Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Spec Oper Med ; 23(2): 73-77, 2023 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-37169530

RESUMEN

OBJECTIVE: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a method of gaining proximal control of noncompressible torso hemorrhage (NCTH). Catheter placement is traditionally confirmed with fluoroscopy, but few studies have evaluated whether ultrasound (US) can be used. METHODS: Using a pressurized human cadaver model, a certified REBOA placer was shown one of four randomized cards that instructed them to place the REBOA either correctly or incorrectly in Zone 1 (the distal thoracic aorta extending from the celiac artery to the left subclavian artery) or Zone 3 (in the distal abdominal aorta, from the aortic bifurcation to the lowest renal artery). Once the REBOA was placed, 10 US-trained locators were asked to confirm balloon placement via US. The participants were given 3 minutes to determine whether the catheter had been correctly placed, repeating this 20 times on two cadavers. RESULTS: Overall, US exhibited an average sensitivity of 83%, specificity of 76%, and accuracy of 80%. For Zone 1, US showed a sensitivity of 78% and specificity of 83%, and for Zone 3, a sensitivity of 88% and specificity of 76%. In addition, US exhibited a likelihood positive ratio (LR+) of 3.73 and a likelihood negative ratio (LR-) of 0.22 for either position, with similar numbers for Zone 1 (+4.57, -0.26) and Zone 3 (+3.16, -0.16). CONCLUSION: Ultrasound could prove to be a useful tool for confirming placement of a REBOA catheter, especially in austere environments.


Asunto(s)
Oclusión con Balón , Procedimientos Endovasculares , Choque Hemorrágico , Humanos , Procedimientos Endovasculares/métodos , Torso , Aorta Abdominal/diagnóstico por imagen , Resucitación/métodos , Oclusión con Balón/métodos , Cadáver , Choque Hemorrágico/diagnóstico por imagen , Choque Hemorrágico/terapia
2.
J Spec Oper Med ; 22(4): 50-54, 2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36525012

RESUMEN

BACKGROUND: Surgical cricothyrotomy (SC) is a difficult procedure with high failure rates in the battlefield environment. The difficulty of this procedure is compounded in a low-light tactical environment in which white light cannot be used. This study compared the use of red-green (RG) light and red (R) light in the performance of SC in a low-light environment. MATERIALS AND METHODS: Tactical Combat Casualty Care-certified navy corpsmen (n = 33) were provided 15 minutes of standardized instruction followed by hands-on practice with the Tactical CricKit and the H&H bougie-assisted Emergency Cricothyrotomy Kit. Participants acclimated to a dark environment for 30 minutes before performing SC on a mannequin with both devices using both R and RG light in a randomized order. Application time, success, participant preference, and participant confidence were analyzed. RESULTS: There were similarly high levels of successful placement (>87.5%) in all four cohorts. Light choice did not appear to affect placement time with either of the two kits. On Likert-scale surveys, participants reported that RG decreased difficulty (p < .0001) and increased confidence (p < .0001) in performing the procedure. CONCLUSION: RG light increased confidence and decreased perceived difficulty when performing SC, though no differences in placement time or success were observed.


Asunto(s)
Servicios Médicos de Urgencia , Maniquíes , Humanos , Servicios Médicos de Urgencia/métodos
3.
J Spec Oper Med ; 22(4): 87-92, 2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36525019

RESUMEN

BACKGROUND: Exsanguination is the leading cause of preventable posttraumatic death, especially in the prehospital arena. Traditional hemorrhage control methods involve packing the wound with hemostatic agents, providing manual pressure, and then applying a pressure dressing to stabilize the treatment. This is a lengthy process that frequently destabilizes upon patient transport. Conversely, the iTClamp, a compact wound closure device, is designed to rapidly seal wound edges mechanically, expediting clot formation at the site of injury. OBJECTIVES: To determine the efficacy of the iTClamp with and without wound packing in the control of a lethal junction hemorrhage. METHODS: Given the limited available information regarding the efficacy of the iTClamp in conjunction with traditional hemostatic agents, this study used a swine model of severe junctional hemorrhage. The goal was to compare a multiagent strategy using the iTClamp in conjunction with XSTAT to the traditional method of Combat Gauze packing with pressure dressing application. Readouts include application time, blood loss, and rebleed occurrence. RESULTS: Mean application times of the iTClamp treatment alone or in conjunction with other hemostatic agents were at least 75% faster than the application time of Combat Gauze with pressure dressing. Percent blood loss was not significantly different between groups but trended the highest for Combat Gauze treated swine, followed by iTClamp plus XSTAT, iTClamp alone and finally iTClamp plus Combat Gauze. CONCLUSION: The results from this study demonstrate that the iTClamp can be effectively utilized in conjunction with hemostatic packing to control junctional hemorrhages.


Asunto(s)
Técnicas Hemostáticas , Hemostáticos , Porcinos , Animales , Hemorragia/prevención & control , Hemorragia/etiología , Hemostáticos/uso terapéutico , Exsanguinación , Vendajes , Modelos Animales de Enfermedad
4.
Mil Med ; 2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36424914

RESUMEN

INTRODUCTION: Tactical Combat Casualty Care guidelines recommend packing junctional wounds with gauze, applying direct pressure for 3 minutes, and then securing with an external pressure dressing. This method is time-consuming, which can be problematic in a combat environment. Alternatively, the iTClamp has documented efficacy and rapid application. However, no studies have evaluated device application by military prehospital medical providers, such as Navy corpsmen, or their user experience with the device. MATERIALS AND METHODS: Research data derived from a protocol were approved by the Naval Medical Center Portsmouth's Institutional Review Board in compliance with all applicable federal regulations governing the protection of human subjects. Navy corpsmen with the current Tactical Combat Casualty Care certification applied the iTClamp or standard pressure dressing on a manikin model of femoral hemorrhage in a crossover study design. Each participant used both devices in a randomized fashion. Time to application was recorded, and participants completed Likert scale surveys to evaluate both devices for preference, ease of use, and physical assessment. A repeat assessment was performed 1 month later to assess skill atrophy. Repeated-measures ANOVA was used to compare application time. Likert scale survey data were analyzed using Mann-Whitney and Wilcoxon tests to compare survey data within and between time points, respectively. RESULTS: The application of the iTClamp was more than twice as fast as the application of pressure dressings at both the initial and follow-up evaluations. There was no statistically significant difference in application times between the first evaluation and the 30-day assessment of either device, indicating no atrophy in skill. While 65% and 52% of the participants expressed preference in for the iTClamp in their surveys during the initial and follow-up respective visits, the difference in preference was not statistically significant for either the initial or the follow-up survey. Open-ended survey responses yielded both perceived advantages and disadvantages for each treatment option. CONCLUSIONS: In austere or hostile environments, speed of treatment and extrication can have significant implications for the safety of both the patient and the medical providers. Hemorrhage control interventions must be both effective and easy to use for a prehospital provider to ensure its efficacy in a live battlefield situation. The iTClamp is small, simple, and fast to use, but its wide adoption in the field may be based on limitations perceived by participants, including narrow indications for use. However, based on our findings, it is reasonable to field the iTClamp depending on provider preference.

5.
Mil Med ; 185(7-8): e1290-e1293, 2020 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-31665415

RESUMEN

Wrist pain commonly affects military members and while most instances are benign, some require urgent orthopedic attention to prevent permanent loss of function. A 27-year-old male Marine while deployed presented with wrist pain after a seemingly benign fall during recreation. Radiographs were initially read as unremarkable and treated as a sprain. Though when reviewed by the Shock Trauma Platoon physicians, a perilunate dislocation was noted. After unsuccessful closed attempts to reduce injury, the Marine was sent to orthopedic surgery and underwent open reduction internal fixation and required a subsequent closed reduction and percutaneous pinning. Perilunate dislocations are uncommon but are among the most severe types of wrist injuries. This case is a reminder that proper evaluation of all injuries is critical. Proper evaluation of wrist injuries includes an attentive physical exam and careful examination of the radiographs; paying close attention to Gilula arcs and collinearity of the radius, lunate, and capitate. Prompt recognition and referral to specialty care for definitive treatment are important to maximize functional outcomes.


Asunto(s)
Traumatismos de la Muñeca , Adulto , Humanos , Luxaciones Articulares/cirugía , Hueso Semilunar/cirugía , Masculino , Procedimientos Ortopédicos , Radiografía , Traumatismos de la Muñeca/diagnóstico , Traumatismos de la Muñeca/cirugía
6.
Mil Med ; 184(Suppl 1): 367-373, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30901449

RESUMEN

Exsanguinating hemorrhage is a primary cause of battlefield death. The iTClamp is a relatively new device (FDA approval in 2013) that takes a different approach to hemorrhage control by applying mechanism wound closure. However, no previous studies have explored the feasibility of utilizing the iTClamp in conjunction with hemostatic packing. To fill this important gap in the literature, a novel swine model was developed, and a total of 12 trials were performed using QuikClot Combat Gauze or XSTAT sponges in conjunction with the iTClamp to treat arterial injuries through 5 cm or 10 cm skin incisions in the groin, axilla, or neck. First-attempt application success rate, application time, and blood loss were recorded. Hemostasis was achieved on all wounds, though reapplication was required in one Combat Gauze and three XSTAT applications. Application averaged ~50% slower for Combat Gauze (M = 41 seconds, 95%CI: 22-32 seconds) than for XSTAT (M = 27 seconds, 95%CI: 35-47 seconds). XSTAT application was faster than Combat Gauze for each wound location and size. The 10 cm wounds took ~10 seconds (36%) longer to close (M = 27 seconds, 95%CI: 35-47 seconds) than the 5 cm wounds (M = 27 seconds, 95%CI: 35-47 seconds). Blood loss was similar for Combat Gauze (M = 51 mL, 95%CI: 25-76 mL) and XSTAT (M = 60 mL, 95%CI: 30-90 mL). Blood loss was roughly twice as great for 10 cm wounds (M = 73 mL, 95%CI: 47-100 mL) than for 5 cm wounds (M = 38 mL, 95%CI: 18-57 mL). This pilot study supports the feasibility of a novel model for testing the iTClamp in conjunction with hemostatic packing towards controlling junctional hemorrhage.


Asunto(s)
Exsanguinación/tratamiento farmacológico , Hemostáticos/normas , Procedimientos Quirúrgicos Vasculares/instrumentación , Animales , Modelos Animales de Enfermedad , Exsanguinación/prevención & control , Técnicas Hemostáticas/instrumentación , Hemostáticos/uso terapéutico , Proyectos Piloto , Porcinos/lesiones , Procedimientos Quirúrgicos Vasculares/métodos , Procedimientos Quirúrgicos Vasculares/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA