Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Circ Cardiovasc Interv ; 16(5): e012655, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37192308

RESUMEN

BACKGROUND: The LRT trial (Low-Risk Transcatheter Aortic Valve Replacement [TAVR]) demonstrated the safety and feasibility of TAVR in low-risk patients, with excellent 1- and 2-year outcomes. The objective of the current study is to provide the overall clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration at 4 years. METHODS: The prospective, multicenter LRT trial was the first Food and Drug Administration-approved investigational device exemption study to evaluate feasibility and safety of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis. Clinical outcomes and valve hemodynamics were documented annually through 4 years. RESULTS: A total of 200 patients were enrolled, and follow-up was available on 177 patients at 4 years. The rates of all-cause mortality and cardiovascular death were 11.9% and 3.3%, respectively. The stroke rate rose from 0.5% at 30 days to 7.5% at 4 years, and permanent pacemaker implantation rose from 6.5% at 30 days to 11.7% at 4 years. Endocarditis was detected in 2.5% of the cohort, with no new cases reported between 2 and 4 years. Transcatheter heart valve hemodynamics remained excellent post-procedure and were maintained (mean gradient 12.56±5.54 mm Hg and aortic valve area 1.69±0.52 cm2) at 4 years. At 30 days, HALT was observed in 14% of subjects who received a balloon-expandable transcatheter heart valve. There was no difference in valve hemodynamics between patients with and without HALT (mean gradient 14.94±5.01 mm Hg versus 12.3±5.57 mm Hg; P=0.23) at 4 years. The overall rate of structural valve deterioration was 5.8%, and there was no impact of HALT on valve hemodynamics, endocarditis, or stroke at 4 years. CONCLUSIONS: TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis was found to be safe and durable at 4 years. Structural valve deterioration rates were low irrespective of the type of valve, and the presence of HALT at 30 days did not affect structural valve deterioration, transcatheter valve hemodynamics, and stroke rate at 4 years. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02628899.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Prospectivos , Factores de Riesgo , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Hemodinámica , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Trombosis/etiología
2.
Cardiovasc Revasc Med ; 47: 72-75, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36266153

RESUMEN

Mitral valve disease is insidious and associated with a decreased quality of life and survival over time. Despite surgery being the standard of care, many patients are at prohibitive surgical risk. Furthermore, a substantial proportion of patients with symptomatic mitral valve disease fail stringent screening criteria for transcatheter mitral valve replacement (TMVR). The natural history of patients who fail screening is not well-characterized, and data are limited on the reasons for screen failure in this population. The Mitral Valve Screening Survey (MVSS) seeks to detail the clinical profile and natural history of patients who fail screening for TMVR. The MVSS is a prospective, multicenter registry enrolling up to 1000 consecutive subjects who, after screening for TMVR, are deemed not to be candidates. Subjects will be followed for 30 days after failing screening for TMVR and annually for up to 5 years with clinical evaluations. The primary study endpoint of the MVSS registry is all-cause mortality at 1 year. Additional secondary endpoints include all-cause mortality, hospitalizations, subsequent mitral valve intervention (transcatheter or surgical), reason for screen failure, and quality-of-life assessments at 30 days and annually up to 5 years of follow-up. The MVSS registry is the first prospective multicenter study to characterize the clinical and anatomical profile of patients who fail screening for TMVR while providing longitudinal clarification on the natural history and outcomes of these patients. CLINICAL TRIAL REGISTRATION: Mitral Valve Screening Survey (MVSS), https://clinicaltrials.gov/ct2/show/NCT04736667, NCT04736667.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Calidad de Vida , Estudios Prospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Resultado del Tratamiento
3.
Cardiovasc Revasc Med ; 48: 7-14, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36347732

RESUMEN

BACKGROUND: Dual-antiplatelet therapy (DAPT) with aspirin and a P2Y12 receptor inhibitor is the mainstay regimen for acute coronary syndrome (ACS) patients after percutaneous coronary intervention (PCI). We aimed to investigate DAPT compliance and switching patterns in ACS patients prescribed ticagrelor and aspirin. Secondly, we evaluated the impact of a pilot strategy of close surveillance telephone calls. METHODS: The study enrolled 150 consecutive ACS patients who underwent PCI and were prescribed DAPT (aspirin and ticagrelor). This cohort, the "close surveillance arm," then received telephone calls from a healthcare professional to inquire about DAPT for up to one year. These findings, and clinical outcomes, were then compared to a "historical arm" of ACS patients (n = 505) who received PCI and were prescribed DAPT before initiation of the program. Finally, healthcare providers were surveyed about their experience with prescribing DAPT. RESULTS: The rate of ticagrelor cessation trended lower in the close surveillance arm (22.00 % versus 31.70 %, p = 0.0783). The most common reasons for ticagrelor cessation were adverse medication reaction (dyspnea), bleeding, and financial burden. Nevertheless, the adverse events were few and similar between the two groups during follow-up. Over 96 % of healthcare providers surveyed stated that they worry about their patients' DAPT compliance post-PCI. CONCLUSION: Noncompliance and switching medications are still common for patients who undergo PCI for ACS. A close surveillance program identified patients at risk for medication cessation or switching and could potentially mitigate this phenomenon and improve quality of care.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Ticagrelor/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Quimioterapia Combinada , Infarto del Miocardio/etiología , Aspirina/efectos adversos , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/tratamiento farmacológico , Resultado del Tratamiento
4.
Genet Med ; 24(5): 1062-1072, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35331649

RESUMEN

PURPOSE: The Mayo-Baylor RIGHT 10K Study enabled preemptive, sequence-based pharmacogenomics (PGx)-driven drug prescribing practices in routine clinical care within a large cohort. We also generated the tools and resources necessary for clinical PGx implementation and identified challenges that need to be overcome. Furthermore, we measured the frequency of both common genetic variation for which clinical guidelines already exist and rare variation that could be detected by DNA sequencing, rather than genotyping. METHODS: Targeted oligonucleotide-capture sequencing of 77 pharmacogenes was performed using DNA from 10,077 consented Mayo Clinic Biobank volunteers. The resulting predicted drug response-related phenotypes for 13 genes, including CYP2D6 and HLA, affecting 21 drug-gene pairs, were deposited preemptively in the Mayo electronic health record. RESULTS: For the 13 pharmacogenes of interest, the genomes of 79% of participants carried clinically actionable variants in 3 or more genes, and DNA sequencing identified an average of 3.3 additional conservatively predicted deleterious variants that would not have been evident using genotyping. CONCLUSION: Implementation of preemptive rather than reactive and sequence-based rather than genotype-based PGx prescribing revealed nearly universal patient applicability and required integrated institution-wide resources to fully realize individualized drug therapy and to show more efficient use of health care resources.


Asunto(s)
Citocromo P-450 CYP2D6 , Farmacogenética , Centros Médicos Académicos , Secuencia de Bases , Citocromo P-450 CYP2D6/genética , Genotipo , Humanos , Farmacogenética/métodos
5.
Catheter Cardiovasc Interv ; 99(3): 896-903, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34505737

RESUMEN

OBJECTIVES: We sought to report details of the incidence, organisms, clinical course, and outcomes of prosthetic valve endocarditis (PVE) after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: PVE remains a rare but devastating complication of aortic valve replacement. Data regarding PVE after TAVR in low-risk patients are lacking. METHODS: We performed a detailed review of all patients in the low-risk TAVR trials who underwent TAVR from 2016 to 2020 and were adjudicated to have definitive PVE by the independent Clinical Events Committee. RESULTS: We analyzed 396 low-risk patients who underwent TAVR (including 72 with bicuspid valves). PVE occurred in 11 patients at a median 379 days (210, 528) from TAVR. The incidence within the first 30 days was 0%; days 31-365, 1.5%; and after day 365, 2.8%. The most common organism identified was Streptococcus (n = 4/11). Early PVE (≤ 365 days) occurred in five patients, of whom three demonstrated evidence of embolic stroke and two underwent surgical aortic valve re-intervention. Late PVE (> 365 days) occurred in six patients, of whom thee demonstrated evidence of embolic stroke and only one underwent surgical aortic valve re-intervention. Of the six patients with evidence of embolic stroke, two died, two were discharged to rehabilitation, and two were discharged home with home care. CONCLUSIONS: PVE was infrequent following TAVR in low-risk patients but was associated with substantial morbidity and mortality. Embolic stroke complicated the majority of PVE cases, contributing to worse outcomes in these patients. Efforts must be undertaken to minimize PVE in TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Endocarditis/etiología , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/epidemiología , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
6.
J Am Med Inform Assoc ; 27(1): 154-158, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31591640

RESUMEN

Pharmacogenomics (PGx) clinical decision support integrated into the electronic health record (EHR) has the potential to provide relevant knowledge to clinicians to enable individualized care. However, past experience implementing PGx clinical decision support into multiple EHR platforms has identified important clinical, procedural, and technical challenges. Commercial EHRs have been widely criticized for the lack of readiness to implement precision medicine. Herein, we share our experiences and lessons learned implementing new EHR functionality charting PGx phenotypes in a unique repository, genomic indicators, instead of using the problem or allergy list. The Gen-Ind has additional features including a brief description of the clinical impact, a hyperlink to the original laboratory report, and links to additional educational resources. The automatic generation of genomic indicators from interfaced PGx test results facilitates implementation and long-term maintenance of PGx data in the EHR and can be used as criteria for synchronous and asynchronous CDS.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Registros Electrónicos de Salud , Genómica , Farmacogenética , Medicina de Precisión , Técnicas de Apoyo para la Decisión , Humanos , Medicina de Precisión/métodos
7.
Stud Health Technol Inform ; 245: 1255, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29295340

RESUMEN

Clinical use of pharmacogenomic (PGx) knowledge at the bedside is new and complex. Our program has implemented multiple PGx-CDS interventions in different clinical settings and in multiple commercial EHRs. Herein, we discuss lessons learned and propose general technical guidelines related to PGx implementation.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Registros Electrónicos de Salud , Farmacogenética , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA