RESUMEN
Sequence verification of plasmid DNA is critical for many cloning and molecular biology workflows. To leverage high-throughput sequencing, several methods have been developed that add a unique DNA barcode to individual samples prior to pooling and sequencing. However, these methods require an individual plasmid extraction and/or in vitro barcoding reaction for each sample processed, limiting throughput and adding cost. Here, we develop an arrayed in vivo plasmid barcoding platform that enables pooled plasmid extraction and library preparation for Oxford Nanopore sequencing. This method has a high accuracy and recovery rate, and greatly increases throughput and reduces cost relative to other plasmid barcoding methods or Sanger sequencing. We use in vivo barcoding to sequence verify >45 000 plasmids and show that the method can be used to transform error-containing dispersed plasmid pools into sequence-perfect arrays or well-balanced pools. In vivo barcoding does not require any specialized equipment beyond a low-overhead Oxford Nanopore sequencer, enabling most labs to flexibly process hundreds to thousands of plasmids in parallel.
Asunto(s)
Biblioteca de Genes , Secuenciación de Nucleótidos de Alto Rendimiento , Plásmidos , Plásmidos/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Análisis de Secuencia de ADN/métodos , ADN/genética , Código de Barras del ADN Taxonómico/métodos , Secuenciación de Nanoporos/métodosRESUMEN
Sequence verification of plasmid DNA is critical for many cloning and molecular biology workflows. To leverage high-throughput sequencing, several methods have been developed that add a unique DNA barcode to individual samples prior to pooling and sequencing. However, these methods require an individual plasmid extraction and/or in vitro barcoding reaction for each sample processed, limiting throughput and adding cost. Here, we develop an arrayed in vivo plasmid barcoding platform that enables pooled plasmid extraction and library preparation for Oxford Nanopore sequencing. This method has a high accuracy and recovery rate, and greatly increases throughput and reduces cost relative to other plasmid barcoding methods or Sanger sequencing. We use in vivo barcoding to sequence verify >45,000 plasmids and show that the method can be used to transform error-containing dispersed plasmid pools into sequence-perfect arrays or well-balanced pools. In vivo barcoding does not require any specialized equipment beyond a low-overhead Oxford Nanopore sequencer, enabling most labs to flexibly process hundreds to thousands of plasmids in parallel.
RESUMEN
This study evaluates the capacity of commercial formulations of synthetic fungicides to inhibit grapevine bacterial growth when sprayed on vineyards to control diseases, such as downy mildew, powdery mildew and secondary rots. Fungicide sensitivity plate assays were carried out on bacteria isolated from vineyards that were also identified and characterized for their plant growth-promoting (PGP) traits and antifungal activity. The high taxonomic variability of bacteria screened with different chemical classes of fungicides is one new finding of this study. Seven out of 11 fungicides were able to inhibit the growth of bacteria at a concentration corresponding to the maximum dose allowed by law in spray treatments of vineyards. Bacterial sensitivity to each fungicide varied greatly. Many sensitive isolates displayed PGP traits and/or antagonistic activity. This study shows the potential impact of fungicidal treatments on grapevine bacterial microbiota. The involvement of bacteria beneficial to the growth and health of plants underlines the importance of this investigation. Our data reveal that the control of a certain disease may be possible using fungicides that have no or low impact on natural non-target microbiota. Understanding the action mechanisms of the active ingredients in these products is a priority for the development of new eco-friendly pesticides.
Asunto(s)
Fungicidas Industriales , Oomicetos , Vitis , Fungicidas Industriales/farmacología , Vitis/microbiología , Enfermedades de las Plantas/prevención & control , Enfermedades de las Plantas/microbiología , BacteriasRESUMEN
Pathogenic autoreactive antibodies that may be associated with life-threatening coronavirus disease 2019 (COVID-19) remain to be identified. Here, we show that self-assembled genome-scale libraries of full-length proteins covalently coupled to unique DNA barcodes for analysis by sequencing can be used for the unbiased identification of autoreactive antibodies in plasma samples. By screening 11,076 DNA-barcoded proteins expressed from a sequence-verified human ORFeome library, the method, which we named MIPSA (for Molecular Indexing of Proteins by Self-Assembly), allowed us to detect circulating neutralizing type-I and type-III interferon (IFN) autoantibodies in five plasma samples from 55 patients with life-threatening COVID-19. In addition to identifying neutralizing type-I IFN-α and IFN-ω autoantibodies and other previously known autoreactive antibodies in patient plasma, MIPSA enabled the detection of as yet unidentified neutralizing type-III anti-IFN-λ3 autoantibodies that were not seen in healthy plasma samples or in convalescent plasma from ten non-hospitalized individuals with COVID-19. The low cost and simple workflow of MIPSA will facilitate unbiased high-throughput analyses of protein-antibody, protein-protein and protein-small-molecule interactions.
Asunto(s)
Autoanticuerpos , COVID-19 , COVID-19/terapia , Biblioteca de Genes , Humanos , Inmunización Pasiva , Interferón-alfa , Sueroterapia para COVID-19RESUMEN
In the attempt to bridge the widening gap from DNA sequence to biological function, we developed a novel methodology to assemble Long-Adapter Single-Strand Oligonucleotide (LASSO) probe libraries that enabled the massively multiplexed capture of kilobase-sized DNA fragments for downstream long read DNA sequencing or expression. This method uses short DNA oligonucleotides (pre-LASSO probes) and a plasmid vector that supplies the linker sequence for the mature LASSO probe through Cre-LoxP intramolecular recombination. This strategy generates high quality LASSO probes libraries (≈46% of correct probes). We performed NGS analysis of the post-capture PCR amplification of DNA circles obtained from the LASSO capture of 3087 Escherichia coli ORFs spanning from 400- to 5000 bp. The median enrichment of all targeted ORFs versus untargeted ORFs was 30 times. For ORFs up to 1kb in size, targeted ORFs were enriched up to a median of 260-fold. Here, we show that LASSO probes obtained in this manner, were able to capture full-length open reading frames from total human cDNA. Furthermore, we show that the LASSO capture specificity and sensitivity is sufficient for target capture from total human genomic DNA template. This technology can be used for the preparation of long-read sequencing libraries and for massively multiplexed cloning of human sequences.
Asunto(s)
Oligonucleótidos , Recombinasas , ADN , Sondas de ADN , Humanos , Sondas de Oligonucleótidos , Análisis de Secuencia de ADNRESUMEN
Genome DNA sequencing has become an affordable means to resolve questions about the genetic background of life. However, the biological functions of many DNA-encoded sequences are still relatively unknown. A highly scalable and cost-effective cloning method to select natural DNA targets from genomic templates is therefore urgently needed to enable rapid understanding of the biological products of genomes. One such method involves LASSO probes, which are long single-stranded DNA oligonucleotides designed with a universal adapter that is used to link two sequences that are complementary to a genomic target of interest. Through a pooled assembly method, LASSOs can be made for multiplex DNA capture. Herein, we describe a robust, efficient method to assemble LASSO probe libraries using a Cre-recombinase-mediated reaction and a protocol for multiplex genome target capture. The starting components are a pre-LASSO probe library comprising short DNA oligo pools designed in silico and an Escherichia coli plasmid (pLASSO) that incorporates the pre-LASSO library. Through internal recombination of pLASSO with its inserts, a mature LASSO library in final configuration can be made with high purity. Assembly of a LASSO probe library takes 4 days, and target capture can be performed in a single day. With an exponentially growing list of new genomes available for investigation, this method can enable the rapid production of ORFeome libraries for high-throughput screening to identify biological functions as a complementary approach to understand genome functional biology. © 2021 Wiley Periodicals LLC. Basic Protocol 1: Assembly of LASSO probes Support Protocol 1: Generation of pLASSO vectors Support Protocol 2: Preparation of pre-LASSOs Basic Protocol 2: Massively parallel capture of large DNAs using LASSO probes.
Asunto(s)
ADN , Oligonucleótidos , Biblioteca de Genes , Sondas de Oligonucleótidos , Oligonucleótidos/genética , Análisis de Secuencia de ADNRESUMEN
Unbiased antibody profiling can identify the targets of an immune reaction. A number of likely pathogenic autoreactive antibodies have been associated with life-threatening SARS-CoV-2 infection; yet, many additional autoantibodies likely remain unknown. Here we present Molecular Indexing of Proteins by Self Assembly (MIPSA), a technique that produces ORFeome-scale libraries of proteins covalently coupled to uniquely identifying DNA barcodes for analysis by sequencing. We used MIPSA to profile circulating autoantibodies from 55 patients with severe COVID-19 against 11,076 DNA-barcoded proteins of the human ORFeome library. MIPSA identified previously known autoreactivities, and also detected undescribed neutralizing interferon lambda 3 (IFN-λ3) autoantibodies. At-risk individuals with anti- IFN-λ3 antibodies may benefit from interferon supplementation therapies, such as those currently undergoing clinical evaluation.
RESUMEN
BACKGROUND: Long Adapter Single-Stranded Oligonucleotide (LASSO) probes were developed as a novel tool for massively parallel cloning of kilobase-long genomic DNA sequences. LASSO dramatically improves the capture length limit of current DNA padlock probe technology from approximately 150 bps to several kbps. High-throughput LASSO capture involves the parallel assembly of thousands of probes. However, malformed probes are indiscernible from properly formed probes using gel electrophoretic techniques. Therefore, we used next-generation sequencing (NGS) to assess the efficiency of LASSO probe assembly and how it relates to the nature of DNA capture and amplification. Additionally, we introduce a simplified single target LASSO protocol using classic molecular biology techniques for qualitative and quantitative assessment of probe specificity. RESULTS: A LASSO probe library targeting 3164 unique E. coli ORFs was assembled using two different probe assembly reaction conditions with a 40-fold difference in DNA concentration. Unique probe sequences are located within the first 50 bps of the 5' and 3' ends, therefore we used paired-end NGS to assess probe library quality. Properly mapped read pairs, representing correctly formed probes, accounted for 10.81 and 0.65% of total reads, corresponding to ~ 80% and ~ 20% coverage of the total probe library for the lower and higher DNA concentration conditions, respectively. Subsequently, we used single-end NGS to correlate probe assembly efficiency and capture quality. Significant enrichment of LASSO targets over non-targets was only observed for captures done using probes assembled with a lower DNA concentration. Additionally, semi-quantitative polyacrylamide gel electrophoresis revealed a ~ 10-fold signal-to-noise ratio of LASSO capture in a simplified system. CONCLUSIONS: These results suggest that LASSO probe coverage for target sequences is more predictive of successful capture than probe assembly depth-enrichment. Concomitantly, these results demonstrate that DNA concentration at a critical step in the probe assembly reaction significantly impacts probe formation. Additionally, we show that a simplified LASSO capture protocol coupled to PAGE (polyacrylamide gel electrophoresis) is highly specific and more amenable to small-scale LASSO approaches, such as screening novel probes and templates.
Asunto(s)
Clonación Molecular/métodos , Sondas de ADN/genética , ADN de Cadena Simple/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Oligonucleótidos/genética , ADN/análisis , ADN/genética , Cartilla de ADN/genética , Electroforesis en Gel de Poliacrilamida/métodos , Proteínas de Escherichia coli/genética , Amplificación de Genes , Biblioteca de Genes , Sistemas de Lectura Abierta/genética , Reacción en Cadena de la Polimerasa/métodos , Reproducibilidad de los ResultadosRESUMEN
Multiplexed cloning of long DNA sequences is a valuable technique in many biotechnology applications, such as long-read genome sequencing and the creation of open reading frame (ORF) libraries. Long-adapter single-stranded oligonucleotide (LASSO) probes have shown promise as a tool to clone long DNA fragments. LASSO probes are molecular inversion probes (MIP) engineered with an adapter region of user-defined length, flanked between template-specific probe sequences. Herein, we demonstrate that the adapter length is a key feature of LASSO that influences the efficiency of gene capture and cloning. Furthermore, we applied a model based on Monte Carlo molecular simulation in order to study the relationship between the long-adapter length of LASSO and capture enrichment. Our results suggest that the adapter length is a factor that contributes to the free energy of target-probe interaction, thereby determining the efficiency of capture. The results indicate that LASSOs with extremely long adapters cannot capture the targets well. They also suggest that targets of different lengths may prefer adapters of different lengths.
Asunto(s)
Clonación Molecular/métodos , Programas Informáticos , ADN/química , Método de Montecarlo , Oligodesoxirribonucleótidos/química , Oligodesoxirribonucleótidos/normas , Análisis de Secuencia de ADN/métodos , TermodinámicaRESUMEN
As the catalogue of sequenced genomes and metagenomes continues to grow, massively parallel approaches for the comprehensive and functional analysis of gene products and regulatory elements are becoming increasingly valuable. Current strategies to synthesize or clone complex libraries of DNA sequences are limited by the length of the DNA targets, throughput and cost. Here, we show that long-adapter single-strand oligonucleotide (LASSO) probes can capture and clone thousands of kilobase DNA fragments in a single reaction. As a proof-of-principle, we simultaneously cloned >3,000 bacterial open reading frames (ORFs) from E. coli genomic DNA (spanning 400-5,000 bp targets). Targets were enriched up to a median of ~60-fold compared to non-targeted genomic regions. At a cutoff of 3 times the median non-target reads per kilobase of genetic element per million reads, ~75% of the targeted ORFs were successfully captured. We also show that LASSO probes can clone human ORFs from complementary DNA, and an ORF library from a human-microbiome sample. LASSO probes could be used for the preparation of long-read sequencing libraries and for massively multiplexed cloning.
RESUMEN
Ampelomyces quisqualis is a mycoparasite of a diverse range of phytopathogenic fungi associated with the powdery mildew disease. Among them are several Erysiphaceae species with great economic impact on high-value crops such as grape. Due to its ability to parasitize and prevent the spread of powdery mildews, A. quisqualis has received considerable attention for its biocontrol potential. However, and in sharp contrast to the extensively studied biocontrol species belonging to the genus Trichoderma, little is known about the biology of A. quisqualis at the molecular and genetic levels. We present the first genome-wide transcription profiling in A. quisqualis during host-induced germination. A total of 1,536 putative genes showed significant changes in transcription during the germination of A. quisqualis. This finding denotes an extensive transcriptional reprogramming of A. quisqualis induced by the presence of the host. Several upregulated genes were predicted to encode for putative mycoparasitism-related proteins such as secreted proteases, virulence factors, and proteins related to toxin biosynthesis. Our data provide the most comprehensive sequence resource currently available for A. quisqualis in addition to offering valuable insights into the biology of A. quisqualis and its mycoparasitic lifestyle. Eventually, this may improve the biocontrol capacity of this mycoparasite.
Asunto(s)
Ascomicetos/genética , Enfermedades de las Plantas/prevención & control , Transcriptoma , Vitis/microbiología , Ascomicetos/fisiología , Agentes de Control Biológico , ADN Complementario/química , ADN Complementario/genética , Perfilación de la Expresión Génica , Biblioteca de Genes , Secuenciación de Nucleótidos de Alto Rendimiento , Análisis de Secuencia por Matrices de Oligonucleótidos , Filogenia , Enfermedades de las Plantas/microbiología , ARN de Hongos/genéticaRESUMEN
In a small-scale harmonization study involving nine laboratories in eight European countries, the intra- and interlaboratory performances of two commercially available systems, i.e., the VetMIC microplate system and Etest, for antimicrobial susceptibility testing of nonenterococcal lactic acid bacteria (NELAB) and bifidobacteria were analyzed. In addition, one laboratory also performed standard broth microdilution as a reference method. MICs of tetracycline, erythromycin, ampicillin, gentamicin, clindamycin, and streptomycin for the type strains of 25 species of NELAB and bifidobacteria and MICs of vancomycin for a selection of relevant taxa were determined. The previously described lactic acid bacterium susceptibility test medium (LSM) and related mixed-medium formulations, all including Iso-Sensitest broth as a basic component, were used as test media. The overall agreement of median MIC ranges +/- 1 log(2) dilution determined by the VetMIC and Etest methods with the median MICs determined by the reference method was very good for tetracycline, ampicillin, and streptomycin (92.3 to 100%) but low for erythromycin (19.5 to 30.7%) and clindamycin (50.0 to 80.8%). There was a consensus among the participating laboratories that VetMIC was preferred over Etest because of its lower cost, better growth support, and more uniform criteria for MIC end point reading. With the range for acceptable intralaboratory reproducibility being defined as the median MIC +/- 1 log(2) dilution, VetMIC results (with 69.2% of all data sets in the acceptable range) were shown to display greater reproducibility than Etest results (with 58.8% of all data sets in the acceptable range). Also at the interlaboratory level, the proportion of MIC values obtained with VetMIC that belonged to the complete agreement category (60.0%) was higher than the proportion of such values obtained with Etest (47.0%), which indicates a higher degree of interlaboratory reproducibility for the former method. Apart from some agent-specific effects, the majority of VetMIC and Etest replicate data sets were situated within a 1- to 2-log(2) dilution range, suggesting that the two methods can be considered to be equivalent for recognizing resistance phenotypes. This multicenter study has further validated the standard use of LSM and related mixed-medium formulations with commercially available systems and formed the basis for the ongoing development of the ISO 10932/IDF 223 standard for susceptibility testing of NELAB and bifidobacteria.
Asunto(s)
Bifidobacterium/efectos de los fármacos , Lactobacillus/efectos de los fármacos , Pruebas de Sensibilidad Microbiana/métodos , Enterococcus faecalis/efectos de los fármacos , Europa (Continente) , Microbiología de Alimentos , Laboratorios , Pruebas de Sensibilidad Microbiana/normas , Pruebas de Sensibilidad Microbiana/estadística & datos numéricos , Streptococcus thermophilus/efectos de los fármacosRESUMEN
A total of 74 Streptococcus thermophilus isolates collected between 1948 and 2005 from different environments were investigated to assess erythromycin, clindamycin, streptomycin, gentamicin, tetracycline and ampicillin susceptibility by means of microdilution, Etest and disk diffusion methods. For this purpose a new S. thermophilus Susceptibility test Medium (SSM) was developed. This medium allowed a better identification of strains with atypical tetracycline resistance. The recipe is a mixed formulation of Iso-Sensitest medium (90% v/v) and M17 medium (10% v/v) supplemented with lactose (0.5% w/v). The overall agreement of the techniques was good with exception of tetracycline, for which Etest provided lower MICs than the microdilution method. Most strains were susceptible to all the antibiotics tested while a few erythromycin, tetracycline and streptomycin resistant strains were detected.
Asunto(s)
Antibacterianos/farmacología , Streptococcus thermophilus/efectos de los fármacos , Ampicilina/farmacología , Clindamicina/farmacología , Enzimas de Restricción del ADN/metabolismo , ADN Bacteriano/genética , ADN Bacteriano/metabolismo , Farmacorresistencia Bacteriana/efectos de los fármacos , Eritromicina/farmacología , Gentamicinas/farmacología , Pruebas de Sensibilidad Microbiana/métodos , Streptococcus thermophilus/genética , Streptococcus thermophilus/crecimiento & desarrollo , Estreptomicina/farmacología , Tetraciclina/farmacología , Tetraciclinas/farmacologíaRESUMEN
The minimum inhibitory concentrations (MICs) of six antibiotics with activity against gram-positive bacteria (ampicillin, clindamycin, erythromycin, gentamicin, streptomycin, and tetracycline) were determined by microdilution and the Etest in 121 Lactobacillus plantarum strains of plant and dairy origin. MIC values for all antibiotics varied widely between strains. The analysis of both absolute MICs and their distribution was used to define new susceptibility-resistance cutoff values for all antibiotics, except for streptomycin. Based on these new cutoffs, the studied strains were nearly all identified as either susceptible (ampicillin, clindamycin, erythromycin, and gentamicin) or intrinsically resistant (streptomycin). The exceptions were four strains with MICs for tetracycline higher than the cutoff point (64 microg ml(1)); these were suspected to harbor acquired resistance determinants.