Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Appl Radiat Isot ; 208: 111275, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38484591

RESUMEN

Accurate measurements of photonuclear reaction cross sections are crucial for a number of applications, including radiation shielding design, absorbed dose calculations, reactor physics and engineering, nuclear safeguard and inspection, astrophysics, and nuclear medicine. Primarily motivated by the study of the production of selected radionuclides with high-energy photon beams (mainly 225Ac, 47Sc, and 67Cu), we have established a methodology for the measurement of photonuclear reaction cross sections with the microtron accelerator available at the Swiss Federal Institute of Metrology (METAS). The proposed methodology is based on the measurement of the produced activity with a High Purity Germanium (HPGe) spectrometer and on the knowledge of the photon fluence spectrum through Monte Carlo simulations. The data analysis is performed by applying a Bayesian fitting procedure to the experimental data and by assuming a functional trend of the cross section, in our case a Breit-Wigner function. We validated the entire methodology by measuring a well-established photonuclear cross section, namely the 197Au(γ, n)196Au reaction. The results are consistent with those reported in the literature.

2.
J Robot Surg ; 18(1): 53, 2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38280113

RESUMEN

There is a lack of training curricula and educational concepts for robotic-assisted surgery (RAS). It remains unclear how surgical residents can be trained in this new technology and how robotics can be integrated into surgical residency training. The conception of a training curriculum for RAS addressing surgical residents resulted in a three-step training curriculum including multimodal learning contents: basics and simulation training of RAS (step 1), laboratory training on the institutional robotic system (step 2) and structured on-patient training in the operating room (step 3). For all three steps, learning content and video tutorials are provided via cloud-based access to allow self-contained training of the trainees. A prospective multicentric validation study was conducted including seven surgical residents. Transferability of acquired skills to a RAS procedure were analyzed using the GEARS score. All participants successfully completed RoSTraC within 1 year. Transferability of acquired RAS skills could be demonstrated using a RAS gastroenterostomy on a synthetic biological organ model. GEARS scores concerning this procedure improved significantly after completion of RoSTraC (17.1 (±5.8) vs. 23.1 (±4.9), p < 0.001). In step 3 of RoSTraC, all participants performed a median of 12 (range 5-21) RAS procedures on the console in the operation room. RoSTraC provides a highly standardized and comprehensive training curriculum for RAS for surgical residents. We could demonstrate that participating surgical residents acquired fundamental and advanced RAS skills. Finally, we could confirm that all surgical residents were successfully and safely embedded into the local RAS team.


Asunto(s)
Internado y Residencia , Procedimientos Quirúrgicos Robotizados , Robótica , Entrenamiento Simulado , Humanos , Competencia Clínica , Curriculum , Estudios Prospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Robótica/educación , Entrenamiento Simulado/métodos
3.
Cell Rep ; 42(1): 111937, 2023 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-36640314

RESUMEN

Group 1 innate lymphoid cells (ILCs) comprise a heterogeneous family of cytotoxic natural killer (NK) cells and ILC1s. We identify a population of "liver-type" ILC1s with transcriptional, phenotypic, and functional features distinct from those of conventional and liver-resident NK cells as well as from other previously described human ILC1 subsets. LT-ILC1s are CD49a+CD94+CD200R1+, express the transcription factor T-BET, and do not express the activating receptor NKp80 or the transcription factor EOMES. Similar to NK cells, liver-type ILC1s produce IFN-γ, TNF-α, and GM-CSF; however, liver-type ILC1s also produce IL-2 and lack perforin and granzyme-B. Liver-type ILC1s are expanded in cirrhotic liver tissues, and they can be produced from blood-derived ILC precursors in vitro in the presence of TGF-ß1 and liver sinusoidal endothelial cells. Cells with similar signature and function can also be found in tonsil and intestinal tissues. Collectively, our study identifies and classifies a population of human cross-tissue ILC1s.


Asunto(s)
Inmunidad Innata , Linfocitos , Humanos , Células Endoteliales , Células Asesinas Naturales , Hígado , Factores de Transcripción , Análisis de Secuencia de ARN
4.
Molecules ; 27(17)2022 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-36080438

RESUMEN

The commercial low-pressure column chromatographic 99Mo/99mTc generator represents a reliable source of onsite, ready-to-use 99mTc for industrial applications. These generators use fission-produced 99Mo of high specific activity, posing serious production challenges and raising proliferation concerns. Therefore, many concepts are aimed at using low-specific-activity (LSA) 99Mo. Nonetheless, the main roadblock is the low sorption capacity of the used alumina (Al2O3). This study investigates the feasibility of using commercial alumina incorporated with LSA 99Mo to develop a useful 99Mo/99mTc generator for industrial radiotracer applications. First, the adsorption profiles of some commercial alumina sorbents for LSA 99Mo were tested under different experimental conditions. Then, the potential materials to develop a 99Mo/99mTc generator were selected and evaluated regarding elution yield of 99mTc and purity. Among the sorbents investigated in this study, mesoporous alumina (SA-517747) presented a unique sorption-elution profile. It demonstrated a high equilibrium and dynamic sorption capacity of 148 ± 8 and 108 ± 6 mg Mo/g. Furthermore, 99mTc was eluted with high yield and adequate chemical, radiochemical, and radionuclidic purity. Therefore, this approach provides an efficient and cost-effective way to supply onsite 99mTc for radiotracer applications independent of fission-produced 99Mo technology.


Asunto(s)
Óxido de Aluminio , Tecnecio , Óxido de Aluminio/química , Molibdeno/química , Radioisótopos/química , Radiofármacos/química , Tecnecio/química
5.
Nanomaterials (Basel) ; 12(9)2022 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-35564296

RESUMEN

99Mo/99mTc generators play a significant role in supplying 99mTc for diagnostic interventions in nuclear medicine. However, the applicability of using low specific activity (LSA) 99Mo asks for sorbents with high sorption capacity. Herein, this study aims to evaluate the sorption behavior of LSA 99Mo towards several CeO2 nano-sorbents developed in our laboratory. These nanomaterials were prepared by wet chemical precipitation (CP) and hydrothermal (HT) approaches. Then, they were characterized using XRD, BET, FE-SEM, and zeta potential measurements. Additionally, we evaluated the sorption profile of carrier-added (CA) 99Mo onto each material under different experimental parameters. These parameters include pH, initial concentration of molybdate solution, contact time, and temperature. Furthermore, the maximum sorption capacities were evaluated. The results reveal that out of the synthesized CeO2 nanoparticles (NPs) materials, the sorption capacity of HT-1 and CP-2 reach 192 ± 10 and 184 ± 12 mg Mo·g-1, respectively. For both materials, the sorption kinetics and isotherm data agree with the Elovich and Freundlich models, respectively. Moreover, the diffusion study demonstrates that the sorption processes can be described by pore diffusion (for HT-synthesis route 1) and film diffusion (for CP-synthesis route 2). Furthermore, the thermodynamic parameters indicate that the Mo sorption onto both materials is a spontaneous and endothermic process. Consequently, it appears that HT-1 and CP-2 have favorable sorption profiles and high sorption capacities for CA-99Mo. Therefore, they are potential candidates for producing a 99Mo/99mTc radionuclide generator by using LSA 99Mo.

7.
Appl Radiat Isot ; 168: 109551, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33307436

RESUMEN

Accelerator driven fast nuclear reactors cooled by lead-bismuth eutectic (LBE) are developed for transmuting long-lived radionuclides in spent nuclear fuel. Due to the nature of the coolant, operating the reactor will result in a production of 210Po by neutron capture. Understanding the behavior of this highly radiotoxic nuclide in the event of a failure of the window separating the evacuated proton beam guide from the reactor core is required for safety assessments. The present work aims at acquiring this knowledge by studying the evaporation of polonium from neutron-irradiated LBE and its deposition in a scaled down model of the beam tube. Experimental results along with Monte Carlo simulations indicate that polonium adsorbs as a single species with an adsorption enthalpy of approximately -156 kJ/mol.

8.
GMS Hyg Infect Control ; 15: Doc19, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32782898

RESUMEN

Since the beginning of the pandemic, there have been restrictions in the daily care of surgical patients - both elective and emergency. Readying supply capacities and establishing isolation areas and areas for suspected cases in the clinics have led to keeping beds free for treating (suspected) COVID-19 cases. It was therefore necessary to temporarily postpone elective surgery. Now, elective care can be gradually resumed with the second phase of the pandemic in Germany. However, it remains the order of the day to adapt pre-, intra- and post-operative procedures to the new COVID-19 conditions while maintaining specialized hygiene measures. This concerns the correct procedure for the use of personal protective materials as well as process adjustment for parallel treatment of positive and negative patients in the central OR, and handling of aerosols in the operating theater, operating room, and surgical site under consideration of staff and patient protection. Although dealing with surgical smoke in the operating theater has long been criticized, COVID-19 is forcing a renaissance in this area. Finally, the choice of surgical method, whether open surgery or minimally invasive procedures, is critical in determining how many colleagues are exposed to the risk of infection from COVID-19 patients, sometimes for hours. Here, robot-assisted surgery can comply with the pandemic's requirement to "keep your distance" in a unique way, since the surgeon can operate at virtually any distance from the surgical site, at least with regard to aerosol formation and exposure.

9.
Zentralbl Chir ; 145(3): 225-233, 2020 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-32498104

RESUMEN

Robotic low anterior resection in rectal carcinoma is becoming increasing common in Europe. There may be oncological and functional advantages as compared to laparoscopic approaches. The new generation of surgical robots, such as the Da Vinci Xi systems from Intuitive, enlarges the range of robotic access, especially in the mobilisation of the left flexure. Thus, robotic low anterior resection can now be performed safely, with low morbidity and without hybrid support. In this paper, the setup of the robotic system, port placement and surgical steps of robotic low anterior rectal resection are explained. Special features of Da Vinci Xi- and -X-systems are emphasised. Potential advantages of the robotic access - such as 3-dimensional visualisation of the surgical field, wrist-like movements of instruments and increased precision - may provide better results in rectal surgery than with laparoscopic access. Nevertheless, the evidence is still too weak to recommend robotic low anterior resection as the standard procedure in rectal cancer.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo , Laparoscopía , Neoplasias del Recto , Procedimientos Quirúrgicos Robotizados , Humanos , Proctectomía
10.
Chimia (Aarau) ; 73(11): 947-949, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31753079
11.
Ann Surg ; 270(5): 755-761, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31634179

RESUMEN

BACKGROUND: Previous data suggest that the incidence of hypoparathyroidism after surgery for Graves disease (GD) is lower after subtotal thyroidectomy compared to total thyroidectomy (TT). The present study evaluated the incidence of postoperative hypoparathyroidism after near-total (NTT) versus TT in GD. METHODS/DESIGN: In a multicenter prospective randomized controlled clinical trial, patients with GD were randomized intraoperatively to NTT or TT. Primary endpoint was the incidence of transient postoperative hypoparathyroidism. Secondary endpoints were permanent hypoparathyroidism, transient recurrent laryngeal nerve palsy (RLNP), reoperations for bleeding, inadvertently removed parathyroid glands, and recurrent hyperthyroidism after 12 months. RESULTS: Eighteen centers randomized 205 patients to either TT (n = 102) or NTT (n = 103) within 16 months. According to intention-to-treat postoperative transient hypoparathyroidism occurred in 19% (20/103) patients after NTT and in 21% (21 of 102) patients after TT (P = 0.84), which persisted >6 months in 2% and 5% of the NTT and TT groups (P = 0.34). The rates of parathyroid autotransplantation (NTT 24% vs TT 28%, P = 0.50) and transient RLNP (NTT 3% vs TT 4%, P = 0.35) was similar in both groups. The rate of reoperations for bleeding tended to be higher in the NTT group (3% vs 0%, P = 0.07) and the rate of inadvertently removed parathyroid glands was significantly higher after NTT (13% vs 3%, P = 0.01). An existing endocrine orbitopathy improved in 35% and 24% after NTT and TT (P = 0.61). Recurrent disease occurred in only 1 patient after TT (P = 0.34). CONCLUSION: NTT for GD is not superior to TT regarding transient postoperative hypoparathyroidism.


Asunto(s)
Enfermedad de Graves/diagnóstico , Enfermedad de Graves/cirugía , Hipoparatiroidismo/cirugía , Glándulas Paratiroides/trasplante , Tiroidectomía/métodos , Adulto , Femenino , Estudios de Seguimiento , Humanos , Hipoparatiroidismo/etiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/cirugía , Estudios Prospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tiroidectomía/efectos adversos , Factores de Tiempo , Trasplante Autólogo/métodos , Resultado del Tratamiento , Adulto Joven
12.
J Environ Radioact ; 208-209: 106026, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31437807

RESUMEN

Increased uranium (U) concentrations are found in certain ground and surface waters of the Swiss Plateau. Analysis of more than 100 public fountains revealed that increased 238U concentrations frequently occur close to the interface between the Lower Freshwater Molasse and the Upper Marine Molasse, cropping out in the western part of the Swiss Molasse Basin. Out of these locations, Mont Vully, situated ca. 20 km west of Berne, was studied in detail. As this hill consists of the two aforementioned stratigraphic Molasse units, it represents an ideal case study. Two springs at the northern slopes of Mont Vully exhibit the highest 238U concentrations with more than 300 mBq/L and were thus monitored for almost two years in order to screen possible seasonal variations. Further water samples were collected from spring captures, creeks and drainage pipes. The pipes drain the farmland north of Mont Vully showing 238U concentrations with more than 600 mBq/L. In order to discover the reason for the duplication in concentration, gamma dose rate measurements were accomplished on the farmland, revealing elevated dose rates of up to 160 nSv/h. These are located above ancient pathways of creeks that originated from Mont Vully. At these locations with elevated dose rates, three shallow sediment drill cores were taken and analyzed for their U content. The sediment cores can essentially be divided into three parts: (i) an upper soil with common U concentrations of about 30 Bq/kg 238U, (ii) an U-rich peat horizon with concentrations of up to 500 Bq/kg 238U, and (iii) an impermeable clay unit that acts as an aquitard with again minor 238U concentrations. Radiocarbon dating of the U-rich peat horizon reveals ages younger than 8.1 kyrs. This study suggests that a wetland was formed on top of the impermeable clay layer after the last glaciation during the Holocene. The stream waters with 238U concentrations of more than 300 mBq/L originating from Mont Vully contributed significantly to the water supply for the development of the wetland. Due to the reducing conditions that are present in wetlands, the dissolved U in the incoming streams was reduced and adsorbed onto organic matter. Accordingly, an entrapment for U was generated, persisting for at least 6 kyrs - a sufficient time to accumulate up to 500 Bq/kg. In the course of the last century, numerous wetlands in Switzerland were drained by capturing streams and installing drainage pipes to make the land suitable for agriculture. This kind of melioration was also done at the wetlands north of Mont Vully resulting in a subsequent change in redox conditions within the soil. The solubility of U depends on its oxidation state and U can be oxidized by oxygen-rich rainwater. The rainwater leached the U adsorbed on the peat yielding 238U concentrations of more than 600 mBq/L. Consequently, the duplication of 238U concentrations in the drainage water as compared to the original concentration that creeks brought into the ancient wetlands has been clarified during this study. Twenty of the analyzed public fountains in the Swiss Plateau exhibited a 238U concentration of more than 50 mBq/L. All of them could have contributed to the formation of a wetland after the last glaciation, which leads to the assumption that the situation at Mont Vully is not a singularity in the Swiss Plateau.


Asunto(s)
Monitoreo de Radiación , Contaminantes Radiactivos/análisis , Agricultura , Suelo , Suiza , Humedales
13.
Phys Chem Chem Phys ; 21(13): 7147-7154, 2019 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-30887992

RESUMEN

A gas-phase chemical study of rhenium carbonyls was carried out using short-lived radioisotopes produced at a heavy-ion accelerator. The Re isotopes produced in the nuclear reactions of natGd(23Na,xn)172-177Re were pre-separated with a gas-filled recoil ion separator and their carbonyls were synthesized in a mixture of inert gas and carbon monoxide. Using a low temperature isothermal chromatography apparatus, the adsorption enthalpies of Re carbonyls were derived to be ΔHads = -42 ± 2 kJ mol-1 on a Teflon® surface by fitting the external chromatograms with a Monte Carlo simulation program. A chemical yield of 25% relative to that of the transport yield for Re by a He/KCl gas-jet was achieved. The laser-ablation time-of-flight mass-spectrometric technique was employed to identify the species of Re carbonyls produced in the gas phase. The most stable species was deduced to be Re(CO)5 based on the mass-spectrometric analysis as well as quantum chemistry calculations.

14.
Chimia (Aarau) ; 73(3): 173-178, 2019 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-30890212

RESUMEN

One hundred and fifty years after its conception the periodic table of the elements contains 118 members with the 7th period being completely filled. This raises the question of what are the natural limits of the periodic table and whether yet undiscovered elements can be synthesized. Nowadays the alchemists' dream of producing new elements from already known ones has become reality. However, only single, short-lived atoms can be produced and investigated. The current article will give insights into the state of the art concerning the synthesis and chemical investigation of heavy and superheavy elements and discuss limits to the further expansion of the periodic table to even heavier elements in the 8th period.

15.
Appl Radiat Isot ; 145: 205-208, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30641434

RESUMEN

43,44Sc/47Sc is one of the most promising theranostic pairs in nuclear medicine. The co-emission of 1157 keV γ-rays with 99.9% branching ratio by 44Sc and the presence of its metastable state 44 mSc push to favour the adoption of 43Sc for Positron Emission Tomography (PET) diagnostic procedures to lighten the dose to the patient and to the personnel. The ß+ emitter 43Sc can be produced at a medical cyclotron by proton bombardment of an enriched 43Ca or 46Ti oxide target. 43Sc can be also produced by deuteron bombardment of an enriched 42Ca oxide target. Only a few medical cyclotrons currently in operation offer deuteron beams. Some can be adapted to operate both a proton or a deuteron source. To compare these three production routes, an accurate knowledge of the cross-sections is essential. In this paper, we report on the cross-section measurement of the reaction 42Ca(d,n)43Sc performed at the 6 MV HVEC EN-Tandem of the Ion Beam Physics group at ETH in Zürich. A study of the production yield by using commercially available enriched target materials is also presented.


Asunto(s)
Marcaje Isotópico/métodos , Radioisótopos/aislamiento & purificación , Escandio/aislamiento & purificación , Radioisótopos de Calcio/química , Ciclotrones , Deuterio , Humanos , Tomografía de Emisión de Positrones , Protones , Radiofármacos/aislamiento & purificación , Nanomedicina Teranóstica
16.
Pharmaceuticals (Basel) ; 11(4)2018 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-30487460

RESUMEN

Girentuximab (cG250) targets carbonic anhydrase IX (CAIX), a protein which is expressed on the surface of most renal cancer cells (RCCs). cG250 labeled with 177Lu has been used in clinical trials for radioimmunotherapy (RIT) of RCCs. In this work, an extensive characterization of the immunoconjugates allowed optimization of the labeling conditions with 177Lu while maintaining immunoreactivity of cG250, which was then investigated in in vitro and in vivo experiments. cG250 was conjugated with S-2-(4-isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane tetraacetic acid (DOTA(SCN)) by using incubation times between 30 and 90 min and characterized by mass spectrometry. Immunoconjugates with five to ten DOTA(SCN) molecules per cG250 molecule were obtained. Conjugates with ratios less than six DOTA(SCN)/cG250 had higher in vitro antigen affinity, both pre- and postlabeling with 177Lu. Radiochemical stability increased, in the presence of sodium ascorbate, which prevents radiolysis. The immunoreactivity of the radiolabeled cG250 tested by specific binding to SK-RC-52 cells decreased when the DOTA content per conjugate increased. The in vivo tumor uptake was < 10% ID/g and independent of the total amount of protein in the range between 5 and 100 µg cG250 per animal. Low tumor uptake was found to be due to significant necrotic areas and heterogeneous CAIX expression. In addition, low vascularity indicated relatively poor accessibility of the CAIX target.

17.
Surg Endosc ; 32(12): 5021-5030, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30324463

RESUMEN

BACKGROUND: Complete mesocolic excision is gradually becoming an established oncologic surgical principle for right hemicolectomy. However, the procedure is technically demanding and carries the risk of serious complications, especially when performed laparoscopically. A standardized procedure that minimizes technical hazards and facilitates teaching is, therefore, highly desirable. METHODS: An expert group of surgeons and one anatomist met three times. The initial aim was to achieve consensus about the surgical anatomy before agreeing on a sequence for dissection in laparoscopic CME. This proposal was evaluated and discussed in an anatomy workshop using post-mortem body donors along with videos of process-informed procedures, leading to a definite consensus. RESULTS: In order to provide a clear picture of the surgical anatomy, the "open book" model was developed, consisting of symbolic pages representing the corresponding dissection planes (retroperitoneal, ileocolic, transverse mesocolic, and mesogastric), vascular relations, and radicality criteria. The description of the procedure is based on eight preparative milestones, which all serve as critical views of safety. The chosen sequence of the milestones was designed to maximize control during central vascular dissection. Failure to reach any of the critical views should alert the surgeon to a possible incorrect dissection and to consider converting to an open procedure. CONCLUSION: Combining the open-book anatomical model with a clearly structured dissection sequence, using critical views as safety checkpoints, may provide a safe and efficient platform for teaching laparoscopic right hemicolectomy with CME.


Asunto(s)
Anatomía Regional , Colectomía , Colon Ascendente , Neoplasias del Colon/cirugía , Laparoscopía , Complicaciones Posoperatorias , Colectomía/efectos adversos , Colectomía/métodos , Colectomía/normas , Colon Ascendente/anatomía & histología , Colon Ascendente/cirugía , Alemania , Humanos , Laparoscopía/efectos adversos , Laparoscopía/métodos , Laparoscopía/normas , Modelos Anatómicos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Mejoramiento de la Calidad , Estándares de Referencia
18.
Eur J Surg Oncol ; 44(4): 469-483, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29422252

RESUMEN

AIM: To investigate the rate of laparoscopic colectomies for colon cancer using registries and population-based studies. To provide a position paper on mini-invasive (MIS) colon cancer surgery based on the opinion of experts leader in this field. METHODS: A systematic review of the literature was conducted using PRISMA guidelines for the rate of laparoscopy in colon cancer. Moreover, Delphi methodology was used to reach consensus among 35 international experts in four study rounds. Consensus was defined as an agreement ≥75.0%. Domains of interest included nosology, essential technical/oncological requirements, outcomes and MIS training. RESULTS: Forty-four studies from 42 articles were reviewed. Although it is still sub-optimal, the rate of MIS for colon cancer increased over the years and it is currently >50% in Korea, Netherlands, UK and Australia. The remaining European countries are un-investigated and presented lower rates with highest variations, ranging 7-35%. Using Delphi methodology, a laparoscopic colectomy was defined as a "colon resection performed using key-hole surgery independently from the type of anastomosis". The panel defined also the oncological requirements recognized essential for the procedure and agreed that when performed by experienced surgeons, it should be marked as best practice in guidelines, given the principles of oncologic surgery be respected (R0 procedure, vessel ligation and mesocolon integrity). CONCLUSION: The rate of MIS colectomies for cancer in Europe should be further investigated. A panel of leaders in this field defined laparoscopic colectomy as a best practice procedure when performed by an experienced surgeon respecting the standards of surgical oncology.


Asunto(s)
Colectomía/normas , Neoplasias del Colon/cirugía , Técnica Delphi , Laparoscopía/normas , Garantía de la Calidad de Atención de Salud , Humanos
19.
Oncotarget ; 8(55): 94681-94691, 2017 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-29212258

RESUMEN

[99mTc]Tc-Sestamibi (MIBI) is an increasingly used tool for evaluation of thyroid nodules. However, there is a lack of evidence about the accuracy of this method in the European population. The aim of this study was to assess the utility of MIBI for the differentiation of thyroid nodules in a large cohort. 161 patients underwent MIBI, followed by a thyroidectomy. We used a dual phase MIBI protocol. Interpretation of the images included a scoring system from 0 (absent) to 3 (increased); this was to provide a scale for the uptake of the thyroid nodule in comparison to the paranodular tissue. Additionally, we evaluated the tracer uptake trend in late images compared to early images. We used the final histopathology as the reference standard. Scores 0-1 in early images, scores 0-2 in late images, and an absence of increasing uptake in the thyroid nodule in late images, showed the best predictive values to exclude malignancy, respectively (negative predictive value (NPV) 89%). Highest sensitivity (91%) for malignant nodules was evident in early images with a score 1-3. Highest specificity (91%) was obtained when the negative was defined as an absence of uptake-increase, in the late images. This study confirms that the most valuable feature of MIBI is the high NPV. Thus, with the appropriate interpretation method, high sensitivity and specificity, and moderate PPV can be obtained.

20.
Appl Radiat Isot ; 129: 96-102, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28830022

RESUMEN

43Sc and 44Sc are positron emitter radionuclides that, in conjunction with the ß- emitter 47Sc, represent one of the most promising possibilities for theranostics in nuclear medicine. Their availability in suitable quantity and quality for medical applications is an open issue and their production with medical cyclotrons represents a scientific and technological challenge. For this purpose, an accurate knowledge of the production cross sections is mandatory. In this paper, we report on the cross section measurement of the reactions 43Ca(p,n)43Sc, 44Ca(p,2n) 43Sc, 46Ti(p,α)43Sc, and 44Ca(p,n)44Sc at the Bern University Hospital cyclotron. A study of the production yield and purity performed by using commercially available enriched target materials is also presented.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA