Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38987985

RESUMEN

PURPOSE: The transverse relaxation time T 2 $$ {}_2 $$ holds significant relevance in clinical applications and research studies. Conventional T 2 $$ {}_2 $$ mapping approaches rely on spin-echo sequences, which require lengthy acquisition times and involve high radiofrequency (RF) power deposition. An alternative gradient echo (GRE) phase-based T 2 $$ {}_2 $$ mapping method, utilizing steady-state acquisitions at one small RF spoil phase increment, was recently demonstrated. Here, a modified magnitude- and phase-based T 2 $$ {}_2 $$ mapping approach is proposed, which improves T 2 $$ {\mathrm{T}}_2 $$ estimations by simultaneous fitting of T 1 $$ {\mathrm{T}}_1 $$ and signal amplitude ( A ∝ P D $$ A\propto PD $$ ) at three or more RF spoiling phase increments, instead of assuming a fixed T 1 $$ {\mathrm{T}}_1 $$ value. METHODS: The feasibility of the magnitude-phase-based method was assessed by simulations, in phantom and in vivo experiments using skipped-CAIPI three-dimensional-echo-planar imaging (3D-EPI) for rapid GRE imaging. T 2 $$ {\mathrm{T}}_2 $$ , T 1 $$ {\mathrm{T}}_1 $$ and PD estimations obtained by our method were compared to T 2 $$ {\mathrm{T}}_2 $$ of the phase-based method and T 1 $$ {\mathrm{T}}_1 $$ and PD of spoiled GRE-based multi-parameter mapping using a multi-echo version of the same sequence. RESULTS: The agreement of the proposed T 2 $$ {\mathrm{T}}_2 $$ with ground truth and reference T 2 $$ {\mathrm{T}}_2 $$ values was higher than that of phase-based T 2 $$ {\mathrm{T}}_2 $$ in simulations and in phantom data. While phase-based T 2 $$ {\mathrm{T}}_2 $$ overestimation increases with actual T 2 $$ {\mathrm{T}}_2 $$ and T 1 $$ {\mathrm{T}}_1 $$ , the proposed method is accurate over a large range of physiologically meaningful T 2 $$ {\mathrm{T}}_2 $$ and T 1 $$ {\mathrm{T}}_1 $$ values. At the same time, precision is improved. In vivo results were in line with these observations. CONCLUSION: Accurate magnitude-phase-based T 2 $$ {}_2 $$ mapping is feasible in less than 5 min scan time for 1 mm nominal isotropic whole-head coverage at 3T and 7T.

2.
Magn Reson Med ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38988040

RESUMEN

PURPOSE: To explore the high signal-to-noise ratio (SNR) efficiency of interleaved multishot 3D-EPI with standard image reconstruction for fast and robust high-resolution whole-brain quantitative susceptibility (QSM) and R 2 ∗ $$ {R}_2^{\ast } $$ mapping at 7 and 3T. METHODS: Single- and multi-TE segmented 3D-EPI is combined with conventional CAIPIRINHA undersampling for up to 72-fold effective gradient echo (GRE) imaging acceleration. Across multiple averages, scan parameters are varied (e.g., dual-polarity frequency-encoding) to additionally correct for B 0 $$ {\mathrm{B}}_0 $$ -induced artifacts, geometric distortions and motion retrospectively. A comparison to established GRE protocols is made. Resolutions range from 1.4 mm isotropic (1 multi-TE average in 36 s) up to 0.4 mm isotropic (2 single-TE averages in approximately 6 min) with whole-head coverage. RESULTS: Only 1-4 averages are needed for sufficient SNR with 3D-EPI, depending on resolution and field strength. Fast scanning and small voxels together with retrospective corrections result in substantially reduced image artifacts, which improves susceptibility and R 2 ∗ $$ {R}_2^{\ast } $$ mapping. Additionally, much finer details are obtained in susceptibility-weighted image projections through significantly reduced partial voluming. CONCLUSION: Using interleaved multishot 3D-EPI, single-TE and multi-TE data can readily be acquired 10 times faster than with conventional, accelerated GRE imaging. Even 0.4 mm isotropic whole-head QSM within 6 min becomes feasible at 7T. At 3T, motion-robust 0.8 mm isotropic whole-brain QSM and R 2 ∗ $$ {R}_2^{\ast } $$ mapping with no apparent distortion in less than 7 min becomes clinically feasible. Stronger gradient systems may allow for even higher effective acceleration rates through larger EPI factors while maintaining optimal contrast.

3.
Commun Biol ; 7(1): 271, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38443439

RESUMEN

Physical exercise studies are generally underrepresented in young adulthood. Seventeen subjects were randomized into an intervention group (24.2 ± 3.9 years; 3 trainings/week) and 10 subjects into a passive control group (23.7 ± 4.2 years), over a duration of 6 months. Every two months, performance diagnostics, computerized spatial memory tests, and 3 Tesla magnetic resonance imaging were conducted. Here we find that the intervention group, compared to controls, showed increased cardiorespiratory fitness, spatial memory performance and subregional hippocampal volumes over time. Time-by-condition interactions occurred in right cornu ammonis 4 body and (trend only) dentate gyrus, left hippocampal tail and left subiculum. Increases in spatial memory performance correlated with hippocampal body volume changes and, subregionally, with left subicular volume changes. In conclusion, findings support earlier reports of exercise-induced subregional hippocampal volume changes. Such exercise-related plasticity may not only be of interest for young adults with clinical disorders of hippocampal function, but also for sedentary normal cohorts.


Asunto(s)
Composición Corporal , Memoria Espacial , Adulto Joven , Humanos , Adulto , Cognición , Ejercicio Físico , Hipocampo/diagnóstico por imagen
4.
MAGMA ; 37(2): 169-183, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38197908

RESUMEN

OBJECTIVE: To assess the possible influence of third-order shim coils on the behavior of the gradient field and in gradient-magnet interactions at 7 T and above. MATERIALS AND METHODS: Gradient impulse response function measurements were performed at 5 sites spanning field strengths from 7 to 11.7 T, all of them sharing the same exact whole-body gradient coil design. Mechanical fixation and boundary conditions of the gradient coil were altered in several ways at one site to study the impact of mechanical coupling with the magnet on the field perturbations. Vibrations, power deposition in the He bath, and field dynamics were characterized at 11.7 T with the third-order shim coils connected and disconnected inside the Faraday cage. RESULTS: For the same whole-body gradient coil design, all measurements differed greatly based on the third-order shim coil configuration (connected or not). Vibrations and gradient transfer function peaks could be affected by a factor of 2 or more, depending on the resonances. Disconnecting the third-order shim coils at 11.7 T also suppressed almost completely power deposition peaks at some frequencies. DISCUSSION: Third-order shim coil configurations can have major impact in gradient-magnet interactions with consequences on potential hardware damage, magnet heating, and image quality going beyond EPI acquisitions.


Asunto(s)
Imagen por Resonancia Magnética , Imanes , Imagen por Resonancia Magnética/métodos
5.
MAGMA ; 36(2): 191-210, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37029886

RESUMEN

Multiple sites within Germany operate human MRI systems with magnetic fields either at 7 Tesla or 9.4 Tesla. In 2013, these sites formed a network to facilitate and harmonize the research being conducted at the different sites and make this technology available to a larger community of researchers and clinicians not only within Germany, but also worldwide. The German Ultrahigh Field Imaging (GUFI) network has defined a strategic goal to establish a 14 Tesla whole-body human MRI system as a national research resource in Germany as the next progression in magnetic field strength. This paper summarizes the history of this initiative, the current status, the motivation for pursuing MR imaging and spectroscopy at such a high magnetic field strength, and the technical and funding challenges involved. It focuses on the scientific and science policy process from the perspective in Germany, and is not intended to be a comprehensive systematic review of the benefits and technical challenges of higher field strengths.


Asunto(s)
Imagen por Resonancia Magnética , Imagen de Cuerpo Entero , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Imagen de Cuerpo Entero/métodos , Alemania , Campos Magnéticos
6.
Brain Sci ; 13(3)2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-36979198

RESUMEN

BACKGROUND: Attention-deficit-hyperactivity disorder (ADHD) is a neurodevelopmental disorder neurobiologically conceptualized as a network disorder in white and gray matter. A relatively new branch in ADHD research is sensory processing. Here, altered sensory processing i.e., sensory hypersensitivity, is reported, especially in the auditory domain. However, our perception is driven by a complex interplay across different sensory modalities. Our brain is specialized in binding those different sensory modalities to a unified percept-a process called multisensory integration (MI) that is mediated through fronto-temporal and fronto-parietal networks. MI has been recently described to be impaired for complex stimuli in adult patients with ADHD. The current study relates MI in adult ADHD with diffusion-weighted imaging. Connectome-based and graph-theoretic analysis was applied to investigate a possible relationship between the ability to integrate multimodal input and network-based ADHD pathophysiology. METHODS: Multishell, high-angular resolution diffusion-weighted imaging was performed on twenty-five patients with ADHD (six females, age: 30.08 (SD: 9.3) years) and twenty-four healthy controls (nine females; age: 26.88 (SD: 6.3) years). Structural connectome was created and graph theory was applied to investigate ADHD pathophysiology. Additionally, MI scores, i.e., the percentage of successful multisensory integration derived from the McGurk paradigm, were groupwise correlated with the structural connectome. RESULTS: Structural connectivity was elevated in patients with ADHD in network hubs mirroring altered default-mode network activity typically reported for patients with ADHD. Compared to controls, MI was associated with higher connectivity in ADHD between Heschl's gyrus and auditory parabelt regions along with altered fronto-temporal network integrity. CONCLUSION: Alterations in structural network integrity in adult ADHD can be extended to multisensory behavior. MI and the respective network integration in ADHD might represent the maturational cortical delay that extends to adulthood with respect to sensory processing.

7.
Healthcare (Basel) ; 11(5)2023 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-36900693

RESUMEN

Physical activity (PA) plays an important role in affect processing. Studies describe the orbitofrontal cortex (OFC) as a major hub for emotion processing and the pathophysiology of affective disorders. Subregions of the OFC show diverse functional connectivity (FC) topographies, but the effect of chronic PA on subregional OFC FC still lacks scientific understanding. Therefore, we aimed at investigating the effects of regular PA on the FC topographies of OFC subregions in healthy individuals within a longitudinal randomized controlled exercise study. Participants (age: 18-35 years) were randomly assigned to either an intervention group (IG; N = 18) or a control group (CG; N = 10). Fitness assessments, mood questionnaires, and resting state functional magnetic resonance imaging (rsfMRI) were performed four times over the duration of 6 months. Using a detailed parcellation of the OFC, we created subregional FC topography maps at each time point and applied a linear mixed model to assess the effects of regular PA. The posterior-lateral right OFC showed a group and time interaction, revealing decreased FC with the left dorsolateral prefrontal cortex in the IG, while FC in the CG increased. Group and time interaction in the anterior-lateral right OFC with the right middle frontal gyrus was driven by increased FC in the IG. The posterior-lateral left OFC showed a group and time interaction based on differential change in FC to the left postcentral gyrus and the right occipital gyrus. This study emphasized regionally distinctive FC changes induced by PA within the lateral OFC territory, while providing aspects for further research.

8.
Front Aging Neurosci ; 14: 951022, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36034125

RESUMEN

Physical inactivity is documented as a health risk factor for chronic diseases, accelerated aging, and cognitive impairment. Physical exercise, on the other hand, plays an important role in healthy aging by promoting positive muscular, cardiovascular, and central nervous system adaptions. Prior studies on the effects of exercise training on cerebral perfusion have focused largely on elderly cohorts or patient cohorts, while perfusion effects of exercise training in young sedentary adults have not yet been fully assessed. Therefore, the present study examined the physiological consequence of a 6-month endurance exercise training on brain perfusion in 28 young sedentary adults randomly assigned to an intervention group (IG; regular physical exercise) or a control group (CG; without physical exercise). The IG performed an extensive running interval training three times per week over 6 months. Performance diagnostics and MRI were performed every 2 months, and training intensity was adapted individually. Brain perfusion measurements with pseudo-continuous arterial spin labeling were analyzed using the standard Oxford ASL pipeline. A significant interaction effect between group and time was found for right superior temporal gyrus (STG) perfusion, driven by an increase in the IG and a decrease in the CG. Furthermore, a significant time effect was observed in the right middle occipital region in the IG only. Perfusion increases in the right STG, in the ventral striatum, and in primary motor areas were significantly associated with increases in maximum oxygen uptake (VO2max). Overall, this study identified region-specific increases in local perfusion in a cohort of young adults that partly correlated with individual performance increases, hence, suggesting exercise dose dependency. Respective adaptations in brain perfusion are discussed in the context of physical exercise-induced vascular plasticity.

9.
Magn Reson Med ; 88(6): 2564-2572, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35942989

RESUMEN

PURPOSE: We present a time-efficient water-selective, parallel transmit RF excitation pulse design for ultra-high field applications. METHODS: The proposed pulse design method achieves flip angle homogenization at ultra-high fields by employing spatially nonselective k T $$ {\mathrm{k}}_T $$ -points pulses. In order to introduce water-selection, the concept of binomial pulses is applied. Due to the composite nature of k T $$ {\mathrm{k}}_T $$ -points, the pulse can be split into multiple binomial subpulse blocks shorter than half the precession period of fat, that are played out successively. Additional fat precession turns, that would otherwise impair the spectral response, can thus be avoided. Bloch simulations of the proposed interleaved binomial k T $$ {\mathrm{k}}_T $$ -points pulses were carried out and compared in terms of duration, homogeneity, fat suppression and pulse energy. For validation, in vivo MP-RAGE and 3D-EPI data were acquired. RESULTS: Simulation results show that interleaved binomial k T $$ {\mathrm{k}}_T $$ -points pulses achieve shorter total pulse durations, improved flip angle homogeneity and more robust fat suppression compared to available methods. Interleaved binomial k T $$ {\mathrm{k}}_T $$ -points can be customized by changing the number of k T $$ {\mathrm{k}}_T $$ -points, the subpulse duration and the order of the binomial pulse. Using shorter subpulses, the number of k T $$ {\mathrm{k}}_T $$ -points can be increased and hence better homogeneity is achieved, while still maintaining short total pulse durations. Flip angle homogenization and fat suppression of interleaved binomial k T $$ {\mathrm{k}}_T $$ -points pulses is demonstrated in vivo at 7T, confirming Bloch simulation results. CONCLUSION: In this work, we present a time efficient and robust parallel transmission technique for nonselective water excitation with simultaneous flip angle homogenization at ultra-high field.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Agua , Algoritmos , Encéfalo , Simulación por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
10.
Magn Reson Med ; 88(6): 2395-2407, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35968675

RESUMEN

PURPOSE: This work presents an end-to-end open-source MR imaging workflow. It is highly flexible in rapid prototyping across the whole imaging process and integrates vendor-independent openly available tools. The whole workflow can be shared and executed on different MR platforms. It is also integrated in the JEMRIS simulation framework, which makes it possible to generate simulated data from the same sequence that runs on the MRI scanner using the same pipeline for image reconstruction. METHODS: MRI sequences can be designed in Python or JEMRIS using the Pulseq framework, allowing simplified integration of new sequence design tools. During the sequence design process, acquisition metadata required for reconstruction is stored in the MR raw data format. Data acquisition is possible on MRI scanners supported by Pulseq and in simulations through JEMRIS. An image reconstruction and postprocessing pipeline was implemented into a Python server that allows real-time processing of data as it is being acquired. The Berkeley Advanced Reconstruction Toolbox is integrated into this framework for image reconstruction. The reconstruction pipeline supports online integration through a vendor-dependent interface. RESULTS: The flexibility of the workflow is demonstrated with different examples, containing 3D parallel imaging with controlled aliasing in volumetric parallel imaging (CAIPIRINHA) acceleration, spiral imaging, and B0 mapping. All sequences, data, and the corresponding processing pipelines are publicly available. CONCLUSION: The proposed workflow is highly flexible and allows integration of advanced tools at all stages of the imaging process. All parts of this workflow are open-source, simplifying collaboration across different MR platforms or sites and improving reproducibility of results.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Flujo de Trabajo
11.
Magn Reson Med ; 88(5): 2217-2232, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35877781

RESUMEN

PURPOSE: Quantitative multi-parameter mapping (MPM) has been shown to provide good longitudinal and cross-sectional reproducibility for clinical research. Unfortunately, acquisition times (TAs) are typically infeasible for routine scanning at high resolutions. METHODS: A fast whole-brain MPM protocol based on interleaved multi-shot 3D-EPI with controlled aliasing (SC-EPI) at 3T and 7T is proposed and compared with MPM using a standard spoiled gradient echo (FLASH) sequence. Four parameters (R1 , PD, R 2 * $$ {R}_2^{\ast } $$ , and MTsat) were measured in less than 3 min at 1 mm isotropic resolution. Five subjects went through the same scanning sessions twice at each scanner. The intra-subject coefficient of variation (scan-rescan) (CoV) was estimated for each protocol and scanner to assess the longitudinal reproducibility. RESULTS: At 3T, the CoV of SC-EPI ranged between 1.2%-4.8% for PD and R1 , 2.8%-10.6% for R 2 * $$ {R}_2^{\ast } $$ and MTsat, which was comparable with FLASH (0.6%-4.9% for PD and R1 , 2.6%-11.3% for R 2 * $$ {R}_2^{\ast } $$ and MTsat). At 7T, where the SC-EPI TA was reduced to ∼2 min, the CoV of SC-EPI (1.4%-10.6% for PD, R1 , and R 2 * $$ {R}_2^{\ast } $$ ) was 1.2-2.4 times larger than the CoV of FLASH (1.0%-15%) and MTsat showed much higher variability across subjects. The SC-EPI-MPM protocol at 3T showed high reproducibility and yielded stable quantitative maps at a clinically feasible resolution and scan time, whereas at 7T, MT saturation homogeneity needs to be improved. CONCLUSION: SC-EPI-based MPM is feasible as an additional MRI modality in clinical or population studies where the parameters offer great potential as biomarkers.


Asunto(s)
Mapeo Encefálico , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Mapeo Encefálico/métodos , Estudios Transversales , Humanos , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados
12.
Neurology ; 99(9): e935-e943, 2022 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-35768207

RESUMEN

BACKGROUND AND OBJECTIVES: Mounting evidence implies that there are sex differences in white matter hyperintensity (WMH) burden in older people. Questions remain regarding possible differences in WMH burden between men and women of younger age, sex-specific age trajectories and effects of (un)controlled hypertension, and the effect of menopause on WMH. Therefore, our aim was to investigate these sex differences and age dependencies in WMH load across the adult life span and to examine the effect of menopause. METHODS: This cross-sectional analysis was based on participants of the population-based Rhineland Study (30-95 years) who underwent brain MRI. We automatically quantified WMH using T1-weighted, T2-weighted, and fluid-attenuated inversion recovery images. Menopausal status was self-reported. We examined associations of sex and menopause with WMH load (logit-transformed and z-standardized) using linear regression models while adjusting for age, age-squared, and vascular risk factors. We checked for an age × sex and (un)controlled hypertension × sex interaction and stratified for menopausal status comparing men with premenopausal women (persons aged 59 years or younger), men with postmenopausal women (persons aged 45 years or older), and premenopausal with postmenopausal women (age range 45-59 years). RESULTS: Of 3,410 participants with a mean age of 54.3 years (SD = 13.7), 1,973 (57.9%) were women, of which 1,167 (59.1%) were postmenopausal. We found that the increase in WMH load accelerates with age and in a sex-dependent way. Premenopausal women and men of similar age did not differ in WMH burden. WMH burden was higher and accelerated faster in postmenopausal women compared with men of similar age. In addition, we observed changes related to menopause, in that postmenopausal women had more WMH than premenopausal women of similar age. Women with uncontrolled hypertension had a higher WMH burden compared with men, which was unrelated to menopausal status. DISCUSSION: After menopause, women displayed a higher burden of WMH than contemporary premenopausal women and men and an accelerated increase in WMH. Sex-specific effects of uncontrolled hypertension on WMH were not related to menopause. Further studies are warranted to investigate menopause-related physiologic changes that may inform on causal mechanisms involved in cerebral small vessel disease progression.


Asunto(s)
Enfermedades de los Pequeños Vasos Cerebrales , Hipertensión , Leucoaraiosis , Sustancia Blanca , Adulto , Anciano , Estudios Transversales , Femenino , Humanos , Hipertensión/epidemiología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Premenopausia , Sustancia Blanca/diagnóstico por imagen
13.
Artículo en Inglés | MEDLINE | ID: mdl-35627616

RESUMEN

Acute exercise has beneficial effects on mood and is known to induce modulations in functional connectivity (FC) within the emotional network. However, the long-term effects of exercise on affective brain circuits remain largely unknown. Here, we investigated the effects of 6 months of regular exercise on mood, amygdala structure, and functional connectivity. This study comprised N = 18 healthy sedentary subjects assigned to an intervention group (IG; 23.9 ± 3.9 years; 3 trainings/week) and N = 10 subjects assigned to a passive control group (CG; 23.7 ± 4.2 years). At baseline and every two months, performance diagnostics, mood questionnaires, and structural and resting-state-fMRI were conducted. Amygdala-nuclei segmentation and amygdala-to-whole-brain FC analysis were performed. Linear mixed effects models and correlation analyses were conducted between FC, relVO2max, and mood scores. Data showed increases in relVO2max exclusively in the IG. Stronger anticorrelation in amygdala-precuneus FC was found, along with a stronger positive correlation in the amygdala-temporal pole FC in the IG after 4 and 6 months, while mood and amygdala volume did not reveal significant interactions. The relVO2max/amygdala-temporal pole FC correlated positively, and the amygdala-precuneus/amygdala-temporal pole FC correlated negatively. Findings suggest that exercise induced long-term modulations of the amygdala FC with the precuneus and temporal pole, shedding light on potential mechanisms by which exercise has positive influences on mood-related networks, typically altered in affective disorders.


Asunto(s)
Amígdala del Cerebelo , Mapeo Encefálico , Afecto , Amígdala del Cerebelo/diagnóstico por imagen , Ejercicio Físico , Terapia por Ejercicio , Humanos
14.
Front Neurol ; 13: 795573, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35392639

RESUMEN

Excluding persons from magnetic resonance imaging (MRI) research studies based on their medical history or because they have tattoos, can create bias and compromise the validity and generalizability of study results. In the population-based Rhineland Study, we limited exclusion criteria for MRI and allowed participants with passive medical implants, tattoos or permanent make-up to undergo MRI. Thereby, we could include 16.6% more people than would have been possible based on common recommendations. We observed no adverse events or artifacts. This supports that most passive medical implants, tattoos and permanent make-up are MRI suitable and can be scanned in research settings.

15.
Sci Rep ; 12(1): 2757, 2022 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-35177781

RESUMEN

Retinal assessments have been discussed as biomarkers for brain atrophy. However, available studies did not investigate all retinal layers due to older technology, reported inconsistent results, or were based on small sample sizes. We included 2872 eligible participants of the Rhineland Study with data on spectral domain-optical coherence tomography (SD-OCT) and brain magnetic resonance imaging (MRI). We used multiple linear regression to examine relationships between retinal measurements and volumetric brain measures as well as fractional anisotropy (FA) as measure of microstructural integrity of white matter (WM) for different brain regions. Mean (SD) age was 53.8 ± 13.2 years (range 30-94) and 57% were women. Volumes of the inner retina were associated with total brain and grey matter (GM) volume, and even stronger with WM volume and FA. In contrast, the outer retina was mainly associated with GM volume, while both, inner and outer retina, were associated with hippocampus volume. While we extend previously reported associations between the inner retina and brain measures, we found additional associations of the outer retina with parts of the brain. This indicates that easily accessible retinal SD-OCT assessments may serve as biomarkers for clinical monitoring of neurodegenerative diseases and merit further research.


Asunto(s)
Encefalopatías/diagnóstico por imagen , Sustancia Gris/diagnóstico por imagen , Imagen por Resonancia Magnética , Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica , Sustancia Blanca/diagnóstico por imagen , Adulto , Atrofia , Femenino , Humanos , Masculino , Persona de Mediana Edad
17.
Neuroradiology ; 64(3): 503-512, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34842946

RESUMEN

PURPOSE: Development of best practices for dealing with incidental findings on neuroimaging requires insight in their frequency and clinical relevance. METHODS: Here, we delineate prevalence estimates with 95% confidence intervals and clinical management of incidental findings, based on the first 3589 participants of the population-based Rhineland Study (age range 30-95 years) who underwent 3 Tesla structural neuroimaging (3D, 0.8 mm3 isotropic resolution). Two trained raters independently assessed all scans for abnormalities, with confirmation and adjudication where needed by neuroradiologists. Participants were referred for diagnostic work-up depending on the potential benefit. RESULTS: Of 3589 participants (mean age 55 ± 14 years, 2072 women), 867 had at least one possible incidental finding (24.2%). Most common were pituitary abnormalities (12.3%), arachnoid cysts (4.1%), developmental venous anomalies (2.5%), non-acute infarcts (1.8%), cavernomas (1.0%), and meningiomas (0.7%). Forty-six participants were informed about their findings, which was hitherto unknown in 40 of them (1.1%). Of these, in 19 participants (48%), a wait-and-see policy was applied and nine (23%) received treatment, while lesions in the remainder were benign, could not be confirmed, or the participant refused to inform us about their clinical diagnosis. CONCLUSION: Nearly one-quarter of participants had an incidental finding, but only 5% of those required referral, that mostly remained without direct clinical consequences.


Asunto(s)
Hallazgos Incidentales , Neoplasias Meníngeas , Adulto , Anciano , Anciano de 80 o más Años , Encéfalo/patología , Estudios Transversales , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Neoplasias Meníngeas/patología , Persona de Mediana Edad , Neuroimagen/métodos
18.
Front Neurosci ; 15: 711898, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34489631

RESUMEN

The perfusion parameters cerebral blood flow (CBF) and arterial transit time (ATT) measured with arterial spin labeling (ASL) magnetic resonance imaging (MRI) provide valuable essentials to assess the integrity of cerebral tissue. Brain perfusion changes, due to aging, an intervention, or neurodegenerative diseases for example, could be investigated in longitudinal ASL studies with reliable ASL sequences. Generally, pseudo-continuous ASL (pCASL) is preferred because of its larger signal-to-noise ratio (SNR) compared to pulsed ASL (PASL) techniques. Available pCASL versions differ regarding their feature details. To date only little is known about the reliability and reproducibility of CBF and ATT measures obtained with the innovative Hadamard encoded pCASL variant, especially if applied on participants in old age. Therefore, we investigated an in-house developed Hadamard encoded pCASL sequence on a group of healthy elderly at two different 3 Tesla Siemens MRI systems (Skyra and mMR Biograph) and evaluated CBF and ATT reliability and reproducibility for several regions-of-interests (ROI). Calculated within-subject coefficients of variation (wsCV) demonstrated an excellent reliability of perfusion measures, whereas ATT appeared to be even more reliable than CBF [e.g., wsCV(CBF) = 2.9% vs. wsCV(ATT) = 2.3% for a gray matter (GM) ROI on Skyra system]. Additionally, a substantial agreement of perfusion values acquired on both MRI systems with an inter-session interval of 78 ± 17.6 days was shown by high corresponding intra-class correlation (ICC) coefficients [e.g., ICC(CBF) = 0.704 and ICC(ATT) = 0.754 for a GM ROI]. The usability of this novel Hadamard encoded pCASL sequence might improve future follow-up perfusion studies of the aging and/or diseased brain.

19.
J Psychiatry Neurosci ; 46(5): E528-E537, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34548387

RESUMEN

BACKGROUND: Studies investigating sensory processing in attention-deficit/hyperactivity disorder (ADHD) have shown altered visual and auditory processing. However, evidence is lacking for audiovisual interplay - namely, multisensory integration. As well, neuronal dysregulation at rest (e.g., aberrant within- or between-network functional connectivity) may account for difficulties with integration across the senses in ADHD. We investigated whether sensory processing was altered at the multimodal level in adult ADHD and included resting-state functional connectivity to illustrate a possible overlap between deficient network connectivity and the ability to integrate stimuli. METHODS: We tested 25 patients with ADHD and 24 healthy controls using 2 illusionary paradigms: the sound-induced flash illusion and the McGurk illusion. We applied the Mann-Whitney U test to assess statistical differences between groups. We acquired resting-state functional MRIs on a 3.0 T Siemens magnetic resonance scanner, using a highly accelerated 3-dimensional echo planar imaging sequence. RESULTS: For the sound-induced flash illusion, susceptibility and reaction time were not different between the 2 groups. For the McGurk illusion, susceptibility was significantly lower for patients with ADHD, and reaction times were significantly longer. At a neuronal level, resting-state functional connectivity in the ADHD group was more highly regulated in polymodal regions that play a role in binding unimodal sensory inputs from different modalities and enabling sensory-to-cognition integration. LIMITATIONS: We did not explicitly screen for autism spectrum disorder, which has high rates of comorbidity with ADHD and also involves impairments in multisensory integration. Although the patients were carefully screened by our outpatient department, we could not rule out the possibility of autism spectrum disorder in some participants. CONCLUSION: Unimodal hypersensitivity seems to have no influence on the integration of basal stimuli, but it might have negative consequences for the multisensory integration of complex stimuli. This finding was supported by observations of higher resting-state functional connectivity between unimodal sensory areas and polymodal multisensory integration convergence zones for complex stimuli.


Asunto(s)
Trastorno por Déficit de Atención con Hiperactividad/fisiopatología , Trastorno por Déficit de Atención con Hiperactividad/psicología , Percepción Auditiva , Descanso , Percepción Visual , Adulto , Trastorno por Déficit de Atención con Hiperactividad/complicaciones , Trastorno del Espectro Autista/complicaciones , Femenino , Humanos , Ilusiones , Imagen por Resonancia Magnética , Masculino
20.
Parkinsonism Relat Disord ; 91: 105-108, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34562715

RESUMEN

INTRODUCTION: The ventral intermediate nucleus of the thalamus (VIM) is an important relay station receiving cerebellar and pallidal fiber tracts. Data on structural visualization of the VIM however is limited and uncertainty prevails to what extent lesional approaches to treat tremor affect the VIM itself or passing tracts. The aim of the study was to analyze the localization of individual lesions with respect to the VIM and the cerebello-thalamic tract (CTT). METHODS: We employed ultrahigh resolution (7 Tesla) MRI to delineate the VIM and performed 3 T-DTI-imaging pre- and post-interventional in seven ET patients undergoing transcranial magnetic resonance guided focused ultrasound (tcMRgFUS). Tremor improvement was measured using a modified subscore of the Clinical Rating Scale for Tremor. RESULTS: All subjects showed substantial tremor improvement (88.5%, range 80.7%-94,8%) after tcMRgFUS. We found only a minor overlap of the lesions with the VIM (4%, range 1%-7%) but a larger overlap with the CTT (43%, range 23%-60%) in all subjects. CONCLUSIONS: Lesions within the CTT rather than the VIM seem to drive the tremorlytic response and clinical improvement in tcMRgFUS.


Asunto(s)
Cerebelo/diagnóstico por imagen , Temblor Esencial/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tálamo/diagnóstico por imagen , Núcleos Talámicos Ventrales/diagnóstico por imagen , Anciano , Cerebelo/patología , Temblor Esencial/patología , Temblor Esencial/terapia , Femenino , Ultrasonido Enfocado de Alta Intensidad de Ablación , Humanos , Masculino , Persona de Mediana Edad , Tálamo/patología , Resultado del Tratamiento , Núcleos Talámicos Ventrales/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA