Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Open Heart ; 11(1)2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38538065

RESUMEN

OBJECTIVE: A paucity of data exists on how transcatheter aortic valve implantation (TAVI) practice has evolved in Ireland. This study sought to analyse temporal trends in patient demographics, procedural characteristics, and clinical outcomes at an Irish tertiary referral centre. METHODS: The prospective Mater TAVI database was divided into time tertiles based on when TAVI was performed: Group A, November 2008-April 2013; Group B, April 2013-September 2017; and Group C, September 2017-February 2022. Patient and procedural characteristics and clinical outcomes were compared across groups. RESULTS: A total of 1063 (Group A, 59; Group B, 268; and Group C:, 736) patients were treated with TAVI during the study period (mean age 81.1±7.4, mean Society of Thoracic Surgeons score 5.9±5.1).Conscious sedation (Group A, 0%; Group B, 59.9%; and Group C, 90.2%, p<0.001) and femoral artery access (Group A, 76.3%; Group B, 90.7%; and Group C, 96.6%, p<0.001) were used more frequently over time. The median length of hospital stay reduced from 9 days (IQR 7, 18) in Group A to 2 days (IQR 2, 3) in Group C. In-hospital death was numerically higher in Group A compared with Group C (6.8% vs 1.9%, p=0.078). At 1-year follow-up, the rate of death and/or stroke was similar in Group A and Group C (20.3% vs 12.0%, adjusted HR 1.49, 95% CI (0.59 to 3.74)). CONCLUSION: There was exponential growth in TAVI procedural volume during the study period. A minimalist approach to TAVI emerged, and this was associated with significantly shorter procedure duration and hospital stay. Clinical outcomes at 1-year follow-up did not change significantly over time.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Prospectivos , Centros de Atención Terciaria , Mortalidad Hospitalaria , Resultado del Tratamiento
2.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38180419

RESUMEN

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pandemias , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Resultado del Tratamiento , COVID-19/epidemiología , Sistema de Registros , Factores de Riesgo
3.
EuroIntervention ; 2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37946522

RESUMEN

BACKGROUND: The multicentre European Bifurcation Club Trial (EBC TWO) showed no significant differences in 12-month clinical outcomes between patients randomised to a provisional stenting strategy or systematic culotte stenting in non-left main true bifurcations. AIMS: This study aimed to investigate the 5-year clinical results of the EBC TWO Trial. METHODS: A total of 200 patients undergoing stent implantation for non-left main bifurcation lesions were recruited into EBC TWO. Inclusion criteria required a side branch diameter ≥2.5 mm and side branch lesion length >5 mm. Five-year follow-up was completed for 197 patients. The primary endpoint was the composite of all-cause mortality, myocardial infarction, or target vessel revascularisation. RESULTS: The mean side branch stent diameter was 2.7±0.3 mm and mean side branch lesion length was 10.3±7.2 mm. At 5-year follow-up, the primary endpoint occurred in 18.4% of provisional and 23.7% of systematic culotte patients (hazard ratio [HR] 0.75, 95% confidence interval [CI]: 0.41-1.38). No significant differences were identified individually for all-cause mortality (7.8% vs 7.2%, HR 1.11, 95% CI: 0.40-3.05), myocardial infarction (8.7% vs 13.4%, HR 0.64, 95% CI: 0.27-1.50) or target vessel revascularisation (6.8% vs 9.3%, HR 1.12, 95% CI: 0.37-3.34). Stent thrombosis rates were also similar (1.9% vs 3.1%, HR 0.63, 95% CI: 0.11-3.75). There was no significant interaction between the extent of side branch disease and the primary outcome (p=0.34). CONCLUSIONS: In large non-left main true bifurcation lesions, the use of a systematic culotte strategy showed no benefit over provisional stenting for the composite outcome of all-cause mortality, myocardial infarction, or target vessel revascularisation at 5 years. The stepwise provisional approach may be considered preferable for the majority of true coronary bifurcation lesions. CLINICALTRIALS: gov: NCT01560455.

4.
Interv Cardiol ; 18: e13, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37398870

RESUMEN

Transcatheter aortic valve implantation (TAVI) is an effective and established treatment for symptomatic aortic stenosis. However, there is a lack of consensus concerning the need for peri- and post-procedural anti-thrombotic medication. Contemporary guidelines recommend that anti-thrombotic therapy is balanced against a patient's bleeding risk following TAVI, but do not fully consider the evolving evidence base. The purpose of the Delphi panel recommendations presented here is to provide a consensus elicited from a panel of experts who regularly prescribe anti-thrombotic therapy post-TAVI. The goal was to address evidence gaps across four key topics: anti-thrombotic therapy (anti-platelet and/or anti-coagulant) in TAVI patients in sinus rhythm; anti-thrombotic therapy in TAVI patients with AF; direct oral anti-coagulants versus vitamin K antagonists; and the need for UK/Ireland specific guidance. This consensus statement aims to inform clinical decision-making by providing a concise, evidence-based summary of best practice for prescribing anti-thrombotic therapies following TAVI and highlights areas where further research is needed.

5.
Monaldi Arch Chest Dis ; 94(1)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37074089

RESUMEN

This study sought to compare the morbidity and mortality of redo aortic valve replacement (redo-AVR) versus valve-in-valve trans-catheter aortic valve implantation (valve-in-valve TAVI) for patients with a failing bioprosthetic valve. A multicenter UK retrospective study of redo-AVR or valve-in-valve TAVI for patients referred for redo aortic valve intervention due to a degenerated aortic bioprosthesis. Propensity score matching was performed for confounding factors. From July 2005 to April 2021, 911 patients underwent redo-AVR and 411 patients underwent valve-in-valve TAVI. There were 125 pairs for analysis after propensity score matching. The mean age was 75.2±8.5 years. In-hospital mortality was 7.2% (n=9) for redo-AVR versus 0 for valve-in-valve TAVI, p=0.002. Surgical patients suffered more post-operative complications, including intra-aortic balloon pump support (p=0.02), early re-operation (p<0.001), arrhythmias (p<0.001), respiratory and neurological complications (p=0.02 and p=0.03) and multi-organ failure (p=0.01). The valve-in-valve TAVI group had a shorter intensive care unit and hospital stay (p<0.001 for both). However, moderate aortic regurgitation at discharge and higher post-procedural gradients were more common after valve-in-valve TAVI (p<0.001 for both). Survival probabilities in patients who were successfully discharged from the hospital were similar after valve-in-valve TAVI and redo-AVR over the 6-year follow-up (log-rank p=0.26). In elderly patients with a degenerated aortic bioprosthesis, valve-in-valve TAVI provides better early outcomes as opposed to redo-AVR, although there was no difference in mid-term survival in patients successfully discharged from the hospital.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Reino Unido/epidemiología , Resultado del Tratamiento , Factores de Riesgo , Bioprótesis/efectos adversos
6.
Catheter Cardiovasc Interv ; 101(5): 932-942, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36924015

RESUMEN

BACKGROUND: With expansion of transcatheter aortic valve implantation (TAVI) into younger patients, valve durability is critically important. AIMS: We aimed to evaluate long-term valve function and incidence of severe structural valve deterioration (SVD) among patients ≥ 10-years post-TAVI and with echocardiographic follow-up at least 5-years postprocedure. METHODS: Data on patients who underwent TAVI from 2007 to 2011 were obtained from the UK TAVI registry. Patients with paired echocardiograms postprocedure and ≥5-years post-TAVI were included. Severe SVD was determined according to European task force guidelines. RESULTS: 221 patients (79.4 ± 7.3 years; 53% male) were included with median echocardiographic follow-up 7.0 years (range 5-13 years). Follow-up exceeded 10 years in 43 patients (19.5%). Valve types were the supra-annular self-expanding CoreValve (SEV; n = 143, 67%), balloon-expandable SAPIEN/XT (BEV; n = 67, 31%), Portico (n = 4, 5%) and unknown (n = 7, 3%). There was no difference between postprocedure and follow-up peak gradient in the overall cohort (19.3 vs. 18.4 mmHg; p = NS) or in those with ≥10-years follow-up (21.1 vs. 21.1 mmHg; p = NS). Severe SVD occurred in 13 patients (5.9%; median 7.8-years post-TAVI). Three cases (23.1%) were due to regurgitation and 10 (76.9%) to stenosis. Valve-related reintervention/death occurred in 5 patients (2.3%). Severe SVD was more frequent with BEV than SEV (11.9% vs. 3.5%; p = 0.02), driven by a difference in patients treated with small valves (BEV 28.6% vs. SEV 3.0%; p < 0.01). CONCLUSIONS: Hemodynamic function of transcatheter heart valves remains stable up to more than 10 years post-TAVI. Severe SVD occurred in 5.9%, and valve-related death/reintervention in 2.3%. Severe SVD was more common with BEV than SEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros , Reino Unido , Diseño de Prótesis
7.
Microvasc Res ; 147: 104480, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36690270

RESUMEN

OBJECTIVE: Coronary microvascular dysfunction (CMD) is a cause of ischaemia with non-obstructive coronary arteries (INOCA). It is notoriously underdiagnosed due to the need for invasive microvascular function testing. We hypothesized that systemic microvascular dysfunction could be demonstrated non-invasively in the microcirculation of the bulbar conjunctiva in patients with CMD. METHODS: Patients undergoing coronary angiography for the investigation of chest pain or dyspnoea, with physiologically insignificant epicardial disease (fractional flow reserve ≥0.80) were recruited. All patients underwent invasive coronary microvascular function testing. We compared a cohort of patients with evidence of CMD (IMR ≥25 or CFR <2.0); to a group of controls (IMR <25 and CFR ≥2.0). Conjunctival imaging was performed using a previously validated combination of a smartphone and slit-lamp biomicroscope. This technique allows measurement of vessel diameter and other indices of microvascular function by tracking erythrocyte motion. RESULTS: A total of 111 patients were included (43 CMD and 68 controls). There were no differences in baseline demographics, co-morbidities or epicardial coronary disease severity. The mean number of vessel segments analysed per patient was 21.0 ± 12.8 (3.2 ± 3.5 arterioles and 14.8 ± 10.8 venules). In the CMD cohort, significant reductions were observed in axial/cross-sectional velocity, blood flow, wall shear rate and stress. CONCLUSION: The changes in microvascular function linked to CMD can be observed non-invasively in the bulbar conjunctiva. Conjunctival vascular imaging may have utility as a non-invasive tool to both diagnose CMD and augment conventional cardiovascular risk assessment.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica , Humanos , Estudios Transversales , Estudios Prospectivos , Hemodinámica , Angiografía Coronaria/métodos , Vasos Coronarios , Microcirculación , Conjuntiva , Circulación Coronaria
8.
Cardiovasc Revasc Med ; 50: 26-33, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36707373

RESUMEN

BACKGROUND: Atherosclerotic heart disease often remains asymptomatic until presentation with a major adverse cardiovascular event. Primary preventive therapies improve outcomes, but conventional screening often misattributes risk. Vascular imaging can be utilised to detect atherosclerosis, but often involves ionising radiation. The conjunctiva is a readily accessible vascular network allowing non-invasive hemodynamic evaluation. AIM: To compare conjunctival microcirculatory function in patients with and without obstructive coronary artery disease. METHODS: We compared the conjunctival microcirculation of myocardial infarction patients (MI-cohort) to controls with no obstructive coronary artery disease (NO-CAD cohort). Conjunctival imaging was performed using a smartphone and slit-lamp biomicroscope combination. Microvascular indices of axial (Va) and cross-sectional (Vcs) velocity; blood flow rate (Q); and wall shear rate (WSR) were compared in all conjunctival vessels between 5 and 45 µm in diameter. RESULTS: A total of 127 patients were recruited (66 MI vs 61 NO-CAD) and 3602 conjunctival vessels analysed (2414 MI vs 1188 NO-CAD). Mean Va, Vcs and Q were significantly lower in the MI vs NO-CAD cohort (Va 0.50 ± 0.17 mm/s vs 0.55 ± 0.15 mm/s, p < 0.001; Vcs 0.35 ± 0.12 mm/s vs 0.38 ± 0.10 mm/s, p < 0.001; Q 154 ± 116 pl/s vs 198 ± 130 pl/s, p < 0.001). To correct for differences in mean vessel diameter, WSR was compared in 10-36 µm vessels (3268/3602 vessels) and was lower in the MI-cohort (134 ± 64 s-1 vs 140 ± 63 s-1, p = 0.002). CONCLUSIONS: Conjunctival microcirculatory alterations can be observed in patients with obstructive coronary artery disease. The conjunctival microvasculature merits further evaluation in cardiovascular risk screening.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Microcirculación/fisiología , Estudios Transversales , Conjuntiva/irrigación sanguínea , Vasos Coronarios/diagnóstico por imagen , Angiografía Coronaria
9.
Catheter Cardiovasc Interv ; 101(3): 553-562, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36709485

RESUMEN

BACKGROUND: Techniques for provisional and dual-stent left main bifurcation stenting require optimization. AIM: To identify technical variables influencing procedural outcomes and periprocedural myocardial infarction following left main bifurcation intervention. METHODS: Procedural and outcome data were analyzed in 438 patients from the per-protocol cohort of the European Bifurcation Club Left Main Trial (EBC MAIN). These patients were randomized to the provisional strategy or a compatible dual-stent extension (T, T-and-protrude, or culotte). RESULTS: Mean age was 71 years and 37.4% presented with an acute coronary syndrome. Transient reduction of side vessel thrombolysis in myocardial infarction flow occurred after initial stent placement in 5% of procedures but was not associated with periprocedural myocardial infarction. Failure to rewire a jailed vessel during any strategy was more common when jailed wires were not used (9.5% vs. 2.5%, odds ratio [OR]: 6.4, p = 0.002). In the provisional cohort, the use of the proximal optimization technique was associated with less subsequent side vessel intervention (23.3% vs. 41.9%, OR: 0.4, p = 0.048). Side vessel stenting was predominantly required for dissection, which occurred more often following side vessel preparation (15.3% vs. 4.4%, OR: 3.1, p = 0.040). Exclusive use of noncompliant balloons for kissing balloon inflation was associated with reduced need for side vessel intervention in provisional cases (20.5% vs. 38.5%, OR: 0.4, p = 0.013), and a reduced risk of periprocedural myocardial infarction across all strategies (2.9% vs. 7.7%, OR: 0.2, p = 0.020). CONCLUSION: When performing provisional or compatible dual-stent left main bifurcation intervention, jailed wire use is associated with successful jailed vessel rewiring. Side vessel preparation in provisional patients is linked to increased side vessel dissection requiring stenting. Use of the proximal optimization technique may reduce the need for additional side vessel intervention, and noncompliant balloon use for kissing balloon inflation is associated with a reduction in both side vessel stenting and periprocedural myocardial infarction. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT02497014.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Humanos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Resultado del Tratamiento , Stents , Infarto del Miocardio/etiología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Angiografía Coronaria
10.
J Cardiothorac Surg ; 17(1): 126, 2022 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-35606861

RESUMEN

BACKGROUND: Concomitant double valve pathology in the presence of severe MAC poses significant technical challenges when planning surgical intervention. With continued evolution of valve prosthesis, innovative techniques can be considered with the potential for additional therapeutic benefit. CASE PRESENTATION: We present a novel technique of using a rapid deployment surgical aortic valve in combination with open surgical transcatheter mitral valve implantation (TMVI) for severe Mitral Annular Calcification (MAC). The Intuity Elite rapid deployment prosthesis (Edwards Lifesciences, Irvine, CA) was used concomitantly with the Sapien 3 (Edwards Lifesciences, Irvine, CA) transcatheter prosthesis trans-atrially on cardiopulmonary bypass in a patient with critical aortic stenosis and moderate-severe mixed mitral valve disease in the setting of severe MAC (off-label use). CONCLUSIONS: We demonstrate how both technologies can, not only be accommodated, but indeed complement each other achieving an excellent outcome in a high-risk patient.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/cirugía , Diseño de Prótesis , Resultado del Tratamiento
11.
Sci Rep ; 12(1): 6545, 2022 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-35449196

RESUMEN

Microvascular haemodynamic alterations are associated with coronary artery disease (CAD). The conjunctival microcirculation can easily be assessed non-invasively. However, the microcirculation of the conjunctiva has not been previously explored in clinical algorithms aimed at identifying patients with CAD. This case-control study involved 66 patients with post-myocardial infarction and 66 gender-matched healthy controls. Haemodynamic properties of the conjunctival microcirculation were assessed with a validated iPhone and slit lamp-based imaging tool. Haemodynamic properties were extracted with semi-automated software and compared between groups. Biomarkers implicated in the development of CAD were assessed in combination with conjunctival microcirculatory parameters. The conjunctival blood vessel parameters and biomarkers were used to derive an algorithm to aid in the screening of patients for CAD. Conjunctival blood velocity measured in combination with the blood biomarkers (N-terminal pro-brain natriuretic peptide and adiponectin) had an area under receiver operator characteristic curve (AUROC) of 0.967, sensitivity 93.0%, specificity 91.5% for CAD. This study demonstrated that the novel algorithm which included a combination of conjunctival blood vessel haemodynamic properties, and blood-based biomarkers could be used as a potential screening tool for CAD and should be validated for potential utility in asymptomatic individuals.


Asunto(s)
Algoritmos , Conjuntiva , Biomarcadores , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Conjuntiva/irrigación sanguínea , Humanos , Microcirculación
12.
J Invasive Cardiol ; 34(5): E380-E389, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35394450

RESUMEN

OBJECTIVES: To define the optimal implantation of the Sapien 3 (Edwards Lifesciences) transcatheter heart valve (THV), this study systematically analyzed the predeployment fluoroscopic THV position and correlated this to clinical outcomes. METHODS: This was an observational study of 279 patients treated with the Sapien 3 THV. Fluoroscopic imaging was used to categorize patients into low (n = 147), intermediate (n = 86), and high (n = 46) implantation zones. These zones were based on the relationship of the balloon marker and radiolucent line of the valve frame (line of lucency) to the annular plane at deployment. The primary outcome was the rate of permanent pacemaker implantation (PPI) at 30 days. The secondary outcomes were the rates of new left bundle-branch block (LBBB) in-hospital and all-cause mortality at 1 year. RESULTS: In the high, intermediate, and low groups, 30-day PPI rates were 4.3%, 8.1%, and 8.8% (P=.62); in-hospital LBBB rates were 10.9%, 26.7%, and 32.0% (P=.02); and all-cause mortality rates at 1 year were 3.1%, 7.3%, and 12.5% (P=.14), respectively. No differences were observed with respect to procedural success/complications or THV performance between the groups. CONCLUSION: This study demonstrates fewer conduction abnormalities for Sapien 3 valves positioned within a higher zone defined fluoroscopically by the line of lucency and balloon marker.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
13.
JACC Cardiovasc Interv ; 15(6): 590-598, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-35331450

RESUMEN

OBJECTIVES: The aim of this study was to determine the safety and efficacy of same-day discharge (SDD) after transcatheter aortic valve replacement (TAVR) during the COVID-19 pandemic. BACKGROUND: The COVID-19 pandemic has placed significant stress on health care systems worldwide. SDD in highly selected TAVR patients can facilitate the provision of essential cardiovascular care while managing competing COVID-19 resource demands. METHODS: Patient selection for SDD was at the discretion of the local multidisciplinary heart team, across 7 international sites. The primary outcome was a composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new permanent pacemaker (PPM) implantation. RESULTS: From March 2020 to August 2021, 124 of 2,100 patients who underwent elective transfemoral TAVR were selected for SDD. The average age was 78.9 ± 7.8 years, the median Society of Thoracic Surgeons score was 2.4 (IQR: 1.4-4.2), and 32.3% (n = 40) had preexisting PPMs. There were no major vascular complications, strokes, or deaths during the index admission. One patient (0.8%) required PPM implantation for complete heart block and was discharged the same day. No patient required a PPM between discharge home and 30-day follow-up. The composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new PPM at 30 days occurred in 5.7% patients (n = 6 of 106). CONCLUSIONS: SDD post-TAVR is safe and feasible in selected patients at low risk for adverse clinical events postdischarge. This strategy may have a potential role in highly selected patients even when the COVID-19 pandemic abates.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Reemplazo de la Válvula Aórtica Transcatéter , Cuidados Posteriores , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Humanos , Pandemias , Alta del Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
Heart ; 108(8): 639-647, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35058295

RESUMEN

OBJECTIVE: To define the incidence and risk factors for infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI). METHODS: All patients who underwent first SAVR or TAVI in England between 2007 and 2016 were identified from the NICOR databases. Hospital admissions with a primary diagnosis of IE were identified by linkage with the NHS Hospital Episode Statistics database. Approval was obtained from the NHS Research Ethics Committee. RESULTS: 2057 of 91 962 patients undergoing SAVR developed IE over a median follow-up of 53.9 months-an overall incidence of 4.81 [95% CI 4.61 to 5.03] per 1000 person-years. Correspondingly, 140 of 14 195 patients undergoing TAVI developed IE over a median follow-up of 24.5 months-an overall incidence of 3.57 [95% CI 3.00 to 4.21] per 1000 person-years. The cumulative incidence of IE at 60 months was higher after SAVR than after TAVI (2.4% [95% CI 2.3 to 2.5] vs 1.5% [95% CI 1.3 to 1.8], HR 1.60, p<0.001). Across the entire cohort, SAVR remained an independent predictor of IE after multivariable adjustment. Risk factors for IE included younger age, male sex, atrial fibrillation, and dialysis. CONCLUSIONS: IE is a rare complication of SAVR and TAVI. In our population, the incidence of IE was higher after SAVR than after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Curr Cardiol Rev ; 18(1): e170621194128, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34139985

RESUMEN

The 'gold standard' in the management of left main coronary artery disease has historically been coronary artery bypass surgery. Recent innovations in drug-eluting stent technology coupled with the increasing utility of physiology and imaging guidance for procedures have led to an evolving role of percutaneous coronary intervention in left main disease of low and intermediate anatomical complexity. This revascularization modality carries the clear advantage of being less invasive and significantly reduced recovery times. This practice is currently supported by international guidelines, however, it remains a controversial topic in the field of interventional cardiology, and the long-term outcomes of a percutaneous strategy have been questioned. This review describes the current evidence base for the assessment and choice of intervention in left main coronary artery disease. The percutaneous revascularization techniques and use of imaging to optimize procedures and improve clinical outcomes have been discussed.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento
16.
J Soc Cardiovasc Angiogr Interv ; 1(4): 100338, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-39131931

RESUMEN

Background: While female sex has been associated with worse outcomes following coronary revascularization, previous analyses in left main coronary artery (LMCA) disease have been conflicting. In addition, a signal that increased mortality may be specific to women treated with percutaneous coronary intervention (PCI) requires further investigation. Methods: Nordic-Baltic-British left main revascularization study (NOBLE) was a randomized trial comparing PCI to coronary artery bypass surgery (CABG) in patients with LMCA disease. The primary endpoint was a composite of all-cause mortality, nonprocedural myocardial infarction, repeat revascularization, and stroke (major adverse cardiovascular and cerebrovascular events [MACCE]). We report the 5-year sex-specific outcomes. Results: Of 1184 patients analyzed, 256 (22%) were female and 928 (78%) were male. There were no significant within-sex differences in baseline characteristics, disease location, or complexity between those treated with PCI and those with CABG. The 5-year MACCE rates were 29% and 15% in females and 28% and 20% in males treated with PCI and CABG, respectively. Within both sexes, there was an increased risk of MACCE with PCI compared with CABG, but no difference in all-cause mortality. On multivariate analysis, female sex was not an independent predictor of MACCE. Conclusions: Following the treatment of LMCA disease, long-term outcomes favored CABG over PCI in both sexes. Importantly, there was no difference in all-cause mortality in females or males at 5 â€‹years.

17.
Eur Heart J Case Rep ; 5(10): ytab387, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34738062

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has proven efficacy in the treatment of aortic stenosis (AS). Understandably, there is increasing enthusiasm for its use to treat aortic regurgitation (AR). However, there are significant anatomical differences between AS and AR which make TAVI for AR more complex. CASE SUMMARY: We present the case of technically challenging TAVI for severe AR, which was complicated by a traumatic ventricular septal defect (VSD) that required percutaneous closure. To our knowledge, this is the first published case of VSD post-TAVI for AR. DISCUSSION: This unanticipated complication highlights anatomical differences between TAVI use in AS and AR. Lack of aortic valve calcification and excessive annular compliance made stable deployment of a self-expanding valve extremely challenging. Despite device oversizing, repeated embolization of the prosthesis into the left ventricular outflow tract traumatized the interventricular septum.

18.
J Invasive Cardiol ; 33(10): E784-E790, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34609325

RESUMEN

BACKGROUND: Outcomes from the new Synergy Megatron drug-eluting stent (DES) platform (Boston Scientific) are not yet reported. This study sought to evaluate periprocedural outcomes in patients undergoing percutaneous coronary intervention (PCI) using this technology. METHODS: This was a retrospective study across two United Kingdom centers of 139 patients undergoing PCI of 146 coronary lesions using the Synergy Megatron DES. The primary endpoint was the rate of cardiovascular death. The secondary endpoint was the rate of a composite of non-fatal myocardial infarction, target-vessel revascularization, in-stent restenosis, and probable/definite stent thrombosis. Available intravascular ultrasound (IVUS) imaging was reviewed post hoc and evaluated according to predefined IVUS optimization criteria. RESULTS: Mean follow-up duration was 137.3 ± 38.3 days. The primary endpoint occurred in 0.7% of patients and the secondary endpoint occurred in 0.0% of patients. There were no cases of longitudinal stent deformation (LSD); in patients undergoing an IVUS-guided procedure, our criteria for successful IVUS optimization was achieved in 74.1% of left main stem (LMS) and 83.3% of right coronary artery (RCA) lesions. Mean minimal stent area (MSA) was 14.5 ± 3.4 mm² in the LMS, 10.0 ± 2.5 mm² in the left anterior descending coronary artery, 9.8 ± 3.0 mm² in the left circumflex, and 12.2 ± 4.0 mm² in the RCA. CONCLUSION: This study demonstrated very low rates of short-term major adverse cardiovascular events with no cases of LSD or acute/subacute stent thrombosis. It highlights the overexpansion capabilities of the Synergy Megatron DES platform. The technology safely and effectively facilitates IVUS-optimized stent parameters for the treatment of large proximal vessels and bifurcations.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Everolimus/farmacología , Humanos , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Ultrasonografía Intervencional
19.
Clin Cardiol ; 44(10): 1344-1353, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34499383

RESUMEN

BACKGROUND: The use of transcatheter aortic valve implantation (TAVI) for treating aortic stenosis (AS) has increased exponentially in recent years. Despite the availability of clinical practice guidelines for the management of valvular heart disease, disparities in quality of care (QoC) for TAVI patients remain widespread across Europe. Tailored QoC measures will help to reduce resource utilization and improve patient outcomes without compromising patient safety. Using a clear set of QoC measures, the BENCHMARK registry aims to document the progress that can be achieved if such tailored QoC measures are implemented. METHODS: The BENCHMARK registry (BENCHMARK) is a non-interventional, multicenter registry in patients with severe symptomatic AS undergoing TAVI with a 1- and 12-months follow-up. BENCHMARK will be conducted at 30 centers across Europe and will enroll a total of 2400 consecutive TAVI patients. Patients suffering from severe symptomatic AS who undergo TAVI with a balloon-expandable transcatheter aortic valve will be included. The registry will comprise four phases: (1) a retrospective baseline evaluation phase; (2) an education phase; (3) an implementation phase; and (4) a prospective effect documentation phase (prospective phase). The registry's primary objectives are to reduce the length of hospital stay and accelerate the post-procedural patient recovery pathway, but without compromising safety. The study started in April 2021 and has an estimated completion date of May 2023. DISCUSSION: BENCHMARK will establish QoC measures to reduce resource utilization, intensive care unit bed occupancy, and overall length of hospitalization with uncompromised patient safety post-TAVI (ClinicalTrials.gov Identifier: NCT04579445).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Benchmarking , Europa (Continente) , Humanos , Estudios Prospectivos , Sistema de Registros , Estudios Retrospectivos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
20.
Am Heart J ; 242: 24-32, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34450050

RESUMEN

BACKGROUND: Obesity is a real public health problem and is of growing concern. People are resorting to surgical or endoscopic means to fight against overweight and obesity. In recent years, there has been a marked increase in the use of these means and in particular the insertion of a gastric balloon which seems to present less risk than surgical methods. Renal complications from intragastric balloon placement are extremely rare. We report here the case of compression of the left renal vein revealed by lumbar pain and hematuria in an overweight 39-year-old woman who benefited from the balloon gastric placement one month before symptoms. The scanner made the diagnosis and showed a good evolution after the withdrawal of the balloon. METHODS: This was a prespecified and retrospective analysis of all consecutive patients who underwent FFR assessment for intermediate coronary lesions between January 2014 and December 2015. The primary endpoint was defined as the 1-year composite of cardiac death, vessel-related myocardial infarction, and clinically-driven target vessel revascularization. RESULTS: In 1554 lesions (23% in women), FFR was lower in men [0.83 ±0.09 vs 0.85 ±0.08, P = .004] driven by LAD values (for LAD P < .001, LCx or RCA P> .40). In proximal lesions (PLs), FFR was lower in men [0.83 ±0.10 vs 0.85 ±0.08, P = .004] with comparable values in non-PLs [0.84 ±0.09 vs 0.85 ±0.08, P = .36]. In PLs, the primary endpoint was higher in women [HR(adjusted) 3.18 (1.08-9.37), P = .035] with comparable outcomes in non-PLs (P = .032 for interaction). In deferred lesions, the primary endpoint was higher in women [HR(adjusted) 2.73 (1.10-6.74), P = .03] with no differences in revascularized lesions across sex (P = .02 for interaction). Results were consistent when using propensity score matching analysis. CONCLUSIONS: There is a sex-based difference in FFR, particularly in stenoses subtending large myocardium, and more evident in deferred lesions.


Asunto(s)
Reserva del Flujo Fraccional Miocárdico , Balón Gástrico , Sobrepeso , Adulto , Femenino , Balón Gástrico/efectos adversos , Humanos , Masculino , Sobrepeso/cirugía , Estudios Retrospectivos , Factores Sexuales , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA