Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Nat Commun ; 14(1): 4192, 2023 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-37443317

RESUMEN

Precision medicine requires highly scalable methods of multiplexed biomarker quantification that can accurately describe patient physiology. Unfortunately, contemporary molecular detection methods are generally limited to a dynamic range of sensitivity spanning just 3-4 orders of magnitude, whereas the actual physiological dynamic range of the human plasma proteome spans more than 10 orders of magnitude. Current methods rely on sample splitting and differential dilution to compensate for this mismatch, but such measures greatly limit the reproducibility and scalability that can be achieved-in particular, the effects of non-linear dilution can greatly confound the analysis of multiplexed assays. We describe here a two-pronged strategy for equalizing the signal generated by each analyte in a multiplexed panel, thereby enabling simultaneous quantification of targets spanning a wide range of concentrations. We apply our 'EVROS' strategy to a proximity ligation assay and demonstrate simultaneous quantification of four analytes present at concentrations spanning from low femtomolar to mid-nanomolar levels. In this initial demonstration, we achieve a dynamic range spanning seven orders of magnitude in a single 5 µl sample of undiluted human serum, highlighting the opportunity to achieve sensitive, accurate detection of diverse analytes in a highly multiplexed fashion.


Asunto(s)
Reproducibilidad de los Resultados , Humanos , Biomarcadores
2.
Sci Rep ; 11(1): 2725, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33526802

RESUMEN

The characteristic depth dose deposition of ion beams, with a maximum at the end of their range (Bragg peak) allows for local treatment delivery, resulting in better sparing of the adjacent healthy tissues compared to other forms of external beam radiotherapy treatments. However, the optimal clinical exploitation of the favorable ion beam ballistic is hampered by uncertainties in the in vivo Bragg peak position. Ionoacoustics is based on the detection of thermoacoustic pressure waves induced by a properly pulsed ion beam (e.g., produced by modern compact accelerators) to image the irradiated volume. Co-registration between ionoacoustics and ultrasound imaging offers a promising opportunity to monitor the ion beam and patient anatomy during the treatment. Nevertheless, the detection of the ionoacoustic waves is challenging due to very low pressure amplitudes and frequencies (mPa/kHz) observed in clinical applications. We investigate contrast agents to enhance the acoustic emission. Ultrasound microbubbles are used to increase the ionoacoustic frequency around the microbubble resonance frequency. Moreover, India ink is investigated as a possible mean to enhance the signal amplitude by taking advantage of additional optical photon absorption along the ion beam and subsequent photoacoustic effect. We report amplitude increase of up to 200% of the ionoacoustic signal emission in the MHz frequency range by combining microbubbles and India ink contrast agents.

3.
J Microelectromech Syst ; 27(4): 719-729, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31452581

RESUMEN

We demonstrate a MEMS beam scanner capable of biaxial scanning with simultaneous focus control, for integration into a handheld confocal microscope for skin imaging. The device is based on a dual axis gimbal structure with an integrated largestroke deformable mirror. SU-8 polymer is used to construct both the deformable membrane as well as the torsional hinges for biaxial scanning. The 4 mm diameter mirror can perform raster pattern scanning with a range of +/- 1.5 degrees and Lissajous scanning with a range of +/- 3 degrees (mechanical scan angle), and has a maximum deflection of 9 um for focus control. The design, fabrication and characterization of the opto-mechanical performance of the MEMS device are presented in this paper.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA