Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Comput Tomogr ; 17(1): 52-59, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36216700

RESUMEN

BACKGROUND: FFRCT assesses the functional significance of lesions seen on CTCA, and may be a more efficient approach to chest pain evaluation. The FORECAST randomized trial found no significant difference in costs within the UK National Health Service, but implications for US costs are unknown. The purpose of this study was to compare costs in the FORECAST trial based on US healthcare cost weights, and to evaluate factors affecting costs. METHODS: Patients with stable chest pain were randomized either to the experimental strategy (CTCA with selective FFRCT), or to standard clinical pathways. Pre-randomization, the treating clinician declared the planned initial test. The primary outcome was nine-month cardiovascular care costs. RESULTS: Planned initial tests were CTCA in 912 patients (65%), stress testing in 393 (28%), and invasive angiography in 94 (7%). Mean US costs did not differ overall between the experimental strategy and standard care (cost difference +7% (+$324), CI -12% to +26%, p â€‹= â€‹0.49). Costs were 4% lower with the experimental strategy in the planned invasive angiography stratum (p for interaction â€‹= â€‹0.66). Baseline factors independently associated with costs were older age (+43%), male sex (+55%), diabetes (+37%), hypertension (+61%), hyperlipidemia (+94%), prior angina (+24%), and planned invasive angiography (+160%). Post-randomization cost drivers were coronary revascularization (+348%), invasive angiography (267%), and number of tests (+35%). CONCLUSIONS: Initial evaluation of chest pain using CTCA with FFRCT had similar US costs as standard care pathways. Costs were increased by baseline coronary risk factors and planned invasive angiography, and post-randomization invasive procedures and the number of tests. Registration at ClinicalTrials.gov (NCT03187639).


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Angiografía Coronaria/métodos , Medicina Estatal , Valor Predictivo de las Pruebas , Angina de Pecho/terapia , Angiografía por Tomografía Computarizada/métodos
2.
JAMA ; 327(19): 1875-1887, 2022 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-35579641

RESUMEN

Importance: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement and is the treatment of choice for patients at high operative risk. The role of TAVI in patients at lower risk is unclear. Objective: To determine whether TAVI is noninferior to surgery in patients at moderately increased operative risk. Design, Setting, and Participants: In this randomized clinical trial conducted at 34 UK centers, 913 patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk due to age or comorbidity were enrolled between April 2014 and April 2018 and followed up through April 2019. Interventions: TAVI using any valve with a CE mark (indicating conformity of the valve with all legal and safety requirements for sale throughout the European Economic Area) and any access route (n = 458) or surgical aortic valve replacement (surgery; n = 455). Main Outcomes and Measures: The primary outcome was all-cause mortality at 1 year. The primary hypothesis was that TAVI was noninferior to surgery, with a noninferiority margin of 5% for the upper limit of the 1-sided 97.5% CI for the absolute between-group difference in mortality. There were 36 secondary outcomes (30 reported herein), including duration of hospital stay, major bleeding events, vascular complications, conduction disturbance requiring pacemaker implantation, and aortic regurgitation. Results: Among 913 patients randomized (median age, 81 years [IQR, 78 to 84 years]; 424 [46%] were female; median Society of Thoracic Surgeons mortality risk score, 2.6% [IQR, 2.0% to 3.4%]), 912 (99.9%) completed follow-up and were included in the noninferiority analysis. At 1 year, there were 21 deaths (4.6%) in the TAVI group and 30 deaths (6.6%) in the surgery group, with an adjusted absolute risk difference of -2.0% (1-sided 97.5% CI, -∞ to 1.2%; P < .001 for noninferiority). Of 30 prespecified secondary outcomes reported herein, 24 showed no significant difference at 1 year. TAVI was associated with significantly shorter postprocedural hospitalization (median of 3 days [IQR, 2 to 5 days] vs 8 days [IQR, 6 to 13 days] in the surgery group). At 1 year, there were significantly fewer major bleeding events after TAVI compared with surgery (7.2% vs 20.2%, respectively; adjusted hazard ratio [HR], 0.33 [95% CI, 0.24 to 0.45]) but significantly more vascular complications (10.3% vs 2.4%; adjusted HR, 4.42 [95% CI, 2.54 to 7.71]), conduction disturbances requiring pacemaker implantation (14.2% vs 7.3%; adjusted HR, 2.05 [95% CI, 1.43 to 2.94]), and mild (38.3% vs 11.7%) or moderate (2.3% vs 0.6%) aortic regurgitation (adjusted odds ratio for mild, moderate, or severe [no instance of severe reported] aortic regurgitation combined vs none, 4.89 [95% CI, 3.08 to 7.75]). Conclusions and Relevance: Among patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk, TAVI was noninferior to surgery with respect to all-cause mortality at 1 year. Trial Registration: isrctn.com Identifier: ISRCTN57819173.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
3.
Clin Pharmacol Ther ; 111(6): 1222-1238, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35098531

RESUMEN

Contrast-induced nephropathy (CIN) is a major complication of imaging in patients with chronic kidney disease (CKD). The publication of an academic randomized controlled trial (RCT; n = 83) reporting oral (N)-acetylcysteine (NAC) to reduce CIN led to > 70 clinical trials, 23 systematic reviews, and 2 large RCTs showing no benefit. However, no mechanistic studies were conducted to determine how NAC might work; proposed mechanisms included renal artery vasodilatation and antioxidant boosting. We evaluated the proposed mechanisms of NAC action in participants with healthy and diseased kidneys. Four substudies were performed. Two randomized, double-blind, placebo-controlled, three-period crossover studies (n = 8) assessed the effect of oral and intravenous (i.v.) NAC in healthy kidneys in the presence/absence of iso-osmolar contrast (iodixanol). A third crossover study in patients with CKD stage III (CKD3) (n = 8) assessed the effect of oral and i.v. NAC without contrast. A three-arm randomized, double-blind, placebo-controlled parallel-group study, recruiting patients with CKD3 (n = 66) undergoing coronary angiography, assessed the effect of oral and i.v. NAC in the presence of contrast. We recorded systemic (blood pressure and heart rate) and renal (renal blood flow (RBF) and glomerular filtration rate (GFR)) hemodynamics, and antioxidant status, plus biomarkers of renal injury in patients with CKD3 undergoing angiography. Primary outcome for all studies was RBF over 8 hours after the start of i.v. NAC/placebo. NAC at doses used in previous trials of renal prophylaxis was essentially undetectable in plasma after oral administration. In healthy volunteers, i.v. NAC, but not oral NAC, increased blood pressure (mean area under the curve (AUC) mean arterial pressure (MAP): mean difference 29 h⋅mmHg, P = 0.019 vs. placebo), heart rate (28 h⋅bpm, P < 0.001), and RBF (714 h⋅mL/min, 8.0% increase, P = 0.006). Renal vasodilatation also occurred in the presence of contrast (RBF 917 h⋅mL/min, 12% increase, P = 0.005). In patients with CKD3 without contrast, only a rise in heart rate (34 h⋅bpm, P = 0.010) and RBF (288 h⋅mL/min, 6.0% increase, P = 0.001) occurred with i.v. NAC, with no significant effect on blood pressure (MAP rise 26 h⋅mmHg, P = 0.156). Oral NAC showed no effect. In patients with CKD3 receiving contrast, i.v. NAC increased blood pressure (MAP rise 52 h⋅mmHg, P = 0.008) but had no effect on RBF (151 h⋅mL/min, 3.0% increase, P = 0.470), GFR (29 h⋅mL/min/1.73m², P = 0.122), or markers of renal injury. Neither i.v. nor oral NAC affected plasma antioxidant status. We found oral NAC to be poorly absorbed and have no reno-protective effects. Intravenous, not oral, NAC caused renal artery vasodilatation in healthy volunteers but offered no protection to patients with CKD3 at risk of CIN. These findings emphasize the importance of mechanistic clinical studies before progressing to RCTs for novel interventions. Thousands were recruited to academic clinical trials without the necessary mechanistic studies being performed to confirm the approach had any chance of working.


Asunto(s)
Enfermedades Renales , Insuficiencia Renal Crónica , Acetilcisteína/uso terapéutico , Antioxidantes , Medios de Contraste/efectos adversos , Creatinina , Estudios Cruzados , Humanos , Insuficiencia Renal Crónica/tratamiento farmacológico , Resultado del Tratamiento
4.
Eur Heart J ; 43(13): 1307-1316, 2022 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-34617993

RESUMEN

AIMS: The SYNTAX II study evaluated the impact of advances in percutaneous coronary intervention (PCI), integrated into a single revascularization strategy, on outcomes of patients with de novo three-vessel disease. The study employed decision-making utilizing the SYNTAX score II, use of coronary physiology, thin-strut biodegradable polymer drug-eluting stents, intravascular ultrasound, enhanced treatments of chronic total occlusions, and optimized medical therapy. Patients treated with this approach were compared with predefined patients from the SYNTAX I trial. METHODS AND RESULTS: SYNTAX II was a multicentre, single-arm, open-label study of patients requiring revascularization who demonstrated clinical equipoise for treatment with either coronary artery bypass grafting (CABG) or PCI, predicted by the SYNTAX score II. The primary endpoint was major adverse cardiac and cerebrovascular events (MACCE), which included any revascularization. The comparators were a matched PCI cohort trial and a matched CABG cohort, both from the SYNTAX I trial. At 5 years, MACCE rate in SYNTAX II was significantly lower than in the SYNTAX I PCI cohort (21.5% vs. 36.4%, P < 0.001). This reflected lower rates of revascularization (13.8% vs. 23.8%, P < 0.001), and myocardial infarction (MI) (2.7% vs. 10.4%, P < 0.001), consisting of both procedural MI (0.2% vs. 3.8%, P < 0.001) and spontaneous MI (2.3% vs. 6.9%, P = 0.004). All-cause mortality was lower in SYNTAX II (8.1% vs. 13.8%, P = 0.013) reflecting a lower rate of cardiac death (2.8% vs. 8.4%, P < 0.001). Major adverse cardiac and cerebrovascular events' outcomes at 5 years among patients in SYNTAX II and predefined patients in the SYNTAX I CABG cohort were similar (21.5% vs. 24.6%, P = 0.35). CONCLUSIONS: Use of the SYNTAX II PCI strategy in patients with de novo three-vessel disease led to improved and durable clinical results when compared to predefined patients treated with PCI in the original SYNTAX I trial. A predefined exploratory analysis found no significant difference in MACCE between SYNTAX II PCI and matched SYNTAX I CABG patients at 5-year follow-up.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento
5.
Int J Cardiol ; 347: 1-7, 2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-34774885

RESUMEN

BACKGROUND: Ischemia-reperfusion injury remains a major clinical problem in patients with ST-elevation myocardial infarction (STEMI), leading to myocardial damage despite early reperfusion by primary percutaneous coronary intervention (PPCI). There are no effective therapies to limit ischemia-reperfusion injury, which is caused by multiple pathways activated by rapid tissue reoxygenation and the generation of reactive oxygen species (ROS). FDY-5301 contains sodium iodide, a ubiquitous inorganic halide and elemental reducing agent that can act as a catalytic anti-peroxidant. We tested the feasibility, safety and potential utility of FDY-5301 as a treatment to limit ischemia-reperfusion injury, in patients with first-time STEMI undergoing emergency PPCI. METHODS: STEMI patients (n = 120, median 62 years) presenting within 12 h of chest pain onset were randomized at 20 PPCI centers, in a double blind Phase 2 clinical trial, to receive FDY-5301 (0.5, 1.0 or 2.0 mg/kg) or placebo prior to reperfusion, to evaluate the feasibility endpoints. Participants underwent continuous ECG monitoring for 14 days after PPCI to address pre-specified cardiac arrhythmia safety end points and cardiac magnetic resonance imaging (MRI) at 72 h and at 3 months to assess exploratory efficacy end points. RESULTS: Intravenous FDY-5301 was delivered before re-opening of the infarct-related artery in 97% participants and increased plasma iodide levels ~1000-fold within 2 min. There was no significant increase in the primary safety end point of incidence of cardiac arrhythmias of concern. MRI at 3 months revealed median final infarct sizes in placebo vs. 2.0 mg/kg FDY-5301-treated patients of 14.9% vs. 8.5%, and LV ejection fractions of 53.9% vs. 63.2%, respectively, although the study was not powered to detect statistical significance. In patients receiving FDY-5301, there was a significant reduction in the levels of MPO, MMP2 and NTproBNP after PPCI, but no reduction with placebo. CONCLUSIONS: Intravenous FDY-5301, delivered immediately prior to PPCI in acute STEMI, is feasible, safe, and shows potential efficacy. A larger trial is justified to test the effects of FDY-5301 on acute ischemia-reperfusion injury and clinical outcomes. CLINICAL TRIAL REGISTRATION: CT.govNCT03470441; EudraCT 2017-000047-41.


Asunto(s)
Infarto de la Pared Anterior del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Arritmias Cardíacas , Método Doble Ciego , Humanos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Resultado del Tratamiento
6.
Circulation ; 144(17): 1396-1408, 2021 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-34455857

RESUMEN

BACKGROUND: Major uncertainties remain regarding disease activity within the retained native aortic valve, and regarding bioprosthetic valve durability, after transcatheter aortic valve implantation (TAVI). We aimed to assess native aortic valve disease activity and bioprosthetic valve durability in patients with TAVI in comparison with subjects with bioprosthetic surgical aortic valve replacement (SAVR). METHODS: In a multicenter cross-sectional observational cohort study, patients with TAVI or bioprosthetic SAVR underwent baseline echocardiography, computed tomography angiography, and 18F-sodium fluoride (18F-NaF) positron emission tomography. Participants (n=47) were imaged once with 18F-NaF positron emission tomography/computed tomography either at 1 month (n=9, 19%), 2 years (n=22, 47%), or 5 years (16, 34%) after valve implantation. Patients subsequently underwent serial echocardiography to assess for changes in valve hemodynamic performance (change in peak aortic velocity) and evidence of structural valve dysfunction. Comparisons were made with matched patients with bioprosthetic SAVR (n=51) who had undergone the same imaging protocol. RESULTS: In patients with TAVI, native aortic valves demonstrated 18F-NaF uptake around the outside of the bioprostheses that showed a modest correlation with the time from TAVI (r=0.36, P=0.023). 18F-NaF uptake in the bioprosthetic leaflets was comparable between the SAVR and TAVI groups (target-to-background ratio, 1.3 [1.2-1.7] versus 1.3 [1.2-1.5], respectively; P=0.27). The frequencies of imaging evidence of bioprosthetic valve degeneration at baseline were similar on echocardiography (6% versus 8%, respectively; P=0.78), computed tomography (15% versus 14%, respectively; P=0.87), and positron emission tomography (15% versus 29%, respectively; P=0.09). Baseline 18F-NaF uptake was associated with a subsequent change in peak aortic velocity for both TAVI (r=0.7, P<0.001) and SAVR (r=0.7, P<0.001). On multivariable analysis, 18F-NaF uptake was the only predictor of peak velocity progression (P<0.001). CONCLUSIONS: In patients with TAVI, native aortic valves demonstrate evidence of ongoing active disease. Across imaging modalities, TAVI degeneration is of similar magnitude to bioprosthetic SAVR, suggesting comparable midterm durability. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02304276.


Asunto(s)
Enfermedad de la Válvula Aórtica/fisiopatología , Prótesis Valvulares Cardíacas/normas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Estudios Transversales , Progresión de la Enfermedad , Femenino , Humanos , Masculino
7.
Eur Heart J ; 42(37): 3844-3852, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34269376

RESUMEN

AIMS: Fractional flow reserve (FFRCT) using computed tomography coronary angiography (CTCA) determines both the presence of coronary artery disease and vessel-specific ischaemia. We tested whether an evaluation strategy based on FFRCT would improve economic and clinical outcomes compared with standard care. METHODS AND RESULTS: Overall, 1400 patients with stable chest pain in 11 centres were randomized to initial testing with CTCA with selective FFRCT (experimental group) or standard clinical care pathways (standard group). The primary endpoint was total cardiac costs at 9 months. Secondary endpoints were angina status, quality of life, major adverse cardiac and cerebrovascular events, and use of invasive coronary angiography. Randomized groups were similar at baseline. Most patients had an initial CTCA: 439 (63%) in the standard group vs. 674 (96%) in the experimental group, 254 of whom (38%) underwent FFRCT. Mean total cardiac costs were higher by £114 (+8%) in the experimental group, with a 95% confidence interval from -£112 (-8%) to +£337 (+23%), though the difference was not significant (P = 0.10). Major adverse cardiac and cerebrovascular events did not differ significantly (10.2% in the experimental group vs. 10.6% in the standard group) and angina and quality of life improved to a similar degree over follow-up in both randomized groups. Invasive angiography was reduced significantly in the experimental group (19% vs. 25%, P = 0.01). CONCLUSION: A strategy of CTCA with selective FFRCT in patients with stable angina did not differ significantly from standard clinical care pathways in cost or clinical outcomes, but did reduce the use of invasive coronary angiography.


Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Angina Estable/diagnóstico por imagen , Angina Estable/terapia , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios , Humanos , Valor Predictivo de las Pruebas , Calidad de Vida
9.
Br J Cardiol ; 28(2): 20, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35747458

RESUMEN

Increased demand for transcatheter aortic valve implantation (TAVI) procedures for patients with severe aortic stenosis has not been matched with a proportional increase in available resources in recent years. This article highlights the importance of developing integrated care pathways for TAVI, which incorporate standardised protocols for permanent pacemaker implantation (PPI) to ensure best practice, increase service efficiency and reduce rates of PPI post-TAVI.

10.
Open Heart ; 7(2)2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32907920

RESUMEN

BACKGROUND: Balloon aortic valvuloplasty (BAV) remains a treatment option for the selected patients with severe aortic stenosis. We examined clinical outcomes and predictors of prognosis in patients undergoing BAV for severe aortic stenosis. METHODS: We identified all patients undergoing BAV from January 2010 to March 2018 (n=167) at a single transcatheter aortic valve implantation (TAVI) centre. Patient demographics, investigations, subsequent interventions and clinical outcomes were obtained from electronic health records. RESULTS: Patients undergoing BAV were elderly (median age 80, IQR 73-86 years) and half (n=87, 52%) were male. All-cause mortality at 30 days and 12 months was 11% and 43%, respectively. Reduce ejection fraction (EF 30%-50%: HR 1.76, 95% CI 1.05 to 2.94; EF <30%: HR 1.90, 95% CI 1.12 to 3.20) was the only independent predictor at baseline of overall mortality. Median survival was 212 (IQR 54-490) days from the index procedure. Mortality at 1 year was lowest in patients who subsequently underwent TAVI or SAVR but high among those who had no further interventions or those who had a repeat BAV (14%, 19%, 60%, 89% respectively, log-rank p<0.001). CONCLUSION: BAV as a bridge to definitive aortic valve intervention in carefully selected patients offers acceptable outcomes. These contemporary observational findings demonstrate the ongoing potential utility of BAV in the TAVI era.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Valvuloplastia con Balón , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Femenino , Hemodinámica , Humanos , Masculino , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30394657

RESUMEN

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Irlanda , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido
12.
JACC Cardiovasc Interv ; 12(3): 259-270, 2019 02 11.
Artículo en Inglés | MEDLINE | ID: mdl-30409759

RESUMEN

OBJECTIVES: The aims of the present study were to investigate the applicability of quantitative flow ratio (QFR) in patients with 3-vessel disease and to demonstrate the impact of functional SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score derived from QFR (fSSQFR) on clinical outcomes. BACKGROUND: The applicability of QFR in patients with 3-vessel disease and the feasibility of fSSQFR have not yet been investigated. METHODS: All lesions interrogated using instantaneous wave-free ratio and/or fractional flow reserve in the SYNTAX II trial were retrospectively screened and analyzed for QFR. The diagnostic performance of QFR was investigated using hybrid wire-derived pressure assessment (instantaneous wave-free ratio and fractional flow reserve), used in the trial as a reference. Patients with analyzable QFR in 3 vessels were stratified according to fSSQFR to evaluate its clinical prognostic value on the basis of 2-year patient-oriented composite endpoint. RESULTS: QFRs were analyzable in 71.0% of lesions (836 lesions). The diagnostic performance of QFR to predict binary wire-based ischemia was substantial (area under the curve 0.81, accuracy 73.8%), with a positive predictive value of 85.9%. Independent predictors of diagnostic discordance were lesions in side branches, involvement of bifurcation or trifurcation, and small vessel. According to the 2-year patient-oriented composite endpoint, fSSQFR reclassified 26.1% of the patients (36 of 138) in the high- to intermediate-risk group into the low-risk group appropriately (net reclassification improvement 0.32; p < 0.001). The area under the curve for fSSQFR to predict the 2-year patient-oriented composite endpoint was higher than that of the classic anatomic SYNTAX score (0.68 vs. 0.56; p = 0.002). CONCLUSIONS: QFR demonstrated substantial applicability in patients with 3-vessel disease. The fSSQFR has the potential to further refine prognostic risk estimation compared with the classic anatomic SYNTAX score.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Anciano , Cateterismo Cardíaco , Ensayos Clínicos como Asunto , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/terapia , Vasos Coronarios/fisiopatología , Stents Liberadores de Fármacos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Cardiovasc Revasc Med ; 20(9): 775-781, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30420279

RESUMEN

INTRODUCTION: Intravascular ultrasound (IVUS) is a useful adjunct to guide percutaneous coronary intervention (PCI). Correlating IVUS images with angiographic findings can be challenging. We evaluated the utility of a novel co-registration system for IVUS and coronary angiography. METHODS AND RESULTS: A 3-D virtual catheter trajectory was constructed from separate angiographic imaging runs using bespoke software. Intravascular ultrasound images were obtained using a commercially available mechanical rotational transducer with motorized pullback. Co-registration of ultrasound and angiographic images was then performed retrospectively based on the length of pullback, the 3-D trajectory and the start position of the catheter. Validation was performed in a spherical phantom model and in vivo in the coronary circulation of patients undergoing coronary angiography and intravascular imaging for clinical purposes. 111 paired angiographic and IVUS runs were performed in 3 phantom models. The differences between the reference length and the length measured on the 3D reconstructed path was -0.01 ±â€¯0.40 mm. Intra-observer variability was 0.4%. We enrolled 25 patients in 3 European hospitals and performed 35 co-registration attempts with an 86% success rate. 71 landmarks were selected by the first operator, 68 by the second. Differences between angiographic and IVUS landmarks were -0.22 ±â€¯0.72 mm and 0.05 ±â€¯1.01 mm, respectively. Inter-observer variability was 0.23 ±â€¯0.63 mm. CONCLUSION: We present a novel method for the co-registration of IVUS and coronary angiographic images. This system performed well in a phantom model and using images obtained from the human coronary circulation. CLASSIFICATIONS: Innovation, intravascular ultrasound, other technique.


Asunto(s)
Cateterismo Cardíaco , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen Multimodal , Ultrasonografía Intervencional , Adulto , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Angiografía Coronaria/instrumentación , Europa (Continente) , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Ultrasonografía Intervencional/instrumentación , Adulto Joven
14.
Eur Heart J ; 38(42): 3124-3134, 2017 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-29020367

RESUMEN

Aims: To investigate if recent technical and procedural developments in percutaneous coronary intervention (PCI) significantly influence outcomes in appropriately selected patients with three-vessel (3VD) coronary artery disease. Methods and results: The SYNTAX II study is a multicenter, all-comers, open-label, single arm study that investigated the impact of a contemporary PCI strategy on clinical outcomes in patients with 3VD in 22 centres from four European countries. The SYNTAX-II strategy includes: heart team decision-making utilizing the SYNTAX Score II (a clinical tool combining anatomical and clinical factors), coronary physiology guided revascularisation, implantation of thin strut bioresorbable-polymer drug-eluting stents, intravascular ultrasound (IVUS) guided stent implantation, contemporary chronic total occlusion revascularisation techniques and guideline-directed medical therapy. The rate of major adverse cardiac and cerebrovascular events (MACCE [composite of all-cause death, cerebrovascular event, any myocardial infarction and any revascularisation]) at one year was compared to a predefined PCI cohort from the original SYNTAX-I trial selected on the basis of equipoise 4-year mortality between CABG and PCI. As an exploratory endpoint, comparisons were made with the historical CABG cohort of the original SYNTAX-I trial. Overall 708 patients were screened and discussed within the heart team; 454 patients were deemed appropriate to undergo PCI. At one year, the SYNTAX-II strategy was superior to the equipoise-derived SYNTAX-I PCI cohort (MACCE SYNTAX-II 10.6% vs. SYNTAX-I 17.4%; HR 0.58, 95% CI 0.39-0.85, P = 0.006). This difference was driven by a significant reduction in the incidence of MI (HR 0.27, 95% CI 0.11-0.70, P = 0.007) and revascularisation (HR 0.57, 95% CI 0.37-0.9, P = 0.015). Rates of all-cause death (HR 0.69, 95% CI 0.27-1.73, P = 0.43) and stroke (HR 0.69, 95% CI 0.10-4.89, P = 0.71) were similar. The rate of definite stent thrombosis was significantly lower in SYNTAX-II (HR 0.26, 95% CI 0.07-0.97, P = 0.045). Conclusion: At one year, clinical outcomes with the SYNTAX-II strategy were associated with improved clinical results compared to the PCI performed in comparable patients from the original SYNTAX-I trial. Longer term follow-up is awaited and a randomized clinical trial with contemporary CABG is warranted. ClinicalTrials.gov Identifier: NCT02015832.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Oclusión Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Implantes Absorbibles , Anciano , Angioplastia Coronaria con Balón/métodos , Atorvastatina/uso terapéutico , Puente de Arteria Coronaria/métodos , Quimioterapia Combinada , Stents Liberadores de Fármacos , Femenino , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Masculino , Infarto del Miocardio/cirugía , Inhibidores de Agregación Plaquetaria/uso terapéutico , Rosuvastatina Cálcica/uso terapéutico , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos
15.
Catheter Cardiovasc Interv ; 90(5): 745-753, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28766832

RESUMEN

AIM: Fractional flow reserve (FFR) allows for physiological definition of coronary lesion severity but requires induction of maximal coronary circulation hyperemia with administration of adenosine leading to coronary resistive vessel vasodilatation. However, the hyperemic response to adenosine, and therefore the calculation of FFR, may be affected by dysfunction of the coronary microvasculature. The aim was to define the relationship between basal Pd /Pa and FFR and identify lesion-independent predictors of the change in Pd /Pa with hyperemia. METHODS AND RESULTS: One hundred and sixty-six consecutive patients undergoing FFR measurement were prospectively enrolled (mean age 62.6 ± 10.3 years, 27% females). Basal Pd /Pa , FFR, and delta Pd /Pa (difference between basal Pd /Pa and FFR) were recorded. Independent predictors of delta Pd /Pa included angiographic lesion severity, lesion length, gender, body mass index, and total cholesterol:HDL cholesterol ratio. The best basal Pd /Pa cutoff value to predict lesion physiological significance was 0.87 (positive predictive value of 100% for an FFR value ≤0.80) and the best cutoff for nonsignificance was 0.93 (negative predictive value of 98% for an FFR value >0.80). CONCLUSION: The delta Pd /Pa may be affected by patient gender, body mass index, and cholesterol profile. A basal Pd /Pa value of ≥0.93 is highly predictive of an FFR >0.80. Conversely, a basal Pd /Pa value of ≤0.87 is highly predictive of an FFR ≤0.80. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Presión Sanguínea , Cateterismo Cardíaco/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Adenosina/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Colesterol/sangre , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/sangre , Estenosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Hiperemia/fisiopatología , Masculino , Microcirculación , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Factores Sexuales , Vasodilatadores/administración & dosificación
16.
Eur Radiol ; 27(3): 1114-1124, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27334015

RESUMEN

OBJECTIVES: Computed tomography (CT) can perform comprehensive cardiac imaging. We compared CT coronary angiography (CTCA) and CT myocardial perfusion (CTP) with 15O-water positron emission tomography (PET) and invasive coronary angiography (ICA) with fractional flow reserve (FFR). METHODS: 51 patients (63 (61-65) years, 80 % male) with known/suspected coronary artery disease (CAD) underwent 320-multidetector CTCA followed by "snapshot" adenosine stress CTP. Of these 22 underwent PET and 47 ICA/FFR. Obstructive CAD was defined as CTCA stenosis >50 % and CTP hypoperfusion, ICA stenosis >70 % or FFR <0.80. RESULTS: PET hyperaemic myocardial blood flow (MBF) was lower in obstructive than non-obstructive territories defined by ICA/FFR (1.76 (1.32-2.20) vs 3.11 (2.44-3.79) mL/(g/min), P < 0.001) and CTCA/CTP (1.76 (1.32-2.20) vs 3.12 (2.44-3.79) mL/(g/min), P < 0.001). Baseline and hyperaemic CT attenuation density was lower in obstructive than non-obstructive territories (73 (71-76) vs 86 (84-88) HU, P < 0.001 and 101 (96-106) vs 111 (107-114) HU, P 0.001). PET hyperaemic MBF corrected for rate pressure product correlated with CT attenuation density (r = 0.579, P < 0.001). There was excellent per-patient sensitivity (96 %), specificity (85 %), negative predictive value (90 %) and positive predictive value (94 %) for CTCA/CTP vs ICA/FFR. CONCLUSION: CT myocardial attenuation density correlates with 15O-water PET MBF. CTCA and CTP can accurately identify obstructive CAD. KEY POINTS: •CT myocardial perfusion can aid the assessment of suspected coronary artery disease. • CT attenuation density from "snapshot" imaging is a marker of myocardial perfusion. • CT myocardial attenuation density correlates with 15 O-water PET myocardial blood flow. • CT attenuation density is lower in obstructive territories defined by invasive angiography. • Diagnostic accuracy of CTCA+CTP is comparable to invasive angiography + fractional flow reserve.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica/métodos , Adenosina , Anciano , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radioisótopos de Oxígeno , Tomografía de Emisión de Positrones/métodos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Vasodilatadores , Agua
17.
J Am Heart Assoc ; 4(9): e001956, 2015 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-26316523

RESUMEN

BACKGROUND: Preclinical data suggest that an acute inflammatory response following myocardial infarction (MI) accelerates systemic atherosclerosis. Using combined positron emission and computed tomography, we investigated whether this phenomenon occurs in humans. METHODS AND RESULTS: Overall, 40 patients with MI and 40 with stable angina underwent thoracic 18F-fluorodeoxyglucose combined positron emission and computed tomography scan. Radiotracer uptake was measured in aortic atheroma and nonvascular tissue (paraspinal muscle). In 1003 patients enrolled in the Global Registry of Acute Coronary Events, we assessed whether infarct size predicted early (≤30 days) and late (>30 days) recurrent coronary events. Compared with patients with stable angina, patients with MI had higher aortic 18F-fluorodeoxyglucose uptake (tissue-to-background ratio 2.15±0.30 versus 1.84±0.18, P<0.0001) and plasma C-reactive protein concentrations (6.50 [2.00 to 12.75] versus 2.00 [0.50 to 4.00] mg/dL, P=0.0005) despite having similar aortic (P=0.12) and less coronary (P=0.006) atherosclerotic burden and similar paraspinal muscular 18F-fluorodeoxyglucose uptake (P=0.52). Patients with ST-segment elevation MI had larger infarcts (peak plasma troponin 32 300 [10 200 to >50 000] versus 3800 [1000 to 9200] ng/L, P<0.0001) and greater aortic 18F-fluorodeoxyglucose uptake (2.24±0.32 versus 2.02±0.21, P=0.03) than those with non-ST-segment elevation MI. Peak plasma troponin concentrations correlated with aortic 18F-fluorodeoxyglucose uptake (r=0.43, P=0.01) and, on multivariate analysis, independently predicted early (tertile 3 versus tertile 1: relative risk 4.40 [95% CI 1.90 to 10.19], P=0.001), but not late, recurrent MI. CONCLUSIONS: The presence and extent of MI is associated with increased aortic atherosclerotic inflammation and early recurrent MI. This finding supports the hypothesis that acute MI exacerbates systemic atherosclerotic inflammation and remote plaque destabilization: MI begets MI. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01749254.


Asunto(s)
Aortitis/diagnóstico , Aterosclerosis/diagnóstico , Enfermedad de la Arteria Coronaria/diagnóstico , Infarto del Miocardio/diagnóstico , Anciano , Aortitis/sangre , Aortitis/diagnóstico por imagen , Aterosclerosis/sangre , Aterosclerosis/diagnóstico por imagen , Biomarcadores/sangre , Proteína C-Reactiva/metabolismo , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Análisis Multivariante , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico por imagen , Placa Aterosclerótica , Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Estudios Prospectivos , Radiofármacos , Recurrencia , Sistema de Registros , Factores de Riesgo , Escocia , Factores de Tiempo , Tomografía Computarizada por Rayos X , Troponina/sangre
18.
Open Heart ; 2(1): e000234, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26019881

RESUMEN

INTRODUCTION: Observer variability can influence the assessment of CT coronary angiography (CTCA) and the subsequent diagnosis of angina pectoris due to coronary heart disease. METHODS: We assessed 210 CTCAs from the Scottish COmputed Tomography of the HEART (SCOT-HEART) trial for intraobserver and interobserver variability. Calcium score, coronary angiography and image quality were evaluated. Coronary artery disease was defined as none (<10%), mild (10-49%), moderate (50-70%) and severe (>70%) luminal stenosis and classified as no (<10%), non-obstructive (10-70%) or obstructive (>70%) coronary artery disease. Post-CTCA diagnosis of angina pectoris due to coronary heart disease was classified as yes, probable, unlikely or no. RESULTS: Patients had a mean body mass index of 29 (28, 30) kg/m(2), heart rate of 58 (57, 60)/min and 62% were men. Intraobserver and interobserver agreements for the presence or absence of coronary artery disease were excellent (95% agreement, κ 0.884 (0.817 to 0.951) and good (91%, 0.791 (0.703 to 0.879)). Intraobserver and interobserver agreement for the presence or absence of angina pectoris due to coronary heart disease were excellent (93%, 0.842 (0.918 to 0.755) and good (86%, 0.701 (0.799 to 0.603)), respectively. Observer variability of calcium score was excellent for calcium scores below 1000. More segments were categorised as uninterpretable with 64-multidetector compared to 320-multidetector CTCA (10.1% vs 2.6%, p<0.001) but there was no difference in observer variability. CONCLUSIONS: Multicentre multidetector CTCA has excellent agreement in patients under investigation for suspected angina due to coronary heart disease. TRIAL REGISTRATION NUMBER: NCT01149590.

20.
N Engl J Med ; 372(6): 519-27, 2015 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-25651246

RESUMEN

BACKGROUND: Many patients with coronary artery disease who are not candidates for revascularization have refractory angina despite standard medical therapy. The balloon-expandable, stainless steel, hourglass-shaped, coronary-sinus reducing device creates a focal narrowing and increases pressure in the coronary sinus, thus redistributing blood into ischemic myocardium. METHODS: We randomly assigned 104 patients with Canadian Cardiovascular Society (CCS) class III or IV angina (on a scale from I to IV, with higher classes indicating greater limitations on physical activity owing to angina) and myocardial ischemia, who were not candidates for revascularization, to implantation of the device (treatment group) or to a sham procedure (control group). The primary end point was the proportion of patients with an improvement of at least two CCS angina classes at 6 months. RESULTS: A total of 35% of the patients in the treatment group (18 of 52 patients), as compared with 15% of those in the control group (8 of 52), had an improvement of at least two CCS angina classes at 6 months (P=0.02). The device was also associated with improvement of at least one CCS angina class in 71% of the patients in the treatment group (37 of 52 patients), as compared with 42% of those in the control group (22 of 52) (P=0.003). Quality of life as assessed with the use of the Seattle Angina Questionnaire was significantly improved in the treatment group, as compared with the control group (improvement on a 100-point scale, 17.6 vs. 7.6 points; P=0.03). There were no significant between-group differences in improvement in exercise time or in the mean change in the wall-motion index as assessed by means of dobutamine echocardiography. At 6 months, 1 patient in the treatment group had had a myocardial infarction; in the control group, 1 patient had died and 3 had had a myocardial infarction. CONCLUSIONS: In this small clinical trial, implantation of the coronary-sinus reducing device was associated with significant improvement in symptoms and quality of life in patients with refractory angina who were not candidates for revascularization. (Funded by Neovasc; COSIRA ClinicalTrials.gov number, NCT01205893.).


Asunto(s)
Angina de Pecho/terapia , Catéteres Cardíacos , Seno Coronario , Revascularización Miocárdica/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Angina de Pecho/clasificación , Cateterismo Cardíaco , Angiografía Coronaria , Seno Coronario/diagnóstico por imagen , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Gravedad del Paciente , Calidad de Vida , Mallas Quirúrgicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA