Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Rev. bras. cir. cardiovasc ; 37(5): 765-768, Sept.-Oct. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1407298

RESUMEN

ABSTRACT Transfemoral transcatheter aortic valve replacement (TAVR) is currently the standard catheter-based treatment of severe aortic stenosis patients. Being the transfemoral route not feasible, other access sites could be chosen. Transaortic TAVR via either a J mini-sternotomy or a right anterolateral mini-thoracotomy is a good option for patients having tricky thoracoabdominal aorta. Some tips and tricks may help in getting a fast and safe transaortic procedure.

2.
J Endovasc Ther ; : 15266028221118507, 2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-36000341

RESUMEN

PURPOSE: This study reports the outcomes from a Multicenter Registry on unibody stent-graft system for the treatment of spontaneous infrarenal acute aortic syndrome (MURUSSIAS registry). MATERIALS AND METHODS: The retrospective MURUSSIAS registry included spontaneous infrarenal acute aortic dissection (IAAS) managed with the unibody stent-graft system (AFX endovascular AAA system; Endologix Inc., Irvine, California) outside the current instruction for use. IAAS considered aortic dissection (AD), intramural hematoma (IMH), and penetrating aortic ulcer (PAU). Indications to IAAS treatment were symptoms, associated dilated abdominal aorta (>3 cm), rapidly-growing (>0.5 cm/6 months) aorta, IAAS disease progression. Measured results were technical success, early (within 30 days) and midterm outcomes (after 30 days), including mortality, complications, symptoms recurrence, type I/III endoleak occurrence, stent-graft patency, survival, and freedom from reintervention. The mean follow-up was 22.12 ± 17 months. RESULTS: The MURUSSIAS registry included 83 patients from 7 participating centers. IAAS indication to treatment were symptoms in 42 (51%). In 14 (17%) patients, the infrarenal aortic length was <80 mm, and in 28 (34%), the aortic bifurcation diameter was <16 mm. Technical success was 100%. Mortality occurred early in 1 (1%) and at the midterm in 3 (4%) patients. Complications occurred early in 10 (12%) patients (1 severe, 3 moderates, and 6 mild) and at midterm in 2 (2%) (2 moderate). No symptoms' recurrence or type I/III endoleaks were registered. The 36-month estimated survival and freedom from reinterventions were 89% and 92%, respectively. CONCLUSIONS: The MURUSSIAS registry is the largest collection of spontaneous IAAS managed endovascularly using the AFX endovascular AAA system. The IAAS peculiar anatomic features were fitted with the used technique with excellent results. This treatment strategy might be considered in IAAS unless specifically-designed endovascular solutions will be available also in the emergent setting. Further studies are required to assess the longer-term performances and the stability of the reported technique. CLINICAL IMPACT: The lack of specifically designed devices for infrarenal acute aortic syndrome (IAAS) disease remains an issue principally for its specific anatomic features. The MURUSSIAS registry retrospectively examined the outcomes of spontaneous IAAS treated using the unibody stent-graft system in a spontaneous national study; and reports the largest available data on this topic. The use of the unibody stent-graft system showed to fit the anatomic peculiarities of IAAS with excellent outcomes. This IAAS treatment strategy should be considered unless specifically designed endovascular solutions will be available.

3.
Braz J Cardiovasc Surg ; 37(5): 765-768, 2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-35895988

RESUMEN

Transfemoral transcatheter aortic valve replacement (TAVR) is currently the standard catheter-based treatment of severe aortic stenosis patients. Being the transfemoral route not feasible, other access sites could be chosen. Transaortic TAVR via either a J mini-sternotomy or a right anterolateral mini-thoracotomy is a good option for patients having tricky thoracoabdominal aorta. Some tips and tricks may help in getting a fast and safe transaortic procedure.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Esternotomía , Toracotomía , Válvula Aórtica/cirugía , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/métodos
4.
J Card Surg ; 37(7): 1887-1893, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35249231

RESUMEN

AIMS: In the clinical practice a noteworthy proportion of severe symptomatic aortic stenosis patients presents with low-flow low-gradients features, these having reported a less favorable prognosis even when surgically or transcatheter treated. METHODS AND RESULTS: We retrospectively analyzed the prospectively collected data on 1051 consecutive patients undergone balloon-expandable transcatheter aortic valve replacement at our Institution from January 2008 to January 2020. We divided the population according with a mean aortic gradient (MAG) < or ≥40 mmHg and we performed a propensity-matched analysis based on the Society of Thoracic Surgery Score and age, obtaining two homogeneous groups of 314 patients each (Groups A and B, respectively). We then analyzed the outcomes of the two groups by implementing adjusted Cox models adjusted for significant clinical differences between the two groups, such as sex, ejection fraction, comorbidities and other variables not included in the propensity-matched analysis. The only variable associated with both cardiovascular and all-cause events was an ejection fraction ≤35%. Finally, a sensitivity analysis found that an ejection fraction ≤35% was associated with an increase cardiovascular and all-cause mortality only in patients with an indexed end-diastolic volume >97 ml/m2 (p = .0438 and .3363, respectively). CONCLUSIONS: In our series a MAG <40 mmHg was not found to be per se an independent risk factor for cardiac and all-cause mortality after transcatheter aortic valve replacement. The ejection fraction was found to be an independent risk factor only in the context of enlarged left ventricular dimensions.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Humanos , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Función Ventricular Izquierda
5.
Front Cardiovasc Med ; 8: 653991, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34124193

RESUMEN

Background: A strong association between aortic valve sclerosis (AVSc), the earliest manifestation of calcific aortic valve disease, and atherosclerosis exists. The aim of the study was to evaluate the predictive capabilities of AVSc on long-term all-cause mortality, in patients requiring carotid endarterectomy (CEA). Methods and Results: 806 consecutive CEA patients were enrolled. Preoperative echocardiography was used to assess AVSc. Computed tomography angiography was applied for plaque characterization. Kaplan-Meier curves, Cox linear regression, and area under the receiving operator characteristic (AUC) curve analyses were used to evaluate the predictive capability of AVSc. Overall, 348 of 541 patients had AVSc (64%). Age, diabetes, and estimated glomerular filtration rate (eGFR) were associated with AVSc. In the 5-year follow-up, AVSc group had a mortality rate of 16.7% while in no-AVSc group was 7.8%. Independent predictors of all-cause mortality were age, sex, eGFR, left ventricular ejection fraction, and AVSc. After adjustments, AVSc was associated with a significant increase in all-cause mortality risk (hazard ratio, HR = 1.9; 95%CI: 1.04-3.54; p = 0.038). We stratify our cohort based on carotid atheromatous plaque-type: soft, calcified, and mixed-fibrotic. In patients with mixed-fibrotic plaques, the mortality rate of AVSc patients was 15.5% compared to 2.4% in no-AVSc patients. In this group, AVSc was associated with an increased long-term all-cause mortality risk with an adjusted HR of 12.8 (95%CI: 1.71-96.35; p = 0.013), and the AUC, combing eGFR and AVSc was 0.77 (p < 0.001). Conclusions: Our findings indicate that AVSc together with eGFR may be used to improve long-term risk stratification of patients undergoing CEA surgery.

6.
J Clin Med ; 10(5)2021 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-33669044

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an established technique to treat severe symptomatic aortic stenosis patients with a wide range of surgical risk. Currently, the common femoral artery is the first choice as the main access route for the procedure. The objective of this observational study is to report our experience on percutaneous and surgical cut-down transfemoral TAVRs comparing the two approaches. METHODS: From January 2014 to January 2019, five hundred eleven consecutive patients underwent TAVR for severe symptomatic aortic stenosis. We analyzed only elective transfemoral procedures. After propensity score-matching based on age, sex, EuroSCORE II, mean aortic gradient, and left ventricular ejection fraction, we obtained two homogeneous populations: surgical cut-down (n = 119) and percutaneous (n = 225), which were labeled Group 1 and Group 2, respectively. RESULTS: The main findings were that there were no significant procedural outcome differences between the two groups, but Group 2 patients had a shorter length of hospital stay and were more frequently discharged home. At follow-up, Group 1 patients had lower survival rates. CONCLUSIONS: An accurate preoperative assessment of the femoral access is mandatory to achieve satisfactory outcomes with transfemoral TAVRs. Nevertheless, the percutaneous approach allows shorter in-hospital stay and the need for rehabilitation, thus potentially decreasing the costs of the procedure.

7.
Eur J Vasc Endovasc Surg ; 61(2): 306-315, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33262093

RESUMEN

OBJECTIVE: During the most aggressive phase of the COVID-19 outbreak in Italy, the Regional Authority of Lombardy identified a number of hospitals, named Hubs, chosen to serve the whole region for highly specialised cases, including vascular surgery. This study reports the experience of the four Hubs for Vascular Surgery in Lombardy and provides a comparison of in hospital mortality and major adverse events (MAEs) according to COVID-19 testing. METHODS: Data from all patients who were referred to the Vascular Surgery Department of Hubs from 9 March to 28 April 2020 were collected prospectively and analysed. A positive COVID-19 polymerase chain reaction swab test, or symptoms (fever > 37.5 °C, upper respiratory tract symptoms, chest pain, and contact/travel history) associated with interstitial pneumonia on chest computed tomography scan were considered diagnostic of COVID-19 disease. Patient characteristics, operative variables, and in hospital outcomes were compared according to COVID-19 testing. A multivariable model was used to identify independent predictors of in hospital death and MAEs. RESULTS: Among 305 included patients, 64 (21%) tested positive for COVID-19 (COVID group) and 241 (79%) did not (non-COVID group). COVID patients presented more frequently with acute limb ischaemia than non-COVID patients (64% vs. 23%; p < .001) and had a significantly higher in hospital mortality (25% vs. 6%; p < .001). Clinical success, MAEs, re-interventions, and pulmonary and renal complications were significantly worse in COVID patients. Independent risk factors for in hospital death were COVID (OR 4.1), medical treatment (OR 7.2), and emergency setting (OR 13.6). COVID (OR 3.4), obesity class V (OR 13.5), and emergency setting (OR 4.0) were independent risk factors for development of MAEs. CONCLUSION: During the COVID-19 pandemic in Lombardy, acute limb ischaemia was the most frequent vascular disease requiring surgical treatment. COVID-19 was associated with a fourfold increased risk of death and a threefold increased risk of major adverse events.


Asunto(s)
COVID-19 , Control de Infecciones , Complicaciones Posoperatorias , Enfermedades Vasculares , Procedimientos Quirúrgicos Vasculares , Anciano , COVID-19/diagnóstico , COVID-19/epidemiología , COVID-19/prevención & control , Prueba de COVID-19/métodos , Prueba de COVID-19/estadística & datos numéricos , Urgencias Médicas/epidemiología , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Mortalidad Hospitalaria , Humanos , Control de Infecciones/métodos , Control de Infecciones/organización & administración , Italia/epidemiología , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Pronóstico , Estudios Retrospectivos , Ajuste de Riesgo/métodos , Factores de Riesgo , SARS-CoV-2/aislamiento & purificación , Enfermedades Vasculares/diagnóstico , Enfermedades Vasculares/mortalidad , Enfermedades Vasculares/cirugía , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/métodos
8.
J Card Surg ; 35(8): 2089-2092, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32652613

RESUMEN

Multiple valve replacements are known to carry additional risk of morbidity and mortality in redo context. Currently, a transcatheter-based valve-in-valve approach could be useful in reducing potential serious consequences. On the other hand, this approach poses several technical challenges regarding the device and the procedural aspects. We present the case of a 78-year-old man who presented with symptoms of heart failure due to mitral and aortic bioprosthesis degenerations who was deemed to be at extremely high risk for a conventional redo surgery. A two-step transcatheter-based approach was planned and a transfemoral aortic valve-in-valve procedure was followed by a transapical mitral valve-in-valve implantation with a favorable early and long-term outcome.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Estenosis de la Válvula Aórtica/cirugía , Humanos , Masculino , Estenosis de la Válvula Mitral/cirugía , Grupo de Atención al Paciente , Reoperación , Volumen Sistólico , Resultado del Tratamiento
9.
Eur J Cardiothorac Surg ; 58(2): 319-327, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32584978

RESUMEN

OBJECTIVES: During the Severe Acute Respiratory Syndrome-Coronavirus-2 (SARS-CoV-2) pandemic, Northern Italy had to completely reorganize its hospital activity. In Lombardy, the hub-and-spoke system was introduced to guarantee emergency and urgent cardiovascular surgery, whereas most hospitals were dedicated to patients with coronavirus disease 2019 (COVID-19). The aim of this study was to analyse the results of the hub-and-spoke organization system. METHODS: Centro Cardiologico Monzino (Monzino) became one of the four hubs for cardiovascular surgery, with a total of eight spokes. SARS-CoV-2 screening became mandatory for all patients. New flow charts were designed to allow separated pathways based on infection status. A reorganization of spaces guaranteed COVID-19-free and COVID-19-dedicated areas. Patients were also classified into groups according to their pathological and clinical status: emergency, urgent and non-deferrable (ND). RESULTS: A total of 70 patients were referred to the Monzino hub-and-spoke network. We performed 41 operations, 28 (68.3%) of which were emergency/urgent and 13 of which were ND. The screening allowed the identification of COVID-19 (three patients, 7.3%) and non-COVID-19 patients (38 patients, 92.7%). The newly designed and shared protocols guaranteed that the cardiac patients would be divided into emergency, urgent and ND groups. The involvement of the telematic management heart team allowed constant updates and clinical discussions. CONCLUSIONS: The hub-and-spoke organization system efficiently safeguards access to heart and vascular surgical services for patients who require ND, urgent and emergency treatment. Further reorganization will be needed at the end of this pandemic when elective cases will again be scheduled, with a daily increase in the number of operations.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/epidemiología , Neumonía Viral/epidemiología , Cirugía Torácica/organización & administración , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/prevención & control , Urgencias Médicas , Reforma de la Atención de Salud/organización & administración , Prioridades en Salud , Humanos , Control de Infecciones/organización & administración , Colaboración Intersectorial , Italia/epidemiología , Pandemias/prevención & control , Neumonía Viral/diagnóstico , Neumonía Viral/prevención & control , SARS-CoV-2 , Servicio de Cirugía en Hospital/organización & administración , Procedimientos Quirúrgicos Torácicos/normas
10.
Int J Cardiol ; 299: 228-234, 2020 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-31353154

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is frequently associated with severe aortic stenosis, but its influence on outcomes after transcatheter aortic valve implantation (TAVI) remains controversial. This study sought to assess the baseline etiology and degree of MR in TAVI population, identify the predictors of MR changes and investigate the clinical and prognostic impact of baseline MR at mid and long-term follow-up. METHODS: We enrolled 572 consecutive patients who underwent TAVI. MR degree and etiology were evaluated by echocardiography at baseline and 1-year follow-up. Clinical outcomes were obtained up to 3-year follow-up. RESULTS: At baseline, 168 patients (29%) had moderate-to-severe MR (MR ≥ 2). Organic MR was more frequently associated with MR ≥ 2 (MR < 2: 20%, MR ≥ 2: 43%, p < 0.001). Relevant MR had improved more in functional MR (79%) compared to organic MR (50%, p = 0.001). At the multivariate analysis, the coexistence of coronary artery disease (p = 0.026), absence of atrial fibrillation (p = 0.038) and functional etiology (p = 0.025) were predictors of MR improvement after TAVI. Patients with baseline MR ≥ 2 had a higher mortality rate than those with MR < 2 at 1-year and 3-year follow-up. Moreover, a landmark analysis starting from 1-year to 3-year follow-up, demonstrated that organic MR was associated with an increased risk of mortality throughout 3-year follow-up compared with functional MR, irrespective of MR severity. CONCLUSIONS: Baseline MR ≥ 2 in TAVI patients was associated with early and late mortality rate. At 1-year, significant improvement in MR severity was observed mainly in patients with functional MR ≥ 2. Organic MR ≥ 2 had a negative impact on 3-year, but not 1-year, mortality rate.


Asunto(s)
Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Anciano , Anciano de 80 o más Años , Ecocardiografía/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
11.
Open J Cardiovasc Surg ; 11: 1179065219853582, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31210733

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is nowadays generally accepted as the treatment of choice for high- to intermediate-risk patients with severe aortic stenosis not suitable for the standard surgical replacement. Many vascular accesses have been described for the valve delivery, comprising the common iliac artery as the arterial site of access. METHODS: From September 2008 to June 2014, 440 patients underwent TAVR at our institution. We report a series of 12 patients that have undergone TAVR via a trans-iliac (TI) retroperitoneal surgical approach and also discuss its feasibility, security, and medium-term follow-up. RESULTS: The 30-day survival rate was 92%. Only 1 local vascular access major complication occurred requiring an iliac-femoral bypass grafting with a vascular graft. Two patients experienced transient neurological ischemic attack. At 3-year follow-up, all the 11 patients were alive and well and the echocardiographic evaluation revealed good function of the prosthesis. CONCLUSIONS: The TI route seems to be feasible with a low profile of local complications. It may be a reasonable access alternative to the femoral artery and to the trans-apical approach. A broader, prospective study is advisable to gain general consensus on this approach.

12.
Ann Vasc Surg ; 58: 180-189, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30684621

RESUMEN

BACKGROUND: To evaluate the early safety and clinical performance of the new low-profile RelayPro Thoracic Stent-Graft System in patients with thoracic aortic disease. METHODS: This was an international, prospective, single-arm study in patients diagnosed with thoracic aorta disease (aneurysm, pseudoaneurysm, dissection, penetrating atherosclerotic ulcer, or intramural hematoma) and treated with a RelayPro stent-graft (in bare stent and/or nonbare stent configurations). The primary endpoints were freedom from aneurysm or dissection-related mortality and stent-graft performance. RESULTS: A total of 31 patients were treated with the RelayPro thoracic stent-graft between 2014 and 2015 at 8 sites in Italy and Spain. Mean age was 72.1 (±10.2) years and 77% were male, 74% with hypertension, and 42% with a history of smoking. Twenty-four (77%) had aneurysms (fusiform in 46%, saccular in 42%, pseudoaneurysm in 12%); 5 (16%) had penetrating atherosclerotic ulcer; and 2 (6%) had chronic Type B dissection. Mean vascular access diameter was 9.1 mm (6-13 mm); 7 patients (23%) had vascular access of 7 mm or less. Technical success was 100% (primary, 90%; assisted primary, 10%). Freedom from aneurysm/dissection-related mortality through 30 days was 100%. Freedom from device-related major adverse events through 30 days was 94%. At 1 year, there was 1 (3%) type Ib and 1 (3%) type II endoleak, 1 (3%) nonaneurysm-related late death, and 1 (3%) secondary intervention (to correct type Ib endoleak). CONCLUSIONS: The RelayPro has a 3-4 French profile reduction to allow endovascular repair of thoracic aortic disease in patients with smaller anatomies. This study shows good initial stent-graft performance and a favorable early safety profile.


Asunto(s)
Aorta Torácica/cirugía , Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Adulto , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/mortalidad , Enfermedades de la Aorta/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Supervivencia sin Progresión , Estudios Prospectivos , Diseño de Prótesis , Reoperación , Medición de Riesgo , Factores de Riesgo , España , Factores de Tiempo
13.
J Cardiovasc Comput Tomogr ; 13(3): 41-47, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30639115

RESUMEN

OBJECTIVES: To assess evaluability and diagnostic accuracy of a low dose CT angiography (CTA) protocol for carotid arteries using latest Iterative Reconstruction (IR) algorithm in comparison with standard 100 kVp protocol using previous generation CT and IR. MATERIALS AND METHODS: 105 patients, referred for CTA of the carotid arteries were prospectively enrolled in our study and underwent CTA with 80 kVp and latest IR algorithm (group 1). Data were retrospectively compared with 100 consecutive patients with similar examination indications that had previously undergone CTA of carotid arteries with a standard 100 kVp protocol and a first generation IR algorithm (group 2). Image quality was evaluated with a 4-point Likert-scale. For each exam CT number, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) at level of common carotid artery (CCA), internal carotid artery (ICA) and at level of Circle of Willis and Effective Dose (ED) were evaluated. 62 Group 1 patients underwent a clinically indicated DSA and results were compared with CTA. RESULTS: No exams reported as not diagnostic. The overall mean CT number value of all arterial segments was above 450 HU in both groups. Significant lower noise, and higher SNR and CNR values were found in group 1 in comparison with group 2 despite the use of 80 kVp. In 62-group 1 patients studied by DSA, CTA showed in a segment-based analysis a sensitivity, negative predictive value and accuracy of 100%, 100% and 99% respectively. Mean ED in group 1 was 0.54 ±â€¯0.1 mSv with a dose reduction up to 86%. CONCLUSIONS: CTA for carotid arteries using latest IR algorithm allows to perform exams with submillisievert radiation exposure maintaining good image quality, overall evaluability and diagnostic accuracy.


Asunto(s)
Algoritmos , Arterias Carótidas/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Angiografía por Tomografía Computarizada/instrumentación , Tomografía Computarizada Multidetector/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador , Tomógrafos Computarizados por Rayos X , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Bases de Datos Factuales , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
14.
Eur Heart J Cardiovasc Imaging ; 19(4): 389-397, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28379513

RESUMEN

Aims: Scarce data are available on the long-term structural and functional changes of prosthetic valves after transcatheter aortic valve implantation (TAVI). The objective was to evaluate with echocardiography the long-term structural and functional changes of prosthetic valves after TAVI. Methods and results: Structural valve deterioration (SVD) was defined as leaflet thickening ≥3mm, presence of calcification and abnormal leaflet motion. Five-year echocardiographic follow-up was available in 96 out of 318 patients who underwent TAVI with a balloon-expandable device between April 2008 and December 2011. At 1-year follow-up, no patient showed SVD. At 5-year follow-up, SVD were observed in 29 (30%) patients who showed also a significant reduction of aortic valve area (AVA) together with an increase of mean and peak aortic pressure gradients at the latest echocardiography evaluation. Moreover, rate of central aortic valve regurgitation ≥2 was higher in SVD patients as compared to those without SVD, while there was no difference in terms of paravalvular regurgitation. Despite SVD, one patient only reached the criteria for severe stenosis and no reintervention was needed at 5-year follow-up. Variables independently associated with SVD were female sex, small body surface area, use of a 23 mm valve, and small AVA at pre-discharge echocardiogram. Conclusion: At 5-year follow-up, 30% of patients who underwent TAVI with a balloon-expandable valve showed initial SVD. However, SVD was not associated with severe stenosis in most of the patients and had no significant impact on and clinical outcome.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Italia , Masculino , Análisis Multivariante , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
15.
Thorac Cardiovasc Surg Rep ; 6(1): e37-e39, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29250479

RESUMEN

No consensus exists on the timing, safety, and efficacy of treating severe symptomatic aortic and carotid stenosis. In the older population and in the presence of multiple comorbidities that arise during the surgery, a less invasive transcatheter treatment may be the only reasonable option. We discuss this topic by analyzing a case of an 84-year-old man who underwent a combined single-stage transcatheter procedure.

16.
J Cardiovasc Surg (Torino) ; 58(4): 565-573, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25791358

RESUMEN

BACKGROUND: Prospective single-arm study, aimed at evaluating safety and effectiveness at 12 and 24 months of the paclitaxel-eluting nitinol stent (Zilver PTX), and focused in particular on the treatment of complex lesions and/or diabetic patients. METHODS: Between May 2010 and March 2012, 67 patients (78% males) were treated by Zilver PTX, because of stenosis or occlusions of the superficial femoral artery in one of two centers. The mean age of patients was 70.1±8 years. Thirty-two of 67 (48%) were diabetics, 14 (21%) active smokers and 11 (14.6%) had chronic renal failure (end stage renal disease). The average length of lesions was 104±60 mm. Occlusion was complete in 46.3% of cases, whereas severely calcified lesions were present in 30% of patients (18.8% in diabetics and 31.4% in non-diabetics). Twenty-six patients (39%) had type C or D lesions according to TASC 2. RESULTS: One hundred-two stents were used (1.7±0.9 per patients); median 1 (range 1-4). All patients had successful stent placement. Primary patency, evaluated by Kaplan-Meier method was 88±0.06% at 12 months, and 68±0.1% at 24 months. In particular, the difference between diabetics (D) and non-diabetics (non-D) was not significant (P=0.07, Log-Rank). Patients turned from 4.2±1.3 to 1.6±1.3 Rutherford class. There were 5 deaths due to systemic comorbidities. There also were 3 major amputations, all of them also in the D group. Among the other patients, differences between D and non-D patients were not significant in terms of wound healing, bipedal stay and spontaneous ambulation. The mean follow-up length was 28±5 months (range 24-36 months). There was only one patient who had fracture and stent migration (1.5%). In 13 diabetic patients, tibial PTA was also associated. Additional treatment was required in 6 D and 1 non-D. CONCLUSIONS: The use of Zilver PTX is safe and effective in the treatment of SFA lesions. In particular, both stent patency and functional results on the basis of both clinical and instrumental tools were similar in D and non-D, suggesting a particularly favorable activity of PTX in a subpopulation of diabetics. Further studies are required to confirm these results, which seem to be particularly promising in diabetic patients.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Angiopatías Diabéticas/cirugía , Stents Liberadores de Fármacos , Procedimientos Endovasculares/instrumentación , Arteria Femoral , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Anciano , Anciano de 80 o más Años , Aleaciones , Amputación Quirúrgica , Fármacos Cardiovasculares/efectos adversos , Angiopatías Diabéticas/diagnóstico por imagen , Angiopatías Diabéticas/mortalidad , Angiopatías Diabéticas/fisiopatología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Italia , Estimación de Kaplan-Meier , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/fisiopatología , Diseño de Prótesis , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
17.
Interact Cardiovasc Thorac Surg ; 24(1): 150-152, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27659152

RESUMEN

Different vascular accesses have been described for the delivery of a transcatheter aortic bioprosthesis. We report the use of the superficial femoral artery (SFA) as the arterial site of puncture with surgical cut-down. It may be a reasonable access alternative to the other classical routes, especially in the setting of either obese patients with elevated body mass index or in the presence of high femoral artery bifurcation. This route seems to be feasible with a low-profile risk.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Arteria Femoral , Humanos
20.
Eur J Cardiothorac Surg ; 42(2): 254-59; discussion 259-60, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22290886

RESUMEN

OBJECTIVES: Thoracic endovascular aneurysm repair (TEVAR) is an appealing alternative to the standard surgical approach, but requires rigorous radiological follow-up. The cumulative radiation exposure (RE) of patients undergoing TEVAR-including pre-operative workup, the procedure and subsequent follow-up computed tomography (CT) imaging-has not previously been investigated. METHODS: From August 2003 to February 2011, 48 patients underwent TEVAR at our institution. Mean age was 66 ± 11 years, with 10 patients (21%) aged <60 years. Forty-one (85%) patients were male; 7 (15%) had urgent/emergent operation; 21 (44%) had undergone previous aortic surgery. Mean aortic diameter was 7.3 ± 2.1 cm. Intra-operative screening time and RE were reviewed, and typical institutional thoracic CT scan RE was calculated (17.8 mSv). Life expectancy of an age- and sex-matched population was estimated to assess the cumulative RE from recurrent CT follow-up. RESULTS: The average screening time was 15.7 ± 11.4 min, with an RE of 11.3 ± 9 mSv. Obese patients had significantly higher RE during TEVAR (Pearson's coefficient = 0.388, P = 0.019). The RE dropped from 14.9 ± 9.4 mSv to 8.6 ± 7.9 mSv (P = 0.033) after a hybrid suite was established. Our institutional TEVAR protocol involves one pre-operative thoracoabdominal CT scan and three follow-up thoracic CT scans for the first year, with a yearly evaluation thereafter. The life expectancy of an age- and sex-matched population was 17 years. A patient adhering to our surveillance protocol would be subjected to an overall exposure of 89 mSv at 1 year and 161 mSv at 5 years, with a projected lifetime RE >350 mSv. CONCLUSIONS: A 2-year RE exceeding the threshold of 100 mSv with a life expectancy >15 years can be estimated to lead to a lifetime risk increase in radiation-induced leukaemia and solid-tumour cancer >2.7%. The risks of cumulative RE especially in younger and/or obese patients must be balanced with the expected morbidity and mortality reduction in TEVAR versus traditional open repair, and the anticipated benefits of recurrent radiographic imaging.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Procedimientos Endovasculares/efectos adversos , Tomografía Computarizada por Rayos X/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios/efectos adversos , Cuidados Preoperatorios/efectos adversos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/mortalidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA