Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cardiovasc Digit Health J ; 5(3): 141-148, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38989041

RESUMEN

Background: Despite near-global availability of remote monitoring (RM) in patients with cardiac implantable electronic devices (CIED), there is a high geographical variability in the uptake and use of RM. The underlying reasons for this geographic disparity remain largely unknown. Objectives: To study the determinants of worldwide RM utilization and identify locoregional barriers of RM uptake. Methods: An international survey was administered to all CIED clinic personnel using the Heart Rhythm Society global network collecting demographic information, as well as information on the use of RM, the organization of the CIED clinic, and details on local reimbursement and clinic funding. The most complete response from each center was included in the current analysis. Stepwise forward multivariate linear regression was performed to identify determinants of the percentage of patients with a CIED on RM. Results: A total of 302 responses from 47 different countries were included, 61.3% by physicians and 62.3% from hospital-based CIED clinics. The median percentage of CIED patients on RM was 80% (interquartile range, 40-90). Predictors of RM use were gross national income per capita (0.76% per US$1000, 95% CI 0.72-1.00, P < .001), office-based clinics (7.48%, 95% CI 1.53-13.44, P = .014), and presence of clinic funding (per-patient payment model 7.90% [95% CI 0.63-15.17, P = .033); global budget 3.56% (95% CI -6.14 to 13.25, P = .471]). Conclusion: The high variability in RM utilization can partly be explained by economic and structural barriers that may warrant specific efforts by all stakeholders to increase RM utilization.

2.
Radiol Cardiothorac Imaging ; 6(3): e230247, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38900026

RESUMEN

Purpose To use unsupervised machine learning to identify phenotypic clusters with increased risk of arrhythmic mitral valve prolapse (MVP). Materials and Methods This retrospective study included patients with MVP without hemodynamically significant mitral regurgitation or left ventricular (LV) dysfunction undergoing late gadolinium enhancement (LGE) cardiac MRI between October 2007 and June 2020 in 15 European tertiary centers. The study end point was a composite of sustained ventricular tachycardia, (aborted) sudden cardiac death, or unexplained syncope. Unsupervised data-driven hierarchical k-mean algorithm was utilized to identify phenotypic clusters. The association between clusters and the study end point was assessed by Cox proportional hazards model. Results A total of 474 patients (mean age, 47 years ± 16 [SD]; 244 female, 230 male) with two phenotypic clusters were identified. Patients in cluster 2 (199 of 474, 42%) had more severe mitral valve degeneration (ie, bileaflet MVP and leaflet displacement), left and right heart chamber remodeling, and myocardial fibrosis as assessed with LGE cardiac MRI than those in cluster 1. Demographic and clinical features (ie, symptoms, arrhythmias at Holter monitoring) had negligible contribution in differentiating the two clusters. Compared with cluster 1, the risk of developing the study end point over a median follow-up of 39 months was significantly higher in cluster 2 patients (hazard ratio: 3.79 [95% CI: 1.19, 12.12], P = .02) after adjustment for LGE extent. Conclusion Among patients with MVP without significant mitral regurgitation or LV dysfunction, unsupervised machine learning enabled the identification of two phenotypic clusters with distinct arrhythmic outcomes based primarily on cardiac MRI features. These results encourage the use of in-depth imaging-based phenotyping for implementing arrhythmic risk prediction in MVP. Keywords: MR Imaging, Cardiac, Cardiac MRI, Mitral Valve Prolapse, Cluster Analysis, Ventricular Arrhythmia, Sudden Cardiac Death, Unsupervised Machine Learning Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Prolapso de la Válvula Mitral , Fenotipo , Aprendizaje Automático no Supervisado , Humanos , Prolapso de la Válvula Mitral/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sistema de Registros , Imagen por Resonancia Cinemagnética/métodos , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Adulto , Imagen por Resonancia Magnética
3.
J Clin Med ; 13(9)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38731198

RESUMEN

Background: Mitral valve prolapse (MVP) and mitral annular disjunction (MAD) are common valvular abnormalities that have been associated with ventricular arrhythmias (VA). Cardiac magnetic resonance imaging (CMR) has a key role in risk stratification of VA, including assessment of late gadolinium enhancement (LGE). Methods: Single-center retrospective analysis of patients with MVP or MAD who had >1 CMR and >1 24 h Holter registration available. Data are presented in detail, including evolution of VA and presence of LGE over time. Results: A total of twelve patients had repeated CMR and Holter registrations available, of which in four (33%) patients, it was conducted before and after minimal invasive mitral valve repair (MVR). After a median of 4.7 years, four out of eight (50%) patients without surgical intervention had new areas of LGE. New LGE was observed in the papillary muscles and the mid to basal inferolateral wall. In four patients, presenting with syncope or high-risk non-sustained ventricular tachycardia (VT), programmed ventricular stimulation was performed and in two (50%), sustained monomorphic VT was easily inducible. In two patients who underwent MVR, new LGE was observed in the basal inferolateral wall of which one presented with an increased burden of VA. Conclusions: In patients with MVP and MAD, repeat CMR may show new LGE in a small subset of patients, even shortly after MVR. A subgroup of patients who presented with an increase in VA burden showed new LGE upon repeat CMR. VA in patients with MVP and MAD are part of a heterogeneous spectrum that requires further investigation to establish risk stratification strategies.

5.
J Clin Med ; 13(7)2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38610667

RESUMEN

Background: Cardiac resynchronization therapy (CRT) has evolved into an established therapy for patients with chronic heart failure and a wide QRS complex. Data on long-term outcomes over time are scarce and the criteria for implantation remain a subject of investigation. Methods: An international, multicenter, retrospective registry includes 2275 patients who received CRT between 30 November 2000 and 31 December 2019, with a mean follow-up of 3.6 ± 2.7 years. Four time periods were defined, based on landmark trials and guidelines. The combined endpoint was a composite of all-cause mortality, heart transplantation, or left ventricular assist device implantation. Results: The composite endpoint occurred in 656 patients (29.2%). The mean annual implantation rate tripled from 31.5 ± 17.4/year in the first period to 107.4 ± 62.4/year in the last period. In the adjusted Cox regression analysis, the hazard ratio for the composite endpoint was not statistically different between time periods. When compared to sinus rhythm with left bundle branch block (LBBB), a non-LBBB conduction pattern (sinus rhythm: HR 1.51, 95% CI 1.12-2.03; atrial fibrillation: HR 2.08, 95% CI 1.30-3.33) and a QRS duration below 130 ms (HR 1.64, 95% CI 1.29-2.09) were associated with a higher hazard ratio. Conclusions: Despite innovations, an adjusted regression analysis revealed stable overall survival over time, which can at least partially be explained by a shift in patient characteristics.

6.
Eur J Prev Cardiol ; 31(5): 560-566, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37943680

RESUMEN

AIMS: Cardiotoxicity is a serious side effect of anthracycline treatment, most commonly manifesting as a reduction in left ventricular ejection fraction (EF). Early recognition and treatment have been advocated, but robust, convenient, and cost-effective alternatives to cardiac imaging are missing. Recent developments in artificial intelligence (AI) techniques applied to electrocardiograms (ECGs) may fill this gap, but no study so far has demonstrated its merit for the detection of an abnormal EF after anthracycline therapy. METHODS AND RESULTS: Single centre consecutive cohort study of all breast cancer patients with ECG and transthoracic echocardiography (TTE) evaluation before and after (neo)adjuvant anthracycline chemotherapy. Patients with HER2-directed therapy, metastatic disease, second primary malignancy, or pre-existing cardiovascular disease were excluded from the analyses as were patients with EF decline for reasons other than anthracycline-induced cardiotoxicity. Primary readout was the diagnostic performance of AI-ECG by area under the curve (AUC) for EFs < 50%. Of 989 consecutive female breast cancer patients, 22 developed a decline in EF attributed to anthracycline therapy over a follow-up time of 9.8 ± 4.2 years. After exclusion of patients who did not have ECGs within 90 days of a TTE, 20 cases and 683 controls remained. The AI-ECG model detected an EF < 50% and ≤ 35% after anthracycline therapy with an AUC of 0.93 and 0.94, respectively. CONCLUSION: These data support the use of AI-ECG for cardiotoxicity screening after anthracycline-based chemotherapy. This technology could serve as a gatekeeper to more costly cardiac imaging and could enable patients to monitor themselves over long periods of time.


Artificial intelligence electrocardiogram can be used to screen for an abnormal heart function after anthracycline chemotherapy, opening the door to new ways of cost-effective screening of cancer survivors at risk of cardiotoxicity over long periods of time.


Asunto(s)
Antraciclinas , Neoplasias de la Mama , Humanos , Femenino , Volumen Sistólico , Antraciclinas/efectos adversos , Cardiotoxicidad , Función Ventricular Izquierda , Estudios de Cohortes , Inteligencia Artificial , Detección Precoz del Cáncer , Electrocardiografía , Neoplasias de la Mama/tratamiento farmacológico , Antibióticos Antineoplásicos/efectos adversos
7.
Eur J Heart Fail ; 26(2): 511-520, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37905357

RESUMEN

AIM: Cardiac resynchronization therapy (CRT) is a cornerstone in the management of chronic heart failure in patients with a broad or paced QRS. However, data on long-term outcome after upgrade to CRT are scarce. METHODS AND RESULTS: This international, multicentre retrospective registry included 2275 patients who underwent a de novo or upgrade CRT implantation with a mean follow-up of 3.6 ± 2.7 years. The primary composite endpoint included all-cause mortality, heart transplantation, or ventricular assist device implantation. The secondary endpoint was first heart failure admission. Multivariable Cox regression and propensity score matching (PSM) analyses were performed. Patients who underwent CRT upgrade (n = 605, 26.6%) were less likely female (19.7% vs. 28.8%, p < 0.001), more often had ischeemic cardiomyopathy (49.8% vs. 40.2%, p < 0.001), and had worse renal function (median estimated glomerular filtration rate 50.3 ml/min/1.73 m2 [35.8-69.5] vs. 59.9 ml/min/1.73 m2 [43.0-76.5], p < 0.001). The incidence rate of the composite endpoint was 10.8%/year after CRT upgrade versus 7.1%/year for de novo implantations (p < 0.001). PSM for the primary endpoint resulted in 488 pairs. After propensity score matching, upgrade to CRT was associated with a higher chance to reach the composite endpoint (multivariable hazard ratio [HR] 1.35, 95% confidence interval [CI] 1.08-1.70), for both upgrade from pacemaker (multivariable HR 1.33, 95% CI 1.03-1.70) and implantable cardioverter-defibrillator (ICD) (multivariable HR 1.40, 95% CI 1.01-1.95). PSM for the secondary endpoint resulted in 277 pairs. After PSM, upgrade to CRT was associated with a higher chance for heart failure admission (HR 1.74, 95% CI 1.26-2.41). CONCLUSION: In this retrospective analysis, the outcome of patients who underwent upgrades to CRT differed significantly from patients who underwent de novo CRT implantation, particularly for upgrades from ICD. Importantly, this difference in outcome does not imply a causal relation between therapy and outcome but rather a difference between two different patient populations.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Femenino , Terapia de Resincronización Cardíaca/métodos , Puntaje de Propensión , Estudios Retrospectivos , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 46(12): 1455-1464, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37957879

RESUMEN

BACKGROUND: Leadless pacemakers (PMs) were recently introduced to overcome lead-related complications. They showed high safety and efficacy profiles. Prospective studies assessing long-term safety on cardiac structures are still missing. OBJECTIVE: The purpose of this study was to compare the mechanical impact of Micra with conventional PM on heart function. METHODS: We conducted a non-inferiority trial in patients with an indication for single chamber ventricular pacing. Patients were 1:1 randomized to undergo implantation of either Micra or conventional monochamber ventricular pacemaker (PM). Patients underwent echocardiography at baseline, 6 and 12 months after implantation. Analysis included left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and valve function. N-terminal-pro hormone B-type natriuretic peptide (NT-pro-BNP) levels were measured at baseline and 12 months. RESULTS: Fifty-one patients (27 in Micra group and 24 in conventional group) were included. Baseline characteristics were similar for both groups. At 12 months, (1) the left ventricular function as assessed by LVEF and GLS worsened similarly in both groups (∆LVEF -10 ± 7.3% and ∆GLS +5.7 ± 6.4 in Micra group vs. -13.4 ± 9.9% and +5.2 ± 3.2 in conventional group) (p = 0.218 and 0.778, respectively), (2) the severity of tricuspid valve regurgitation was significantly lower with Micra than conventional pacing (p = 0.009) and (3) median NT-pro-BNP was lower in Micra group (970 pg/dL in Micra group versus 1394 pg/dL in conventional group, p = 0.041). CONCLUSION: Micra is non inferior to conventional PMs concerning the evolution of left ventricular function at 12-month follow-up. Our data suggest that Micra has a comparable mechanical impact on the ventricular systolic function but resulted in less valvular dysfunction.


Asunto(s)
Marcapaso Artificial , Humanos , Estimulación Cardíaca Artificial/métodos , Corazón , Estudios Prospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
9.
Am Heart J ; 266: 48-60, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37595658

RESUMEN

BACKGROUND: Recently, an expert consensus statement proposed indications where implantation of a primary prevention implantable cardioverter-defibrillator (ICD) may be reasonable in patients with mitral valve prolapse (MVP). The objective was to evaluate the proposed risk stratification by the expert consensus statement. METHODS: Consecutive patients with MVP without alternative arrhythmic substrates with cardiac magnetic resonance imaging (CMR) were included in a single-center retrospective registry. Arrhythmic MVP (AMVP) was defined as a total premature ventricular complex burden ≥5%, non-sustained ventricular tachycardia (VT), VT, or ventricular fibrillation. The end point was a composite of SCD, VT, inducible VT, and appropriate ICD shocks. RESULTS: In total, 169 patients (52.1% male, median age 51.4 years) were included and 99 (58.6%) were classified as AMVP. Multivariate logistic regression identified the presence of late gadolinium enhancement (OR 2.82, 95%CI 1.45-5.50) and mitral annular disjunction (OR 1.98, 95%CI 1.02-3.86) as only predictors of AMVP. According to the EHRA risk stratification, 5 patients with AMVP (5.1%) had a secondary prevention ICD indication, while in 69 patients (69.7%) the implantation of an ICD may be reasonable. During a median follow-up of 8.0 years (IQR 5.0-15.6), the incidence rate for the composite arrhythmic end point was 0.3%/year (95%CI 0.1-0.8). CONCLUSION: More than half of MVP patients referred for CMR met the AMVP diagnostic criteria. Despite low long-term event rates, in 70% of patients with AMVP the implantation of an ICD may be reasonable. Risk stratification of SCD in MVP remains an important knowledge gap and requires urgent investigation.


Asunto(s)
Prolapso de la Válvula Mitral , Complejos Prematuros Ventriculares , Humanos , Masculino , Persona de Mediana Edad , Femenino , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico , Medios de Contraste , Estudios Retrospectivos , Gadolinio , Válvula Mitral , Medición de Riesgo
10.
Int J Cardiovasc Imaging ; 39(10): 2005-2014, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37421578

RESUMEN

PURPOSE: While implantable cardioverter-defibrillator (ICD) therapy provides clear benefit in patients with ischemic cardiomyopathy (ICM), this is less clear in patients with non-ischemic cardiomyopathy (NICM). Mid-wall striae (MWS) fibrosis is an established cardiovascular magnetic resonance (CMR) risk marker observed in patients with NICM. We evaluated whether patients with NICM and MWS have similar risk of arrhythmia-related cardiovascular events as patients with ICM. METHODS: We studied a cohort of patients undergoing CMR. The presence of MWS was adjudicated by experienced physicians. The primary outcome was a composite of implantable cardioverter-defibrillator (ICD) implant, hospitalization for ventricular tachycardia, resuscitated cardiac arrest, or sudden cardiac death. Propensity-matched analysis was performed to compare outcomes for patients NICM with MWS and ICM. RESULTS: A total of 1,732 patients were studied, 972 NICM (706 without MWS, 266 with MWS) and 760 ICM. NICM patients with MWS were more likely to experience the primary outcome versus those without MWS (unadjusted subdistribution hazard ratio (subHR) 2.26, 95% confidence interval [CI] 1.51-3.41) with no difference versus ICM patients (unadjusted subHR 1.32, 95% CI 0.93-1.86). Similar results were seen in a propensity-matched population (adjusted subHR 1.11, 95% CI 0.63-1.98, p = 0.711). CONCLUSION: Patients with NICM and MWS demonstrate significantly higher arrhythmic risk compared to NICM without MWS. After adjustment, the arrhythmia risk of patients with NICM and MWS was similar to patients with ICM. Accordingly, physicians could consider the presence of MWS when making clinical decisions regarding arrhythmia risk management in patients with NICM.

11.
Front Digit Health ; 5: 1201392, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37448836

RESUMEN

In the past decades there has been a substantial evolution in data management and data processing techniques. New data architectures made analysis of big data feasible, healthcare is orienting towards personalized medicine with digital health initiatives, and artificial intelligence (AI) is becoming of increasing importance. Despite being a trendy research topic, only very few applications reach the stage where they are implemented in clinical practice. This review provides an overview of current methodologies and identifies clinical and organizational challenges for AI in healthcare.

12.
J Arrhythm ; 39(3): 250-302, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37324757

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.

13.
Physiol Meas ; 44(7)2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37336241

RESUMEN

Background.The analysis of multi-lead electrocardiographic (ECG) signals requires integrating the information derived from each lead to reach clinically relevant conclusions. This analysis could benefit from data-driven methods compacting the information in those leads into lower-dimensional representations (i.e. 2 or 3 dimensions instead of 12).Objective.We propose Laplacian Eigenmaps (LE) to create a unified framework where ECGs from different subjects can be compared and their abnormalities are enhanced.Approach.We conceive a normal reference ECG space based on LE, calculated using signals of healthy subjects in sinus rhythm. Signals from new subjects can be mapped onto this reference space creating a loop per heartbeat that captures ECG abnormalities. A set of parameters, based on distance metrics and on the shape of loops, are proposed to quantify the differences between subjects.Main results.This methodology was applied to find structural and arrhythmogenic changes in the ECG. The LE framework consistently captured the characteristics of healthy ECGs, confirming that normal signals behaved similarly in the LE space. Significant differences between normal signals, and those from patients with ischemic heart disease or dilated cardiomyopathy were detected. In contrast, LE biomarkers did not identify differences between patients with cardiomyopathy and a history of ventricular arrhythmia and their matched controls.Significance.This LE unified framework offers a new representation of multi-lead signals, reducing dimensionality while enhancing imperceptible abnormalities and enabling the comparison of signals of different subjects.


Asunto(s)
Electrocardiografía , Isquemia Miocárdica , Humanos , Electrocardiografía/métodos , Arritmias Cardíacas , Frecuencia Cardíaca
14.
Curr Cardiovasc Risk Rep ; 17(6): 103-115, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37305214

RESUMEN

Purpose of Review: Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) is an important part of patient follow-up. The increasing number of patients with CIEDs and the recent pandemic pose several challenges for already limited device clinic resources. This review focuses on recent evolutions in RM and identifies future needs to improve RM. Recent Findings: RM has been associated with multiple clinical benefits, including improved survival, early detection of actionable events, reduction in inappropriate shocks, longer battery lives, and more efficient healthcare utilization. The survival benefit was driven by studies using alert-based continuous RM with daily transmissions and fast reaction times. Patients report a high satisfaction rate without significant differences in quality of life between RM and in-office follow-up.The increasing workload, due to the increasing number of CIEDs implanted with daily remote transmissions, results in several challenges for the future of RM. RM requires appropriate reimbursement for RM device clinics to optimize patient/staff ratios, including sufficient non-clinical and administrative support. Universal alert programming and data processing may minimize inter-manufacturer differences, improve the signal-to-noise ratio, and allow the development of standard operating protocols and workflows. In the future, programming by remote control and true remote programming may further improve remote CIED management, patient quality of life, and device clinic workflows. Summary: RM should be considered standard of care in management of patients with CIEDs. The clinical benefits of RM can be maximized by an alert-based continuous RM model. Adapted healthcare policies are required to keep RM manageable for the future.

15.
Front Cardiovasc Med ; 10: 1142429, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37180811

RESUMEN

Cardiac electrophysiology is a constantly evolving speciality that has benefited from technological innovation and refinements over the past several decades. Despite the potential of these technologies to reshape patient care, their upfront costs pose a challenge to health policymakers who are responsible for the assessment of the novel technology in the context of increasingly limited resources. In this context, it is critical for new therapies or technologies to demonstrate that the measured improvement in patients' outcomes for the cost of achieving that improvement is within conventional benchmarks for acceptable health care value. The field of Health Economics, specifically economic evaluation methods, facilitates this assessment of value in health care. In this review, we provide an overview of the basic principles of economic evaluation and provide historical applications within the field of cardiac electrophysiology. Specifically, the cost-effectiveness of catheter ablation for both atrial fibrillation (AF) and ventricular tachycardia, novel oral anticoagulants for stroke prevention in AF, left atrial appendage occlusion devices, implantable cardioverter defibrillators, and cardiac resynchronization therapy will be reviewed.

16.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37208301

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Asunto(s)
Monitoreo Fisiológico , Telemetría , Humanos
17.
Heart Rhythm ; 20(9): e92-e144, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37211145

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Asunto(s)
Desfibriladores Implantables , Tecnología de Sensores Remotos , Humanos
18.
Front Cardiovasc Med ; 10: 1097468, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37252121

RESUMEN

Aims: Diagnosis of Long QT syndrome (LQTS) is based on prolongation of the QT interval corrected for heart rate (QTc) on surface ECG and genotyping. However, up to 25% of genotype positive patients have a normal QTc interval. We recently showed that individualized QT interval (QTi) derived from 24 h holter data and defined as the QT value at the intersection of an RR interval of 1,000 ms with the linear regression line fitted through QT-RR data points of each individual patient was superior over QTc to predict mutation status in LQTS families. This study aimed to confirm the diagnostic value of QTi, fine-tune its cut-off value and evaluate intra-individual variability in patients with LQTS. Methods: From the Telemetric and Holter ECG Warehouse, 201 recordings from control individuals and 393 recordings from 254 LQTS patients were analysed. Cut-off values were obtained from ROC curves and validated against an in house LQTS and control cohort. Results: ROC curves indicated very good discrimination between controls and LQTS patients with QTi, both in females (AUC 0.96) and males (AUC 0.97). Using a gender dependent cut-off of 445 ms in females and 430 ms in males, a sensitivity of 88% and specificity of 96% were achieved, which was confirmed in the validation cohort. No significant intra-individual variability in QTi was observed in 76 LQTS patients for whom at least two holter recordings were available (483 ± 36 ms vs. 489 ± 42 ms, p = 0.11). Conclusions: This study confirms our initial findings and supports the use of QTi in the evaluation of LQTS families. Using the novel gender dependent cut-off values, a high diagnostic accuracy was achieved.

19.
J Clin Med ; 12(8)2023 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-37109274

RESUMEN

The history of cardiac pacing dates back to the 1930s with externalized pacing and has evolved to incorporate transvenous, multi-lead, or even leadless devices. Annual implantation rates of cardiac implantable electronic devices have increased since the introduction of the implantable system, likely related to expanding indications, and increasing global life expectancy and aging demographics. Here, we summarize the relevant literature on cardiac pacing to demonstrate the enormous impact it has had within the field of cardiology. Further, we look forward to the future of cardiac pacing, including conduction system pacing and leadless pacing strategies.

20.
Eur Heart J Cardiovasc Imaging ; 24(8): 1009-1016, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37114736

RESUMEN

AIMS: Papillary muscle (PM) abnormalities are considered part of the phenotypic spectrum of hypertrophic cardiomyopathy (HCM). The aim of this study was to evaluate the presence and frequency of PM displacement in different HCM phenotypes. METHODS AND RESULTS: We retrospectively analysed cardiovascular magnetic resonance (CMR) findings in 156 patients (25% females, median age 57 years). Patients were divided into three groups: septal hypertrophy (Sep-HCM, n = 70, 45%), mixed hypertrophy (Mixed-HCM, n = 48, 31%), and apical hypertrophy (Ap-HCM, n = 38, 24%). Fifty-five healthy subjects were enrolled as controls. Apical PM displacement was observed in 13% of controls and 55% of patients, which was most common in the Ap-HCM group, followed by the Mixed-HCM and Sep-HCM groups (respectively: inferomedial PM 92 vs. 65 vs. 13%, P < 0.001; anterolateral PM 61 vs. 40 vs. 9%, P < 0.001). Significant differences in PM displacement were found when comparing healthy controls with patients with Ap- and Mixed-HCM subtypes but not when comparing them with patients with the Sep-HCM subtype. T-wave inversion in the inferior and lateral leads was more frequent in patients with Ap-HCM (100 and 65%, respectively) when compared with Mixed-HCM (89 and 29%, respectively) and Sep-HCM (57 and 17%, respectively; P < 0.001 for both). Eight patients with Ap-HCM had prior CMR examinations because of T-wave inversion [median interval 7 (3-8) years], and in the first CMR study, none showed apical hypertrophy [median apical wall thickness 8 (7-9) mm], while all of them presented with apical PM displacement. CONCLUSION: Apical PM displacement is part of the phenotypic Ap-HCM spectrum and may precede the development of hypertrophy. These observations suggest a potential pathogenetic, mechanical link between apical PM displacement and Ap-HCM.


Asunto(s)
Miocardiopatía Hipertrófica Apical , Cardiomiopatía Hipertrófica , Femenino , Humanos , Persona de Mediana Edad , Masculino , Músculos Papilares/diagnóstico por imagen , Músculos Papilares/patología , Estudios Retrospectivos , Cardiomiopatía Hipertrófica/patología , Hipertrofia/patología , Fenotipo , Arritmias Cardíacas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA