Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Orthop Relat Res ; 473(12): 3811-9, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26194560

RESUMEN

BACKGROUND: The incidence of acetabular fractures in osteoporotic patients is increasing. Immediate total hip arthroplasty (THA) has potential advantages, but achieving acetabular component stability is challenging and, at early followup, reported revision rates for loosening are high. QUESTIONS/PURPOSES: This study measured acetabular component stability and the initial surface contact achieved between the acetabular component and unfractured region of the pelvis after THA using an oversized acetabular component and cup-cage reconstruction. METHODS: Between November 2011 and November 2013, we treated 40 acute acetabular fractures in patients older than 70 years of age. Of these, 12 (30%) underwent immediate THA using an oversized acetabular component with screws inserted only into the ilium and a cup-cage construct. Postoperatively all patients were mobilized without weightbearing restrictions. Indications for immediate THA after acetabular fractures were displaced articular comminution deemed unreducible. Eleven of the 12 were prospectively studied to evaluate the initial stability of the reconstructions using radiostereometric analysis. One of the patients died of a pulmonary embolism after surgery, and the remaining 10 (median age, 81 years; range, 72-86 years) were studied. Of these, five were analyzed at 1 year and five were analyzed at 2 years. Acetabular component migration was defined as acceptable if less than the limits for primary THA that predict later loosening (1.76 mm of proximal migration and 2.53° of sagittal rotation). The contact surface between the acetabular component and ilium in direct continuity with the sacroiliac joint, and the ischium and pubis in direct continuity with the symphysis pubis, was measured on postoperative CT scans. RESULTS: At 1 year the median proximal migration was 0.83 mm (range, 0.09-5.13 mm) and sagittal rotation was 1.3° (range, 0.1°-7.4°). Three of the 10 components had migration above the suggested limits for primary THA at 1 year postoperatively. The contact surface achieved at surgery between the acetabular component and pelvis ranged from 11 to 17 cm(2) (15%-27% of each component). CONCLUSIONS: The majority of acetabular components in this cohort were stable despite the small contact surface achieved between the component and pelvic bone. Three of 10 migrated in excess of the limits that predict later loosening in primary THA but it remains to be seen whether these limits apply to this selected group of frail osteoporotic patients. We continue to use this technique routinely to treat patients with the same indications, but since the analysis of these data we have added screw fixation of the acetabular component to the ischial tuberosity and the superior pubic ramus. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Fracturas de Cadera/cirugía , Prótesis de Cadera , Inestabilidad de la Articulación/prevención & control , Fracturas Osteoporóticas/cirugía , Falla de Prótesis , Acetábulo/diagnóstico por imagen , Acetábulo/lesiones , Acetábulo/fisiopatología , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Fenómenos Biomecánicos , Densidad Ósea , Femenino , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/fisiopatología , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/fisiopatología , Masculino , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/fisiopatología , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
J Arthroplasty ; 27(6): 1069-74, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22085797

RESUMEN

We examined the sensitivity and accuracy of measuring osteolysis around total knee arthroplasty (TKA) on radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) in a cadaver model. Fifty-four simulated osteolytic defects ranging from 0.7 to 14 cm(3) were created in 6 cadaver knees implanted with either a cemented or an uncemented TKA. Three blinded investigators assessed the presence, location, and volume of defects on radiographs and CT and MRI scans with metal reduction protocols. Both CT and MRI had significantly higher sensitivities and specificities than did plain radiographs (P < .005). Overall, there was no difference in the accuracy of defect volume measurements between CT and MRI (P = .574). This study demonstrates the limitations of radiographs and the high sensitivity and specificity of both CT and MRI in assessing osteolysis around TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Prótesis de la Rodilla/efectos adversos , Osteólisis/diagnóstico por imagen , Osteólisis/patología , Cadáver , Tomografía Computarizada Cuatridimensional , Humanos , Técnicas In Vitro , Imagen por Resonancia Magnética , Osteólisis/diagnóstico , Sensibilidad y Especificidad , Rayos X
3.
J Arthroplasty ; 26(7): 1050-6, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21802252

RESUMEN

This preclinical in vivo screening study compared bone graft incorporation and stem subsidence in cemented hemiarthroplasty after femoral impaction bone grafting with either morselized allograft bone (n = 5, control group) or a 1:1 mix of allograft and porous hydroxyapatite ceramics (HA) granules (n = 5, HA group). At 14 weeks, there was excellent bone graft incorporation by bone, and the stems were well fixed in both groups. The median subsidence at the cement-bone interface, measured using radiostereometric analysis, was 0.14 and 0.93 mm in the control and HA groups, respectively. The comparable histologic results between groups and good stem fixation in this study support the conduct of a larger scale investigation of the use of porous HA in femoral impaction bone grafting at revision hip arthroplasty.


Asunto(s)
Sustitutos de Huesos , Trasplante Óseo , Durapatita , Fémur/cirugía , Prótesis de Cadera , Oseointegración , Animales , Fémur/patología , Porosidad , Análisis Radioestereométrico , Ovinos
4.
J Arthroplasty ; 25(6): 913-9, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19775854

RESUMEN

Using computed tomography, the volume, location, and number of osteolytic lesions were determined adjacent to 38 Harris-Galante 1 (HG-1) acetabular components fixed with screws and 19 porous-coated anatomic (PCA) acetabular components press-fitted without screws. The median implantation times were 16 and 15 years, respectively. The mean total lesion volumes were similar: 11.1 cm(3) (range, 0.7-49 cm(3)) and 9.8 cm(3) (range, 0.4-52 cm(3)), respectively, for hips with HG-1 and PCA components (P = .32). There was a significant difference in the proportion of rim-related, screw or screw hole-related, and combined lesions between the 2 component designs (P < .0001). HG-1 components had more screw and screw hole-related lesions, and PCA components had more rim-related lesions. Although there are concerns regarding screw and screw hole-associated osteolysis, these findings suggest that peripheral fixation may be well maintained in the long term with the use of multiple-hole acetabular components with screw fixation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera/efectos adversos , Osteólisis/diagnóstico por imagen , Diseño de Prótesis , Acetábulo/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteólisis/etiología , Falla de Prótesis , Reoperación , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA