imaging using AOSLO offers promise for better detection and understanding of early RPE changes in the course of AMD, potentially before clinical signs appear.


Asunto(s)
Angiografía con Fluoresceína/métodos , Degeneración Macular/patología , Células Fotorreceptoras Retinianas Conos/patología , Epitelio Pigmentado de la Retina/fisiopatología , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Estudios de Casos y Controles , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA