Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Echocardiography ; 34(2): 290-295, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28168751

RESUMEN

BACKGROUND: Effect of pulmonary hypertension (PH) on right ventricular (RV) geometry constitutes an ideal target to assess both pulmonary artery pressure (PAP) and its physiological importance. In this study, we evaluated the diagnostic power of the basal segment of septomarginal trabeculation (SMT) in predicting the PH and RV hypertrophy by cardiovascular magnetic resonance (CMR) in patients with idiopathic pulmonary arterial hypertension (IPAH) and Eisenmenger's syndrome (ES). METHODS: Eleven patients with IPAH, seven patients with ES, and 20 healthy controls were enrolled. CMR was used to measure the area and the thickness of the basal segment of SMT and right ventricular free wall (RVFW). Pulmonary artery systolic pressures (PASPs) were estimated by transthoracic echocardiography (TTE) with continuous-wave Doppler analysis measuring maximal tricuspid regurgitation (TR) velocity. Late gadolinium enhancement (LGE) findings of CMR and brain natriuretic peptide (BNP) levels were also obtained in all patients and control group. RESULTS: The area and the thickness of the basal segment of SMT were higher in patients with IPAH and ES than control group (P<.001). Pulmonary artery dimension, end-diastolic diameter of RV, RVFW thickness, and BNP levels were found to be significantly correlated with PAP (P<.001). LGE was present at the insertion point of RV only in patients group (P<.001). CONCLUSIONS: Increased area and thickness of the basal segment of SMT are easily measurable noninvasive markers of PH in patients with IPAH and ES.


Asunto(s)
Hipertensión Pulmonar Primaria Familiar/diagnóstico por imagen , Hipertensión Pulmonar Primaria Familiar/fisiopatología , Hipertrofia Ventricular Derecha/diagnóstico por imagen , Hipertrofia Ventricular Derecha/fisiopatología , Imagen por Resonancia Magnética/métodos , Adulto , Hipertensión Pulmonar Primaria Familiar/complicaciones , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Hipertrofia Ventricular Derecha/complicaciones , Masculino , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Reproducibilidad de los Resultados , Volumen Sistólico/fisiología
4.
Catheter Cardiovasc Interv ; 88(4): 618-624, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26909784

RESUMEN

BACKGROUND: This study sought to compare various outcomes among a new specifically designed transcatheter paravalvular leak closure (TPVLC) device and the devices that are being utilized off-label. METHODS: Between April 2012 and January 2015, in a prospective two-center study, 52 patients who needed surgical reintervention due to a hemodynamically significant prosthetic paravalvular leak were studied. This study population was divided into two groups. Group I was composed of 32 patients who underwent paravalvular leak (PVL) closure with the currently available devices that are being utilized off-label, while group II consisted of 20 patients who were treated with the new specifically designed Occlutech PVL device. RESULTS: Demographic and clinical variables indicated a higher rate of atrial fibrillation (P = 0.027) and chronic obstructive airway disease (P = 0.009) in group II. The apical approach was the most commonly used intervention route used for group II (P = 0.019). The procedural success rate was 100% (29 of 29 leaks) in group II while the rate was 92% (39 of 42 leaks) in group I. However, more secondary events were observed in group I, but they did not reach statistical significance (8 vs. 1, P = 0.064). CONCLUSIONS: With its high procedural success rate and encouraging outcome results, the Occlutech device seems to satisfy the expectations of a specifically designed PVL closure device. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Insuficiencia Cardíaca/terapia , Enfermedades de las Válvulas Cardíacas/terapia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Válvulas Cardíacas , Hemólisis , Falla de Prótesis , Adulto , Anciano , Cateterismo Cardíaco/métodos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvulas Cardíacas/diagnóstico por imagen , Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Etiquetado de Productos , Estudios Prospectivos , Diseño de Prótesis , Retratamiento , Factores de Tiempo , Resultado del Tratamiento , Turquía
5.
Echocardiography ; 33(3): 346-52, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26382587

RESUMEN

PURPOSE: There are different clinical cardiac applications of dual source computed tomography (DSCT). Here, we aimed to compare the DSCT with the transthoracic echocardiography (TTE) for evaluating the Wilkins score and planimetric mitral valve area (MVA) of a rheumatic stenotic mitral valve. MATERIALS AND METHODS: We prospectively evaluated mitral valvular structure and function in 31 patients with known mitral stenosis undergoing electrocardiogram-gated, second-generation DSCT, in our heart center for different indications. Mitral valve was evaluated using Wilkins score, and also, the planimetric MVA was assessed. RESULTS: We found a significant difference between MVAs determined by DSCT (average 1.42 ± 0.44 cm2) and MVAs determined by TTE (average 1.35 ± 0.43 cm2 ; difference 0.07 ± 0.16 cm2; P = 0.018). Linear regression analysis revealed a good correlation between the two techniques (r = 0.934; P < 0.0001). The limits of agreement for DSCT and TTE in the Bland-Altman analysis were ±0.31 cm2 . DSCT using TTE as the reference enabled good discrimination between mild and moderate-to-severe stenosis and had an area under the ROC curve of 0.967 (CI 0.912-1.023; P < 0.0001). Wilkins scores obtained by DSCT (7.51 ± 1.17, range 5-10) and TTE (8.16 ± 1.27, range 6-10) had a moderate correlation (r = 0.686; P < 0.0001). CONCLUSION: We found that planimetric MVA measurements assessed by DSCT were closely correlated with MVA calculations by TTE. The moderate correlation was observed for the Wilkins score.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Ecocardiografía/métodos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Cardiopatía Reumática/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Anatol J Cardiol ; 15(1): 42-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25179884

RESUMEN

OBJECTIVE: The aim of this study was to assess subclinical left (LV) and right ventricular (RV) dysfunction novel load-independent isovolumic myocardial acceleration (IVA) derived from tissue Doppler imaging (TDI) in patient with metabolic syndrome (MetS). METHODS: This study had an observational case-control design. The study included 133 subjects which were divided into two groups: 75 patients with MetS and 58 controls without MetS. MetS was defined by the presence of ≥3 criteria according to ATP-NCEP III guidelines. All the subjects underwent laboratory blood tests and complete conventional echocardiography and TDI. Student's t, Mann-Whitney U, Pearson's, and multiple regression analysis were used for statistical analysis. RESULTS: There were no significant difference between two groups in terms of traditional echocardiographic parameters. The diastolic and global functions of both ventricles were significantly impaired in MetS group. The TDI-derived IVA of the LV and the RV was significantly lower in patients with MetS (3.2±0.9 vs. 4.0±1.4, p<0.001 and 2.6±0.7 vs. 3.1±0.9, p=0.001, respectively). Whereas, TDI derived systolic velocity (Sa), and peak myocardial velocity during isovolumic contraction (IVV) of both ventricles were similar between the two groups. In the multiple regression analysis, waist circumference and diastolic blood pressure were found to be an independent determinant of IVA of LV (b=-.223, 95% CI=-.034 -.002, p=0.004) and RV (b=-.527, 95% CI=-.085 -.020, p=0.002) respectively. CONCLUSION: MetS affects global, diastolic, and systolic functions of two ventricles. This disruption lead to decreased function of heart was related with raised risk factors of MetS.


Asunto(s)
Síndrome Metabólico , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/fisiopatología , Adulto , Estudios de Casos y Controles , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Sístole , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen
7.
Turk Kardiyol Dern Ars ; 42(3): 285-9, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24769823

RESUMEN

Behçet's disease is a chronic multisystem inflammatory disorder. There are limited data about cardiac involvement, but it is seen rarely. Herein, we present a 33-year-old male patient with heart failure secondary to a right ventricular mass. It was first diagnosed as inflammatory myofibroblastic tumor (IMT) histopathologically. During the postoperative follow-up, a thrombus was detected at the interatrial septum, and the patient was reevaluated. The diagnosis was possible Behçet's disease, and the mass, previously reported as IMT, was determined to be an organizing thrombus with a mixture of granulation tissue and thrombotic material.


Asunto(s)
Síndrome de Behçet/diagnóstico , Neoplasias Cardíacas/diagnóstico , Neoplasias de Tejido Muscular/diagnóstico , Adulto , Errores Diagnósticos , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA