Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Steroids ; 178: 108953, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35026285

RESUMEN

Pharmacological glucocorticoids are the most prescribed anti-inflammatory medications, and are chemical variants of cortisol, the circadian and stress hormone. Both endogenous and pharmacological glucocorticoids bind the glucocorticoid receptor (NR3C1) with high affinity, and both then bind downstream gene promoter elements (GRE) to drive positive gene transcription of many proteins. Glucocorticoid/GR complexes also bind distinct negative gene promoter elements (nGRE) to inhibit expression of genes involved in NF-κB innate immunity signaling. We sought to define the acute response of a single dose of prednisone (0.2 mg/kg) in young adult volunteers, with blood samples taken at baseline, 2, 3, 4 and 6 h post-oral dose. To control for circadian morning cortisol hitting the same molecular pathways, a day of blood draws was done without oral prednisone (same time of day), one day prior to drug day. Serum samples were processed for steroid hormone profiles (mass spectrometry; 9 steroidal hormones), proteomics (SOMAscan aptamer panels, 1,305 proteins), and inflammatory markers (Meso Scale Discovery; 10 pro-inflammatory cytokines). The pharmacological effect of the prednisone dose was shown by significant declines of adrenal steroids by 3 h after dosing. IL-10 showed drug-related increase to 4 hrs, then decrease to 6 hrs. IL-8 showed drug-related decrease in serum by 4 h, consistent with direct negative action of GR/ligand on IL-8 gene promoter. Proteomics data showed beta-2 microglobulin, TNFSF15, TSH, CST3, NBL1 to show time-related decreases with prednisone, while CXCL13 showed increases, although these require validation. In summary, a single low dose of prednisone leads to broad suppression of the adrenal axis within 3 h, and down-regulation of inflammatory serum proteins by 6 h.


Asunto(s)
Citocinas , Receptores de Glucocorticoides , Proteínas Sanguíneas , Citocinas/genética , Glucocorticoides/uso terapéutico , Humanos , Prednisona/farmacología , Receptores de Glucocorticoides/genética , Receptores de Glucocorticoides/metabolismo , Miembro 15 de la Superfamilia de Ligandos de Factores de Necrosis Tumoral , Voluntarios , Adulto Joven
2.
Thyroid ; 31(8): 1160-1170, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34042535

RESUMEN

Background: Biotin has been reported to interfere with several commonly used laboratory assays resulting in misleading values and possible erroneous diagnosis and treatment. This report describes a prospective study of possible biotin interference in thyroid-related laboratory assays, with a comparison of different commonly used assay platforms. Materials and Methods: Thirteen adult subjects (mean age 45 ± 13 years old) were administered biotin 10 mg/day for eight days. Blood specimens were collected at three time points on day 1 and on day 8 (baseline, two, and five hours after biotin ingestion). Thyrotropin (TSH), free triiodothyronine (fT3), free thyroxine (fT4), total triiodothyronine (TT3), total thyroxine (TT4), thyroxine binding globulin (TBG), and thyroglobulin (Tg) levels were analyzed with four different platforms: Abbott Architect, Roche Cobas 6000, Siemens IMMULITE 2000, and liquid chromatography with tandem mass spectrometry (LC-MS/MS). TSH, fT3, fT4, TT3, and TT4 were measured with Abbott Architect and Roche Cobas 6000. fT3, fT4, TT3, and TT4 were also measured by LC-MS/MS. Tg was measured by Siemens IMMULITE 2000. TBG was assessed with Siemens IMMULITE 2000. Results: Significant changes in TSH, fT4, and TT3 measurements were observed after biotin exposure when the Roche Cobas 6000 platform was used. Biotin intake resulted in a falsely lower Tg level when measurements were performed with Siemens IMMULITE 2000. At the time points examined, maximal biotin interference was observed two hours after biotin exposure both on day 1 and day 8. Conclusions: A daily dose of 10 mg was shown to interfere with specific assays for TSH, fT4, TT3, and Tg. Physicians must be aware of the potential risk of erroneous test results in subjects taking biotin supplements. Altered test results for TSH and Tg can be particularly problematic in patients requiring careful titration of levothyroxine therapy such as those with thyroid cancer.


Asunto(s)
Biotina/análisis , Biotina/farmacología , Tiroglobulina/análisis , Hormonas Tiroideas/análisis , Tirotropina/análisis , Adulto , Anciano , Cromatografía Líquida de Alta Presión , Reacciones Falso Negativas , Femenino , Humanos , Masculino , Espectrometría de Masas , Persona de Mediana Edad , Estudios Prospectivos , Pruebas de Función de la Tiroides
3.
Ther Adv Endocrinol Metab ; 11: 2042018820922688, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32523672

RESUMEN

BACKGROUND: There has been a wide range of reference intervals proposed in previous literature for thyroid hormones due to large between-assay variability of immunoassays, as well as lack of correction for collection time. We provided the diurnal reference intervals for five thyroid hormones, namely total thyroxine (TT4), total triiodothyronine (TT3), free thyroxine (FT4), free triiodothyronine (FT3), and reverse T3 (rT3), measured in serum samples of healthy participants using a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method. METHODS: Couplet serum samples (a.m. and p.m.) were collected from 110 healthy females and 49 healthy males. Healthy volunteers were recruited from four participating centers between 2016 and 2018. Measurements of thyroid hormones were obtained by LC-MS/MS analysis. RESULTS: Our study revealed significant uptrend in AM to PM FT4 (p < 0.0001) samples, downtrend in AM to PM TT3 (p = 0.0004) and FT3 samples (p < 0.0001), and AM to PM uptrend in rT3 samples (p < 0.0001). No difference was observed for TT4 between AM and PM. No significant sex differences were seen for any of the five thyroid hormones. CONCLUSION: When diagnosing thyroid disorders, it is important to have accurate measurement of thyroid hormones, and to acknowledge the diurnal fluctuation found, especially for FT3. Our study highlights the importance of standardization of collection times and implementation of LC-MS/MS in thyroid hormone measurement.

4.
JAMA Netw Open ; 3(3): e201357, 2020 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-32202644

RESUMEN

Importance: Alkaptonuria is an autosomal recessive disorder caused by pathogenic variants in the HGD gene. Deficiency of the HGD enzyme leads to tissue deposition of homogentisic acid (HGA), causing severe osteoarthropathies and cardiac valve degeneration. Although HGD is vital for the catabolism of tyrosine, which provides the basis for thyroid hormone synthesis, the prevalence of thyroid dysfunction in alkaptonuria is unknown. Objective: To assess thyroid structure and function in patients with alkaptonuria. Design, Setting, and Participants: A single-center cohort study was conducted in a tertiary referral center including patients with alkaptonuria followed up for a median of 93 (interquartile range, 48-150) months between February 1, 2000, and December 31, 2018. The alkaptonuria diagnosis was based on clinical presentation and elevated urine HGA levels. A total of 130 patients were considered for participation. Main Outcomes and Measures: Prevalence of thyroid dysfunction in adults with alkaptonuria compared with the general population. Thyrotropin and free thyroxine levels were measured by immunoassay and repeated in each patient a median of 3 (interquartile range, 2-22) times. Neck ultrasonographic scans were analyzed in a subset of participants. Logistic regression was used to test the association of thyroid dysfunction with age, sex, thyroid peroxidase (TPO) antibodies, serum tyrosine levels, and urine HGA levels. Results: Of the 130 patients, 5 were excluded owing to thyroidectomy as the cause of hypothyroidism. The study cohort consisted of 125 patients; the median age was 45 (interquartile range, 35-51) years. Most of the patients were men (72 [57.6%]). The prevalence of primary hyperthyroidism was 0.8% (1 of 125 patients), similar to 0.5% observed in the general population (difference, 0.003; 95% CI, -0.001 to 0.04; P = .88). The prevalence of primary hypothyroidism was 16.0% (20 of 125 patients), which is significantly higher than 3.7% reported in the general population (difference, 0.12; 95% CI, 0.10-0.24; P < .001). Women were more likely to have primary hypothyroidism than men (odds ratio, 10.99; 95% CI, 3.13-38.66; P < .001). Patients with TPO antibodies had a higher likelihood of primary hypothyroidism than those without TPO antibodies (odds ratio, 7.36; 95% CI, 1.89-28.62; P = .004). There was no significant difference in the prevalence of thyroid nodules between patients in this study (29 of 49 [59.2%]) vs the general population (68%) (difference, 0.088; 95% CI, -0.44 to 0.73; P = .20) or of cancer (7% vs 5%; difference, 0.01; 95% CI, -0.01 to 0.17; P = .86). Conclusions and Relevance: The high prevalence of primary hypothyroidism noted in patients with alkaptonuria in this study suggests that serial screening in this population should be considered and prioritized.


Asunto(s)
Alcaptonuria/metabolismo , Hipotiroidismo/epidemiología , Adulto , Alcaptonuria/complicaciones , Alcaptonuria/genética , Autoanticuerpos/sangre , Autoantígenos/inmunología , Estudios de Cohortes , Femenino , Ácido Homogentísico/orina , Humanos , Hipertiroidismo/epidemiología , Hipertiroidismo/genética , Hipotiroidismo/genética , Yoduro Peroxidasa/inmunología , Proteínas de Unión a Hierro/inmunología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Prevalencia , Pruebas de Función de la Tiroides , Glándula Tiroides/enzimología , Tirotropina/sangre , Tiroxina/sangre , Tirosina/sangre
6.
Clin Biochem ; 50(6): 318-322, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27890823

RESUMEN

OBJECTIVES: Patients with non-thyroidal illness syndrome have many abnormalities in thyroid hormone tests. Such patients have medical comorbidities associated with low serum proteins and are on multiple medications that interfere with thyroid hormone measurement by immunoassay platforms. It is unknown if these thyroid hormone measurements reflect physiologic conditions or if they are artifacts of testing methodology. METHODS: Fifty patients were selected from the intensive care unit (ICU) from our institution. Total and free thyroid hormones in plasma were measured by gold standard liquid chromatography-tandem mass spectrometry (LC-MSMS). The results were compared to the Roche Cobas 6000. Patient medical comorbidities and binding protein levels were assessed. RESULTS: Concentrations of total 3,5,5'-triidothyronine (TT3) and total thyroxine (TT4) were significantly more likely to be low by LC-MSMS compared to immunoassay. Free 3,5,5'-triidothyronine (FT3) levels were similar by immunoassay and LC-MSMS. However, FT4 concentrations were mildly elevated for many patients when measured by ultrafiltration LC-MSMS (19/50, 38%) compared to 1/50 (2%) when measured by immunoassay (p=0.0001). Decreased albumin and thyroxine binding globulin were common and patients were on an average of 11.7±5.0 medications, all factors known to interfere with results found on immunoassays. CONCLUSIONS: Marked discrepancies in thyroid hormone measurement were noted between reference LC-MSMS and a common immunoassay platform. It is hypothesized that T4 binding to low affinity albumin is displaced by several drugs, raising concentrations of FT4 by LC-MSMS compared to immunoassay, and that the immunoassay values are falsely decreased due to low binding proteins in our patient population.


Asunto(s)
Cromatografía Liquida/métodos , Unidades de Cuidados Intensivos , Espectrometría de Masas en Tándem/métodos , Enfermedades de la Tiroides/diagnóstico , Glándula Tiroides/metabolismo , Tiroxina/sangre , Triyodotironina/sangre , Adulto , Anciano , Biomarcadores/sangre , Femenino , Humanos , Inmunoensayo , Masculino , Persona de Mediana Edad , Enfermedades de la Tiroides/sangre , Pruebas de Función de la Tiroides , Adulto Joven
7.
J Steroid Biochem Mol Biol ; 162: 110-6, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26721696

RESUMEN

Our goals were to (1) develop an improved micro-method usable for neonates for steroid profile measurements and a method to measure androsterone, a key steroid in the recently described androgen backdoor pathway together, with dehydroepiandrosterone and (2) to assess if dehydroepiandrosterone diurnal concentration fluctuations exist potentially necessitating strict adherence to time of blood sample draw and requirement of separate time-dependent reference intervals. Liquid chromatography-tandem mass spectrometry was performed with an atmospheric pressure photoionization source [1]. For each sample 50µL (100µL for the backdoor pathway) of serum was deproteinized by adding 75µL (150µL for the backdoor pathway) of acetonitrile containing the internal standards. After centrifugation, 75µL (150µL for the backdoor pathway) of supernatant was diluted with 250µL of water and injected onto a Poroshell 120 EC-C8 column (SB-C8 column for the backdoor pathway). Within-run coefficients of variation ranged from 2.4 to 10.4% and between-day coefficients of variation from 2.9 to 11.2%. Comparison studies yielded correlation coefficient between 0.97 and 1.00 with recoveries of 90% or greater. Our methods analyze a 9 steroid profile and an additional 2 steroid profile (backdoor pathway) with minimal sample volume (usable in neonates optimizing early diagnosis of endocrinopathies and genetic diseases). Low limits of quantitation make these methods ideal for steroid measurement in women and prepubertal children. As diurnal variations of dehydroepiandrosterone and other steroids [2] concentrations are clinically significant we recommend that separate reference intervals be developed for 8 am, 8 pm, and midnight sample draws. The use of this approach in improving the diagnosis of patients with adrenal insufficiency and congenital adrenal hyperplasia is discussed.


Asunto(s)
Hiperplasia Suprarrenal Congénita/sangre , Insuficiencia Suprarrenal/sangre , Cromatografía Liquida/métodos , Esteroides/sangre , Espectrometría de Masas en Tándem/métodos , Hiperplasia Suprarrenal Congénita/diagnóstico , Insuficiencia Suprarrenal/diagnóstico , Andrógenos/sangre , Androsterona/sangre , Deshidroepiandrosterona/sangre , Humanos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA