Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 2601, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38297114

RESUMEN

This work provides the first experimental proof of an increased neutron capture photon signal following the introduction of boron to a PMMA phantom during helium and carbon ion therapies in Neutron Capture Enhanced Particle Therapy (NCEPT). NCEPT leverages [Formula: see text]B neutron capture, leading to the emission of detectable 478 keV photons. Experiments were performed at the Heavy Ion Medical Accelerator in Chiba, Japan, with two Poly(methyl methacrylate) (PMMA) targets, one bearing a boron insert. The BeNEdiCTE gamma-ray detector measured an increase in the 478 keV signal of 45 ± 7% and 26 ± 2% for carbon and helium ion irradiation, respectively. Our Geant4 Monte Carlo simulation model, developed to investigate photon origins, found less than 30% of detected photons originated from the insert, while boron in the detector's circuit boards contributed over 65%. Further, the model investigated detector sensitivity, establishing its capability to record a 10% increase in 478 keV photon detection at a target [Formula: see text]B concentration of 500 ppm using spectral windowing alone, and 25% when combined with temporal windowing. The linear response extended to concentrations up to 20,000 ppm. The increase in the signal in all evaluated cases confirm the potential of the proposed detector design for neutron capture quantification in NCEPT.

2.
Phys Med ; 90: 176-187, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34688192

RESUMEN

In this study, Monte Carlo codes, Geant4 and MCNP6, were used to characterize the fast neutron therapeutic beam produced at iThemba LABS in South Africa. Experimental and simulation results were compared using the latest generation of Silicon on Insulator (SOI) microdosimeters from the Centre for Medical Radiation Physics (CMRP). Geant4 and MCNP6 were able to successfully model the neutron gantry and simulate the expected neutron energy spectrum produced from the reaction by protons bombarding a 9Be target. The neutron beam was simulated in a water phantom and its characteristics recorded by the silicon microdosimeters; bare and covered by a 10B enriched boron carbide converter, at different positions. The microdosimetric quantities calculated using Geant4 and MCNP6 are in agreement with experimental measurements. The thermal neutron sensitivity and production of 10B capture products in the p+ boron-implanted dopant regions of the Bridge microdosimeter is investigated. The obtained results are useful for the future development of dedicated SOI microdosimeters for Boron Neutron Capture Therapy (BNCT). This paper provides a benchmark comparison of Geant4 and MCNP6 capabilities in the context of further applications of these codes for neutron microdosimetry.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Neutrones Rápidos , Método de Montecarlo , Neutrones , Radiometría , Silicio
3.
Phys Med ; 66: 8-14, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31541864

RESUMEN

The shift from reactor to accelerator based neutron production has created a renewed interested in Boron Neutron Capture Therapy (BNCT). BNCT is reliant upon the favourable uptake of 10B by tumour cells along with the interaction with neutrons to produce high LET fragments (He and Li nuclei) that deposit energy locally within the tumour cells. As with any radiation based treatment, Quality Assurance (QA) is crucial. In particular, Geant4 was used to model and optimise the geometry and packaging of Silicon on Insulator (SOI) microdosimeters for BNCT Quality Assurance purposes in view of experimental measurements at the KUR research reactor, in Japan. In this context, design optimisation pertains to the sensitive volume size and probability of neutron activation. This study has shown conclusively that whilst the materials currently used in the fabrication of silicon based microdosimeters are appropriate, there are changes with respect to the sensitive volume thickness that should be addressed to reduce the number of 'stoppers' in the microdosimeter.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Radiometría/instrumentación , Silicio , Método de Montecarlo , Control de Calidad , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA