RESUMEN
PURPOSE: In our aging society, the prevalence of degenerative spinal diseases rose drastically within the last years. However, up till now, the origin of cervical pain is incompletely understood. While animal and small cadaver studies indicate that a complex system of sensory and nociceptive nerve fibers in the anterior (ALL) and posterior longitudinal ligament (PLL) at the level of the intervertebral disc might be involved, there is a lack of data exploring whether such a network exists and is equally distributed within the cervical vertebrae (VB). We, therefore, aimed to investigate the spatial distribution of the mentioned nerve networks in human tissue. METHODS: We performed macroscopic (Sihler staining, Spalteholz technique, and Plastination) and microscopic (immunohistochemistry for PGP 9.5 and CGRP) studies to characterize spatial differences in sensory and nociceptive innervation patterns. Therefore, 23 human body donors were dissected from level C3-C6. RESULTS: We could show that there is a focal increase in sensory and nociceptive nerve fibers at the level of C4 and C5 for both ALL and PLL, while we observed less nerve fiber density at the level of C3 and C6. An anatomical vicinity between nerve and vessels was observed. CONCLUSION: To our knowledge, these findings for the first time report spatial differences in sensory and nociceptive nerve fibers in the human cervical spine at VB level. The interconnection between nerves and vessels supports the importance of the perivascular plexus. These findings might be of special interest for clinical practice as many patients suffer from pain after cervical spine surgery.
Asunto(s)
Degeneración del Disco Intervertebral/etiología , Ligamentos Longitudinales/inervación , Dolor de Cuello/etiología , Nocicepción/fisiología , Anciano , Anciano de 80 o más Años , Cadáver , Vértebras Cervicales , Femenino , Humanos , Degeneración del Disco Intervertebral/patología , Degeneración del Disco Intervertebral/fisiopatología , Ligamentos Longitudinales/patología , Masculino , Cuello , Dolor de Cuello/patología , Dolor de Cuello/fisiopatología , Fibras Nerviosas/patologíaRESUMEN
Since collagen rich fascial tissue is often very delicate and difficult to discern on native tissue slices, we have developed a method for staining full-body slices using the periodic acid-Schiff (PAS) reaction with subsequent plastination. Since the PAS reaction primarily stains carbohydrates, we could exploit the circumstance that different collagen types vary in carbohydrate content. Contrary to fasciae, tissues such as muscle, bone, nerves and blood vessels exhibit significantly less staining or remain unstained. We have validated the whole-body slice staining results in microscopic tissue slides which were stained with standard extracellular matrix stains such as Masson-Goldner trichrome stain and van-Gieson stain. Furthermore, we have performed immunofluorescence imaging to confirm the presence of collagen in the stained tissue. We achieved very good staining and plastination results and were able to clearly identify even very thin fascia in transversal body slices. This technique may prove useful in advancing our knowledge on the complex topography of fascial structures.
Asunto(s)
Anatomía Transversal/métodos , Cara/anatomía & histología , Reacción del Ácido Peryódico de Schiff/métodos , Anciano , Anciano de 80 o más Años , Cadáver , Colágeno/química , Colorantes , Desecación , Matriz Extracelular/patología , Matriz Extracelular/ultraestructura , Cara/patología , Técnica del Anticuerpo Fluorescente , Humanos , Inmunohistoquímica , Imagen por Resonancia Magnética , MasculinoRESUMEN
Introduction. The triangular fibrocartilage complex (TFCC) provides both mobility and stability of the radiocarpal joint. TFCC lesions are difficult to diagnose due to the complex anatomy. The standard treatment for TFCC lesions is arthroscopy, posing surgery-related risks onto the patients. This feasibility study aimed at developing a workup for soft-tissue reconstruction using clinical imaging, to verify these results in retrospective patient data. Methods. Microcomputed tomography (µ-CT), 3 T magnetic resonance imaging (MRI), and plastination were used to visualize the TFCC in cadaveric specimens applying segmentation-based 3D reconstruction. This approach further trialed the MRI dataset of a patient with minor radiological TFCC alterations but persistent pain. Results. TFCC reconstruction was impossible using µ-CT only but feasible using MRI, resulting in an appreciation of its substructures, as seen in the plastinates. Applying this approach allowed for visualizing a Palmer 2C lesion in a patient, confirming ex postum the arthroscopy findings, being markedly different from MRI (Palmer 1B). Discussion. This preliminary study showed that image-based TFCC reconstruction may help to identify pathologies invisible in standard MRI. The combined approach of µ-CT, MRI, and plastination allowed for a three-dimensional appreciation of the TFCC. Image quality and time expenditure limit the approach's usefulness as a diagnostic tool.
Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Fibrocartílago Triangular/diagnóstico por imagen , Fibrocartílago Triangular/patología , Adulto , Anciano de 80 o más Años , Humanos , Imagenología Tridimensional , Masculino , Reproducibilidad de los Resultados , Microtomografía por Rayos XRESUMEN
BACKGROUND: The ligaments in coherence with the capsule of the hip joint are known to contribute to hip stability. Nevertheless, the contribution of the mechanical properties of the ligaments and gender- or side-specific differences are still not completely clear. To date, comparisons of the hip capsule ligaments to other tissues stabilizing the pelvis and hip joint, e.g. the iliotibial tract, were not performed. MATERIALS & METHODS: Hip capsule ligaments were obtained from 17 human cadavers (9 females, 7 males, 13 left and 8 right sides, mean age 83.65 ± 10.54 years). 18 iliofemoral, 9 ischiofemoral and 17 pubofemoral ligaments were prepared. Uniaxial stress-strain properties were obtained from the load-deformation curves before the secant elastic modulus was computed. Strain, elastic modulus and cross sections were compared. RESULTS: Strain and elastic modulus revealed no significant differences between the iliofemoral (strain 129.8 ± 11.1%, elastic modulus 48.8 ± 21.4 N/mm2), ischiofemoral (strain 128.7 ± 13.7%, elastic modulus 37.5 ± 20.4 N/mm2) and pubofemoral (strain 133.2 ± 23.7%, elastic modulus 49.0 ± 32.1 N/mm2) ligaments. The iliofemoral ligament (53.5 ± 15.1 mm2) yielded a significantly higher cross section compared to the ischiofemoral (19.2 ± 13.2 mm2) and pubofemoral (15.2 ± 7.2 mm2) ligament. No significant gender- or side-specific differences were determined. A comparison to the published data on the iliotibial tract revealed lower elasticity and less variation in the ligaments of the hip joint. CONCLUSION: Comparison of the mechanical data of the hip joint ligaments indicates that their role may likely exceed a function as a mechanical stabilizer. Uniaxial testing of interwoven collagen fibers might lead to a misinterpretation of the mechanical properties of the hip capsule ligaments in the given setup, concealing its uniaxial properties. This underlines the need for a polyaxial test setup using fresh and non-embalmed tissues.
RESUMEN
BACKGROUND: To ensure adequate function after orthopedic tumor reconstruction, it is important to reattach the remaining soft tissue to the implant. This study aimed at obtaining mechanical properties of textile muscle-implant and muscle-bone connections in a preliminary test. METHODS: Two groups of soft-tissue attachment were mechanically tested and compared: Native bone-muscle samples obtained from human femora and muscles attached to a prosthetic implant by means of Trevira® attachment tubes. Additionally, muscle samples were tested with muscle fibers aligned parallel and perpendicular to the tension load. A uniaxial load was exerted upon all samples. RESULTS: Failure loads of 26.7 ± 8.8 N were observed for the native bone-muscle group and of 18.1 ± 9.9 N for the Trevira® group. Elongations of 94.8 ± 36.2 % were observed for the native bone-muscle group and 79.3 ± 51.8 % for the Trevira® group. The location of failure was mainly observed in the central area of the muscle fibers. Muscle fibers with parallel fiber orientation (47.6 ± 11.5 N) yielded higher tensile strength than those with perpendicular fiber orientation (14.8 ± 4.1 N). CONCLUSIONS: Our experiments showed that higher forces were transmitted in the origin and insertion areas than in areas of flat soft tissue reconstruction using attachment tubes. The data indicate that the tested material allows reattaching muscles, but without reinforcing the insertion site. Therefore, attachment tubes with region-dependent and potentially anisotropic material behavior might be advantageous to optimize muscle-bone load transmission after surgery, which may allow lower complication rates and shorter physical recovery.