Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Arthroplasty ; 13(5): 552-8, 1998 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9726321

RESUMEN

A prospective study of 116 consecutive Kinemax cemented posterior cruciate ligament-retaining total knee arthroplasties was carried out. Similar surgical technique was used with a single variable: 61 were implanted using intramedullary guides on the tibia and 55 were implanted using extramedullary guides on the tibia. A radiographic study was performed after at least 1 year of follow-up to evaluate postoperative component position and compare the difference in the accuracy of positioning of the femoral and tibial components. Radiographic analysis showed that satisfactory position was achieved using both types of instrumentation. No statistically significant difference was observed in either the coronal or sagittal plane of the femoral component and the sagittal plane positioning of the tibial component. However, the coronal plane positioning of the tibial component revealed a statistically significant difference (P < .01), with intramedullary guides being superior to extramedullary guides. Also observed, was that using either technique, patients with less accurate postoperative positioning tended to be obese, with wide intramedullary canals. Patients with significant extraarticular deformities, marked bowing, and those with prior surgery or fractures may not be suitable for intramedullary guides, and they may require the use of extramedullary guides and intraoperative radiographic control. The ideal indication for the use of intramedullary instrumentation is in the patient who is not obese, with no extraarticular deformity, and with a well-defined, but not excessively wide, tibial medullary canal. Since tibial component malalignment in general, and coronal plane malalignment in particular, may adversely affect the long-term survival of total knee arthroplasties, the use of intramedullary alignment instrumentation is recommended when possible.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Anciano , Estudios de Casos y Controles , Cementación , Femenino , Estudios de Seguimiento , Humanos , Fijadores Internos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Diseño de Prótesis , Radiografía , Tibia/cirugía , Factores de Tiempo
2.
Int Orthop ; 14(4): 367-9, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2076920

RESUMEN

Extraskeletal osteosarcoma is very rare and is difficult to diagnose histologically. We report a case of a 63 year old women who had such a tumour in her thigh.


Asunto(s)
Osteosarcoma/diagnóstico por imagen , Neoplasias de los Tejidos Blandos/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Osteosarcoma/patología , Osteosarcoma/cirugía , Radiografía , Neoplasias de los Tejidos Blandos/patología , Neoplasias de los Tejidos Blandos/cirugía , Muslo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA