Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
Am J Cardiol ; 230: 50-57, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39117008

RESUMEN

Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been associated with favorable outcomes in patients with degenerated stentless bioprosthesis. However, whether the outcomes after ViV TAVR for failed stentless bioprosthesis differ between balloon-expandable valves (BEVs) and self-expanding valves (SEVs) remains unknown. Therefore, we retrospectively analyzed 59 consecutive patients who underwent ViV TAVR for failed stentless bioprsothesis with BEVs (n = 42) versus SEVs (n = 17) in a single-health care system between 2013 and 2022. Overall, the mean age was 70.8 years and 74.6% were men. The mean transcatheter valve size was 26.3 ± 2.2 mm for BEVs and 26.4 ± 4 mm for SEVs (p = 0.93). The mean Society of Thoracic Surgeons score was 6.0 ± 3.6 for BEVs and 7.5 ± 5.5 for SEVs (p = 0.22). Compared with patients who received BEVs, those who received SEVs had higher rates of device malposition (2.4% vs 23.5%, p <0.01), postdeployment balloon dilation (11.9% vs 35.5%, p = 0.04) and need for a second transcatheter device (2.4% vs 35.5%, p <0.01). However, both groups showed similar improvement in aortic valve function at 30-day and 1-year follow-up (incidence of 1-year severe patient-prosthesis mismatch in BEVs: 17.6% vs 14.3% in SEVs, p = 0.78). The 1- and 3-year mortality did not differ between BEVs and SEVs (11.9% vs 11.8% and 25% vs 30%, respectively, Log rank p = 0.9). In conclusion, performing ViV TAVR for failed stentless bioprsothesis is technically challenging, especially when using SEVs; however, satisfactory positioning is possible in most cases, with excellent hemodynamic and clinical outcomes with BEVs and SEVs.

2.
Am J Cardiol ; 231: 11-19, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39209242

RESUMEN

Data on the long-term outcomes of prosthesis patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) remain controversial. This study aimed to investigate the incidence and clinical outcomes of measured PPM (PPMM) and predicted PPM (PPMP) in patients who underwent TAVI. This is a retrospective analysis of 3,016 patients who underwent TAVI at a large health care system between 2012 and 2021. Effective orifice area indexed to body surface area (EOAi) was measured at discharge using the continuity equation. EOAi was predicted according to the published predictive tables for each model and size of the valve. Primary end point was 5-year survival rate. Mean age was 80 years, and 55.6% were male. The mean Society of Thoracic Surgeons risk score was 4.66%. 74.9% of patients received a balloon-expandable valve (BEV), and 25.1% received a self-expanding valve (SEV). The incidence of severe PPM was markedly lower when defined by predicted versus measured EOAi (0.8% vs 6.3%, p <0.001) and when assessed in SEV versus BEV (5.3% vs 6.6%, p = 0.02). Neither severe PPMp nor severe PPMM was associated with 5-year mortality (hazard ratio 1.26, 95% confidence interval 0.96 to 1.66, p = 0.095; hazard ratio 1.03, 95% confidence interval 0.42 to 2.49, p = 0.954, respectively), irrespective of the presence of high residual pressure gradient. Neither BEV nor SEV was associated with an increased 5-year mortality, irrespective of PPM definition or severity. In this large health care system analysis, neither severe PPMP nor severe PPMM was associated with 5-year all-cause mortality. There was no difference between BEV and SEV in terms of mortality, irrespective of the definition or severity of PPM.

4.
Curr Cardiol Rep ; 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39150673

RESUMEN

PURPOSE OF REVIEW: Transcatheter Aortic Valve Replacement (TAVR) has become the preferred treatment approach for many patients with symptomatic severe aortic valve stenosis (SsAS), particularly those who are deemed at high surgical risk. However, in low-risk surgical patients (LSRP) with SsAS, the choice between TAVR and surgical aortic valve replacement (SAVR) is often a matter of debate and depends on several clinical and anatomical considerations. RECENT FINDINGS: Midterm data show similar clinical outcomes and durability of TAVR and SAVR bioprosthetic valves in LRSP. Data on long term durability and outcomes of TAVR in LRSP remains scarce. Both TAVR and SAVR are reasonable options in LRSP with SsAS. Nevertheless, many of these LRSP are expected to outlive their bioprosthetic valves and planning for the second aortic valve replacement should begin at the time of the index procedure with special consideration for coronary re-access, risk for coronary obstruction, and prothesis patient mismatch.

5.
Eur Heart J ; 45(33): 3031-3041, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Anciano , Estudios Prospectivos , Estenosis de la Válvula Aórtica/cirugía , Falla de Prótesis , Diseño de Prótesis , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Oclusión Coronaria/cirugía , Complicaciones Posoperatorias/epidemiología
6.
Am J Cardiol ; 220: 33-38, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38582315

RESUMEN

In acute coronary syndromes (ACS), revascularization is the standard of care. However, trials comparing contemporary coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) are limited. Optimal revascularization in patients with multivessel coronary artery disease (MV-CAD) presenting with ACS is unclear. This is a multicentered, retrospective observational study from a large hospital system in the United States. We abstracted data in patients with MV-CAD and ACS from 2018 to 2022 who underwent revascularization with PCI, CABG, or medical management (MM). We evaluated multivariate statistics comparing categorical variables and outcomes, including all-cause mortality and myocardial infarction (MI) at 1 year. All logistic and Cox proportional-hazard models were balanced using inverse probability treatment weights accounting for age and gender. There were 295 patients with CABG (median age 66 years [interquartile range 59.7 to 73.1]; 73% male), 1,559 patients with PCI (median age 68.3 years [interquartile range 60 to 76.6]; 69.1% male], and 307 patients with MM (median age 70 years [60.9 to 77.1] 74% male]. Patients revascularized with PCI had greater all-cause mortality at 1 year (14.1% vs 5.1%; hazard ratio 2.4, confidence interval [1.5 to 3.8], p <0.001) and similar mortality to MM (13.4%). CABG also showed a reduced 1-year MI rate compared with PCI (1.7% vs 3.9%; hazard ratio 0.36, confidence interval 0.21 to 0.61, p ≤0.001), with a similar 1-year rate of MI to MM (3.9%). In conclusion, CABG is associated with lower mortality than are PCI and MM, and repeat ACS events at 1 year in patients with ACS and MV-CAD.


Asunto(s)
Síndrome Coronario Agudo , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Anciano , Síndrome Coronario Agudo/cirugía , Síndrome Coronario Agudo/mortalidad , Persona de Mediana Edad , Estudios Retrospectivos , Intervención Coronaria Percutánea/métodos , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Revascularización Miocárdica/métodos , Revascularización Miocárdica/estadística & datos numéricos , Causas de Muerte/tendencias , Estados Unidos/epidemiología
7.
Am J Cardiol ; 220: 67-76, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38582312

RESUMEN

Transcatheter tricuspid valve intervention (TTVI) has recently emerged as a promising alternative to surgery for tricuspid regurgitation (TR). However, a significant proportion of patients fail screening for TTVI, and little is known about their characteristics and natural history. This study sought to investigate causes of screen failure and outcomes of patients declined for TTVI. This was a retrospective single-center study of 32 patients who were ineligible for participation in transcatheter tricuspid valve replacement and tricuspid transcatheter edge-to-edge repair trials. Patients were classified into 2 groups according to the therapy they received: optimized medical therapy (OMT) group or intervention group. The mean age was 82 ± 7.8 years and 68.8% were women. The most common reasons for TTVI exclusion were anatomic/procedural impediment (53.1%), inclusion criteria not met (40.6%), and multivalvular disease (6.3%). Overall, 19 patients (59.4%) did not undergo subsequent tricuspid intervention. The clinical outcomes of these patients who received OMT alone were poor, with a 1-year composite of cardiac death or heart failure readmission of 47.4%. These rates were worse than in patients who subsequently underwent an intervention, albeit not statistically significant (OMT: 47.7% vs 23.1% interventions, p = 0.3), and were significantly more pronounced in the subgroup of patients who were excluded for anatomic/procedural limitations (OMT: 70% vs 14.3% interventions, p = 0.05). In conclusion, patients ineligible for TTVI, particularly, those with anatomic/procedural limitations, and treated medically have poor outcomes. These data underscore the importance of earlier referral and support the need for further transcatheter therapy iterations.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Femenino , Masculino , Estudios Retrospectivos , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Resultado del Tratamiento , Estudios de Seguimiento , Tamizaje Masivo/métodos
8.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38587261

RESUMEN

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Bioprótesis/efectos adversos , Insuficiencia Cardíaca , Estimación de Kaplan-Meier , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Falla de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
9.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599690

RESUMEN

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/métodos
10.
Am J Cardiol ; 220: 102-110, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38432334

RESUMEN

Proximal radial artery (PRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (DRA) access in the anatomical snuffbox preserves the RA but safety and potential detrimental effects on hand function are unknown. We aimed to assess hand function and complications after DRA and PRA. In this single-center trial, 300 patients were randomly allocated 1:1 to cardiac catheterization through DRA or PRA. The primary end point of change in hand function from baseline to 1 year was a composite of the Quick Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, hand grip test, and thumb-forefinger pinch test. The secondary end points included access feasibility and complications. Of 216 patients with 1-year completed follow-up, 112 were randomly allocated to DRA and 104 to PRA, with balanced demographics and procedural characteristics. Both groups had similar access site bleeding rates (DRA 0% vs PRA 1.4%, p = 0.25). Radial artery occlusion occurred in 1 PRA patient versus 2 in DRA. There was no significant difference in change of hand function, median (interquartile range) hand grip (DRA 0.7 [-3 to 4.5] vs PRA 1.3 [-2 to 4.3] kg, p = 0.57), pinch grip (DRA -0.1 [-1.1 to 1] vs PRA -0.3 [-1 to 0.7] kg, p = 0.66), and Quick DASH (DRA 0 [-6.6 to 2.3] vs PRA 0 [-4.6 to 2.9] points, p = 0.58). The composite of hand function was comparable between PRA and DRA. In conclusion, DRA is a safe strategy for cardiac catheterization, with a low complication rate. Compared with PRA, there is no increased risk of hand dysfunction or radial artery occlusion at 1 year.


Asunto(s)
Cateterismo Cardíaco , Arteria Radial , Humanos , Masculino , Femenino , Cateterismo Cardíaco/métodos , Persona de Mediana Edad , Anciano , Fuerza de la Mano/fisiología , Estudios de Seguimiento , Factores de Tiempo
11.
Circ Cardiovasc Interv ; 17(4): e013581, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38436084

RESUMEN

BACKGROUND: Transcatheter edge-to-edge mitral valve (MV) repair (TEER) is an effective treatment for patients with primary mitral regurgitation at prohibitive risk for surgical MV repair (MVr). High-volume MVr centers and high-volume TEER centers have better outcomes than low-volume centers, respectively. However, whether MVr volume predicts TEER outcomes remains unknown. We hypothesized that high-volume MV surgical centers would have superior risk-adjusted outcomes for TEER than low-volume centers. METHODS: We combined data from the American College of Cardiology/Society of Thoracic Surgeons Transcatheter Valve Therapy registry and the Society of Thoracic Surgeons adult cardiac surgery database. MVr was defined as leaflet resection or artificial chords with or without annuloplasty and was evaluated as a continuous variable and as predefined categories (<25, 25-49, and ≥50 MV repairs/year). A generalized linear mixed model was used to evaluate risk-adjusted in-hospital/30-day mortality, 30-day heart failure readmission, and TEER success (mitral regurgitation ≤2+ and gradient <5 mm Hg). RESULTS: The study comprised 41 834 patients from 500 sites of which 332 (66.4%) were low, 102 (20.4%) intermediate, and 66 (13.2%) high-volume surgical centers (P<0.001). TEER success was 54.6% and was not statistically significantly different across MV surgical site volumes (P=0.4271). TEER mortality at 30 days was 3.5% with no significant difference across MVr volume on unadjusted (P=0.141) or adjusted (P=0.071) analysis of volume as a continuous variable. One-year mortality was 15.0% and was lower for higher MVr volume centers when adjusted for clinical and demographic variables (P=0.027). Heart failure readmission at 1 year was 9.4% and was statistically significantly lower in high-volume centers on both unadjusted (P=0.017) or adjusted (P=0.015) analysis. CONCLUSIONS: TEER can be safely performed in centers with low volumes of MV repair. However, 1-year mortality and heart failure readmission are superior at centers with higher MVr volume.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Insuficiencia Cardíaca/etiología , Hospitales
14.
Proc (Bayl Univ Med Cent) ; 37(2): 205-209, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38343487

RESUMEN

Background: Conduction abnormality requiring the implantation of a permanent pacemaker (PPM) is a well-known and clinically important complication of transcatheter aortic valve replacement (TAVR). However, PPM implantation may result in lead-associated tricuspid valve regurgitation (TR). This study sought to determine the incidence and progression of TR following PPM implantation after TAVR. Methods: This was a retrospective review of all echocardiograms of patients who underwent PPM following TAVR at the Baylor Scott & White hospitals from 2012 to 2021. The primary endpoint was TR progression at 30 days and 1 year. A subanalysis comparing the change in TR progression between small and large TAVR devices was also conducted. Secondary outcomes included all-cause death at 30 days and 1 year. Results: Out of the 2744 patients who underwent TAVR between April 2012 and August 2021, 177 patients (6.5%) subsequently received a new PPM. There was a statistically significant progression of TR at 1-year follow-up (McNemar's P value = 0.02). TR progression rates were comparable between the small and large valve groups at 1-year follow-up (4% vs 11%, P = 0.09, respectively). Conclusion: In this single healthcare system study, we demonstrated a significant progression of TR in patients with PPM post TAVR at 1 year.

15.
Proc (Bayl Univ Med Cent) ; 37(2): 218-226, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38343489

RESUMEN

Background: In March 2022, a COVID-19 outbreak disrupted the global supply of iodine contrast media (ICM). Healthcare systems implemented contrast-saving strategies to maintain their remaining ICM supplies. This study sought to determine the impact of contrast shortage on the incidence of contrast-associated acute kidney injury (CA-AKI). Methods: This was a retrospective study of 265 patients undergoing 278 percutaneous coronary interventions (PCI) during 4-month periods prior to (9/1/2021 to 12/31/2021) and during (5/1/2022 to 8/31/2022) contrast shortage at a single center. The primary endpoint was the incidence of CA-AKI between study periods. Results: A total of 148 and 130 PCIs were performed before and during contrast shortage, respectively. The incidence of CA-AKI significantly decreased from 11.5% to 4.6% during contrast shortage (P = 0.04). During the shortage, average contrast volume per PCI was significantly lower (123 ± 62 mL vs 88 ± 46 mL, P < 0.001), while coronary imaging was significantly higher (34.3% vs 50%, P = 0.009) compared to preshortage. All-cause mortality at discharge was comparable between study periods (2.8% vs 3.3%, respectively; P = 0.90). Conclusion: The scarcity of ICM for PCI procedures in this single-center experience was associated with a significant increase in the utilization of intravascular imaging and a significant reduction in CA-AKI.

16.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38224255

RESUMEN

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de Registros
17.
Cardiovasc Revasc Med ; 61: 99-109, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37867120

RESUMEN

BACKGROUND: Calcific aortic stenosis is the principal indication for transcatheter aortic valve replacement (TAVR). Comorbid mitral annular calcification (MAC) is often present in patients undergoing TAVR. Limited data exist on the impact of MAC on TAVR outcomes. We conducted a systematic review and meta-analysis to explore the effects of MAC and concomitant mitral valve dysfunction (MVD) on TAVR outcomes. METHODS: A comprehensive literature review was conducted using PubMed, Embase, Google Scholar, ClinicalTrials.gov, Scopus, and OVID for studies until March 20, 2023. Using the random-effects Mantel-Haenszel method, we calculated pooled risk ratios (RRs) and their corresponding 95 % confidence intervals (CIs) for all dichotomous variables. RESULTS: Six studies comprising 5822 patients (2541 with MAC [severe MAC (>4 mm thickness) 583; non-severe MAC 1958; 400 with MVD; and 1071 without MVD], 3281 without MAC) met inclusion criteria. At 30 days and 1 year, no significant differences were observed between the overall MAC and no MAC groups in terms of mortality, stroke, and permanent pacemaker implantation. However, MAC with MVD was associated with a higher risk of all-cause mortality compared to MAC without MVD at 30 days (RR = 3.43, 95 % CI 2.04-5.76, P < 0.00001) and at 1 year (RR = 2.44, 95 % CI 1.85-3.20, P < 0.00001). Moreover, the risk of cardiovascular mortality was higher in patients with MAC and MVD compared to those with MAC alone (RR = 2.77, 95 % CI 1.89-4.06, P < 0.00001). Additionally, patients with severe MAC had a higher risk of major bleeding at 30 days compared to the non-severe MAC group (RR = 1.33, 95 % CI 1.04-1.69, P = 0.02). CONCLUSION: TAVR appears to be safe in patients with non-severe MAC, but severe MAC is associated with a higher risk of major bleeding and concomitant MVD increases the mortality risk in patients undergoing TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Hemorragia/etiología , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
19.
Artículo en Inglés | MEDLINE | ID: mdl-37962288

RESUMEN

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA